MARINE WATER COOLED PACKAGED AIR CONDITIONING UNIT. Technical data 1 for R404A or R22, Type Vertical deck mount type. SCU P3VR SCU P5VR SCU P5VF SCU P8VR SCU P10VR, Plenum supply SCU P3VF SCU P8VF SCU P10VF. SCU D3VR SCU D5VR SCU D5VF SCU D8VR SCU D10VR, Duct supply SCU D3VF SCU D8VF SCU D10VF. AC440V x 3P x 60Hz AC220V x 1P x 60Hz, Main power source Control AC380V x 3P x 50Hz AC220V x 1P x 50Hz. Safety protective device High pressure low pressure over load lack phase lack cooling water over. temperature safety valve, Normal ref ton cooling 3 0 USRT 5 0 USRT 7 5 USRT 10 0 USRT.
10 4 Kw 17 4 Kw 26 1 Kw 34 8 Kw, Cooling capacity water cooled. 9 000 Kcal h 15 000 Kcal h 22 500 Kcal h 20 000 Kcal h. 9 Kw 12 Kw 15 Kw 20 Kw, Heating capacity electric heater. 7 759 Kcal h 10 345 Kcal h 12 931 Kcal h 17 241 Kcal h. Refrigerant R 404A R22, Casing coating Steel Synthetic resin powder coating. Type Hermetic reciprocating compressor, Fresh 50Hz 3 7 Kw 5 6 Kw 8 1 Kw 12 1 Kw. Compressor 60Hz 4 0 Kw 6 5 Kw 9 7 Kw 12 7 Kw, power Sea 50Hz 3 7 Kw 5 4 Kw 7 7 Kw 10 0 Kw.
60Hz 3 8 Kw 6 3 Kw 9 5 Kw 9 3 Kw, Type Horizontal shell tube type. water 60Hz, Condenser 3 0 M3 H 7 0 M3 H 8 0 M3 H 9 0 M3 H. flow rate 50Hz, water 60Hz, Pressure drop 9 KPa 25 KPa 25 KPa 9 KPa. Type Crossed fin and tube type, Evaporator Tube Copper. Fin Aluminum without fresh air Copper with fresh air. Type Double inlet centrifugal blower, R 30 CMM 1800 M3 H 45 CMM 2700 M3 H 65 CMM 3900 M3 H 90 CMM 5400 M3 H.
F 11 CMM 660 M3 H 15 CMM 900 M3 H 22 5 CMM 1350 M3 H 30 CMM 1800 M3 H. volume R 30 CMM 1800 M3 H 45 CMM 2700 M3 H 65 CMM 3900 M3 H 90 CMM 5400 M3 H. F 11 CMM 660 M3 H 15 CMM 900 M3 H 22 5 CMM 1350 M3 H 30 CMM 1800 M3 H. Blower Static P 150 Pa, P 50Hz 60Hz R 0 37 0 43 Kw 0 55 0 63 Kw 0 75 0 86 Kw 1 1 1 27 Kw. F 1 1 1 27 Kw 1 5 1 73 Kw 2 2 2 53 Kw 3 0 3 45 Kw, power D 50Hz 60Hz R 1 5 1 73 Kw 2 2 2 53 Kw 3 0 3 45 Kw 4 0 4 6 Kw. F 1 1 1 27 Kw 1 5 1 73 Kw 2 2 2 53 Kw 3 0 3 45 Kw, Piping Condenser inlet DN25 DN25 DN25 DN50. www alscott ca Rev 0101, Alscott reserves the right to change design or specification without prior notice. MARINE WATER COOLED PACKAGED AIR CONDITIONING UNIT. Connection Condenser outlet DN25 DN25 DN25 DN50, Drain G3 4 G3 4 G3 4 G3 4.
Refrigerant control Thermostatic expansion valve, Air filter Nonwoven cotton synthetic blend media G4. Colour As per maker s standard or client s requirement. Spare part V belt gaskets of condenser, Technical data 2 for R407C. Type Vertical deck mount type, SCU P3VR SCU P5VR SCU SCU P8VR SCU P10VR. Plenum supply, SCU P3VF P5VF SCU P8VF SCU P10VF, SCU D3VR SCU D5VR SCU SCU D8VR SCU D10VR. Duct supply, SCU D3VF D5VF SCU D8VF SCU D10VF, AC440V x 3P x 60Hz AC220V x 1P x 60Hz.
Main power source Control AC380V x 3P x 50Hz AC220V x 1P x 50Hz. Safety protective device High pressure low pressure over load lack phase lack cooling water. over temperature safety valve, Normal ref ton cooling 3 USRT 4 5 USRT 7 0 USRT 9 5 USRT. 10 4 Kw 15 8 Kw 24 6 Kw 33 3 Kw, Cooling capacity water cooled. 9 000 Kcal h 13 600 Kcal h 21 200 Kcal h 28 800 Kcal h. 9 Kw 12 Kw 15 Kw 20 Kw, Heating capacity electric heater. 7 759 Kcal h 10 345 Kcal h 12 931 Kcal h 17 241 Kcal h. Refrigerant R 407C, Casing coating Steel Synthetic resin powder coating. Type Hermetic reciprocating compressor, Fresh 50Hz 3 2 Kw 4 7 Kw 6 9 Kw 9 9 Kw.
Compressor Motor 60Hz 3 5 Kw 4 9 Kw 7 2 Kw 11 0 Kw. power Sea 50Hz 3 1 Kw 4 5 Kw 6 7 Kw 9 7 Kw, 60Hz 3 3 Kw 4 8 Kw 7 0 Kw 10 9 Kw. Type Horizontal shell tube type, Water water 60Hz, Condenser flow 8 0 M3 H 10 0 M3 H 16 0 M3 H 20 0 M3 H. water 60Hz, Pressure drop 30 KPa 35 KPa 25 KPa 25 KPa. Type Crossed fin and tube type, Evaporator Tube Copper. Fin Aluminum without fresh air Copper with fresh air. Type Double inlet centrifugal blower, R 30 CMM 1800 45 CMM 2700 M3 H 65 CMM 3900 M3 H 90 CMM 5400.
Blower Air M3 H M3 H, volume F 11 CMM 660 M3 H 15 CMM 900 M3 H 22 5 CMM 1350 30 CMM 1800 M3 H. www alscott ca Rev 0101, Alscott reserves the right to change design or specification without prior notice. MARINE WATER COOLED PACKAGED AIR CONDITIONING UNIT. R 30 CMM 1800 45 CMM 2700 M3 H 65 CMM 3900 M3 H 90 CMM 5400. F 11 CMM 660 M3 H 15 CMM 900 M3 H 22 5 CMM 1350 30 CMM 1800. Static P 150 Pa, P R 0 37 0 43 Kw 0 55 0 63 Kw 0 75 0 86 Kw 1 1 1 27 Kw. F 1 1 1 27 Kw 1 5 1 73 Kw 2 2 2 53 Kw 3 0 3 45 Kw, power D R 1 5 1 73 Kw 2 2 2 53 Kw 3 0 3 45 Kw 4 0 4 6 Kw. F 1 1 1 27 Kw 1 5 1 73 Kw 2 2 2 53 Kw 3 0 3 45 Kw, Condenser inlet DN25 DN25 DN50 DN50.
Piping Condenser outlet DN25 DN25 DN50 DN50, Connection. Drain G3 4 G3 4 G3 4 G3 4, Refrigerant control Thermostatic expansion valve. Air filter Nonwoven cotton synthetic blend media G4. Colour As per maker s standard or client s requirement. Spare part V belt gaskets of condenser, P Plenum supply type D Duct supply type R Duct supply type with return air F Duct supply type with 100 fresh. Sea water inlet temperature 32 fresh water inlet temperature 36. Normal design evaporating temperature 5 condensing temperature 45 for fresh water cooled type and. condensing temperature 42 for sea water cooled type. Other design is available on request refrigerant static pressure etc. www alscott ca Rev 0101, Alscott reserves the right to change design or specification without prior notice. MARINE WATER COOLED PACKAGED AIR CONDITIONING UNIT. Principal dimensions 1, For Plenum type, PAC type for L W H Weight.
Plenum mm mm mm Approx kg, SCU P3VR SCU, P3VF 1000 600 1900 300. SCU P5VR SCU, P5VF 1100 650 2000 350, SCU P8VR SCU. P8VF 1200 700 2100 400, SCU P10VR SCU, P10VF 1400 750 2100 450. www alscott ca Rev 0101, Alscott reserves the right to change design or specification without prior notice. The water cooled packaged air conditioner is specially designed for marine application such as engine control room workshop switchboard room galley etc which consists of air handling unit cooling unit control unit built on a common framework The unit has been factory tested including pressure

Related Books

Packaged air cooled water chillers EWAP EWYP 060 260

Packaged air cooled water chillers EWAP EWYP 060 260

maintenance by the user of Daikin EWAP EWYP chillers They do not contain full service procedures necessary for the continued successful operation of this equipment The services of a qualified technician should be employed through the medium of a maintenance contract with a reputable service company Read this manual thoroughly before unit start up Units are assembled pressure tested

A Newsletter For Air cooled amp Water cooled Volkswagen

A Newsletter For Air cooled amp Water cooled Volkswagen

The Club has decided in conjunction with the CENTRAL SOUTH CLUB to run the 2014 NZ VW Nationals in Timaru at Easter 2014 As the weekend of 20th 22nd July is the annual Cool Run to the Farmyard Camping Ground at Orari we will be having a meeting to discuss the format etc for this event

14 22HP AIR COOLED V TWIN Vanguard Air Cooled V Twin

14 22HP AIR COOLED V TWIN Vanguard Air Cooled V Twin

14 22HP AIR COOLED V TWIN SPECIFICATIONS 14 HP 16 HP 18 HP 20 HP 22 HP MODEL NUMBER 294400 303400 350400 381400 380400 295400 305400 356400 385400 386400 NO OF CYLINDERS 22222 BORE X STROKE 68 x 66mm 68 x 66mm 72 x 70mm 75 5 x 70mm 75 5 x 70mm 2 7 x 2 6in 2 7 x 2 6in 2 8 x 2 8in 3 x 2 8in 3 x 2 8in

DSV Model Air Cooled Self Contained Indoor Packaged Units

DSV Model Air Cooled Self Contained Indoor Packaged Units

MIN CCT MOP QTY RLA LRA HP FLA AMPACITY Max Overcurrent Protection DSV036A1 208 230 1 60 1 14 1 77 0 1 00 6 7 27 53 40 DSV036A2 208 230 3 60 1 9 0 71 0 1 00 3 0 16 05 25 DSV036A4 460 3 60 1 5 6 38 0 1 00 1 4 9 20 15 DSV036A5 575 3 60 1 3 8 36 5 1 00 1 1 6 45 15 MODEL VOLTAGE COMPRESSOR CONDENSER FAN Form 145 13 PA1 1108 November 2008 1 of 3 Page 2 DATE DESCRIPTION Johnson

Water Cooled Screw Chillers Air Conditioner AC Air

Water Cooled Screw Chillers Air Conditioner AC Air

Internationally AHRI certified test facilities fo

Air Cooled Liquid Chiller Reversible Air to Water Heat Pump

Air Cooled Liquid Chiller Reversible Air to Water Heat Pump

30RB RQ Modular Air Cooled Liquid Chiller Reversible Air to Water Heat Pump Nominal cooling capacity 65kW Nominal heating capacity 68kW

Air Cooled Liquid Chillers Air to Water Heat Pumps

Air Cooled Liquid Chillers Air to Water Heat Pumps

Air Cooled Liquid Chillers Air to Water Heat Pumps 30RB RQ 017 033 Nominal cooling capacity 17 33 kW Nominal heating capacity 17 33 kW The new generation of Aquasnap liquid chillers heat pumps was designed for commercial applications such as the air conditioning of offices and hotels etc The new Aquasnap units integrate the latest technological innovations ozone friendly refrigerant R410A

Marine Air Heater Systems Air Top 2000 S Air Top 3500 Air

Marine Air Heater Systems Air Top 2000 S Air Top 3500 Air

Marine Air Heater Systems Air Top 2000 S Air Top 3500 Air Top 5000 Do It Yourself Kit For Diesel Powered Marine Vessels WARNING CONCERNING INSTALLATIONS IN GASOLINE

HWP K Series WATER SOURCED PACKAGED AIR CONDITIONERS

HWP K Series WATER SOURCED PACKAGED AIR CONDITIONERS

water sourced packaged air conditioners applications manual june 2008 contents page 1 location and access 3 noise considerations 4 3 water treatment 5 4

Air cooled inverter water chillers - Daikin

Air cooled inverter water chillers - Daikin

Air cooled inverter water chiller MANUAL Operation Manual 6 EWAD TZ170 -710 Air cooled inverter water chiller D-EOMAC00909-14EN 1 SAFETY CONSIDERATIONS 1.1 General Installation, start-up and servicing of equipment can be hazardous if certain factors particular to the

Air cooled inverter water chillers - daikin.fr

Air cooled inverter water chillers - daikin.fr

Air cooled inverter water chiller MANUAL Operation Manual 6 EWAD TZ B 160-700 Air cooled inverter water chiller D-EOMAC00909-16EN 1 SAFETY CONSIDERATIONS 1.1 General Installation, start-up and servicing of equipment can be hazardous if certain factors particular to the

30RB 30RQ Air cooled liquid chillers and reversible air to

30RB 30RQ Air cooled liquid chillers and reversible air to

GB 1 30RB 30RQ Air cooled liquid chillers and reversible air to water heat pumps with integrated hydronic module ENGLISH For the use of the control system refer to the Pro Dialog control manual