Iec Test Report Form Template Intel-PDF Free Download

IEC TEST REPORT FORM TEMPLATE Intel
11 Jan 2020 | 57 views | 0 downloads | 169 Pages | 3.63 MB

Share Pdf : Iec Test Report Form Template Intel

Download and Preview : Iec Test Report Form Template Intel

Report CopyRight/DMCA Form For : Iec Test Report Form Template Intel



Transcription

Test Report issued under the responsibility of, TEST REPORT. IEC 60950 1, Information technology equipment Safety. Part 1 General requirements, Report Number 17041543 001. Date of issue Sep 09 2014, Total number of pages 103. Applicant s name Asian Power Devices Inc, Address No 5 Lane 83 Lung Sou St Taoyuan City 330 Taiwan.
Test specification, Standard IEC 60950 1 2005 Second Edition Am 1 2009 Am 2 2013. Test procedure CB Scheme, Non standard test method N A. Test Report Form No IEC60950 1F, Test Report Form s Originator SGS Fimko Ltd. Master TRF Dated 2014 02, Copyright 2014 IEC System of Conformity Assessment Schemes for Electrotechnical. Equipment and Components IECEE System All rights reserved. This publication may be reproduced in whole or in part for non commercial purposes as long as the IECEE is acknowledged as. copyright owner and source of the material IECEE takes no responsibility for and will not assume liability for damages resulting. from the reader s interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non IECEE members the IECEE IEC logo and the reference to the. CB Scheme procedure shall be removed, This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory.
and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. General disclaimer, The test results presented in this report relate only to the object tested. This report shall not be reproduced except in full without the written approval of the Issuing CB Testing. Laboratory The authenticity of this Test Report and its contents can be verified by contacting the NCB. responsible for this Test Report, Page 3 of 103 Report No 17041543 001. List of Attachments including a total number of pages in each attachment. Photo documentation 20 pages, Attachment 1 Contact resistance test 1 page. Attachment 2 Non detachable European plug test report 5 pages. Attachment 3 Detachable European plug test report 5 pages. Attachment 4 Non detachable UK plug test report 5 pages. Attachment 5 Detachable UK plug test report 5 pages. Attachment 6 Detachable Australian plug test report 10 pages. Attachment 7 Non detachable Japanese plug test report 4 pages. Attachment 8 Detachable Japanese plug test report 4 pages. Attachment 9 Non detachable Argentine plug test report 2 pages. Attachment 10 Detachable Argentine plug test report 3 pages. Summary of testing, Tests performed name of test and test clause Testing location. 1 Following tests performed during evaluation All tests as described in Test Case and. Clause s Test s Measurement Sections were performed at the. laboratory described on page 2, 1 6 2 Input Current Test.
1 7 11 Durability of Marking Test, 2 1 1 1 Access to energized parts. 2 1 1 5 Energy Hazard in Operator Access Area, 2 2 2 SELV limits for Normal Conditions. 2 2 3 SELV limits for Abnormal Conditions, 2 4 2 Limit Current Circuits. 2 5 Limited Power Sources, 2 9 2 Humidity Conditioning. 2 10 2 Working Voltage over Insulation, 2 10 3 Clearance and creepage distance.
2 10 4 measurements, 4 2 3 Steady force test 30 N, 4 2 4 Steady force test. 4 2 6 Drop test, 4 2 7 Stress relief test, 4 3 6 Torque Test direct plug in. 4 5 Maximum Temperature Test, 4 5 5 Ball pressure test. 5 1 6 Touch Current and PE current, 5 2 Electric Strength Test. 5 3 Fault Condition Test, If not otherwise specified tests were performed on model.
WB 10G05FG to represent other similar models, TRF No IEC60950 1F. Page 4 of 103 Report No 17041543 001, Summary of compliance with National Differences. EU Group Differences EU Special National Conditions AT AU BE CA CH CN CZ DE DK FI. FR GB GR HU IL IT JP KR NL NO PL SE SI SK US, Explanation of used codes AT Austria AU Australia BE Belgium CA Canada CH Switzerland. CN China CZ Czech Republic DE Germany DK Denmark FI Finland FR France GB United. Kingdom GR Greece HU Hungary IL Israel IT Italy JP Japan KR Korea NL The Netherlands. NO Norway PL Poland SE Sweden SI Slovenia SK Slovakia US United States of America. For National Differences see end of this test report. National differences to IEC 60950 1 2005 evaluated. National differences to IEC 60950 1 2005 A1 evaluated. Also Japanese national deviation evaluated according to IEC 60950 1 2001. The product fulfils the requirements of EN 60950 1 2006 A11 2009 A1 2010 A12 2011 A2 2013. Copy of marking plate, The artwork below may be only a draft The use of certification marks on a product must be authorized by. the respective NCBs that own these marks, WB 10G05FG.
TRF No IEC60950 1F, Page 5 of 103 Report No 17041543 001. Notes Since similar label used only label for models above listed to represent other similar ones. TRF No IEC60950 1F, Page 6 of 103 Report No 17041543 001. Test item particulars, Equipment mobility movable hand held transportable. stationary for building in x direct plug in, Connection to the mains x pluggable equipment x type A type B. permanent connection, detachable power supply cord.
non detachable power supply cord, not directly connected to the mains. Operating condition x continuous, rated operating resting time. Access location x operator accessible, restricted access location. Over voltage category OVC OVC I x OVC II OVC III OVC IV. Mains supply tolerance or absolute mains 10 requested by client. supply values, Tested for IT power systems x Yes only for Norway No. IT testing phase phase voltage V 230V, Class of equipment Class I x Class II Class III.
Not classified, Considered current rating of protective device as 16A. part of the building installation A, Pollution degree PD PD 1 x PD 2 PD 3. IP protection class IP20, Altitude during operation m Up to 5000m. Altitude of test laboratory m Below 2000m, Mass of equipment kg Approx 0 063. Possible test case verdicts, test case does not apply to the test object N A.
test object does meet the requirement P Pass, test object does not meet the requirement F Fail. Date of receipt of test item Jul 17 2014, Date s of performance of tests Aug 2014. General remarks, See Enclosure refers to additional information appended to the report. See appended table refers to a table appended to the report. Throughout this report a comma point is used as the decimal separator. TRF No IEC60950 1F, Page 7 of 103 Report No 17041543 001. Manufacturer s Declaration per sub clause 4 2 5 of IECEE 02. The application for obtaining a CB Test Certificate Yes. includes more than one factory location and a Not applicable. declaration from the Manufacturer stating that the. sample s submitted for evaluation is are, representative of the products from each factory has.
been provided, When differences exist they shall be identified in the General product information section. Name and address of factory ies Yang Ming Industrial. 1 2 Room No 10 Maliu Road Henggang Street, Long Gang District Shen Zhen China. APD Shenzhen DK Inc, 1 5 F No 1 Fengwei Street Dakang Community. Henggang Subdistrict Longgang District, Shenzhen P R China. General product information, 1 The products WB 10G05R and WB 10G05Fy for variable y see below are direct plug in type.
switching adapter for use with information technology equipment. 2 The bottom enclosure is secured to top enclosure by ultrasonic welding. 3 Mode WB 10G05R is identical to model WB 10G05Fy except for type designation and plug provide. WB 10G05Fy is provided with fixe plug WB 10G05R is provided with detachable plug The. detachable plug can be Argentine plug American plug Japanese plug UK plug Chinese plug. European plug Korean plug Australian plug and Brazil plug. 4 The specified Max ambient temperature is 45 C, 5 There are two types of PCB layout type A and type B Both types are identical to each other except. for primary line filter provided Type A PCB is provided with common mode choke LF1 while type B. PCB is provided with line choke L1, 6 The components DC1 RC1 RC2 CF3 DT NTC RT RL are optional If not otherwise specified the. optional components are provided during the test which is considered more strictly. 7 Reliability test of detachable plug also evaluated After 200 cycles mechanical operation test contact. resistance is in compliance with the requirement of IEC 61984 See attachment 2 for details. 8 European plug for both detachable plug and non detachable plug provided in the equipment has. been tested according to EN 50075 1990 See attachment 2 and attachment 3 UK plug for both. detachable plug and non detachable plug provided in the equipment has been tested according to. BS 1363 1 A4 See attachment 4 and attachment 5 Detachable Australian plug provided in the. equipment has been tested according to AS NZS 3112 A1 A2 See attachment 6 Japanese plug. for both detachable plug and non detachable plug provided in the equipment has been tested. according to JIS C8303 See attachment 7 and attachment 8 Argentine plug for both detachable. plug and non detachable plug provided in the equipment has been tested according to IRAM 2063. See attachment 9 and attachment 10 The plugs for other countries shall be evaluated when. submitted to national approval, 9 For models with non detachable plug the plug in part is fixed to the enclosure and the plug portions. incorporate pins are moulded together with enclosure that effectively prevents any disintegration or. conductive parts remaining in the socket For models with detachable plug the plugs are fixed with. enclosure by mechanical method that effectively prevents any disintegration or conductive parts. remaining in the socket, 10 The power supply is used for the altitude up to 5000m only clearance for functional insulation basic. insulation reinforced or double insulation of the EUT are evaluated according to IEC 60664 1 table. A 2 other aspects shall be evaluated during national approval. TRF No IEC60950 1F, Page 8 of 103 Report No 17041543 001.
Table A Definition of variables, Variable Range of variable Content. y is one letter indicates fixed plug of different countries. A denotes Argentine plug B denotes Brazil plug C, y A B C G K or U denotes Chinese plug G denotes European plug K. denotes UK plug U denotes American plug and, Japanese plug. Abbreviations used in the report, normal conditions N C single fault conditions S F C. functional insulation OP basic insulation BI, double insulation DI supplementary insulation SI.
between parts of opposite, polarity BOP reinforced insulation RI. Indicate used abbreviations if any, TRF No IEC60950 1F. Page 9 of 103 Report No 17041543 001, IEC 60950 1, Clause Requirement Test Result Remark Verdict. 1 GENERAL P, 1 5 Components P, 1 5 1 General P, Comply with IEC 60950 1 or relevant component see appended tables 1 5 1 P. 1 5 2 Evaluation and testing of components Components which are certified P. to IEC and or national, standards are used correctly.
within their ratings, Components not covered by, IEC standards are tested under. the conditions present in the, 1 5 3 Thermal controls No thermal controls N A. 1 5 4 Transformers Transformers used are suitable P. for their intended application, and comply with the relevant. requirements of the standard, and particularly Annex C. 1 5 5 Interconnecting cables SELV output cable provided as N A. part of this equipment and no, higher energy levels than.
240VA it s not possible to, present a hazard, 1 5 6 Capacitors bridging insulation Between primary and P. secondary Y1 capacitor CY1, according to IEC 60384 14. 1 5 7 Resistors bridging insulation No such resistors N A. 1 5 7 1 Resistors bridging functional basic or N A. supplementary insulation, 1 5 7 2 Resistors bridging double or reinforced insulation N A. between a c mains and other circuits, 1 5 7 3 Resistors bridging double or reinforced insulation N A. between a c mains and antenna or coaxial cable, 1 5 8 Components in equipment for IT power systems N A.
1 5 9 Surge suppressors No surge suppressors N A, 1 5 9 1 General N A. 1 5 9 2 Protection of VDRs N A, 1 5 9 3 Bridging of functional insulation by a VDR N A. 1 5 9 4 Bridging of basic insulation by a VDR No such construction N A. TRF No IEC60950 1F, Page 10 of 103 Report No 17041543 001. IEC 60950 1, Clause Requirement Test Result Remark Verdict. 1 5 9 5 Bridging of supplementary double or reinforced No such construction N A. insulation by a VDR, 1 6 Power interface P, 1 6 1 AC power distribution systems TN power system P.
1 6 2 Input current Highest load according to P, 1 2 2 1 for this equipment is the. operation with the maximum, specified by the manual. instruction see appended table, 1 6 3 Voltage limit of hand held equipment This appliance is not hand held N A. 1 6 4 Neutral conductor The neutral conductor insulated P. from earth and from the body, throughout the equipment as if. it were a line conductor, 1 7 Marking and instructions P.
1 7 1 Power rating and identification markings See below P. 1 7 1 1 Power rating marking P, Multiple mains supply connections Single power source P. Rated voltage s or voltage range s V 100 240V P, Symbol for nature of supply for d c only AC source N A. Rated frequency or rated frequency range Hz 50 60Hz P. Rated current mA or A 0 4A Max P, 1 7 1 2 Identification . been tested according to EN 50075 1990 See attachment 2 and attachment 3 UK plug for both

Related Books

Report No STRD1812071S TEST REPORT IEC 62133 2 Secondary

Report No STRD1812071S TEST REPORT IEC 62133 2 Secondary

Report No STRD1812071S Shenzhen SEM Test Technology Co Ltd Page 1 of 24 TEST REPORT IEC 62133 2 Secondary cells and batteries containing alkaline or other non acid

Catalog 12 Index ANSI ISA IEC VALVE SIZING ANSI ISA IEC

Catalog 12 Index ANSI ISA IEC VALVE SIZING ANSI ISA IEC

Catalog 12 WhisperTrim Cavitrol Micro Form Micro Flute Micro Flow Micro Flat Fisher and Fisher Rosemount are marks owned by Fisher Controls In ternational Inc orFisher Rosemount Systems inc All other marks are the property of their respective owners Globe and Angle Valve Bodies Over Class 600 Design Page 461 461 1 CAV4 CavitrolR IV Trim

IEC 60617 Graphical Symbols for Diagrams IEC

IEC 60617 Graphical Symbols for Diagrams IEC

International Electrotechnical Commission IEC 60617 Graphical Symbols for Diagrams Logout English French Home Introduction General description

Moving from ISO IEC 27001 2005 to ISO IEC 27001 2013

Moving from ISO IEC 27001 2005 to ISO IEC 27001 2013

Moving from ISO IEC 27001 2005 to ISO IEC 27001 2013 The new international standard for information security management systems Transition guide

IEC SC17A Harmonization of IEC amp ANSI IEEE Standards for

IEC SC17A Harmonization of IEC amp ANSI IEEE Standards for

IEC SC17A Harmonization of IEC amp ANSI IEEE Standards for High voltage Circuit breakers IEC Symposium Sapporo July 2004 Denis Dufournet Chairman TC17 amp SC17A

Differences between IEC 61850 9 2 9 2LE and IEC 61869 9

Differences between IEC 61850 9 2 9 2LE and IEC 61869 9

IEC 61850 9 2 LE v s IEC 61869 9 Differences between IEC 61850 9 2 9 2LE and IEC 61869 9 IEC 61869 9 is backward compatible with 9 2 LE communication IEC 61850 9 2 LE IEC 61869 9 Fiber optic transmission 100Base FX full duplex Same 1Gbit s ST or MTRJ Duplex LC or RJ45 Dataset 4 I 4 U FfSsIiUu Protection sampling rate 80 samples per period 4800 Hz Measurement

Basic template for the development of ISO and ISO IEC

Basic template for the development of ISO and ISO IEC

International Standard ISO 6496 was prepared by Technical Committee ISO TC 34 Agricultural food products Subcommittee SC 10 Animal feeding stuffs

TEST REPORT IEC 60950 1 2005 2nd Edition and or EN

TEST REPORT IEC 60950 1 2005 2nd Edition and or EN

IEC EN 60950 1 Clause Requirement Test Result Remark Verdict TRF No IECEN60950 1D 1 GENERAL 1 5 Components P 1 5 1 General P Comply with IEC 60950 1 or relevant component standard see appended table 1 5 1 P 1 5 2 Evaluation and testing of components Certified components are used in accordance with their

TEST REPORT IEC 60669 2 1 Switches for household and

TEST REPORT IEC 60669 2 1 Switches for household and

TRF No IEC60669 2 1E TEST REPORT IEC 60669 2 1 Switches for household and similar fixed electrical installations Part 2 1 Particular requirements Electronic switches

TEST REPORT IEC 61386 22 Conduit systems for cable

TEST REPORT IEC 61386 22 Conduit systems for cable

Page 6 of 27 Report No T211 0408 14 IEC 61386 22 Clause Requirement Test Result Remark Verdict TRF No IEC61386 22B 7 MARKING AND DOCUMENTATION P 7 1 Conduit conduit fitting is marked on the product with

TEST REPORT IEC 60529 EN 60529 Degrees of protection

TEST REPORT IEC 60529 EN 60529 Degrees of protection

IEC EN 60529 Clause Requirement Test Result Verdict TRF No IECEN60529A In the case of the first characteristic numerals 3 4 5 and 6 protection against access to hazardous parts is satisfied if adequate clearance is kept The adequate clearance should be specified by the relevant product committee in accordance with 12 3 EN 60529 A1 P

4P05805 R01 rev 1 Test Summary Report according to IEC

4P05805 R01 rev 1 Test Summary Report according to IEC

This report has been prepared in accordance with the requirements of IEC 61400 2 Edition 3 2013 in order to provide a summary of testing in support of consumer labelling in accordance with Annex M of the standard The Giraffe is a wooden construction including a hybrid system of both wind and solar energy production The above mentioned standard IEC 61400 2 is solely dedicated for consumer