BURNDY Products Grounding TABLE OF CONTENTS

2y ago
113 Views
2 Downloads
8.95 MB
94 Pages
Last View : 1m ago
Last Download : 3m ago
Upload by : Tia Newell
Transcription

BURNDY ProductsGroundingTABLE OF CONTENTSHYGROUND IRREVERSIBLE COMPRESSION GROUNDINGAND INSTALLATION TOOLING HYGROUND FeaturesType YGIB . . . . . . . . . . E-20 - E-21and Benefits . . . . . . . . . E-5 - E-6E-1Type YGL-C . . . . . . . . . . . . . . . . E-7Type GSTUD-HY . . . . . . . . . . . E-22Type YGLR-C . . . . . . . . . . . . . . . E-8Types YGT & YTTAG . . . . . . . . E-23Type YGHP-C . . . . . . . . . . . . . . E-9Type YG-B . . . . . . . . . . . . . . . . E-24Type YGHP-C . . . . . . . . . . . . . E-10MECHANICAL GROUNDINGTypes KC, K2C . . . . . . . . . . . . E-25Type YGHC-C . . . . . . . . . . . . . E-11Types KC22J12T13,EQC632C, KS-DB . . . . . . . . . E-26Type YGC . . . . . . . . . . . . . . . . . E-12Types KS, GKA,KPB, CL50-1 . . . . . . . . E-26 - E-27Type YSHG . . . . . . . . . . . . . . . . E-13Type YGHR-C . . . . . . . . . . . . . E-14Type GAR . . . . . . . . . . . E-28 - E-29Type YGHR-C . . . . . . . . . . . . . E-15Types GAR-BU & GAR3900 Series & GAR-RB . . . . E-30Type YGHA . . . . . . . . . . . . . . . E-16Type GAR-TC . . . . . . . . . . . . . E-31Type YGHS . . . . . . . . . . . . . . . E-16LIGHTNING PROTECTION INFO.Type YGA . . . . . . . . . . . . . . . . . E-17Type YGS . . . . . . . . . . . . . . . . . E-18Type YGF . . . . . . . . . . . . . . . . . E-19Basic rules for selection are:1. Must be like material to the conductor.2. Two bolts to ground rod –– minimum, for mechanical.3. Cable to cable connections can be installed with – onebolt, two bolt, or compression.4. Cable to steel structure must have 8 in.2 contact with steel.5. Heavy duty stacks –– mechanical only.6. On all connectors with heavy duty stack rating, we mustoffer 1/16 thick lead plating as an option. Reason is closest 25 ft. to stack opening must use lead coated product.7. UL 96 Listing.Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY Products.US: 1-800-346-4175www.burndy.comCanada: 1-800-387-6487

BURNDY ProductsGroundingTABLE OF CONTENTSMECHANICAL GROUNDING (Continued)Type GD . . . . . . . . . . . . . . . . . . E-32Types GC, GCM . . . . . . . . . . . . E-47Type GP . . . . . . . . . . . . . . . . . . E-33Type GL . . . . . . . . . . . . . . . . . . E-48Type GK . . . . . . . . . . . . . . . . . . E-33Type GZ . . . . . . . . . . . . . . . . . . E-48Water Pipe Grounding . . E-34 - E-39Type GC-CT . . . . . . . . . . . . . . . E-49Type GC-A . . . . . . . . . . . . . . . . E-40Type GTC1AC34RA . . . . . . . . . E-50Type GG . . . . . . . . . . . . . . . . . . E-41Type GIE-G . . . . . . . . . . . . . . . E-51Type GQ . . . . . . . . . . . . . . . . . . E-42Rail Connector . . . . . . . . . . . . . E-52Type GX . . . . . . . . . . . . . . . . . . E-43Type QGFL . . . . . . . . . . . . . . . . E-53Types GRC, GRL, GCRT1/0 . . E-44Type GA-H . . . . . . . . . . . . . . . . E-53Type B . . . . . . . . . . . . . . E-45 - E-46Type GRF . . . . . . . . . . . . . . . . . E-54Raised Floor GroundingE-2Types GB, GBM . . . . . . . . . . . . E-47Types GP-G1, GPRT. . . . . . . . . E-55Raised Floor GroundingThroughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY Products.Canada: 1-800-387-6487www.burndy.comUS: 1-800-346-4175

BURNDY ProductsGroundingTABLE OF CONTENTSBURNDYWeld BURNDYWeld Introduction . . . . . . . . . . . . . . . . E-57Type BCR-17 . . . . . . . . . . . . . . E-69Type BCR-24 . . . . . . . . . . . . . . E-70BURNDYWeld Making aConnection . . . . . . . . . . . . . E-58Type BCS-1 . . . . . . . . . . . . . . . E-72WELD METAL . . . . . . . . . . . . . E-59Type BCS-8 . . . . . . . . . . . . . . . E-72Type BCC-1 . . . . . . . . . . . . . . . E-60Type BCS-2 . . . . . . . . . . . . . . . E-73Type BCC-2 . . . . . . . . . . . . . . . E-61Type BCS-9 . . . . . . . . . . . . . . . E-73Type BCC-4 . . . . . . . . . . . . . . . E-62Type BCS-3 . . . . . . . . . . . . . . . E-74Type BCC-11 . . . . . . . . . . . . . . E-63Type BCS-23 . . . . . . . . . . . . . . E-75Type BCC-6 . . . . . . . . . . . . . . . E-64Type BCS-4 . . . . . . . . . . . . . . . E-76Type BCC-14 . . . . . . . . . . . . . . E-64Type BCS-6 . . . . . . . . . . . . . . . E-76Type BCC-7 . . . . . . . . . . . . . . . E-65Type BCS-7. . . . . . . . . . . . . . . . E-77Type BCR-1 . . . . . . . . . . . . . . . E-66Type BCS-18 . . . . . . . . . . . . . . E-77Type BCR-2 . . . . . . . . . . . . . . . E-67Type BCS-5 . . . . . . . . . . . . . . . E-78Type BCR-3. . . . . . . . . . . . . . E-68Type BCRE-1 . . . . . . . . . . . . . . E-79Type BCRE-2 . . . . . . . . . . . . . . E-80Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY Products.US: 1-800-346-4175www.burndy.comCanada: 1-800-387-6487E-3

BURNDY ProductsGroundingTABLE OF CONTENTSBURNDYWeld (Continued)E-4Type BCRE-3 . . . . . . . . . . . . . . E-81Type BCR-24 . . . . . . . . . . . . . . E-71Type BCRE-4 . . . . . . . . . . . . . . E-82Type BCR-25 . . . . . . . . . . . . . . E-71Type BCRE-6 . . . . . . . . . . . . . . E-83ACCESSORIESB38-0330-00 Cable Clamp . . . E-90BURNDY GROUNDMAX . . E-84Cable Cleaning Brush . . . . . . . E-90BURNDY PrefabricatedWire Mesh . . . . . . . . . . . . . . E-86Types B-106 & B-107Handle Clamps . . . . . . . . . . E-88B40-0106-75Handle Attachment . . . . . . . E-88Card Cloth Brush . . . . . . . . . . . E-90Mold Cleaning Brush . . . . . . . . E-90Mold Cleaners . . . . . . . . . . . . . E-90Packing Material . . . . . . . . . . . E-90Mold Support Clamp . . . . . . . . E-88BURNDYWeld Tool Kit . . . . E-91Vertical MagneticClamps . . . . . . . . . . . . . . . . . E-89BURNDYWeld Tools . . . . . . E-91Horizontal & VerticalChain Clamps . . . . . . . . . . . E-89B38-0101-00 Rasp . . . . . . . . . E-91B38-0309-00 Flint Ignitor . . . . E-91SINGLE SHOT MOLDSType BCR-1 . . . . . . . . . . . . . . . E-71Type BCR-2 . . . . . . . . . . . . . . . E-71Ground RodDriving Sleeves . . . . . . . . . . E-92Shim Stock andAdapter Sleeves . . . . . . . . . . E-92Tips. . . . . . . . . . . . . . . . . E-93 - D94Canada: 1-800-387-6487www.burndy.comUS: 1-800-346-4175

BURNDY ProductsGroundingHYGROUND CompressionTHE HYGROUND IRREVERSIBLECOMPRESSIONSYSTEMBURNDY has developed an irreversiblecompression ground system which meetsthe most stringent safety and performancerequirements, including those of OSHA andnuclear power plant design. Performanceexcellence and long life expectancy are thesystem’s basic design guidelines. It is a complete system which consists of connectorsfor grid cross connections, taps, splices,cable to ground rod, ground plates and terminations.E-5Our irreversible compression ground connectors employ well-proven design principles and technology that have been in existence for over 60 years.Connectors are just one component of ourIrreversible Compression Ground System.Installation tooling is also an integral part ofthis system. BURNDY pioneered the compression connector principle and continuestoday to be the leader in compression technology. Our tooling package is the mostextensive in the industry and affords the usermany options.Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY Products.US: 1-800-346-4175www.burndy.comCanada: 1-800-387-6487

BURNDY ProductsGroundingHYGROUND CompressionTHE HYGROUND s and Benefits Irreversible compression.〫 Meets 1999 NEC code, section 250-50and 250-64. Material-pure wrought copper extrusions,rod and seamless tubing––identicalmaterial to the conductor.〫 Completely eliminates the possibility ofcorrosion due to dissimilar metals. Heavy duty connector design.〫 All connectors will carry the equivalentor greater current carrying capacityof the conductor while maintaininghigh mechanical strength andelectrical integrity. Range taking design––minimum number ofconnector combinations required to installa conductor range of #6 solid to 500 kcmilplus 1/2 , 5/8 , 3/4 , and 1 ground rodsand rebar.〫 Inventories are kept to a minimum andproduct selection is simplified. System engineered tooling.〫 Each tooling recommendation hasbeen designed to ensure reliabilityof the connection. Irreversible compression connectorscan be installed in all kinds of weather.〫 Eliminates costly construction delaysand enables the installer to betterschedule his job. May be installed without special trainingor special tools. Y750 crimps entire range.〫 Low installed cost.〫 Simplified installation. Each connection can be made in less than3 minutes.〫 Low installed cost.〫 Simplified installation. Each connector is clearly marked withcatalog number, conductor size andinstallation die information.〫 Easy and accurate identification. Inspection ports are provided to assureproper insertion of the conductor.〫 Built-in quality assurance. The die index number is embossed on theconnector after completion of the crimp.〫 Facilitates speedy inspection ofinstalled connectors to insure consistently reliable and sound connections. Most HYGROUND irreversible compression elements are prefilled withPENETROX and individually sealedin clear polyethylene sheet.〫 Ensures that all contact surfaces are inthe proper condition for installation.〫 Ensures the electrical integrity of thefinished connection by inhibiting moisture and contaminates from entering thecontact area. All HYGROUND irreversible compressionconnectors are Listed in conformance withUnderwriters Laboratories StandardUL467 and conform to applicable sectionsof the National Electrical Code.〫 May be used in direct burial or concreteembedded grounding applications. All HYGROUND irreversible connectors(with the exception of type YGA and YGS)have been tested successfully accordingto requirements of Standard IEEE 837.〫 Meets tough industry performancerequirements.〫 UPRECRIMP dies give addedmechanical strength. UPRECRIMP 34for 3/4 rod, UPRECRIMP 12 for 1/2 rod, and UPRECRIMP 58 for 5/8 rod(now includes undersized U.S. marketplace rods). Allows connection to most sizes ofstructural steel with no drilling, tapping,or welding.〫 Safely installed at low cost. Hot workpermits are not required to install inhazardous areasThroughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY Products.Canada: 1-800-387-6487www.burndy.comUS: 1-800-346-4175

BURNDY ProductsGroundingHYGROUND CompressionTYPE YGL-CHYGRID CROSS CONNECTORAn irreversable compression ground gridcross connector which allows adjustment ofthe compression elements prior to installation. Only six connectors and four dies arerequired to install all combinations from #6solid through 500 kcmil. UL467 Listed.Acceptable for direct burial in earth and concrete. Prefilled with PENETROX compoundand strip 3.500.750LR.31.50.31.50.752.50UL96 Listed for Lightning Protection.ORDERING C2YGL34C29YGL34C34Cable to CableElement “A”Element “B”#6 Sol. (.162) – #2 Str. (.292){59500} – {59500}#6 Sol. (.162) – #2 Str. (.292)#1 Str. (.332) – 250 kcmil (.575){59500} – {59500}{98500} – {131500}#2 Str. (.292) – 250 kcmil (.575)#2 Str. (.292) – 250 kcmil (.575){65500} – {131500}{65500} – {131500}#6 Sol. (.162) – #2 Str. (.292)250 kcmil (.575) – 500 kcmil (.813)#2 Str. (.292) – 250 kcmil (.575)250 kcmil (.575) – 500 kcmil (.813)Cable to Ground RodElement “A”Element “B”To RebarElement “A”#6 Sol. (.162) – #2 Str. (.292)3/8 – 1/2 #2 Str. (.292) – 250 kcmil (.575)#3 – 4 Rebar#6 Sol. (.162) – #2 Str. (.292)#2 Str. (.292) – 250 kcmil (.575)250 kcmil (.575) – 500 kcmil (.813)5/8 – 3/4 #5 – 6 Rebar1/2 – 5/8 Rod5/8 – 3/4 RodDimensions in brackets { } represent lightningprotection conductors.CatalogNumberY750/Y35/Y39 HYPRESS Element “A” Element “B”Installation Tools, Die Set Catalog Number (Number of Crimps)PAT750-18VY45 HYPRESS Element “A”Element “B”Element “A”Element “B”YGL2C2YGL29C2YGL29C29U-0 (1)U997 (1)U997 (1)U-0 (1)U-0 (1)U997 (1)U-0 (1)➂ U997P (1)➂ U997P (1)U-0 (1)U-0 (1)➂ U997P (1)YGL34C2*PU998 (1)U-0 (1)PU998 (1)U-0 (1)YGL34C29*PU998 (1)U997 (1)PU998 (1)➂ U997P (1)YGL34C34*U1011 (3)U1011 (3)U1011 (3)U1011 (3)1. Where a “U” or “PU” die is recommended with Y45HYPRESS , a PT6515 adapter must be used.2. Where a “U” or “PU” die is recommended with the Y46HYPRESS , a PUADP-1 adapter must be used.➂ Polarized die for the PAT750-18V.NOTES: Before crimping, both connector elements canbe turned on rod diameter “D” to any desiredposition. Clean rust and/or protective coatings from rebarprior to installation.U-0 (1)U997 (1)U997 (1)S998 orPU998 (1)S998 orPU998 (1)S1011 (3)U-0 (1)U-0 (1)U997 (1)U-0 (1)U997 (1)S1011 (3)Y46 HYPRESS Element “A”Element “B”U-0 (1)U997 (1)U997 (1)P998 orPU998 (1)PU998 orPU998 (1)P1011 (3)U-0 (1)U-0 (1)U997 (1)U-0 (1)U997 (1)P1011 (3)* These connectors can only be installed using the Y750,Y45, or Y46 HYPRESS with the recommended dies.These connectors CANNOT be installed with the Y35 andY39 HYPRESS . When attaching connector to ground rod,ground rod must be embossed with appropriatePRECRIMP die. For connections that mustmeet IEEE 837 requirements UPRECRIMP type PRE crimp dies must be used for maximumclamping retention.Ground RodDia.1/2 5/8 3/4 PRECRIMP DiesUPRECRIMP 12UPRECRIMP 58UPRECRIMP 34U2CABTThroughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY Products.US: 1-800-346-4175www.burndy.comCanada: 1-800-387-6487

BURNDY ProductsGroundingHYGROUND CompressionTYPE YGLR-CGRIDLOKE-8Element AHigh StrengthIrreversibleCompression Ground Rod toGrid ConnectorElement BGround grid connector for a wide range ofcopper cable to ground rod. Provides hightorque strength on ground rod. UL467Listed. Acceptable for direct burial in earthand concrete. Prefilled with PENETROX compound and strip CIALCOPPERCABLE RANGEELEMENT “A”METRIC COPPERCABLE RANGEELEMENT “A”#2 Str. (.292 Dia.)35mm2 (7.62mm Dia.)thruthru250 kcmil (.575 Dia.) 120 mm2 (14.40mm Dia.)250 kcmil (.575 Dia.) 120 mm2 (14.40mm Dia.)thruthru500 kcmil (.813 Dia.) 240 mm2 (20.35mm Dia.)#2 Str. (.292 Dia.)35 mm2 (7.62mm Dia.)thruthru250 kcmil (.575 Dia.) 120 mm2 (14.40mm Dia.)250 kcmil (.575 Dia.) 120 mm2 (14.40mm Dia.)thruthru500 kcmil (.813 Dia.) 240 mm2 (20.35mm Dia.)#2 Str. (.292 Dia.)35 mm2 (7.62mm Dia.)thruthru250 kcmil (.575 Dia.) 120 mm2 (14.40mm Dia.)250 kcmil (.575 Dia.) 120 mm2 (14.40mm Dia.)thruthru500 kcmil (.813 Dia.) 240 mm2 (20.35mm Dia.)#2 Str. (.292 Dia.)35 mm2 (7.62mm Dia.)thruthru250 kcmil (.575 Dia.) 120 mm2 (14.40mm Dia.)250 kcmil (.575 Dia.) 120 mm2 (14.40mm Dia.)thruthru500 kcmil (.813 Dia.) 240 mm2 (20.35mm Dia.)COPPER WELDCABLE RANGEELEMENT “A”91.65 kcmil (.343 Dia.)thru248.8 kcmil (.572 Dia.)248.8 kcmil (.572 Dia.)thru498.8 kcmil (.810 Dia.)91.65 kcmil (.343 Dia.)thru248.8 kcmil (.572 Dia.)248.8 kcmil (.572 Dia.)thru498.8 kcmil (.810 Dia.)91.65 kcmil (.343 Dia.)thru248.8 kcmil (.572 Dia.)248.8 kcmil (.572 Dia.)thru496.8 kcmil (.810 Dia.)91.65 kcmil (.343 Dia.)thru248.8 kcmil (.572 Dia.)248.8 kcmil (.572 Dia.)thru498.8 kcmil (.810 Dia.)IEEE-837GROUND RODDIA.ELEMENT “B”BB-BDLINSTALLATION TOOLS, DIE SET CAT. NO., (NUMBER OF CRIMPS)Y35/Y39 HYPRESS Y750/PAT750Y45 HYPRESS Y46 HYPRESS ELEMENT ELEMENT ELEMENT ELEMENT ELEMENT ELEMENT ELEMENT ��A”“B”U997 (1)PU998 (1)1/2 [12.7]—.313[7.9]2.53[64.3]U997 (1)PU998 (1)5/8 [15.9].75.88[19.1] [22.4]PU998 (1)3/4 [19.1]1 [25.4]U997 (1)U997 (1)U1011orPU998 (1)S998orPU998 (1)P998orPU998 (1)U997 (1)U997 (1)U997 (1)U1011orPU998 (1)—U997 (1)U997 (1).500 2.63[12.7] [66.8]——1 [25.4]U1011 (2)orPU998 (1)S998orPU998 (1)S1012 (2)orPU998 (1)P998orPU998 (1)U997 (1)U997 (1)U997 (1)U1011 (2)orPU998U1011 (2)orPU998U1011 (2)orPU998U997 (1)U997 (1)U997 (1)U1011 (2)orPU998 (1)U1011 (2)orPU998U1011 (2)orPU998P1011(2)orPU998 (1)NOTES:1. Before crimping, both connector elements canbe turned on rod diameter 'D' to any desiredposition.2. Grooves are filled with PENETROX .3. Suitable for direct burial in earth or concrete.4. The catalog numbers shown are for unplatedcopper connectors for use on copper clad orstainless steel ground rod. To order electro-tinplated connectors for use on galvanized steelground rod add suffix “TN” to the catalog number, only if the Figure 8 connector (Element “B”)is tin plated, the Figure 6 connector (Element “A”)is unplated. Note: The ground rod hole diameteris larger for galvanized steel ground rod in the tinplated connector.5. Ground rod must be pre-crimped with dieU2CABT (Index No. 348) when crimping theground rod element (Element “B”) with the PU998dies in the Y750, Y35, Y39, Y45, or Y46 tools.Pre-crimping is not required when the S1012,P1011 or U1011 dies are used. See precrimp diechart.6. Where a 'U' or 'PU' die is recommended with theY45 HYPRESS , a PT6515 adapter must beused.7. Where a 'U' or 'PU' die is recommended with theY46 HYPRESS , a PUADP-1 adapter must beused.GROUND RODDIA.1/2 5/8 3/4 PRECRIMP DIESUPRECRIMP 12UPRECRIMP 58UPRECRIMP 34U2CABTWhen attaching connector to ground rod, groundrod must be embossed with appropriate PRECRIMP die. For connections that must meet IEEE837 requirements UPRECRIMP - type PRE crimpdies must be used for maximum clamping retention.8. Dimensions in bracket [ ] are in millimeters.9. Die “1011” appears on Element “B” of theconnector only.Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY Products.Canada: 1-800-387-6487www.burndy.comUS: 1-800-346-4175

BURNDY ProductsGroundingHYGROUND CompressionTYPE YGHP-CHYTAP CONNECTORIrreversible compression ground tap figure 6can be used as a tap connector or as a tapsplice connector. Four die sets and eight connectors can accommodate a conductorrange from #8 solid through 500 kcmil plus1/2 , 5/8 , and 3/4 copper bonded groundrods. UL467 Listed. Acceptable for directburial in earth and concrete. Prefilled withPENETROX compound and strip sealed.E-9UL96 Listed for Lightning Protection.IEEE-837467Fig. HP29C6W6W➇2YGHP29C21YGHP29C261YGHP29C29 ➁1YGHP34C2 ➅1YGHP34C26 ➅1YGHP34C29 ➅YGHP34C34 ➅11ACCOMMODATESRUNTAP#6 Sol. (0.162) {59500} –➀ #6 Sol. (0.162) {#2 Str.} –#2 Str. (0.292) {59500}#2 Str. (0.292) {#2 Str.}#6 Sol. (0.162) –#8 Sol. (0.128) –#2 Str. (0.292)6 Str. (0.184) Qty. 2#8 Sol. (0.128) –6 Str. (0.184) Qtr. 2#4 Sol. (0.204) {#4 Sol.} –1/0 Str. (0.372) {98500} –#2 Str. (0.292) {#2 Str.}250 kcmil (0.575) {131500}1/0 Str. (0.372) {98500} –1/2 – 5/8 Rod2/0 Str. (0.419) {98500}3/0 Str. (0.470) {131500} –250 kcmil (0.575) {211500}#4 Sol. (0.204) –#2 Str. (0.292)250 kcmil (0.575) {250 kcmil} –1/0 Str. (0.372) {98500} –500 kcmil (0.813) {500 kcmil}2/0 Str. (0.419) {98500}5/8 – 3/4 Rod3/0 Str. (0.470) {131500} –250 kcmil (0.575) {211500}250 kcmil (0.575) –350 kcmil (0.681) –500 kcmil (0.813)500 kcmil (0.843)5/8 – 3/4 RodCABLE TO REBARRUNTAP————#3 Rebar3/8#5 Rebar5/8INSTALLATION DATADIE Y750/Y35➂➃INDEXY39Y45Y46B NO. HYPRESS PAT750-18V HYPRESS HYPRESS 0U0U0U0U01997U997➆ U997PU997U9971998PU998PU998PU998 orS998PU998 orP9981➅U1011U1011S1011P10113#2 Str.1/0 Str. – 2/0 Str.75[19]3/0 Str. – 250 kcmil—1/0 Str. – 2/0 Str.through3/0 Str. – 250 kcmil3/4#6 Rebar 350 kcmil – 500 kcmil1.101011[28]Dimensions in brackets { } represent lightning protectionconductors.GROUND RODDIA.NOTES:➀ When using #6 Sol. in tap, fold conductor double toimprove fill in YGHP2C2.➁ For YGHP29C29 when using 3/0 in tap, minimum runconductor is 2/0 STR.➂ Where a 'U' or 'PU' die is recommended with the Y45HYPRESS , a PT6515 adapter must be used.➃ Where a 'U' or 'PU' die is recommended with the Y45HYPRESS , a P-UADP-1 adapter must be used.NO. OFCRIMPS#8 Sol. – 6 Str.t

for grid cross connections, taps, splices, cable to ground rod, ground plates and ter-minations. Our irreversible compression ground con-nectors employ well-proven design princi-ples and technology that have been in exis-tence for over 60 years. Connectors are just one

Related Documents:

Grounding Study and Analysis: Substation Grounding Practices Grounding Concepts - GPR and Touch Potential AEP Innovative Grounding Study Methods Grounding Installation: Traditional Approach and Challenges Grounding Application and Installation Change Management Testing: Grounding Integrity Testing Conclusion and .

Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 4 12-TON U DIES* BURNDY Die Sets Fits Y35, Y39, Y750 Series, PAT750-18V Series, PAT46-18V, Y46 (W/PUADP-1 Adapter) Wire Size Copper Aluminum U die case Part# PT29291, holds up to 15 dies Small #8 U8CRT U8CABT #6 U5CRT U6CABT #4 U4CR

NEC Table 250.122 - Minimum size equipment grounding conductors for grounding raceway and equipment Table 2 – Minimum size equipment grounding conductors for grounding raceway and equipment Aluminum Cable Tray Systems Table 392.60(A) – Metal area requiremen

BURNDY Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Grounding Compression, Mechanical, Exothermic E-3 TABLE OF CONTENTS (continued) E-71 E-72 E-73 E-74 E-75 E-76 E-77 E-78 E-79 E-79 E-80 E-81 QI

(HYGROUND Tool/Die Chart continued on next page) * Indicates that connector can only be installed with Y750 or Y46. Cannot be installed with Y35 or Y39. ** Where a U-die is recommended with the Y46, a PUADP-1 adaptor must be used. Catalog Die No. of Number Index Y750/39/35

Grounding Electrode System and Grounding Electrode Conductor Part III zNEC 250.50 (Grounding Electrode System) 250.52 Electrodes Water Pipe if 10 ft. or more of metal water pipe is in contact with the earth. Metal Frame of the Building or Structure where the followin

Article 250.1 Scope. Article 250 is organized into 10 different parts that deal with specific requirements with regards to bonding and grounding. The specific parts are as follows: (I) General (II) System Grounding (III) Grounding Electrode System and Grounding electrode Conductor (IV) En

grounding bar in the service equipment. The grounding electrode conductor shall extend to a grounding electrode (a ground rod or other effective electrode). 6.2.3 An equipment grounding conductor shall originate at this service equipment and shall be installed with the circuit conductors to the waterer. 6.2.4 The equipment grounding conductor .