PXIe-5775 Getting Started Guide - National Instruments

2y ago
54 Views
2 Downloads
640.74 KB
16 Pages
Last View : 16d ago
Last Download : 3m ago
Upload by : Brenna Zink
Transcription

GETTING STARTED GUIDEPXIe-577512-Bit, 6.4 GS/s, 2-Channel PXI FlexRIO DigitizerNote Before you begin, install and configure your chassis and controller.This document explains how to install, configure, test, and use the PXIe-5775. You canprogram the PXIe-5775 with the following software options. FlexRIO Support driver software NI LabVIEW Instrument Design Libraries for FlexRIO (instrument design libraries)Note Adapter modules are not installable or interchangeable on PXIe-5775devices.Caution This icon denotes a caution, which advises you to consult documentationwhere this symbol is marked.ContentsFlexRIO Documentation and Resources.2Verifying the System Requirements.2Unpacking the Kit. 3PXIe-5775 Kit Contents.3Preparing the Environment. 4Installing the Software and Driver. 4Installing the PXIe-5775. 5PXIe-5775 Front Panel and Pinout. 6Configuring the PXIe-5775 in MAX. 9FlexRIO Examples. 10Accessing FlexRIO Examples. 10Block Diagram. 10Component-Level Intellectual Property (CLIP). 12Making a Measurement.12Making a Measurement with LabVIEW. 12Troubleshooting. 13What Should I Do if the PXIe-5775 Doesn't Appear in MAX?.13What Should I Do if the PXIe-5775 Fails the Self-Test?.13Where to Go Next. 13Worldwide Support and Services. 14

FlexRIO Documentation and ResourcesTable 1. FlexRIO Documentation and 5775 GettingStarted Guide (thisdocument)Available from the Start menu Contains installation instructionsand at ni.com/manuals.and basic programming instructionsfor your PXIe-5775.PXIe-5775SpecificationsAvailable from the Start menu Contains specifications for yourand at ni.com/manuals.PXIe-5775.LabVIEW FPGAModule HelpEmbedded in LabVIEW Helpand at ni.com/manuals.FlexRIO HelpAvailable from the Start menu Contains information about theand at ni.com/manuals.FPGA module front panelconnectors and I/O, programminginstructions, and I/O componentlevel IP (CLIP).LabVIEW ExamplesAvailable in NI ExampleFinder. In LabVIEW, clickHelp»Find Examples»Hardware Input andOutput»FlexRIO.Contains examples of how to runFPGA VIs and Host VIs on yourdevice.IPNetLocated at ni.com/ipnet.Contains LabVIEW FPGAfunctions and intellectual propertyto share.FlexRIO product page Located at ni.com/flexrio.Contains information about thebasic functionality of the LabVIEWFPGA Module.Contains product information anddata sheets for FlexRIO devices.Verifying the System RequirementsTo use the PXIe-5775, your system must meet certain requirements. For more informationabout minimum system requirements, recommended system, and supported applicationdevelopment environments (ADEs), refer to the readme, which is available on the softwaremedia or online at ni.com/updates.2 ni.com PXIe-5775 Getting Started Guide

Unpacking the Kit1.2.Notice To prevent electrostatic discharge (ESD) from damaging the device, groundyourself using a grounding strap or by holding a grounded object, such as yourcomputer chassis.Touch the antistatic package to a metal part of the computer chassis.Remove the device from the package and inspect the device for loose components or anyother sign of damage.Notice Never touch the exposed pins of connectors.Note Do not install a device if it appears damaged in any way.3.Unpack any other items and documentation from the kit.Store the device in the antistatic package when the device is not in use.PXIe-5775 Kit ContentsThe following items are included in the device kit: The PXIe-5775 The FlexRIO driver software media Documentation:–Maintain Forced-Air Cooling Note to Users–PXIe-5775 Getting Started Guide (this document)PXIe-5775 Getting Started Guide National Instruments 3

Preparing the EnvironmentEnsure the environment in which you are using the PXIe-5775 meets the followingspecifications.Operating environmentAmbient temperature range0 C to 55 C1 (Tested in accordance withIEC-60068-2-1 and IEC-60068-2-2. MeetsMIL-PRF-28800F Class 3 low temperaturelimit and MIL-PRF-28800F Class 2 hightemperature limit.)Relative humidity range10% to 90%, noncondensing (Tested inaccordance with IEC 60068-2-56.)Maximum altitude2,000 m (800 mbar) (at 25 C ambienttemperature)Pollution Degree2Indoor use only.Note For complete specifications, refer to the specifications document for yourdevice at ni.com/manuals.Installing the Software and DriverBefore installing your hardware, you must install the application software and instrumentdriver. Visit NI FlexRIO Driver Supported Versions for FlexRIO Adapters and Modules todetermine which minimum software versions you need for your device. Install the software inthe following order:1. Install LabVIEW.Refer to the LabVIEW Installation Guide for installation instructions for LabVIEW andsystem requirements for the LabVIEW software. Refer to the LabVIEW Upgrade Notesfor additional information about upgrading to the most recent version of LabVIEW forWindows. Documentation for LabVIEW is available at ni.com/manuals.2.Install the LabVIEW FPGA Module.Refer to the LabVIEW FPGA Module Release and Upgrade Notes for installationinstructions and information about getting started with the LabVIEW FPGA Module.Documentation for the LabVIEW FPGA Module is available at ni.com/manuals.3.(Optional) Install the LabVIEW Real-Time Module.14 The PXIe-5775 requires a chassis with slot cooling capacity 58 W. Not all chassis with slotcooling capacity 58 W can achieve this ambient temperature range. Refer to the PXI ChassisManual for specifications to determine the ambient temperature ranges your chassis can achieve.ni.com PXIe-5775 Getting Started Guide

Refer to the LabVIEW Real-Time Module Release and Upgrade Notes for systemrequirements, installation instructions, and additional information about using theLabVIEW Real-Time Module.4.Install FlexRIO.Refer to the FlexRIO Readme for system requirements and installation instructions forFlexRIO. Documentation for FlexRIO is available at ni.com/manuals.Installing the PXIe-57751.Notice To prevent damage to the PXIe-5775 caused by ESD or contamination,handle the module using the edges or the metal bracket.Ensure the AC power source is connected to the chassis before installing the module.The AC power cord grounds the chassis and protects it from electrical damage while youinstall the module.2.Power off the chassis.3.Inspect the slot pins on the chassis backplane for any bends or damage prior toinstallation. Do not install a module if the backplane is damaged.4.Remove the black plastic covers from all the captive screws on the module front panel.5.Identify a supported slot in the chassis. The following figure shows the symbols thatindicate the slot types.Figure 1. Chassis Compatibility SymbolsNI PXIe-1062Q1. PXI Express System Controller Slot2. PXI Peripheral Slot3. PXI Express Hybrid Peripheral Slot123544. PXI Express System Timing Slot5. PXI Express Peripheral SlotPXIe-5775 modules can be placed in PXI Express peripheral slots, PXI Express hybridperipheral slots, or PXI Express system timing slots.6.Touch any metal part of the chassis to discharge static electricity.7.Ensure that the ejector handle is in the downward (unlatched) position.8.Place the module edges into the module guides at the top and bottom of the chassis. Slidethe module into the slot until it is fully inserted.PXIe-5775 Getting Started Guide National Instruments 5

Figure 2. Module Installation1NIPXIe-1075231. Chassis2. Hardware Module3. Ejector Handle in Downward (Unlatched) Position9.Latch the module in place by pulling up on the ejector handle.10. Secure the module front panel to the chassis using the front-panel mounting screws.Note Tightening the top and bottom mounting screws increases mechanicalstability and also electrically connects the front panel to the chassis, which canimprove the signal quality and electromagnetic performance.11. Cover all empty slots using EMC filler panels or fill using slot blockers to maximizecooling air flow, depending on your application.12. Power on the chassis.PXIe-5775 Front Panel and PinoutPXIe-5775 Front PanelThe following figure shows the PXIe-5775 front panel.6 ni.com PXIe-5775 Getting Started Guide

Figure 3. PXIe-5775 Front PanelPXIe-5775FlexRIO DigitizerDIO12-Bit, 6.4 GS/s4 VppMAXAI 0AI 14 VppMAXREF/CLK INThe following table describes the signal connections for the PXIe-5775.PXIe-5775 Getting Started Guide National Instruments 7

ConnectorDescriptionFunctionDIOMolex Nano-Pitch DIOconnectorMulti-signal DIO connector that providesaccess to FPGA multi-gigabit transceivers(MGTs) and general-purpose LVCMOSsignals.AI 0Standard SMA femaleconnectorAnalog input connection.AI 1REF/CLK IN Standard SMA femaleconnectorInput for an external Reference Clock orSample Clock.Digital I/O PinoutThe following figure shows the Digital I/O (DIO) connector pinout.Figure 4. Digital I/O ConnectorReservedA1B15VGNDA2B2GNDMGT Rx 0A3B3MGT Tx 0MGT Rx– 0A4B4MGT Tx– 0GNDA5B5GNDMGT Rx 1A6B6MGT Tx 1MGT Rx– 1A7B7MGT Tx– 1GNDA8B8GNDDIO 4A9B9DIO 6DIO 5A10 B10DIO 7GNDA11 B11GNDDIO 0A12 B12DIO 2DIO 1A13 B13DIO 3GNDA14 B14GNDMGT Rx 2A15 B15MGT Tx 2MGT Rx– 2A16 B16MGT Tx– 2GNDA17 B17GNDMGT Rx 3A18 B18MGT Tx 3MGT Rx– 3A19 B19MGT Tx– 3GNDA20 B20GND5.0 VA21 B21ReservedThe following table lists the available pins on the DIO connector.8 ni.com PXIe-5775 Getting Started Guide

SignalTypeDirectionMGT Tx 0.3 2Xilinx UltraScale GTHOutputMGT Rx 0.3 2Xilinx UltraScale GTHInputDIO 0.7 Single-endedBidirectional5.0 VDCOutputGNDGround—Notice The maximum input signal levels are valid only when the module ispowered on. To avoid permanent damage to the PXIe-5775, do not apply a signal tothe device when the module is powered down.Notice Connections that exceed any of the maximum ratings of any connector onthe PXIe-5775 can damage the device and the system. NI is not liable for anydamage resulting from such connections.Configuring the PXIe-5775 in MAXUse Measurement & Automation Explorer (MAX) to configure your NI hardware. MAXinforms other programs about which NI hardware products are in the system and how they areconfigured. MAX is automatically installed with FlexRIO.1. Launch MAX.2.In the configuration tree, expand Devices and Interfaces to see the list of installed NIhardware.Installed modules appear under the name of their associated chassis.3.Expand your Chassis tree item.MAX lists all modules installed in the chassis. Your default names may vary.Note If you do not see your module listed, press F5 to refresh the list ofinstalled modules. If the module is still not listed, power off the system, ensurethe module is correctly installed, and restart.4.Record the identifier MAX assigns to the hardware. Use this identifier whenprogramming the PXIe-5775.5.Self-test the hardware by selecting the item in the configuration tree and clicking SelfTest in the MAX toolbar.The MAX self-test performs a basic verification of hardware resources.2MGTs are available only on devices with KU040 and KU060 FPGAs.PXIe-5775 Getting Started Guide National Instruments 9

FlexRIO ExamplesFlexRIO includes several example applications for LabVIEW. These examples serve asinteractive tools, programming models, and as building blocks in your own applications.Accessing FlexRIO ExamplesFlexRIO examples are available in LabVIEW's NI Example Finder. Complete the followingsteps to access the examples by task.1. In LabVIEW, click Help»Find Examples.2.In the NI Example Finder window that appears, click Hardware Input and Output»FlexRIO.The examples are sorted by task. Click on an example and refer to the Informationwindow for a description of the example. Refer the Requirements window for a list ofhardware devices that can run the example.You can also click the Search tab to search all installed examples by keyword. Forexample, search for FlexRIO to locate all FlexRIO examples.Examples also are available online that demonstrate FlexRIO basics, such as using DRAM,acquiring data from adapter modules, and performing high throughput streaming. Refer toni.com/examples for these examples and for more information.Block DiagramThe following figure shows a block diagram of the carrier portion of the PXIe-5775 (KU035FPGA option).10 ni.com PXIe-5775 Getting Started Guide

Figure 5. Carrier Block Diagram (KU035) 12 V 5 V 12 V, 3.3 VFlashGen3 x8 PCIeGPIOAdapter ModuleConnector 1.8 V 12 VDStarB, DStarCPXI TriggersFPGAClk 100Configuration, GPIOMGTsPXIe ConnectorsDIO Connector(Front Panel)Power SuppliesClk 10Module ClockingSynchronizationReference ClockThe following figure shows a block diagram of the carrier portion of the PXIe-5775 (KU040and KU060 FPGA options).Figure 6. Carrier Block Diagram (KU040 and KU060) 12 V 5 V 12 V, 3.3 VFlashGen3 x8 PCIeGPIODStarB, DStarCMGTsAdapter ModuleConnector 1.8 V 12 VFPGAPXI TriggersClk 100Configuration, GPIOMGTsPXIe ConnectorsDIO Connector(Front Panel)Power SuppliesClk 10Module ClockingSynchronizationDRAM Bank 0(2 GB)DRAM Bank 1(2 GB)Reference ClockThe following figure shows a block diagram of the I/O portion of the PXIe-5775.PXIe-5775 Getting Started Guide National Instruments 11

Figure 7. PXIe-5775 Block DiagramADC12DJ3200Dual 12-bit, 3.2 GS/sSingle 12-bit, 6.4 GS/sANALOG INPUTAI0 SMAAC (Balun)Coupled PathAdapter ModuleConnectorAI1 SMAAC (Balun)Coupled PathEXTERNAL REF/SCLKCLK IN SMACLOCKINGComponent-Level Intellectual Property (CLIP)The LabVIEW FPGA Module includes component-level intellectual property (CLIP) for HDLIP integration. FlexRIO devices support two types of CLIP: user-defined and socketed. User-defined CLIP allows you to insert HDL IP into an FPGA target, enabling VHDLcode to communicate directly with an FPGA VI. Socketed CLIP provides the same IP integration of the user-defined CLIP, but it alsoallows the CLIP to communicate directly with circuitry external to the FPGA. Adaptermodule socketed CLIP allows your IP to communicate directly with both the FPGA VIand the external adapter module connector interface.The PXIe-5775 ships with socketed CLIP items that add module I/O to the LabVIEW project.Making a MeasurementMaking a Measurement with LabVIEW1.Launch LabVIEW.2.Select Help»Find Example.3.Open the example VI that you want to use by selecting Hardware Input and Output»FlexRIO.4.Follow any setup, configuration, and execution instructions in the VI.12 ni.com PXIe-5775 Getting Started Guide

TroubleshootingIf an issue persists after you complete a troubleshooting procedure, contact NI technicalsupport or visit ni.com/support.What Should I Do if the PXIe-5775 Doesn't Appear inMAX?1.In the MAX configuration tree, expand Devices and Interfaces.2.Expand the Chassis tree to see the list of installed hardware, and press F5 to refreshthe list.3.If the module is still not listed, power off the system, ensure that all hardware is correctlyinstalled, and restart the system.4.Navigate to the Device Manager.5.Operating SystemDescriptionWindows 10/8.1Right-click the Start button, and select Device Manager.Windows 7Select Start»Control Panel»Device Manager.Verify the PXIe-5775 appears in the Device Manager.a) Under an NI entry, confirm that a PXIe-5775 entry appears.b)Note If you are using a PC with a device for PXI remote control system,under System Devices, also confirm that no error conditions appear for thePCI-to-PCI Bridge.If error conditions appear, reinstall FlexRIO and the PXIe-5775.What Should I Do if the PXIe-5775 Fails the Self-Test?1.Restart the system.2.Launch MAX, and perform the self-test again.3.Power off the chassis.4.Reinstall the failed module in a different slot.5.Power on the chassis.6.Perform the self-test again.Where to Go NextRefer to the following figure for information about other product tasks and associatedresources for those tasks.PXIe-5775 Getting Started Guide National Instruments 13

Located using the NI Example FinderLocated online at ni.com/manualsEXPLORELEARNCREATEabout hardware featuresor review devicespecifications.the application developmentenvironment (ADE)for your application.custom applications withan application programminginterface (API).NI PXIe-4112PXIe-5775Specifications*Learn LabVIEW BasicsFlexRIO ModuleExamples*LabVIEW FPGAModule HelpFlexRIO Help*DISCOVERmore about your products through ervicesni.com/servicesNI Communityni.com/community*This item is also installed with the driver software.Worldwide Support and ServicesThe NI website is your complete resource for technical support. At ni.com/support, you haveaccess to everything from troubleshooting and application development self-help resources toemail and phone assistance from NI Application Engineers.Visit ni.com/services for information about the services NI offers.Visit ni.com/register to register your NI product. Product registration facilitates technicalsupport and ensures that you receive important information updates from NI.NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas,78759-3504. NI also has offices located around the world. For support in the United States,create your service request at ni.com/support or dial 1 866 ASK MYNI (275 6964). Forsupport outside the United States, visit the Worldwide Offices section of ni.com/niglobal toaccess the branch office websites, which provide up-to-date contact information.14 ni.com PXIe-5775 Getting Started Guide

PXIe-5775 Getting Started Guide National Instruments 15

Information is subject to change without notice. Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks forinformation on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of theirrespective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in yoursoftware, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can findinformation about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Referto the Export Compliance Information at ni.com/legal/export-compliance for the NI global trade compliance policy and how

PXIe-5775 12-Bit, 6.4 GS/s, 2-Channel PXI FlexRIO Digitizer Note Before you begin, install and configure your chassis and controller. This document explains how to install, configure, test, and use the PXIe-5775. You can pr

Related Documents:

GETTING STARTED GUIDE PXIe-1486 FlexRIO FPD-Link Interface Module . Connectors, and Block Diagram on page 14 PXIe-1486 SerDes Front Panel, Connectors, and Block Diagram on page 17 Configuring the PXIe-1486 in MAX Use Measurement & Automation Explorer (MAX) to configure your NI hardware. MAX

GETTING STARTED GUIDE PXIe-5831 Up to 44 GHz, 1 GHz Bandwidth, Vector Signal Transceiver Note Before you begin, install and configure your chassis and controller. This document explains how to install, configure, and test the PXIe-5831. The PXIe-5831 is a half-duplex RF communications instrument with up to 1 GHz of instantaneous bandwidth,

PXIe-5764 Kit Contents The following items are included in the device kit: The PXIe-5764 The FlexRIO Support driver software media Documentation: – Maintain Forced-Air Cooling Note to Users – PXIe-5764 Getting Started

NI PXIe-1073 chassis PXIe-chassis with 5 slots. Connected to the controller PC with a MXIe-link. In the current configuration there is a spare slot for future expansion. NI PXIe-6556/NI PXIe6570 Digital waveform generator/analyzer with PPMU capability. The PXIe-6570 replaced PXIe-6556 when it

CALIBRATION PROCEDURE NI PXIe-4464 4-Channel, 204.8 kS/s DSA Input This document contains the veri fication and adjustment procedur es for the National Instruments PXIe-4464. The NI PXIe-4464 is available in two input connector variants: BNC and mXLR. The calibration procedure is co mmon between them; only the connec ting cabling is different. In

5775 Flex 800 Solo 5775 NA KURTZ DESIGN 18.08.05 washable stop washable Contour 5775 Type 5738 Modèle 5738 Modelo 5738

GETTING STARTED GUIDE NI PXIe-5644R 6 GHz Reconfigurable RF Vector Signal Transceiver Note Before you begin, install and configure your chassis and controller. This document explains how to install, configure, and test the NI 5644R.

AGMA American Gear Manufacturers Association AIA American Institute of Architects. AISI American Iron and Steel Institute ANSI American National Standards Institute, Inc. AREA American Railway Engineering Association ASCE American Society of Civil Engineers ASME American Society of Mechanical Engineers ASTM American Society for Testing and .