Product BrochureEaton 9315 UPS225-750 kVA

Power range225-750 kVAThe Eaton 9315 is ahighly reliable andflexible three-phaseUPS. Available insingle modules from225 kVA to 750 kVA,the 9315 can beparalleled for bothredundancy andcapacity usingpatented PowerwareHot Sync technologyfor systems up to3324 MW.225-300 kVA300-500 kVA625-750 kVAThe pursuit of 100percent availabilityThe Eaton 9315 UPSThe 9315 is available in thesesystem configurations:With technology fundamentalto business survival, it’s nowonder that IT managers,facility managers and CIOs feelincreasing pressure to achievezero downtime. As availabilityrequirements rise, so does thesearch for the most reliablepower protection system withthe most advanced technology.The 24/7 world is nothingnew to us. For more than 40years, that's exactly what ourcustomers have demandedwe address – and we've beendoing it to provide maximumuptime to the most criticalsystems. So when we saywe understand the pressureof “no downtime,” you can besure we really mean it.The 9315 UPS series gives youmaximum flexibility, reliabilityand system availability for yourentire enterprise, whether it'sin a single building or spreadaround the world. With thehighly reliable hardware,sophisticated powermanagement software, and amultitude of accessories andoptions, combined with worldclass service, the 9315 offersthe power solution – andsystem availability – that letsyou get down to the businessof your business. Single module – reversetransfer Multi-module – PowerwareHot Sync – redundant Multi-module – PowerwareHot Sync-capacityApplications Data centers Server farms Telecommunicationinstallations Internet service providers Transportation systems Security operations Broadcastingand entertainment Process control equipment Financial systems Credit card operations Medical / healthcare Industrial systems2EATON Eaton 9315 UPS

UPS ModuleBypass ContactorBypassInput(3 or 4 wire)UTILITY SOURCE INPUT480VAC-3F-3W-GND-60HZBYPASS SOURCE CircuitBreakerRectifierInverterRectifierInput(3 OutputFusing ContactorOutputIsolationTransformerMIBIntelligent Input FilterUPSOutput(3 or 4 Input Transformer225-500 kVAFeatures and on technology ouble-conversion online technology protects the criticalDload from any power variations on the inputDC Expert onitors and maintains battery health; provides state-of-chargeMand dynamically updates battery time remaining informationNetwork accessCRITCAL LOAD OUTPUT480/277VAC-3F-4W-GND-60HZ625-750 kVA ptional adapters provide LAN connectivity andOSNMP compatibilityRemote notifyFORESEERUPS initiates outcall for user-selected eventsFORESEER Enterprise Management System is the ultimatesolution to proactively monitor and manage critical facilityinfrastructure. Regardless of manufacturer, from UPSs, airhandlers and battery monitoring to simple temperature/humiditysensors, FORESEER monitors them all. Its interface capabilityand unparalleled performance analysis tools deliver the informationyou need to identify dangerous trends, execute corrective actionand prevent failures. Information comes across clearly and intuitivelyvia the most advanced graphical user interface.Intelligent input rovides superior generator interface and additional isolationPbetween input and outputIntelligent design educed component count significantly reduces singleRpoint-of-failureMonitor panel rovides single-button controls to easily access data aboutPUPS statusIntelligent controls with DSPDigital signal processing provides more pristine output signalTrue PWM technologyIntelligent Input FilterThe Intelligent Input Filter on the 9315 mitigates the damagingeffects of harmonics, and automatically turns itself off whenconditions dictate, such as when the power source switchesfrom utility to auxiliary generator power. Because it automaticallyconfigures itself, and turns itself on/off, you can be assured thatyour critical systems are protected, no matter what power anomalycomes their way. igh speed DSP enables IGBTs to work at their highestHcapacity, increasing system reliability and ensuring perfectpower on the outputPowerware Hot SyncPatented paralleling technology requires no communicationbetween modules, eliminating a system-level single point-of-failure;available for both redundant and capacity systems.EATON Eaton 9315 UPS3

Eaton 9315 (225-300 kVA)Shown with doors removed1 Monitor panelFull size liquid crystal displayprovides graphical performancedata, statistics, alarm historyand metering12 Control panelEasy-to-use control panel provides: One button start-up(with optional battery breaker)2 Bypass transfer control Input circuit breakeroperation3 Communication panelExternal communication interfaceaccommodates remote monitoringand configuration by network ordirect connection: Internal modem option,powered by the UPS System monitoring and controlfrom any location through:– RRS-232 and accessory ports– Remote terminal capabilities– X-slot cards3 UPS remote controlcapability via programmablebuilding alarmsEaton 9315 (225-300 kVA) Large, easy-to-readLCD measures 7.5" x 6"(191mm x 152mm) Push-button controlsallow easy access todata through user-friendlyWindows interface DC Expert providesstate-of-charge anddynamically updatesbattery time remaining4EATON Eaton 9315 UPS Operational meteringfeatures:–T rue RMS sensing ofvoltage and current– Real-time display–D isplays up to 400 of themost recent events; all datais accessible via modem Unique system performancestatistics include summaryinformation on:– UPS and bypass availability–F requency and length ofon-battery conditions– Building alarms–T ime on bypass, andmuch more

Eaton 9315 (225-300 kVA)Shown with safety shields removed1 Redundant power supplies support control logic for reliableonline operation and provide local and remote failure notification2 I ntelligent controls incorporating digital signal processingprovide 5 percent output THD, 1 percent output voltageregulation, programmable operating limits and failure-proofmake-before-break bypass transfers13 Static switch assembly can be removed for servicing withoutinterrupting the critical load; all electrical connections featurequick disconnects for safe access24 Standard dual feed inputs for 480V and 400V increase availability(optional for other voltages)45 2x-rated neutral supports higher currents associated withnon-linear loads36 Intelligent Input Filter disconnects from rectifier input with lossof utility and low load conditions, providing superior generatorcompatibility47 Mechanical connectors on all input and output terminals reduceinstallation time58 R edundant fans ensure direct consistent cooling and quietoperation and provide local and remote failure notification whilesupporting operational full rating up to 5000 without derating9 M odular design and construction places all serviceablecomponents within a 12" (305mm) depth for easy maintenance;only requires front access for servicing convenience and lowmean time-to-repair7610 Nine-inch removable wireway sections aid in installation8912" (305mm)10 Intelligent alarmmanagement-eventrecord separatesinformational noticesfrom situations requiringoperator intervention In addition to the LCD panel,LEDs indicate UPS operatingstatus at a glance A hinged access coverprotects an emergencypower-off (EPO) that quicklyde-energizes the UPS andcritical load A ll power wiring is secured tomagnetics with maintenancefree, cold-weldedconnections, eliminatingperiodic retorquing offasteners and rear accessrequirements S tandard top or bottomentry allows for installationflexibility–9 315 (200-300 kVA) reducesfrom 65" (1654mm) to56" (1422mm)–9 315 (300-500 kVA) reducesfrom 74" (1880mm) to65" (1654mm)EATON Eaton 9315 UPS5

Eaton 9315 (625-750 kVA)Internal viewModule bypass cabinetThis cabinet is only for reverse transfer systemsEaton 9315 (625-750 kVA)Uninterruptible Power SystemABC Company, UPS #11 SEPT 199612:00:00Uninterruptible Power SystemABC Company, UPS #1System NormalAlarm: NoneNotice: EventsMimicHistoryActive1 SEPT 1996Event History 12011:30:00.12011:30:00.0System NormalAlarm: NoneNotice: 15:00.115:15:00.012:00:00Event DescriptionStatus – System NormalCommand – Start SwitchCommand – Mode Switch to NormalStatus – On Manual BypassCommand: Mode Switch to Manual BypassStatus – System NormalCommand – Start SwitchCommand – Mode Switch to NormalStatus – On Manual BypassCommand: Mode Switch to Manual BypassMetersEventsMimic screen6EATON Eaton 9315 UPSStatisticsGraphicsSet UpMetersEventsStatisticsEvent history logGraphicsSet Up

Eaton 9315-750The 9315-750 expands the 9315 family to include a single module750 kVA UPS. The 9315-750 includes: 12-pulse rectifier High efficiency High speed PWM IGBT inverter Input isolation transformer Multi-module systemsInput/Rectifier Section Top cable entry and dedicated wireway area (shown withoutcover panel) Motor-operated input circuit breaker automatically opens/closesas required to transfer to and from all operational modes Optional inrush current limiter limits the inrush current to100 percent of the UPS module rated current Communication panel is an easy-to-use control panel providing:– One button start-up (with optional battery breaker)– Bypass transfer control– Input circuit breaker operation Optional Intelligent Input Filter disconnects from rectifier inputwith loss of utility and low load conditions, providing superiorgenerator compatibilityOutput/Inverter Section High-speed IGBT, PWM inverter section Redundant fans ensure direct consistent cooling, quiet operationand provide local and remote failure notification Motor operated output circuit breaker automatically opens/closesas requiredUninterruptible Power SystemABC Company, UPS #1System NormalAlarm: NoneNotice: NoneBatteryRunTime15:00UnitEvents12:00:00Start Date: 01 JUL 96Number of Incidents:StatisticsMeters1 SEPT 1996StatisticsTime On:DAYSHRMINOn Battery 1 Min.420UPS01480330On Battery1-4 Min.15Bypass00000004On Battery 4 Min.02Battery00000012Full Battery Discharge00Generator 00000000Building Alarm 101Logic0345On Generator12Building Alarm 300Building Alarm 412AvailabilityGo to Bypass00UPS1.00Building Alarm 601Bypass0.99GraphicsMonth Total0148Set UpStatistics screenEATON Eaton 9315 UPS7

DC Expert battery management (200-500 kVA)DC Expert provides real-time information on battery string healthand battery runtime remaining. With this integral feature, you alwaysknow the condition of your battery string. Most importantly, DCExpert allows you to plan for battery maintenance and avoidRectifierDC LinkInverterany unexpected load losses due to battery deterioration. DCExpert’s battery test method outperforms the competition. Compareits battery test method to the method used by other manufacturers,and see for yourself how DC Expert’s technique offers the highestlevel of assurance and battery runtime accuracy.During the battery test, therectifier regulates DC linkvoltage to obtain consistentbattery power dischargemonth to month.BypassRectifierDC Expert battery test methodOther UPS manufacturers’ battery test methods Consistent testing proactively provides battery runtimeinformation, accurate to /-3 percent Other UPS manufacturers turn off the rectifier to initiatebattery testing During a utility outage, battery time remaining automaticallyupdates with load shedding The battery fully supports the inverter load Battery string health determined during periodic testing Programmable, automatic monthly testing, any day, any time The monthly battery tests perform very light battery discharges,removing less than 10 percent of available battery runtime, toensure you are always ready for a utility outage Light load testing does not impact battery life Rectifier does not turn off during battery testing; rectifier sharesload with battery for consistent battery load testing regardless ofinverter load Since the rectifier does not turn off, the critical load is never atrisk during battery testing. If a battery should fail during the test,the system will recover 100 percent. DC Expert log stores results of last 30 tests for trending analysis Accommodates either valve regulated (“maintenance-free”) orwet cell batteries8InverterEATON Eaton 9315 UPS As the critical load changes from test to test, so does thebattery load Inconsistent battery test load yields inaccurate batteryruntime estimates If the battery fails during testing, the inverter must performan emergency transfer to bypass to prevent dropping thecritical load

With the world teeming with technology that must run 24/7, 365 days a year, it’s nosurprise that power protection has been elevated from a dusty corner in the basementto an integral and sophisticated part of an organization’s overall technology infrastructure.The 9315 offers a variety of power systems designed to integrate with your technologyand meet your availability requirements.Powerware Hot Sync technologyPowerware Hot Sync-redundantToday, your critical loads demand even greater protection.That’s why we developed a unique paralleling system thatprovides redundancy and capacity capability with high 9’ssystem availability.This two-module system provides unmatched system reliabilityand availability. This configuration allows full maintenance tobe performed on both modules and the parallel cabinet withoutneed for an external maintenance bypass and without having toremove the critical load from conditioned power. No other UPSmanufacturer can provide this capability.While you may be familiar with paralleling, the patentedPowerware Hot Sync’s technology eliminates more risks to yoursystem. Typically, in order for modules to operate in parallel asa system, they must communicate with each other throughintricate wiring to coordinate the primary paralleling operationsof output synchronization, load sharing and selective tripping of amodule. But this traditional method of communication introducesa system-level single point-of-failure. If this communication linkgoes down; or a master controller fails, so does your critical load.And that’s a risk you just can’t afford to take.Powerware Hot Sync-capacityThis system topology can accommodate up to eight modulesin parallel for your larger and most critical applications. Superiormonitoring and highly automated controls make this system aseasy to operate as a single module system.Instead, Powerware Hot Sync technology eliminates the needfor the modules to communicate with each other. Each UPSmodule has the ability to synchronize and support the criticalload independent of the other modules. This unique approachto paralleling completely eliminates the traditional singlepoint-of-failure.Module 1Battery 1Battery 2MODULE 1MODULE 2MODULE 3MODULE 4MODULE 5MODULE 6Optional Source CMODULE 7Optional Source BMODULE 8Source AModule 2FBPCBPSYSTEMBYPASSMODULECBSMOB 1Parallel CabinetSYSTEMMAINTENANCEBYPASS(OPTIONAL)MOB 2MISMBPCritical LoadCRITICAL LOADPowerware Hot Sync-redundant(225-500 kVA modules)Powerware Hot Sync-capacity(225-750 kVA modules)EATON Eaton 9315 UPS9

You may not require this level of reliabilitynow, if you are just purchasing a single UPSmodule. However, after the purchaseyou can effortlessly expand from a singlemodule system to a two-module PowerwareHot Sync redundant system and on to aneight-module Powerware Hot Sync capacitysystem. Isn’t it reassuring to know that the9315 provides this degree of scalability –if you need it?Powerware Sync Control TechnologyEnabling the uninterrupted transfer of critical loads from one sourceto another requires the sophistication of Powerware Sync ControlTechnology. This optional feature facilitates the synchronization oftwo totally separate UPS system outputs (whether they are singlemodule or Powerware Hot Sync capacity systems). Through aseries of downstream solid-state transfer switches, PowerwareSync Control Technology automatically transfers the critical loadfrom one UPS system to another. Because Powerware Sync ControlTechnology ensures that the outputs remain in phase with oneanother, should a scheduled or unscheduled maintenance eventoccur, there is peace-of-mind in the fact that all critical loads will besupported by UPS-grade power, 24/7, 365 days a year. PowerwareSync Control Technology also provides remote monitoring of thecontrol operation and alarms.Powerware Hot Tie TechnologyPowerware Hot Tie Technology is an ideal solution when there aretwo UPS systems powering two separate loads. Hot Tie allows youto transfer the load of one unit to the other, so that the loads arealways protected.Powerware Hot Tie Technology has become more important thanever with the development of Powerware Hot Sync Technology. HotTie Technology enables two systems, whose units are paralleledwith Powerware Hot Sync Technology, to be together for an evengreater level of redundancy and protection.Powerware Hot Tie works in four modes:1. Normal mode – the tie is open, output is synced to bypass2. Parallel mode – the tie is closed, output is synced to one ofthe UPS bypassesInput Source3. Combined load mode – the tie is closed, one UPS is operating(service mode)Input SourceSBM-ASBM-B4. System isolation mode – the tie is open, loads and UPS areremoved from the isolated load bus5. A utomatic mode – the tie is continuously available, dualpower path redundancy is always present and not limited toscheduled maintenancePowerwareSyncControlBypassSourceTo Critical Load – AStatic Transfer SwitchPowerware Sync Control(225-750 kVA modules)10EATON Eaton 9315 UPSBypassSourceTo Critical Load – BStatic Transfer Switch

AccessoriesService PlansMaintenance bypass module (MBM)The 9315 is supported by Eaton's comprehensive service plansto provide you with system uptime, convenience, and value. Wesupport the UPS, batteries, and related equipment with remotemonitoring and onsite services to meet your specific site orapplication needs. Our Customer Reliability Center is open sevendays a week, 24 hours a day to monitor your systems and respondto your needs. Our factory-trained service technicians are deployedacross the world to deliver speedy, reliable services.This floor-mounted, enclosed cabinet provides continuous supportfor critical loads during servicing or testing of the UPS module.The MBM includes the maintenance isolation breaker (MIS) andmaintenance bypass breaker (MBP).Power distribution module (PDM)The PDM provides distribution of output power from theUPS to critical applications. Each PDM includes two panels,each containing 42 poles that can be assigned dependingupon application requirements. If additional distribution isrequired, these cabinets can be daisy-chained to increasedistribution capacity.Remote monitor panel (RMP)The RMP allows customers to monitor the operational status ofthe UPS system from virtually any location within a facility. TheRMP uses simple backlit status indicators and an alarm hornto notify customers of changes in the operational status of theUPS system. This option can be installed in multiple locationsthroughout a customer's facility.Relay interface module (RIM)The RIM provides a critical communications link to optimizereliability, uses serial interface and relay contact closures tosupport up to eight critical loads. The RIM notifies customersof operational status changes, allowing them to respond withthe appropriate action.Additional service offerings– Installation and project management–C omplete line of power system maintenance plans (coveringparts and labor) to match an

power protection system with the most advanced technology. The 24/7 world is nothing new to us. For more than 40 . battery testing . Battery string health determined during periodic testing Programmable, automati

Related Documents:

Power Xpert 9395P UPS 750 kVA - 900 kVA and 1000 kVA - 1200 kVA User's and Installation Guide. P-164000477 9395P 750 kVA - 900 kVA and 1000 kVA - 1200 kVA 4 Revision 003 User's and Installation Guide IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

P-164000477 9395P 750 kVA - 900 kVA and 1000 kVA - 1200 kVA 3 Revision 003 User’s and Installation Guide Power Xpert 9395P UPS 750 kVA - 900 kVA and 1000 kVA - 1200 kVA

Kva-Amps Kva-Amps Kva-Amps Kva-Amps Kva-Amps Kva-Amps Kva-Amps Kva-Amps Kva-Amps Kva-Amps 1 .05 J050A1EA1A01 -0.43 1.88 0.48 2.08 0.96 4.16 1.00 4.38 0.53 2.29 1 .05 J050A1EB1A01 0.31 1.36 0.36 1.56 -0.72 3.12 0.77 3.34 0.41 1.77 1 -.10 J100A1EA1A01 -0.86 3.75 0.96 4.17 1.92 8.33 2.01 8.75 1.05 4.58 1 .10 0 .

DRY-TYPE (VPI) DISTRIBUTION TRANSFORMERS (Indoor and Outdoor). Tech Spec. No. CE/T-QC/MSC/Dry Type Dist Transformer dtd.08.10.2020 Page 7 6.4 Coreclamping: a. M.S channel 125 mm x 65 mm for 100 &200 kVA, 150 x 75 mm for 315 & 630 kVA transformer and 200 X 75 mm for 1000 kVA ,1250 KVA , 1600 Kva,2000 KVA &2500 KVA transformers on Top and Bottom.

Three-phase 120/240VAC @ 0.8pf (kW/kVA) 220 kW / 275 kVA Amps: 662 200 kW / 250 kVA Amps: 601 Three-phase 277/480VAC @ 0.8pf (kW/kVA) 220 kW / 275 kVA Amps: 331 200 kW / 250 kVA Amps: 301 * Circuit breaker limited STARTING CAPABILITIES (sKVA) sKVA vs. Voltage Dip 208 VAC 480 VAC Standard TBA TBA

2” & 3” aIr dIaPHragM PuMP 10 12’ / 24’ road CrossIng ManIfold 11 20”/24” CoPPus fan aIr MoVer 11 aIr Horns 11 ContaInMent BerM 11 8’ x 16’ eCoMats 12 25 kVa PortaBle generator 13 45 kVa PortaBle generator 13 85 kVa PortaBle generator 13 125 kVa PortaBle generator 14 150 kVa PortaBle generator 14 220 kVa PortaBle generator 14

Symmetra LX Rack-mount UPS Symmetra LX Tower UPS Symmetra LX Rack-mount Extended Run Symmetra LX Tower Extended Run Symmetra LX Operations Guide For use with Symmetra LX UPS Models: 200 V, 4-8 kVA 208/240 V, 4-8 kVA 220/230/240 V, 4-8 kVA 200 V, 4-16 kVA 208/240 V, 4-16 kVA 220/230/240 V, 4-16 kVA 990-1546A-001 06/2005

ible three-phase UPS. Available in single mod-ules from 225 kVA to 750 kVA, the 9315 can be paralleled for both redun-dancy and capacity using patented Powerware Hot Sync technology, for systems up to 3324 MW. More than just the workhorse for data centers, facilities and network solutions, the 9315 UPS uses intelligent communi-