EcoSystemCableLow-Voltage Cables369385c 1 01.22.2018EcoSystem CableCustom designed cable, for use with EcoSystemcomponents, improves system performance anddecreases installation time. Cable is available for sensorconnections and EcoSystem bus connections. Bothtypes are available in plenum versions.Features Internal conductors match EcoSystem device terminaland lead color scheme.EcoSystem Bus CableC-CBL-216-GR-1 (non-plenum, Class 2)C-CBL-216-WH-C1 (non-plenum, Class 1)C-PCBL-216-CL-1 (plenum, Class 2) Each conductor sized for direct connection toEcoSystem ballast and module terminals. Three types of EcoSystem bus cable:- Non-plenum bus cable (CL3R), for Class 2 applications- Non-plenum bus cable (TC), for Class 1 applications-P lenum bus cable (CL3P) for plenum Class 2 applications Two types of EcoSystem Class 2 sensor cable:EcoSystem Class 2 Sensor CableC-CBL-522S-WH-1 (non plenum)C-PCBL-522S-CL-1 (plenum)- Non-plenum sensor cable (CL3)- Plenum sensor cable (CL3P) All plenum cable is rated to a maximum of 300 V. Non-plenum cable is rated to a maximum of 300 V or600 V dependant upon application. Each offering is spooled to 1000 ft (305 m) and basedupon industry standards of 10% on all shipments.Lutron, )Lutron, and EcoSystem are trademarks of Lutron Electronics Co., Inc., registered in the U.S. and other countries. Job Name:Job Number:S P E C I F I C AT I O N S U B M I T TA LModel Numbers:Page 1

EcoSystemCableLow-Voltage Cables369385c 2 01.22.2018EcoSystem Bus Cable SpecificationsC-PCBL-216-CL-1General DescriptionTwo conductor EcoSystem bus cable for plenum spaces16 AWG (1.5 mm2) solid bare copper, FEP insulated conductors2 single conductors cabledClear 0.017 in (0.43 mm) thick FEP jacket — sheathedAll external markings use white inkElectricalMaximum operating voltageMaximum continuous current per conductorNominal conductor DC resistance300 V RMS10 A4 Ω/1000 ft (304.8 m)PhysicalTemperature RatingNominal DiameterMaximum Pull TensionMinimum Bend RadiusInsulation MaterialJacket Material-94 F to 392 F (-70 C to 200 C)0.173 in (4.39 mm)45 lb (20.41 kg)1.75 in (44.5 mm)FEPFEPCL3Pat 77 F (25 C)at 68 F (20 C)ListingsUL listed as Type CL3P or CMP c(UL)us, FT-6NFPA 262UL444 and UL13CSA-C22.2 No. 214RoHS CompliantColorsJacket — Clear (CL)Conductor ColorPurple (PL)Purple white stripe (PL/WH)Ballast TerminalE1E2Jacket MarkingsLUTRON C-PCBL-216-CL-1 2/16 AWG (UL File #) (UL) CL3P orCMP c(UL)us 200 C FT-6 RoHS COMPLIANT Job Name:Job Number:S P E C I F I C AT I O N S U B M I T TA LModel Numbers:Page 2

EcoSystemCableLow-Voltage Cables369385c 3 01.22.2018EcoSystem Bus Cable Specifications (continued)C-CBL-216-GR-1General DescriptionFor running EcoSystem link with other Class 2 wires in non-plenum applications16 AWG (1.5 mm2) solid bare copper, PVC insulated conductors2 single conductors cabledGray 0.03 in (0.76 mm) thick PVC jacket — sheathed, UV stabilizedAll external markings use black inkElectricalMaximum operating voltageMaximum continuous current per conductorNominal conductor DC resistancePhysicalTemperature RatingNominal DiameterMaximum Pull TensionMinimum Bend RadiusInsulation MaterialJacket Material300 V RMS600 V RMS13 A4 Ω/1000 ft (304.8 m)CL3R/CMGAWM Style 20811at 77 F (25 C)at 68 F (20 C)-4 F to 221 F (-20 C to 105 C)0.300 in (7.62 mm)62.5 lb (28.35 kg)1.75 in (44.5 mm)PVCPVCListingsUL Type CL3RCMG (C)ULFT-4 Flame RatingAWM Style 20811UL 1666 Vertical ShaftRoHS CompliantColorsJacket — Gray (GR)Conductor ColorPurple (PL)Purple white stripe (PL/WH)Ballast TerminalE1E2Jacket MarkingsC-CBL-216-GR-1 LUTRON 2/16 AWG CL3R 90 C (UL) E171202or CMG c(UL)or AWM STYLE 20811 105 C 600 V DATE CODE FT-4 RoHS COMPLIANT Job Name:Job Number:S P E C I F I C AT I O N S U B M I T TA LModel Numbers:Page 3

EcoSystemCableLow-Voltage Cables369385c 4 01.22.2018EcoSystem Bus Cable Specifications (continued)C-CBL-216-WH-C1General DescriptionFor running EcoSystem link with other line-voltage wires (Class 1) in non-plenum applications16 AWG (1.5 mm2) solid bare copper, PVC/Nylon insulated conductors2 single conductors cabledWhite 0.045 in (1.1 mm) thick PVC jacket — sheathed, UV stabilizedAll external markings use black inkElectricalMaximum operating voltageMaximum continuous current per conductorNominal conductor DC resistancePhysicalTemperature RatingNominal DiameterMaximum Pull TensionMinimum Bend RadiusInsulation MaterialJacket Material600 V RMS600 V RMS20 A4 Ω/1000 ft (304.8 m)TCUL STANDARD 62, TYPE TFNat 77 F (25 C)at 68 F (20 C)-4 F to 194 F (-20 C to 90 C)0.299 in (7.59 mm)41 lb (18.6 kg)1.75 in (44.5 mm)PVC and NylonPVCListingsUL Type TC Per UL Standard 1277 for tray cablesCSA Listed CIC C22.2 No. 239-09UL Approved for Sunlight ResistanceIndividual Conductors are rated TFNCable meets IEEE 383 & UL 1581 70,000 BTU/h Flame Test RequirementsCable meets ICEA S-95-658, where applicableFT-4 Flame RatingRoHS CompliantColorsJacket — White (WH)Conductor ColorPurple (PL)Purple white stripe (PL/WH)Ballast TerminalE1E2Jacket MarkingsC-CBL-216-WH-C1 LUTRON (UL File #) 2/16 AWG 2C TFN (UL) TYPE C 600 V 90 C DRY PVC JACKET SUN RESor CSA LL226471 CIC (TC) FT-4 RoHS COMPLIANT Job Name:Job Number:S P E C I F I C AT I O N S U B M I T TA LModel Numbers:Page 4

EcoSystemCableLow-Voltage Cables369385c 5 01.22.2018EcoSystem Class 2 Sensor Cable SpecificationsC-PCBL-522S-CL-1General Description5 conductor EcoSystem sensor cable for plenum spaces22 AWG (0.34 mm2) solid bare copper, FEP insulated conductorsOverall aluminum-polymer foil shield, plus 24 AWG (0.25 mm2) copper drain wireClear 0.012 in (0.3 mm) thick FEP jacket — sheathedAll external markings use white inkElectricalMaximum operating voltageMaximum continuous current per conductorNominal conductor DC resistance300V RMS4 A16.5 Ω/1000 ft (304.8 m)PhysicalTemperature RatingNominal DiameterMaximum Pull TensionMinimum Bend RadiusInsulation MaterialJacket Material-94 F to 392 F (-70 C to 200 C)0.140 in (3.56 mm)36.0 lb (16.33 kg)1.50 in (38.1 mm)FEPFEPCL3Pat 77 F (25 C)at 68 F (20 C)ListingsUL listed as Type CL3P or CMP c(UL)us, FT-6NFPA 262UL444 and UL13CSA-C22.2 No. 214RoHS CompliantColorsJacket — Clear (CL)Conductor ColorRedBlackWhiteBlueYellowBallast Terminal 20 VCommonIROccupancyDaylightJacket MarkingsLUTRON C-PCBL-522S-CL-1 (UL File #) 22 AWG 5C SHIELDED (UL) CL3P orCMP c(UL)us FT-6 200 C RoHS COMPLIANT Job Name:Job Number:S P E C I F I C AT I O N S U B M I T TA LModel Numbers:Page 5

EcoSystemCableLow-Voltage Cables369385c 6 01.22.2018EcoSystem Class 2 Sensor Cable Specifications (continued)C-CBL-522S-WH-1General Description5 conductor EcoSystem sensor cable for non-plenum applications22 AWG (0.34 mm2) solid bare copper, PVC insulated conductorsOverall aluminum-polymer foil shield, plus 24 AWG (0.25 mm2) copper drain wireWhite 0.047 in (1.2 mm) thick PVC jacket — sheathed, UV StabilizedAll external markings use indented printElectricalMaximum operating voltageMaximum continuous current per conductorNominal conductor DC resistancePhysicalTemperature RatingNominal DiameterMaximum Pull TensionMinimum Bend RadiusInsulation MaterialJacket Material300 V RMS600 V RMS4A16.5 Ω/1000 ft (304.8 m)CL3AWM 20811at 77 F (25 C)at 68 F (20 C)-4 F to 221 F (-20 C to 105 C)0.297 in (7.54 mm)36.0 lb (16.33 kg)3 in (76.2 mm)PVCPVCListingsUL Type CL3 and CMUL recognized AWM Style 20811UL444, UL13 and UL758CSA-C22.2 No. 214CPR Classification: ECAROHS CompliantColorsJacket - White (WH)Conductor ColorRedBlackWhiteBlueYellowBallast Terminal 20 V CommonIROccupancyDaylightJacket MarkingsLUTRON C-CBL-522S-WH-1 PELV/SELV (UL File #) 22 AWG 5C SHIELDED (UL) CL3 orAWM 20811 105 C 600V RoHS COMPLIANTCM c(UL)us 75 C OR Job Name:Job Number:S P E C I F I C AT I O N S U B M I T TA LModel Numbers:Page 6

EcoSystem Cable Lo-oltage Cables 369385c 1 01.22.2018 EcoSystem Cable Custom designed cable, for use with EcoSystem components, improves system performance and decreases installation time. Cable is available for sensor connections and EcoSystem bus conn

Related Documents:

Catalogue 2020-21 Life Line Plus S3 (HRFR) Cable Life Guard (FR-LSH) Cable Life Shield (HFFR) Cable Multicore Round Cable Shielded Cables Flat Submersible Cable Telephone Switch Board Cable LAN Cable CCTV Cable Co-Axial TV Cable Speaker Cable Presenting Domestic Cable Range for Safer, Securer Homes.

instrumentation tray cable 10 general purpose cable 12 instrumentation tray exposed run direct burial cable 14 power tray exposed run direct burial cable 16 industrial ethernet cable 18 fieldbus technology cable 20 extremelife cable 22 flexlife cable 24 weldlife cable 26 armorfast instrumentation cable 28 flexible service cable

EcoSystem Bus and supports system programming All EcoSystem Bus programming is completed by using the EcoSystem Programmer, GRAFIK Eye QS Control Unit with EcoSystem Lighting Control System, or QuantumTM Software EcoSystem Bus Wiring EcoSystem Ballast Bus terminals only acc

Sep 24, 2019 · Carol Middleton, Education Program Spec 2. Not Available. Sherrie Moine, Executive Support Spec (503) 947-5649 . Lillian White, Education Spec (503) 934-0742. Art Witkowski, Education Program Spec . Ed. Spec, Physical/Health Education (503) 947-5960. Amit Kobrowski, Ed. Spec, Social Sciences (

RJ45 Port: Data cable, Ethernet cable, Cat5e, Cat6, Cat6a, Cat7, Cat7a. F-Connector Port: Video cable, coaxial cable, RG6/RG6Q cable, RG59 cable. RJ11/12 Port: Voice cable, POTS (plain old televoice service) cable, 4-wire cable, 6-wire cable, 2 twisted-pair cables, 3 twisted-pair cables, Cat3. VDV SCOUTTM PRO 3 TESTER LOCATION ID REMOTES

Coaxial cable quick reference guide Author: CommScope Subject: Quick reference guide for coaxial cables for hardline trunk, distribution and drop cable applications. Keywords: coaxial cable, hfc network, hybrid fiber coaxial, P3 cable, QR cable, XPRESSPREP cable, BrightWire, hardline cable, trunk cable, drop cable, CATV, CO-112310.1-EN Created Date

DVI and D-sub cable, the DVI cable must be connected along side the rib on the power cord side (Figure 4). 5. For successful cable management, place the cables in this order into the cable management: audio cable (NXM only), power cable, and DVI cable (Figure 5). 6. Place DVI cable, audio cable (NXM only), and power cable into the specific hooks

sebuah standar akuntansi untuk lembaga keuangan syariah yang disebut accounting, auditing, and governance standard for Islamic institution. 3. Perkembangan Akuntansi di Indonesia (IAI) Ketika Indonesia merdeka, hanya ada satu orang akuntan pribumi, yaitu Prof. Dr. Abutari, sedangkan Prof. Soemardjo lulus pendidikan akuntan di