N109212CA OIF-CEI-112G

2y ago
68 Views
5 Downloads
1.60 MB
19 Pages
Last View : 5d ago
Last Download : 3m ago
Upload by : Julius Prosser
Transcription

N109212CA OIF-CEI-112GMeasurement and Debug ApplicationCharacterize CEI-112G-VSR/MR/LR Electrical TX Designs using N1000A DCA-X Wide-BandwidthOscilloscopesFind us at www.keysight.comPage 1

Table of ContentsIntroduction . 3Transform Complexity into Simplicity . 4Select Industry-leading Hardware . 5Select the Desired Software Test Suite . 5OIF-CEI-112G-VSR (oif2017.346.14 PAM4). 6OIF-CEI-112G-VSR (oif2017.346.13 PAM4). 6OIF-CEI-112G-MR (oif2019.340.03 PAM4) . 6OIF-CEI-112G-LR (oif2018.212.10 PAM4) . 6Configure Your Measurements . 7Choose Your Tests . 7Automated Return Loss Measurements. 8Automated Tuning for Optimal Eye Opening. 9Guided Connection Diagrams for Easy Setup. 10More Features Streamline Development. 11Generate reports . 11Control Your Device or Other Equipment . 12Configure Your Solution in Three Ways . 13Guided Connection Diagrams for Easy Setup. 14Solution 1: Keysight N1000A DCA-X Mainframe N1060A “MegaModule” (Recommended) . 15Solution 2: Keysight N1000A DCA-X Mainframe with DCA Module External Clock Recovery. 16Equipment configuration for solution 2: Keysight N1000A DCA-X Mainframe with DCA Module External Clock Recovery . 17Ordering Information . 18License Types: . 18License terms:. 19KeysightCare Software Support Subscription: . 19Required Software Options . 19Find us at www.keysight.comPage 2

IntroductionSeveral industry and standards bodies have defined specifications for 100 Gb/s highspeed electrical interface using PAM4 coding. As an example, an implementationagreement (IA) developed by the Optical Internetworking Forum – Common ElectricalInterface (OIF-CEI) defines 112 Gb/s operation in OIF-CEI 112G using 53/56 PAM4signalling (CEI-112G-VSR/MR/LR).The Keysight N109212CA OIF-CEI-112G software is a measurement application forthe DCA-X equivalent-time sampling oscilloscopes designed to save time and moneyby automating the task of performing PAM4 transmitter (TX) test measurements.Find us at www.keysight.comKeysightN109212CA OIFCEI-112G softwareThe KeysightN109212CA OIF-CEI112G software is ameasurementapplication for theDCA-X equivalent-timesampling oscilloscopesdesigned to save youtime and money byautomating the task ofperforming Pam4transmitter (TX) testmeasurementsPage 3

Transform Complexity into SimplicityThe N109212CA is an easy-to-use TX test application that: Saves time in understanding details of standards Reduces the time it takes to characterize your PAM4 design from hours to minutes Helps debug your device using custom configurations Automates optimization of CTLE DFE equalizer settings Allows you to quickly generate HTML reports that summarize the performance of your deviceFigure 1. 53 Gbaud PAM4 eye diagram with PRBS13Q pattern lengthFind us at www.keysight.comPage 4

Select Industry-leading HardwareConfigure your oscilloscope for single or multi-channel capability. The N109212CA application supportsa variety of digital communication analyzer (DCA) oscilloscope configurations, including the N1000ADCA-X wide-bandwidth oscilloscope platform, N1060A precision waveform analyzer or the N104X 2/4port remote heads and DCA-M family clock data recovery module. For return loss, the software controlsan N1055A TDR module (or a performance network analyzer) and performs S-parametermeasurements. For more hardware configuration details, refer to the Ordering Guide in the document.Figure 2. N1000A DCA-X Wide-Bandwidth Oscilloscope Mainframe and N1060A Precision Waveform AnalyzerSelect the Desired Software Test SuiteThe N109212CA OIF-CEI-112G TX test application covers PAM4 transmitter measurements outlined inclauses 112G-VSR/MR/LR of OIF-CEI-112G (PAM4). The tests are sorted conveniently by clause. Clickon the desired test group, and the appropriate tests are offered in the Select Tests tab (factory-installedoptions shown)Figure 3. Standard Option that available in N109212CA OIF-CEI-112G TX test applicationFind us at www.keysight.comPage 5

The N109212CA test application covers most TX tests outlined in the tables below. For acomprehensive and up-to-date list of specific tests covered by the application, download theN109212CA application from www.keysight.com, install it on a PC, and run the application in “DemoMode”. No license (or hardware) is required to run the software application in “Demo Mode”.OIF-CEI-112G-VSR (oif2017.346.14 PAM4)OIF-CEI ReferenceDescriptionSection 23.3.2Host-to-Module at TP1a, Table 23-1Section 23.3.3Module-to-Host at TP4, Table 23-4OIF-CEI-112G-VSR (oif2017.346.13 PAM4)OIF-CEI ReferenceDescriptionAppendix 23.C.2Host-to-Module at TP0a, Table 23-13OIF-CEI-112G-MR (oif2019.340.03 PAM4)OIF-CEI ReferenceDescriptionSection 25.3.1Table 25-3 and 25-4 (MR-PAM4)OIF-CEI-112G-LR (oif2018.212.10 PAM4)OIF-CEI ReferenceDescriptionSection 28.3.1Table 28-3 and 28-4 (LR-PAM4)Find us at www.keysight.comPage 6

Configure Your MeasurementsFigure 4. Configuration tab of N109212CA OIF-CEI-112G TX test applicationCustomize parameters that are specific to your setup, such as signaling rate and CTLE setting. Usedefault values or enter your own settings including SIRC filter response & bandwidth, type of pattern,and pattern symbol length, Choose Compliance mode to test within limits or choose Debug mode to testto your custom limits and adjust other test parameters.Choose Your TestsThe N109212CA OIF-CEI-112G TX test application provides comprehensive coverage of most PAM4tests that are specific to the clause you are testing. You may click on all available tests, a group of tests,or select individual tests to run. The full test name appears in the test list and is also shown in the testand reports. A description of the test and reference to the Standard is shown for each test.Figure 5. Available tests of N109212CA OIF-CEI-112G TX test applicationFind us at www.keysight.comPage 7

Figure 6. A group of tests were selected in N109212CA OIF-CEI-112G TX test applicationAutomated Return Loss MeasurementsWhen used in conjunction with an N1055A TDR module or vector network analyzer (PNA), theN109212CA OIF-CEI-112G TX test application performs common mode to differential and common modereturn loss measurements.Figure 7. Return loss measurement selection of N109212CA OIF-CEI-112G TX test applicationFind us at www.keysight.comPage 8

Automated Tuning for Optimal Eye OpeningThe N109212CA OIF-CEI-112G TX test application provides utility test, to perform auto-tuning on theCTLE & DFE and find the optimal eye opening for eye mask measurement at TP1a & TP4 (Near-end &Far-end). Use default values or change to your own settings on the CTLE gDC & gDC2 settings in theconfigure tab.Figure 8. Automated tuning feature of CTLE and DFE for eye openingFigure 9. Settings for automated tuning in N109212CA OIF-CEI 112G TX test applicationFind us at www.keysight.comPage 9

Guided Connection Diagrams for Easy SetupSimply follow the steps to connect and configure your device under test and click Run Tests. TheN109212CA OIF-CEI-112G TX test application automatically configures and controls your supportedDCA-X oscilloscope.Figure 10. Connection diagram of N109212CA OIF-CEI-112G TX test applicationFind us at www.keysight.comPage 10

More Features Streamline DevelopmentGenerate reportsYour team members and your customers are interested in the performance of your device. Share a testresults report with them that shows the test conditions, summary of pass/fail, summary of all tests, anddetails for each test. Many include a test-specific screen shot of the measured parameter.Figure 11. Test report and detailsFind us at www.keysight.comPage 11

Control Your Device or Other EquipmentThe Automation tab enables you to enter commands to control external devices or equipment, and tofurther sequence your tests or to control timing.Figure 12. Automation commands in N109212CA OIF-CEI-112G TX test applicationFind us at www.keysight.comPage 12

Configure Your Solution in Three WaysThe hardware and software architecture provides wide flexibility. The N109212CA TX test applicationmay be run as follows:1. N1000A DCA-X runs the N109212CA application locally and controls remote PNA via LAN2. PC runs the N109212CA application and controls remote N1000A DCA-X, PNA via LAN3. PC runs both N109212CA and N1010A FlexDCA software applications and controls remoteN1000A DCA-X and PNA via LANThis lets you use your PC for additional processing power and other applications, or you can have all the measurement capabilityconsolidated into a compact solution. For return loss measurements, the N109212CA application can control an N1055A TDR orPNA vector network analyzer to perform measurements automatically.Figure 13. PC runs both DCA time-equivalent oscilloscope and PNA via LANFind us at www.keysight.comPage 13

Guided Connection Diagrams for Easy SetupKeysight offers a wide range of electrical and optical test solutions to address current and emergingcommunications standards. For OIF-CEI-112G testing, you may choose a hardware combination thataddresses your test needs for today, and into the future:1. N1000A DCA-X with N1060A (Integrated “One-Box” solution) - recommended2. N1000A DCA-X with DCA module and external clock recoveryFind us at www.keysight.comPage 14

Solution 1: Keysight N1000A DCA-X Mainframe N1060A “MegaModule” (Recommended) Highest accuracy Easy setup Integrated solutionMainframe Model No.Return LossMeasurementsTX test using digital communications analyzer (DCA)N1000A DCA-XMainframe Hardware OptionsRequired: STB, PLK (N1000A)Optional: LOJ/PTB (not used with N1060A)Mainframe Software Options(Fixed or TransportableLicenses)Required: N1010100APlug-In Module Model No Plug-In Module OptionsMax # of Modules/Diff Channelssupported by N109212CAN1060A1/1 (slot 1 only)Required: 264/050 Optional: 085SoftwareN109212CAElectrical TX Test SW for OIF-CEI-112GN1010AFlexDCA FW Rev 6.6 or later (included with N1000A mainframe)Keysight IO librariesRev 16.3 or later, automatically installed with FlexDCA installationAccessoriesN1060AN1060A: No accessories are required (all modules include integrated de-skew)N1060A-DC2DC blocks, 50 GHz (Qty 2)N1060A-CA2Matched cable set (Qty 1)Model No. (Pick TDR orPNA)DescriptionN1055A TDR/TDT150 GHz 2/4 Port TDR/TDT Remote Sampling Head for the N1000A DCA-X(any option) equipped with one of the following SW licenses: N1010200A,N1010300ANetwork analyzer4-port PNA’s greater than 58 GHz (e.g. N5227B, N5247A)Find us at www.keysight.comPage 15

Solution 2: Keysight N1000A DCA-X Mainframe with DCA Module External Clock Recovery Highest flexibility Scalable solutionTX test using digital communications analyzer (DCA) High fidelity – remote heads minimize loss between DUT and oscilloscopeFind us at www.keysight.comPage 16

Equipment configuration for solution 2: Keysight N1000A DCA-X Mainframe with DCA Module External Clock RecoveryMainframe Model NoMainframe Hardware OptionsMainframe Software Options(Fixed or Transportable Licenses)N1000A DCA-XRequired: PLK/LOJ/PTB (N1000A)Required: N1010100APlug-In Module ModelNo (Pick ONE)Plug-In Module OptionsMax # of Modules/Diff Channelssupported by N109212CAN1045A/BAny2/4 (slot 1 & slot 2 only)N1046A12F, 14F, 72F, 74F, 82F, 84F (any 2 or 42/4 (slot 1 & slot 2 only)channel config)N1040A060Clock Recovery ModelNo (Pick ONE)Clock Recovery OptionsN1076B264N1078A2642/2 (slot 1 & slot 2 only)SoftwareN109212CAElectrical TX Test SW for OIF-CEI-112GN1010AFlexDCA FW Rev 6.6 or later (included with N1000A mainframe)Keysight IO librariesRev 16.3 or later, automatically installed with FlexDCA installationAccessories1.N1027A-76B (rec.)Clock Recovery Phase Matching Kit for use with N104XA remote head andN107X CRN1027A-78A (rec.)Clock Recovery Phase Matching Kit for use with N104XA remote head andN107X CRN1027A-2P2Pick-Off Tees (Qty 2), for remote head modules with 1.85 mm/2.4 mmconnectors (N1045A/B, N1046A), (included in N1027A-76A/76B Kit)N9398F or N9399FDC block, 50 GHz (Qty 2)Mode (TDR or PNA)DescriptionN1055A TDR/TDT150 GHz 2/4 Port TDR/TDT Remote Sampling Head for the N1000A DCA-X(any option) equipped with one of the following SW licenses: N1010200A,N1010300ANetwork analyzer4-port PNA’s greater than 58 GHz (e.g. N5227B, N5247A)Only supports return loss measurement at Host-to-Module (TP1a) & Module-To-Host (TP4) of VSRFor more information on clock-to-data delay matching, refer to the Keysight N1076A/B, N1077A, and N1078A ClockRecovery DCA-M User GuideFind us at www.keysight.comPage 17

Ordering InformationThe N109212CA Electrical TX Test SW for OIF-CEI-112G may be licensed using any of four differentmethods. Choose a license type and term that best suits your requirements.License Types:1. Node-locked: Allows you to use the license on one specified instrument or computer.2. Transportable: Allows you to move the license from one instrument or computer to anotherusing Keysight’s online tool.3. USB portable: Allows you to move the license from one instrument or computer to anotherwith a certified USB dongle.4. Floating: Allows you to access the license on networked instruments or computers from aserver, one at a time. Three types of floating license are available:a. Single Site: 1-mile radius from the serverb. Single Region1: Americas; Europe; Asia;c.Worldwide: export restriction identified in END User License Agreement (EULA)Ame ricas (North , Central, and South America, Canada); Europe (European Continen t, Middle Easte rn Europe, Africa,India ); Asia (North and South Asia Pacific Countries, China, Taiwan, Japan)Find us at www.keysight.comPage 18

License terms:Each of the license types are offered as perpetual (licenses can be used indefinitely) or subscription(licenses can be used through the term of the license: 6, 12, 24, or 36 months).KeysightCare Software Support Subscription: Perpetual licenses are sold with a 12 (default), 24, 36, or 60-month KeysightCare softwaresupport subscription Software subscription licenses include KeysightCare Software Support through the term ofthe licenseFor more information, visit: KeysightCare Software Support Subscriptions, 5992-3419EN.Required Software OptionsThe N109212CA software requires that the N1010100A R&D Package be licensed on the platform.Learn more at: www.keysight.comFor more information on Keysight Technologies’ products, applications or services,please contact your local Keysight office. The complete list is available at:www.keysight.com/find/contactusFind us at www.keysight.comThis information is subject to change without notice. Keysight Technologies 2021, Published in USA, March 12, 2021, 3121-1050.ENPage 19

Several industry and standards bodies have defined specifications for 100 Gb/s high speed electrical interface using PAM4 coding. As an example, an implementation agreement (IA) developed by the Optical Internetworking Forum – Common Electrical Interface (OIF-CEI) defines 112 Gb/s op

Related Documents:

Mar 12, 2020 · 11G 25G & 28G 56G CEI-3.1 CEI-4.0 112G The Common Electrical IO (CEI)

CEI 61439 Quadri elettrici. CEI 23 -51 Quadri elettrici modulari. CEI 23 -3 Interruttori automatici. CEI 23 -44 Interruttori differenziali. CEI 11 -8 impianti di messa a terra. CEI 64 -8 impianti elettrici in generale e cap. 7 per luoghi a maggior rischio in caso di incendio. CEI 23 -51 quadri elettrici (quadri di BT con Ino 125A )

16247-1:2012 Requisiti generali UNI CEI EN 16247-2:2014 Edifici UNI CEI EN 16247-3:2014 Processi UNI CEI EN 16247-5 Qualificazione degli Energy Auditors (2015) UNI CEI EN 16247-4:2014 Trasporti UNI CEI EN 16247 9 . UNI CEI EN 1624

7 TRASFORMATORI ED ALIMENTATORI PER APPLICAZIONI VARIE di potenze varie con correnti da 1 a 10 A conformi a norme CEI EN 61558 – CEI 96.7 – 96.8 - BOBINE E AVVOLGIMENTI realizzati secondo le norme CEI EN 61558 – CEI 96.7 – 96.8 - Si realizzano tutti i tipi di bobine

o UNI CEI EN 16247-1:2012 Diagnosi energetiche – Aspetti generali o UNI CEI EN 16247-2:2014 Diagnosi energetiche – Edifici o UNI CEI EN 16247-3:2014 Diagnosi energetiche – Processi o UNI CEI EN 16247-4:2014 Diagnosi energetiche – Trasporti o UNI CEI/TR 11428:2011 Gestione del

2.2. OIF-CEI Implementation Agreements (IAs) from OIF-CEI do not prescribe compliance tests the way that IEEE’s 802.3 100 GbE or Fibre Channel specifications do. Instead, the emphasis is on informative and normative tests that attem

Jun 12, 2018 · N1012A OIF CEI 3.1 Compliance and Debug Application for 86100D DCA-X and N109X DCA-M Oscilloscopes . Designers are creating innovative network elements that allow up to 100 Gb/s, whi

Key words: Organization, Classical theory, Taylor, Fayol and Weber. Introduction The society we belong is an organizational society. Modern society has retained high morale value of rationality, efficiency and effectiveness in contrast to previous society (Etzioni, 1964). There are relationships between individuals and organizations. It is