Electrocardiograph ECG-2550Fully interpretive 12 and 15 lead resting ECG,with advanced features including Data Capture

CardiofaxGECG-2550Reliable, accurate &designed to performnnnFully interpretive 12 and15 lead resting ECGProvides more than 200findings with detailedanalysisRR interval test with heart ratevariability (HRV) analysisnData Capture preview systemnFour-year warranty

Advancing ECG Acquisition & AnalysisCapture the optimal ECG,before you select and printThe Data Capture System (DCS) of the CardiofaxGallows you to collect and store up to 10 minutes ofECG data, then scroll back to precisely select themost representative clinical ECG data to save foranalysis, interpretation, and physician review.nEliminates the need for costly retestingnIncreases efficiency and improves theclinical significance of the testData Capture System: Review. Select. Analyze.123Review up to 10 minutes of ECG data.Select the best test data.Analyze the selected test segment.Print report.Get more information from your ECG Exam —Introducing Synthesized 18 lead ECG*Developed by Nihon Kohden, SynECi-18 is aninnovative new technology that obtains 18 lead datafrom a standard 12 lead ECG. The additional 6 leads ofsynthesized data may help with the detection of ECGchanges that can be missed with conventional 12 leadtechnology, including invisible ischemia.* Not available for sale or use in theUnited States, pending FDA clearance.The synthesized 18 lead ECG derives the waveformsof the right chest leads (V3R, V4R, V5R) and posteriorleads (V7, V8, V9).

Simple & Intuitive OperationCustomizable, One-Click OperationsFunction keys and on-screen icons makeoperation easy and intuitive.Four customizable function keys simplify testingby assigning commonly used functions to a singletouch, speeding operation and aiding workflow.High-resolution, 15-inchtouch-screen displayThe display of the CardiofaxG is the same size asthe recording paper, showing actual size waveformson the screen.Built-in Ethernet and optional Wi-FiSimplify connection to leading cardiology platforms.On-Screen ToolsPatient ECG Exam ReferenceLead CheckPast 12 lead ECG exams, with physiciancomments, can be viewed on-screenduring subsequent tests.The limb and chest leads are checked for signalquality. Detailed guidance and error messagesare displayed on-screen.On-Screen Operation GuideFull 12 lead ECG procedure guide is quicklyaccessed to support technician efficiency.

Streamlined Set-up & OperationEasy lead connectionIndividual lead wires can be easilyexchanged. Different length leads areavailable to suit the exam environment.The input box also allows for 15 leadstudies, using optional lead wires.Lead wires and separators aredesigned to prevent tanglingand enable easy cleaning.Multiple clip options are available.Start/Stop button on input boxThe input box has a start/stop switchso the technician can also operate theCardiofaxG while near the patient.Swivel and tilt screenThe screen can be easily adjusted allowingthe technician to have complete access tothe display anywhere at the bedside.Space-saving tabletop designFlat printing surface makes it easyto add notes to tests and reports.

Nihon KohdenImproving the quality of life through advanced medical technologyRecognized worldwide as an innovator of medical technologies supporting the cycle of care.A market leader in patient monitoring, sleep diagnostics, neurology and cardiology instrumentation,Nihon Kohden products are used globally in hospitals, physician offices, mobile services, outpatientsettings, and surgery centers.CardiofaxMCardiofaxSSee our full line of ECGmodels at nkecg.comSpecificationsECG AcquisitionSensitivityInput impedanceCommon mode rejection ratioMeasurement modesSignal ProcessingAcquisition sampling rateAnalysis sampling rateAC interference filterTime constantHigh cut filterEMG filterDisplayTypeDisplay sizeResolutionData DisplayRecorderPrinting processNumber of channelsPaper speedRecording paper10 mm/mV 5%20 MΩ or more110 dB or moreStandard 12 lead, 15 lead or XYZ leadECG AnalysisProgram nameAnalysis timeRR Interval measurementPacemaker detectionFindingsJudgment categoriesECAPS 12C10 to 24 sec.YesYesapprox. 200516,000 samples/sec.Dimensions and WeightDimensions – inches500 samples/sec.50/60Hz 3.2 sWeight – Main unit75, 100, or 150Hz (-3dB)25 or 35Hz (-3dB)Power RequirementsPower line voltageType of protectionagainst electric shockColor Touchscreen (TFT LCD)15 inch1024 76812/15 lead ECG waveform, patientinformation, recording settings, operationmode, heart rate, QRS sync mark,CAL mark, electrode detachment, leadreversal, customizable help screensHigh resolution thermal print head3, 6, 12, or 15 channels5, 10, 12.5, 25, 50 mm/s210 or 216 mm width, 30 m long Z-foldor roll type210 or 216 mm width, 100 or 300 m longZ-fold or roll type, outside the instrumentDegree of protectionagainst electric shockAccessoriesBattery packPatient cable hangerSD memory cardWireless LAN converterBar code scannerOptionsTransport cart15.75” W 17.83” H 17.32” D(excluding protrusions)24 lbs(including battery, excluding other options)AC 100 V to 240 V (50, 60 Hz), 220 VACLASS I EQUIPMENT(AC Powered) Internally powered equipment(Battery Powered)Defibrillator proof type CF applied RNK-CART25www.nkecg.comNihon Kohen America, Inc.90 Icon, Foothill Ranch, CA 92610www.nkusa.com800.325.0283 949.580.1555 2013 Nihon Kohden. Cardiofax is a trademark of Nihon Kohden. SD is a trademark of SD-3C, LLC. ECG-2550A

Nihon Kohden products are used globally in hospitals, physician offices, mobile services, outpatient settings, and surgery centers. Specifications See our full line of ECG models at nkecg.com CardiofaxM CardiofaxS ECG Acquisition Sensitivity 10 mm/mV 5% Input impedance 20 M or more Common mode rejection ratio 110 dB or more

Related Documents:

is the professional s strongest need. Nihon Kohden is continuously striving to improve patient safety, reliability, and effectiveness. We feel this is our greatest responsibility. The ECG-2550 incorporates many details to improve the routine work of physicians. We developed the ECG-2550 with features to answer the needs of professionals.

CSR Report 2016 Improving Healthcare with Advanced Technology NIHON KOHDEN CSR Report 2016 1-31-4 Nishiochiai, Shinjuku-ku, Tokyo 161-8560, Japan . CSR plan. Under its Sustainable Growth 2017 mid-term CSR plan, Nihon Kohden set healthcare, the environment and corporate activities

standard for electrocardiographs. Noise is eliminated with no waveform distortion. Nihon Kohden’s ECAPS 12C ECG analysis program provides more than 200 findings with detailed analysis. Synthesized 18 lead ECG* From just the standard 12 lead, the difficult to

NB (NIHON BEARING) NIHON PILLOW BLOCK SEIZO (FYH) NIHON SKF NIHON TOKUSHU BEARING NMB (MINEBEA/KEIAISHA) NSK (NIHON SEIKO) NTN OILES KOGYO OZAK SEIKO SANKYO OILLESS KOGYO TOK BEARING Bearings Bushings Bearings Spacers Bearings Bearings Bearings Bearings Beari

Nihon Kohden Corporation Cardiofax, Lifescope, and Nihon Kohden Novarad Corporation NovaCardio and Novarad Physio-Control, Inc Physio-Control, LIFEPAK, and LIFENET SafeNet Data Security Ltd. HASP Schiller Holding AG CARDIOVIT ScImage, Inc ScImage and PICOM Shenzhen Mindray Bio -Medical Electronics, Inc. Mindray, BeneHeart, and BeneVision

DMS was designed to improve communication between staff members, facilitate scheduling, and provide quick access to information. At Nihon Kohden, we understand the demands and budgetary constraints of a sleep lab. We continue to develop our product to maximize efficiency and streamline work

a 12-lead ECG Recording a high-quality ECG is essential to ensure that interpretation of the ECG is correct. Errors that can occur in ECG recording include poor electrode contact and incorrect electrode positioning, which can lead to misinterpretation of the ECG and misdiagnosis. This guide to performing a standard 12-lead ECG recording

Anatomy 2-5 Indications 5 Contra-indications 5 General preparation 6 Landmarks 6-7 Performing the block 7-8 Complications 8 Trouble shooting 9 Summary 9 References 10 Appendix 1 11. 6/10/2016 Fascia Iliaca Compartment Block: Landmark Approach 2 FASCIA ILIACA COMPARTMENT BLOCK: LANDMARK APPROACH INTRODUCTION Neck of femur fracture affect an estimated 65,000 patients per annum in England in .