Type H8C Load Cell - Zemic Europe

2y ago
52 Views
3 Downloads
595.44 KB
5 Pages
Last View : 19d ago
Last Download : 3m ago
Upload by : Aiyana Dorn
Transcription

Type H8C Load CellShort Description Nickel plated alloy steel IP67 shear beam load cell(100kg & 250kg are bending beam load cells)Adhesive sealedSuitable for platform weighing, bed weighing, etc.High accuracyHigh reliabilityCurrent calibrated (SC-option)Test certificate no. TC8012 Revision 1C of C no R60/2000-NL1-12.12Certificate no. 12-028Available ModelsCapacityAccuracyFull article pecifications and dimensions are subject to change without notice and do not constitute any liability whatsoever.Nr. 2020.12 H8C Rev15Page 1/5Zemic Europe B.V.T: 31 76 50 39480info@zemic.nlwww.zemiceurope.com

Type H8C Load CellTechnical Specifications H8CAccuracy ClassOutput Sensitivity ( FS )OIML R60 C3mV/VMaximum Capacity ( Emax )tMax. Number of Load Cell IntervalsRatio of min. LC Verification IntervalCombined ErrorCreep Error (30 minutes)Temperature Effect on Zero (ZTC)Temperature Effect on Sensitivity (STC)Zero BalanceSafe OverloadUltimate OverloadMaximum DeflectionExcitation, Recommended VoltageExcitation, Maximum VoltageInput ResistanceOutput ResistanceInsulation Resistance (50V)Compensated TemperatureOperating TemperatureStorage TemperatureLoad Cell WeightElement MaterialIngress Protection (acc. to EN 60529)Recommended Torque on Fixation BoltsATEX Classification (optional)nLCY Emax / vmin%FS%FS%FS/10 C%FS/10 C%FS%FS%FSmmVVΩΩMΩ C C CkgNmOIML R60 C43.0 0.0030.1, 0.25, 0.5, 075,1, 1.5, 2, 2.5, 3, 5, 10OIML R60 C50.1, 0.25,0.5, 0.75, 1,1.5, 2, 2.53, 5, 10300010000 0.023 0.016 0.015 0.01140005000150002000018000 0.0175 0.014 0.012 0.010 0.010 0.007 0.009 0.008 1.01503000.1t – 0.2t: 0.30.5t – 5t: 1.210t: 0.85 1218350 3.5350 3.5 5000-10 40-35 65-40 800.1t – 2.0t: 0.92.5t – 5t: 1.710t: 3.6Nickel plated alloy steelIP67M12: 100M18:200M24:700II1G Ex ia II1C T4 II1D Ex iaD 20 T73 C II3G Ex nL IIC T4WiringFeatures:Cable type:Shielded, 4 or 6 conductor cable, conductor AWG 22Cable diameter: Ø 5.0mmCable length:4m for 100kg – 2t; 6m for higher capacitiesShield not connected to element4-Wire Connection Diagram6-Wire Connection DiagramInput( )Output(-)RedWhitePage 2/5RedSense ( )BlueOutput(-)WhiteSense (-)YellowInput (-)BlackInput (-)BlackOutput( )GreenOutput( )GreenSpecifications and dimensions are subject to change without notice and do not constitute any liability whatsoever.Nr. 2020.12 H8C Rev15Input( )Zemic Europe B.V.T: 31 76 50 39480info@zemic.nlwww.zemiceurope.com

Type H8C Load CellOrdering InfoH8C – C3 – 1.0t – 4 – – BX – SC – XXOption XX. No mark is standard version, W4 is through loading hole,W6 is “T” end loading holeOption SC (standard current)Cable option. No mark is 4 conductor cable and with a “6” a 6 conductor cableThread option. No mark is Metric Thread and “Y” is Imperial threadLength of the cable in metersNominal capacity (𝐸𝑚𝑎𝑥 ) for Metric in t(on)Maximum load cell divisionsLoad Cell modelDimensions in mmStandard VersionSide ViewTop ViewIsometric ViewSpecifications and dimensions are subject to change without notice and do not constitute any liability whatsoever.Nr. 2020.12 H8C Rev15Page 3/5Zemic Europe B.V.T: 31 76 50 39480info@zemic.nlwww.zemiceurope.com

Type H8C Load CellOption W6 version (“T” end loading hole)Side ViewFront View11d1d1dd111Top ViewCapacityDimension1100kg -Ød1444-Ød2222-M12 x 1.7512 x 1.7518 x 1.524 x 2Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever.Nr. 2020.12 H8C Rev15Page 4/51Zemic Europe B.V.T: 31 76 50 39480info@zemic.nlwww.zemiceurope.com

Type H8C Load CellAvailable AccessoriesHJ-8-201-0.1-10t foot Ø60-86mm and height 92-112 mmNickel plated alloy steel Adjustable heightHJ-8-203-0.1-2t foot Ø67mm and height 46 mmNickel plated alloy steelEasy installationHJ-8-213-0.5-2t foot Ø60mm and height 62 mmNickel plated alloy steelAdjustable heightHJ-8-236-0.25-5t foot Ø80mm and height 50 mmNickel plated alloy steelAdjustable mountEasy installationElastomer-0.5-10t Easy installation Suitable for shock loadHM-8-402-0.5-5t mount Nickel plated alloy steel Adjustable mounting heightEasy installationHM-8-901-0.1t-2t/2.5t-5t mount Nickel plated alloy steel Lift-off and horizontal movement protectionEasy installation, including load cell dummyHY-8-102-0.5-5t Nickel plated alloy steel Easy installationGood self-alignment abilityHD-8-301-0.5-5t spacer plate Nickel plated alloy steelSpecifications and dimensions are subject to change without notice and do not constitute any liability whatsoever.Nr. 2020.12 H8C Rev15Page 5/5Zemic Europe B.V.T: 31 76 50 39480info@zemic.nlwww.zemiceurope.com

Easy installation HM-8-901-0.1t-2t/2.5t-5t mount Nickel plated alloy steel Lift-off and horizontal movement protection Easy installation, including load cell dummy HY-8-102-0.5-5t Nickel plated alloy steel Easy installation Goo

Related Documents:

of the cell and eventually divides into two daughter cells is termed cell cycle. Cell cycle includes three processes cell division, DNA replication and cell growth in coordinated way. Duration of cell cycle can vary from organism to organism and also from cell type to cell type. (e.g., in Yeast cell cycle is of 90 minutes, in human 24 hrs.)

UNIT-V:CELL STRUCTURE AND FUNCTION: 9. Cell- The Unit of Life: Cell- Cell theory and cell as the basic unit of life- overview of the cell. Prokaryotic and Eukoryotic cells, Ultra Structure of Plant cell (structure in detail and functions in brief), Cell membrane, Cell wall, Cell organelles: Endoplasmic reticulum, Mitochondria, Plastids,

Optimal Cell Load and Throughput in Green Small Cell Networks With Generalized Cell Association Chun-Hung Liu, Member, IEEE, and Li-Chun Wang, Fellow, IEEE Abstract—This paper thoroughly explores the fundamental interactions between cell association, cell load, and throughput in a green (energy-efficient)

5. CONNECTION TO LOAD CELL 5.1. Load Cell Input Terminal Assignment Use a solderless terminal with a width of 6.2 mm or less. Terminal No. Symbol Description 1 EXC Load cell excitation voltage 2 SEN Sensing input 3 SEN- Sensing input - 4 EXC- Load cell excitation voltage - 5 SIG Load cell signal

turning radius speed drawbar gradeability under mast with load center wheelbase load length minimum outside travel lifting lowering pull-max @ 1 mph (1.6 km/h) with load without load with load without load with load without load with load without load 11.8 in 12.6 in 347 in 201 in 16 mp

Floor Joist Spans 35 – 47 Floor Joist Bridging and Bracing Requirements 35 Joist Bridging Detail 35 10 psf Dead Load and 20 psf Live Load 36 – 37 10 psf Dead Load and 30 psf Live Load 38 – 39 10 psf Dead Load and 40 psf Live Load 40 – 41 10 psf Dead Load and 50 psf Live Load 42 – 43 15 psf Dead Load and 125 psf Live Load 44 – 45

STRAIN GAGE TYPE LOAD CELL MODEL ELC-150S-H . Users' Manual ELC-150S-H Strain gage type load cell . www.encardio.com . Contents 1 INTRODUCTION 1 1.1 Specifications 2 . Max. non linearity 0.41 % fs Rated output 1.580 mV/V @ 5000 kN Linear gauge factor 1) 316.456 kN/mV ( To be used to convert the mV o/p of load cell in .

Annual Report 2018 REPORT Contents The Provost 2 The Fellowship 5 Tutorial21 Undergraduates37 Graduates42 Chapel46 Choir 52 Research 60 Library and Archives 64 Bursary67 Staff 71 Development75 Major Promotions, Appointments or Awards 103 Appointments & Honours 104 Obituaries107 Information for Non-Resident Members 319. The University has been the subject of press attention in relation to the .