Air Duct Design & Sizing Duct sizing methods Static regain method Normally used with a computer package for high velocity systems (e.g. in main duct) Size air duct so that static pressure nearly offset the pressure loss of succeeding duct section along main duct T me

installed as described in the TDC or TDF addendum to the SMACNA Duct Construction Standards except the corners may not be bolted. Standard 5" metal clips may be used with spacing as shown in diagram. SLEEVE DUCT TYPICAL TDC/TDF JOINT DUCT 60" Duct 3 REQ'D. 48" Duct 3 REQ'D. 36" Duct 3 REQ'D. 24" Duct 2 REQ'D. 18" DUCT and .

Under Floor Duct 1.5 OFFSET FOR #6 DUCT PU6-OFS15 Duct / Under Floor Duct. L 4 International Drive Rye Brook, NY 10573 Toll Free: 1 888.764.7681 Phone: 914.934.2075 Fax: 914.934.2190 MonoSystems.com 03/2016 DOCUMENT REF. NO. PU6FFL45-PU6WE Manufactured by MonoSystems, Inc. Under Floor Duct

lsc bus duct system 1. introduction 3 1.1 general specifications 1.2 outstanding feature of lsc bus duct 1.3 cataloging 2. high power distribution (600a 6000a) 9 2.1 general specifications 2.1.1 i-series bus duct 2.1.2 8-series bus duct 2.1.3 f-series bus duct 2.1.4 y-series bus duct 2.2 grounding & ip degree 2.2.1 grounding 2.2.2 ip degree 2.3 .

Duct Sizing Tools OR Duct Sizing Chart Ductulator (Manual/Digital) AIRAH DA3 Duct Design Manual Manufacturers/Programs . Duct Sizing Methods . More available in the ASHRAE Handbook or SMACNA Obtain other duct fittings pressure losses from manufacturers such as duct heaters, dampers, filters, grilles, coils, etc

Duct leakage concepts. Conventional forced air heating and cooling systems employ an air distribution system that includes an air handler and a duct system. The air handler is designed to remove air from the house, condition it, and supply it back to each room. Duct leakage (Figure 1) can occur on either the supply side or the return side of

this hood is designed to use a 6" round duct - it may be transitioned to a 3-1/4" x 10" rectangular duct never reduce duct size. undersized ducting severely restricts air flow and harms performance. (example: the area of a 6" duct is more than twice that of a 4" duct) keep duct runs as short and straight as possible.

Catalogue - 06 GALVANIZED PIPE & FITTINGS GALVANIZED DUT 4' SE TION MODEL DESCRIPTION PRICE GV1214 8" x 8" Rectangular Duct 30GA 21.64 GV1215 8" x 10" Rectangular Duct 30GA 22.47 GV1216 8" x 12" Rectangular Duct 30GA 23.31 GV1217 8" x 14" Rectangular Duct 30GA 24.14 GV1218 8" x 16" Rectangular Duct 30GA 24.97

Capacity Correction Factor for Height Difference 8. Noise Data 9. Electrical Characteristics 10. Static Pressure . Corresponding relation between Rectangular duct and Round duct 5. Method for duct calculation 6. Unit conversion 7. Recommended outlet velocity for different occasions . Indoor air flow (Hi/Med/Lo) (No duct) CFM 353/283/177 353 .

The Duct Pressurization Test Duct pressurization tests are well doc umented; they have been used for sev eral years to measure duct leakage to the outdoors. While there are several duct pressurization tests, this article uses the term to denote the test proce-off, the duct tester blows air into the duct system until

and oval duct is easy to install, looks great, saves time and reduces costs. 3 DUCT SYSTEM DESIGN MATERIALS AVAILABLE Aluminum Galvanized steel Stainless steel SIZES AVAILABLE Round spiral duct up to 120" in diameter Round longitudinal seam duct to 100 " in diameter Oval spiral duct in over 350 sizes with minors 4 .

Feb 26, 2019 · Smoke introduced into this air duct system will be distributed throughout the entire building. Smoke detectors designed for use in air duct systems are used to sense the presence of smoke in the duct. Model DNR Air Duct Smoke Detector uses photoelectric technology for the detection of smoke. This detection method, when combined with an efficient

duct board can provide an alternative to wrapped or liner insulation. Duct board is more rigid than duct liner or duct wrap and can be easily cut, taped together and made into a rectangular duct section. When properly assembled into a system, duct board offers low leakage and can be a cost effective option to du

ducts, existing data bases of duct leakage area meas U f'.m nts, the impacts of duct leakage on space-con d1t1oning energy consumption and peak demand and he ventilation impacts of duct leakage. The pape; also includes a brief discussion of techniques for sealing duct systems in the field. The results derived from duct leakage area and .

bus duct section 23a has inner joint covers identical to the inner joint covers 48 and 4 on the bus duct section 20. This construction and arrangement can be readily observed in FIGURE 8, where a bus duct section 120 identical to the bus duct sections 20 and 23a is fully shown. The bus duct section 20 contains three bus bars 47, 43,

Restricted duct access or external insulation Few constraints to the Aeroseal process Labor drives retrofit duct sealing costs Blocking ducts for pressurization and sealant delivery Measuring duct leakage costs nearly as much as sealing duct leakage Verification of sealed leakage is built into the process

notes: 1. tdc duct constructed per smacna standards-first edition 1995 2. duct fabricated using pittsburg seams. 3. all duct stiffened by machine formed beads spaced at 12” o.c. 4. duct work to be sealed per smacna hvac table 1-2 5. tdc cnt-jnt-co

IMPERIAL MANUFACTURING GROUP INC. / GALVANIZED DUCT, PIPE & FITTINGS PAGE 5 Galvanized Duct, Pipe & Fittings IMG DIMENSION / UNIT STD . STD . RACK UPC SKUDESCRIPTION MSRPKG QTYQTYCODE Stack Duct - 30 Gauge GV1306 2-1/4" x 10" x 24" Stack Duct 30ga /ft . 12' Ctn - 063467112839 GV1318 2-1/4" x 12" x 24" Stack Duct 30ga /ft .

Commercial & Industrial Duct System Insulation Flexible Fiberglass Duct Wrap Applications with optional joint finishes Local Manufacturing Plant Duct Insulation 2" tk. fiberglass duct wrap insulation with 3" wide FSK Tape on all joints & seams Local Middle School Duct Insulation 2.2" tk. fiberglass duct wrap insulation with

3M Fire Barrier Duct Wrap 615 is the only fire rated duct wrap you need for code required protection of grease and air ducts. Now, in a lighter weight, 6pcf density, it is certified according to ASTM E2336 (grease duct test standard) in two layer systems and ISO 6944 (air duct test standard) in single layer systems. The product

Install horizontal flex duct hangers at least every 4 feet (1.2 m). Install vertical flex duct hangers at least every 6 feet (1.8 m) Install flex duct so that sag does not exceed ½ in. per ft (42 mm per m). That means no more than 1" of sag between hangers. Use flex duct

ANSI/SMACNA HVAC Air Duct Leakage Test Manual. . leakage class for duct, not a percent. 90.1 class 4 all duct IECC class 4 all duct IAPMO GPMCS class 4 all duct. Why not use a % to fan flow? ASHRAE RP 1292. Active Tests vs Static Tests Active test –test performed on a File Size: 1MBPage Count: 59

Unifrax's FyreWrap Elite 1.5 Duct Insulation is a single-layer flexible duct wrap enclosure for 1- and 2-hour fire-rated air distribution systems (ADS ducts). Typical duct types include smoke control, hazardous exhaust, laboratory chemical fume, stairwell and vestibule pressurization, ventilation, supply/return ducts, commercial dryer exhaust,

dimensions in 4', 5' and 8' lengths. All duct sizes and lengths are produced on the Snappy revolutionary Automatic Duct Line, insuring the highest quality duct available in todays industry. RECTANGULAR DUCT FITTINGS- Die punched parts and riveted construction make Snappy duct fittings the best in the market.

determining the duct pressure WRT to outside as it was in Example 1. Note: If the buried duct energy credit is taken for WSEC-R code compliance, a duct leakage test is required, where duct leakage shall not exceed 0.03 CFM/sf x floor area (in sf). This publication contains material written and produced for public distribution.

method of duct fabrication, method of sealing, workmanship, and static pressure differential. An equation that describes leakage as a function of leakage class and static pressure is presented in the "Duct Design" chapter of the 1993 ASHRAE Handbook. This equation is used to calculate the leakage rate through a unit of duct surface for constant .

CIRCULAR ELECTRIC DUCT HEATERS Resetting of manual overheating protection Setpoint adjustment (-MQU /-MTU) AIR P rating in W Q air flow rate in m³/h t temperature rise in C π D² 4 V air velocity, m/s Q air flow rate, m³/h A cross-section area of duct heater, m² D diameter of duct heater, m Q 3600 A CIRCULAR .

unit dimensions approx. mbh @5300' lbs/hr 212.9 @5300' cfm 5400 (in wc) esp 1.0 hp supply fan data 3 dia type / fc . air duct down air duct up rect return/exh rect return/exh air duct down blow-off valve union in-line pump/circ. pump air duct up rectangular supply rectangular supply pressure/temperature tap flow switch shut-off valve globe .

Duct S2 to be installed in narrow roof spaces. 3-way service access for easy maintenance Duct S2 features removable panels on three sides, making maintenance easier than ever before. Duct S2 5.2kW to 14kW models Larger capacity models: 16, 18, and 20kW indoor unit can easily be separated for easy handling and manoeuvring into tight installation .

EQUIVALENT DUCT CALCULATOR APP USER GUIDE Introduction Round is the most efficient duct shape for transporting air. Round duct has less surface area, weight and fewer joints than rectangular duct. It is much easier to seal and can easily be specified to meet SMACNA Class 3 Leakage even at 10 in. wg static pressures.File Size: 1MB

Hydraulic diameter: for a rectangular duct - diameter of a round duct whcih has the same pressure loss as the rectangual r duct at the same air flow rate and coefficient of friction. Formula: d h 2 a b/a b. Equivalent diameter: for a rectangular duct - diameter of a round duct whcih has the same pressure loss as the rectangual r

MEDIUM POWER DISTRIBUTION (100A 400A) 45 3.1 M-SERIES (MINI BUS DUCT) 3.2 B-SERIES (BABY BUS DUCT) 4. AIR INSULATED BUS DUCT 51 4.1 A-SERIES (LOW VOLTAGE) 4.2 H-SERIES (HIGH VOLTAGE) BUSDUCT최종(P) 2006.2.13 1:33 PM 페이지3. 1. INTRODUCTION . other method of low voltage power distribution. While material costs may be slightly higher, the .

Tsal et al 1998, T-method duct design: Part IV - Duct leakage theory, ASHRAE Transaction. UK SAP ( UK Standard Assessment Procedure for rigid duct), 14/February/2011 BS EN 13141-6:2004, to define the duct configurations Directive 2002/91/EC of the European Parliament and of the Council, Dec 16th 2002 CEN standard CE-XX-YY

Unifrax's FyreWrap Elite 1.5 Duct Insulation is a single-layer flexible duct wrap enclosure for 1- and 2-hour fire-rated air distribution systems (ADS ducts). Typical duct types include smoke control, stairwell and vestibule pressurization, ventilation, supply/return ducts, commercial dryer exhaust, as well as refuse and linen chutes.

duct systems convey the cold air from the air conditioning equipment to the proper air distribution point and also carry the return air . HVAC system design is a major sub discipline of Mechanical Engineering based on the principles of Thermodynamics, Fluid Mechanics, and Heat Transfer. HVAC systems provide: Heating .

6" Fresh Air Inlet (Optional) 10" Return Air Inlet 10" Supply Air Outlet A B C A B C Flow Front View Rear View A B Fresh Air Ventilation Duct Fresh air ventilation is optional. A 6" diameter duct is attached to the unit. The 6" duct should be capped if fresh air is not desired. If setting up the unit to pro

Duct Width Spiral Seam Duct Gauge Fitting Gauge to 24" 24 20 25 to 36" 22 20 37 to 48" 22 18 49 to 60" 20 18 61 to 70" 20 16 71" and up 18 16 DUAL WALL OVAL DUCT AND FITTINGS CONSTRUCTION STANDARDS Outer Shell Positive Pressure Gauge selection for galvanized (ASTM A653). Fittings are manufactured with standing seam, welded seam .

Transverse Duct Connector COMPANION FLANGE. DUCT CONSTRUCTION 9/15/99 INTERNATIONAL TRAINING INSTITUTE 17 Outside Straight Tap. DUCT CONSTRUCTION 9/15/99 . - The duct is 19" wide and larger and has more than 10 sqqpuare feet of unbraced panel. - Applicable to 20 gage or less and 3" w.g or less

closing 26 gauge (.45 mm) through 18 gauge (1.21 mm) rectangular duct work, including raw-to-raw, slip & drive and all transverse duct connectors. The Whisper-loc II quickly and quietly closes duct work in a fraction of the time required by conventional duct closure methods and without the danger of high noise levels.

4.3 Place the Leakage Tester on level ground adjacent to the duct selected for test. Attach the Duct Adaptor Plate (item 2.7) to the duct and connect the flexible hose to the duct plate and fan outlet spigot (item 2.11 ), using the hose sealing straps found in the tray (item 2.2).