Test Report issued under the responsibility of:TEST REPORTIEC 60335-2-30Safety of household and similar electrical appliancesPart 2: Particular requirements for room heatersReport Number. . :21144121 006Date of issue . :08.06.2015Total number of pages .105Applicant’s name . :eCO2heat GmbHAddress . :Zu den Sandbeeten 1; D – 35043 MarburgTest specification:Standard . :IEC 60335-2-30 (Fifth Edition) :2009 used in conjunction withIEC 60335-1:2010 (Fifth Edition)Test procedure. :GSNon-standard test method . .: N/ATest Report Form No. . :IEC60335 2 30JTest Report Form(s) Originator. :LCIEMaster TRF . :Dated 2013-09Copyright 2013 Worldwide System for Conformity Testing and Certification of ElectrotechnicalEquipment and Components (IECEE), Geneva, Switzerland. All rights reserved.This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged ascopyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resultingfrom the reader's interpretation of the reproduced material due to its placement and context.If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CBScheme procedure shall be removed.This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratoryand appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.Test item description .:Infrared Room Heater (fixed used)Trade Mark . :eCO2heatManufacturer . :As applicantModel/Type reference . :1) 70150SHTRatings . :230V 50/60Hz 1) 470W2) 70200SHT2) 630Wcl. II IPX1

Page 3 of 105Report No.21144121 006List of Attachments (including a total number of pages in each attachment):Photo documentation 21144121 006FD (5 pages)European group differences and national differences (at the end of this report page 92-105)PAH report 21144121 006PAK (1page)Summary of testing: passTests performed (name of test and test clause):IEC 60335-2-30 (Fifth Edition) :2009 used inconjunction with IEC 60335-1:2010 (Fifth Edition)EN 60335-2-30:2009 A11: 2012 used inconjunction with EN 60335-1:2012 A11:2014EN 62233:2008Testing location:TÜV Rheinland LGA Products GmbHAm Grauen Stein 29 ; 51105 CologneAfPS GS 2014:01This is a re-examination of the deviations off thetest report 21144121 005F.Summary of compliance with National DifferencesCENELEC COMMON MODIFICATIONS (EN) passed.National differences have been tested.TRF No. IEC60335 2 30J

Page 4 of 105Copy of marking plateRepresentive for all samplesOn backside of sample:On frontside of sample:Example text (for durable test) normally 70200SHT:TRF No. IEC60335 2 30JReport No.21144121 006

Page 5 of 105Report No.21144121 006Test item particulars .:Classification of installation and use .: Class II – fixed IR heating elementsSupply Connection .: Power supply is connected with a plug.:Possible test case verdicts:- test case does not apply to the test object . : N/A- test object does meet the requirement . : P (Pass)- test object does not meet the requirement . : F (Fail)Testing. :Date of receipt of test item. : 11.05.2015 (test item no.: A000097175-001)Date (s) of performance of tests . : 08.06.2015General remarks:The test results presented in this report relate only to the object tested.This report shall not be reproduced, except in full, without the written approval of the Issuing testinglaboratory."(see Enclosure #)" refers to additional information appended to the report."(see appended table)" refers to a table appended to the report.Throughout this report acomma /point is used as the decimal separator.This is a standard update from:EN 60335-1:2002 A11:2004 A1:2004 A12:2006 A2:2006 A13:2008 A14:2010 A15:2011EN 60335-2-30:2003 A1:2004 A2:2007EN 62233:2008To the standards which are listened one page 3.This is a re-examination of the deviations off the test report 21144121 005F. Only the deviations (7.12; 7.14;25.15; 25.17; 22.Z102) were tested in this test report. All other results are taken over from test report21144121 005F.SAP order no.: 3129964The product is suitable for its intended purpose. Foreseeable use was considered. Currently neither asafeguard clause procedure has been invoked nor is an increase in accidents known for this / these product.Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02:The application for obtaining a CB Test Certificateincludes more than one factory location and adeclaration from the Manufacturer stating that thesample(s) submitted for evaluation is (are)representative of the products from each factoryhas been provided . :YesNot applicableWhen differences exist; they shall be identified in the General product information section.TRF No. IEC60335 2 30J

Page 6 of 105Name and address of factory (ies) . :Report No.21144121 006eCO2heat GmbHZu den Sandbeeten 1D – 35043 MarburgGeneral product information:-The device is an IR heating device for wall and ceiling mounting.The connection is given by a plug.Switches and Knobs for the temperature adjustment are not given.The device is designed in metal.The tests are prepared by the maximum configuration on an IR heating deviceThe models 470W (Type: 70150SHT) and 630W (Type: 70200SHT) are only for wall mounting.(noted at the assembly instruction)Model references and rated inputs:SHT Slawinski Heiz TapeteModel70150 SHT70200 SHTTRF No. IEC60335 2 30JRating470W630W

Page 7 of 105Report No.21144121 006IEC 60335-2-30ClauseRequirement TestResult - RemarkVerdict5GENERAL CONDITIONS FOR THE TESTSPTests performed according to cl. 5, e.g. nature ofsupply, sequence of testing, etc.P5.2Heaters intended to be installed adjacent to eachother, tests made with sufficient number.(IEC 60335-2-30)N/A5.3Appliance used for tests of Cl. 19 also used for thetest of Cl. 22.24(IEC 60335-2-30)N/ATest of Cl. 22.24 carried out after test of Cl. 29(IEC 60335-2-30)N/AThermostats short-circuited if sensible to room airtemperature(IEC 60335-2-30)N/AHowever, if the thermostat can be set so that it doesnot cycle, it is not short-circuited, unless otherwisespecified(IEC 60335-2-30)N/A5.10Heaters intended to be installed adjacent to eachother, installed in accordance with instructions(IEC 60335-2-30)N/A5.101Only fixedHeaters intended to be used as both portable andfixed appliances are subjected to the tests applicableto both types(IEC 60335-2-30)N/A5.102If the heater is a combination of two or more types,tests relevant for each type(IEC 60335-2-30)N/AHeaters for wall-mounting are tested both as heatersfor mounting high level and as heaters for mountingother than at high level(IEC 60335-2-30)P5.6N/AUnless the installation instructions state that the heaterhas to be installed at least 1,8m above the floor.(IEC 60335-2-30)P6CLASSIFICATION6.1Protection against electric shock:Class 0, 0I, I, II, III . :Class IIP6.2Protection against harmful ingress of waterIPX1PHeaters intended for use in greenhouses or buildingsites shall be at least IPX4(IEC 60335-2-30)Not for such useN/AP7MARKING AND INSTRUCTIONS7.1Rated voltage or voltage range (V) . :230VPSymbol for nature of supply, or . :HzPTRF No. IEC60335 2 30J

Page 8 of 105Report No.21144121 006IEC 60335-2-30ClauseRequirement TestResult - RemarkVerdictRated frequency (Hz). :50/60HzPRated power input (W): . :630W Typ 70200SHTP470W Typ 70150SHTN/ARated current (A) . :Manufacturer's or responsible vendor's name,trademark or identification mark . :eCO2heat GmbHZu den Sandbeeten 1,35043 MarburgModel or type reference . :70150SHT; 70200SHTPSymbol 5172 of IEC 60417, for Class II appliancesIP number, other than IPX0 . :PIPX1PSymbol IEC 60417-5180, for class III appliances,unlessN/Athe appliance is operated by batteries onlyN/ASymbol IEC 60417-5036, for the enclosure ofelectrically-operated water valves in external hosesets for connection of an appliance to the watermains, if the working voltage exceeds extra-lowvoltageN/ASymbol IEC 60417-5036, for the enclosure ofelectrically-operated water valves in external hose-setsfor connection of an appliance to the water mainsN/AHeaters intended to be filled with liquid by the usershall be marked with max. and min. levelsIEC 60335-2-30)N/AHeaters shall be marked:WARNING”Do not cover”- or with the symbol 5641 of IEC 60417-1 except forcolours(IEC 60335-2-30)This Marking is not required for-Symbol(IEC 60335-2-30)PP- Heaters for mounting high level; (IEC 60335-2-30)N/A- visible glowing radiant heatersN/A(IEC 60335-2-30)- heaters constructed so that they cannot be covered:(IEC 60335-2-30)N/A- heaters also intended to dry clothes and witch complywith IEC 60335-2-43(IEC 60335-2-30)N/A-heaters for mounting under benchesN/A(IEC 60335-2-30)TRF No. IEC60335 2 30J

Page 9 of 105Report No.21144121 006IEC 60335-2-30Clause7.27.37.47.57.6Requirement TestResult - RemarkVerdictHeaters having a fireguard that is intended to beremoved for transportation or storage shall be markedto state that the heater must not be operated withoutthis guard in place(IEC 60335-2-30)N/AFor ceiling mounting heat lamp appliances, themaximum rated wattage and type of each lamp shallbe marked(IEC 60335-2-30)N/AWarning for stationary appliances for multiple supplyOnly single supplyN/AWarning placed in vicinity of terminal coverN/ARange of rated values marked with the lower andupper limits separated by a hyphenN/ADifferent rated values marked with the valuesseparated by an oblique strokeN/AAppliances adjustable for different rated voltages, thevoltage setting is clearly discernibleOnly one voltageN/ARequirement met if frequent changes are notrequired and the rated voltage to which the applianceis to be adjusted is determined from a wiring diagramN/AAppliances with more than one rated voltage or one or Only one voltagemore rated voltage ranges, marked with rated input orrated current for each rated voltage or range, unlessN/Athe power input is related to the arithmetic mean valueof the rated voltage rangeN/ARelation between marking for upper and lower limits ofrated power input or rated current and voltage is clearN/APCorrect symbols usedSymbol for nature of supply placed next to ratedvoltageNo symbol, only HzinformationsN/ASymbol for class II appliances placed unlikely to beconfused with other markingPUnits of physical quantities and their symbolsaccording to international standardized systemPSymbol 5641 of IEC 60417-1 (do not cover) is usedexcept for colours(IEC 60335-2-30)Not able to coverN/A7.7Connection diagram fixed to appliances to beconnected to more than two supply conductors andappliances for multiple supplyOnly single supply with anapproved plugN/A7.8Except for type Z attachment, terminals for connection to the supply mains indicatedas follows:- marking of terminals exclusively for the neutralconductor (N)TRF No. IEC60335 2 30JEquipped with a plug, noterminalsN/AN/A

Page 10 of 105Report No.21144121 006IEC 60335-2-30ClauseRequirement Test- marking of protective earthing terminals (symbol5019 of IEC 60417)Result - RemarkClass II applianceVerdictN/AN/A- marking not placed on removable partsNo switchN/A7.9Marking or placing of switches which may cause ahazard7.10Indications of switches on stationary appliances andcontrols on all appliances by use of figures, letters orother visual means. :N/AThis applies also to switches which are part of acontrolN/AIf figures are used, the off position indicated by thefigure 0N/AThe figure 0 indicates only OFF position, unless noconfusion with the OFF positionN/ANo adjusting devicesN/A7.11Indication for direction of adjustment of controls7.12Instructions for safe use providedPDetails concerning precautions during usermaintenancePThe instructions state that:N/A- the appliance is not to be used by personsNew requirements in part(including children) with reduced physical, sensory or EN60335-2-30mental capabilities, or lack of experience andknowledge, unless they have been given supervisionor instructionN/A- children being supervised not to play with theapplianceN/AFor a part of class III construction supplied from adetachable power supply unit, the instructions statethat the appliance is only to be used with the unitprovidedN/AInstructions for class III appliances state that it mustonly be supplied at SELV, unlessN/Ait is a battery-operated appliance, the battery beingcharged outside the applianceN/AInstructions for safe use provided: .(IEC 60335-2-30)P- If Symbol 5641 of IEC 60417-1 (do not cover) ismarked on the appliance, its meaning is explained.(IEC 60335-2-30)P-For heaters marked ”Do not cover” (or with symbol)contain the substance of:PIn order to avoid overheating, do not cover the heater(IEC 60335-2-30)TRF No. IEC60335 2 30J

Page 11 of 105Report No.21144121 006IEC 60335-2-30ClauseRequirement Test-Statement: heater is not located immediately belowa socket-outlet(IEC 60335-2-30)Result - RemarkWritten down in manualVerdictPN/A-Statement for heaters with heating elements indirect contact with accessible panel made of glass,ceramic or similar material , includes the followingwarning:The heater must not be used if the glass (or ceramicor similar material) panels are damaged(IEC 60335-2-30)-Statements for visibly glowing radiant heaters, otherthan heaters for mounting at high level, includes thesubstance of following:Do not use the heater with a programmer, timer orany other device that switches the heater onautomatically(IEC 60335-2-30)N/A-have a fireguard that can be partly removed without the aid of a tool includes thesubstance of following: .(IEC 60335-2-30)N/AThe fireguard of this heater is intended to preventdirect access to heating elements and must be inplace when the heater is used.N/AThe fireguard does not give full protection for youngpeople and infirm personsN/A-Statements for portable heaters :Do not use this heater in the immediate surroundingsof a bath, a shower or a swimming pool(IEC 60335-2-30)N/A-Statements for visibly glowing radiant heaters: shallbe provided for cleaning the reflector, if appropriate(IEC 60335-2-30)N/A-Statement: shall be provided for replacing the lampsof fuel-effect heaters(IEC 60335-2-30)N/A-Statements for oil-filled radiators: .(IEC 60335-2-30)N/A- this heater is filled with a precise quantity of specialoil. Repairs requiring opening of the oil containerare only to be made by the manufacturer or hisservice agent who should be contacted if there is anoil leakageN/A- regulations concerning the disposal of oil whenscrapping the appliance have to be followedInstructions shall be provided for routine cleaning ofceiling mounted heat lamp appliances includingremoval of covers if applicable (IEC 60335-2-30)N/ATRF No. IEC60335 2 30JN/A

Page 12 of 105Report No.21144121 006IEC 60335-2-30Clause7.12.1Requirement TestResult - RemarkVerdictThe instructions for room heaters without a built- Written down in manual onin room thermostat or thermal control limiting the page 2.room temperature shall include the substance ofthe following:WARNING: This heater is not equipped with adevice to control the room temperature. Do notuse this heater in small rooms when they areoccupied by persons not capable of leaving theroom on their own, unless constant supervision isprovided.PSufficient details for installation suppliedPN/AFor an appliance intended to be permanentlyconnected to the water mains and not connected bya hose-set, this is statedInstructions for heaters intended to be fixed by screws A detailed instruction forinstallation and screws isor other give details on the method of fixinggiven by the heating device.(IEC 60335-2-30)PInstructions for visibly glowing radiant heaters warnabout the possible danger of installation close tocurtains and other combustible materials(IEC 60335-2-30)N/AInstructions for heaters for mounting at high level statethat the heater must be installed at least 1,8 m abovethe floor(IEC 60335-2-30)N/AInstructions for fixed heaters likely to be used in abathroom: that the heater is to be installed so thatswitches and other controls cannot be touched by aperson in the bath or shower(IEC 60335-2-30)Written down in manualPStatement for heaters with rollers or feet deliveredseparately: how they have to be fixed(IEC 60335-2-30)N/AStatement for heaters intended to be installed inwardrobes or ceiling: for proper installation in awardrobe or in the ceiling(IEC 60335-2-30)N/AThe installation instructions for ceiling mounted heat lamp appliances, recessed intoa ceiling place or cavity shall give details for proper installation in the ceiling andshall state the substance of the following: .(IEC 60335-2-30)N/A-The appliance shall, under no circumstances, becovered with insulating material or similar material.N/A-Regulations concerning the discharge of air have tobe fulfilled.N/A-Joists, beams and rafters shall not be cut or notchedto install the applianceN/AThe installation instructions for heaters for mounting under church benches shallstate: .(IEC 60335-2-30)N/ATRF No. IEC60335 2 30J

Page 13 of 105Report No.21144121 006IEC 60335-2-30ClauseRequirement TestResult - RemarkVerdict-The heater is intended for installation under benchesthat are fixed in positionN/A- The minimum distance between the underside ofthe installed heater and the floorN/A-The minimum distances of the relevant surfaces ofthe heaters to the front and rear edge of theunderside of the bench which shall be not less than50 mmN/AThe installation instructions for heaters intended tobe built into the floor and that incorporatea floor level grille shall state the substance of thefollowing:(IEC 60335-2-30)After installation, ensure that any drain holes are freefrom obstruction.N/AEnsure that any floor level grille has a mechanicalstrength consistent with the national building codes.(IEC 60335-2-30)N/A7.12.2Stationary appliances not fitted with means fordisconnection from the supply mains having a contactseparation in all poles that provide full disconnectionunder overvoltage category III, the instructions statethat means for disconnection must be incorporated inthe fixed wiring in accordance with the wiring rulesThe device is equipped with acable and a connectorN/A7.12.3Insulation of the fixed wiring in contact with partsexceeding 50 K during clause 11; instructions statingthat the fixed wiring must be protectedNo permanent installedequipment as described inthis partN/A7.12.4Instructions for built-in appliances:N/A- dimensions of spaceN/A- dimensions and position of supporting meansN/A- minimum distances between parts and surroundingstructureN/A- minimum dimensions of ventilating openings andarrangementN/A- connection to supply mains and interconnection ofseparate componentsN/A- allow disconnection of the appliance after installation,by accessible plug or a switch in the fixed wiring,unlessN/Aa switch complying with 24.3N/AReplacement cord instructions, type X attachment witha specially prepared cordN/A7.12.5Replacement cord instructions, type Y attachmentTRF No. IEC60335 2 30JHave to contact the customerserviceP

Page 14 of 105Report No.21144121 006IEC 60335-2-30ClauseRequirement TestResult - RemarkN/AReplacement cord instructions, type Z attachment7.12.6Caution in the instructions for appliancesincorporating a non-self-resetting thermal cut-outthat is reset by disconnection of the supply mains, ifthis cut-out is required to comply with the standardNo such parts given7.12.7Instructions for fixed appliances stating how theappliance is to be fixedA detailed instruction is given7.12.8Instructions for appliances connected to the water mains:- max. inlet water pressure (Pa):VerdictA connection to the watermains is not usedN/APN/AN/A- min. inlet water pressure, if necessary (Pa):N/AInstructions concerning new and old hose-sets forappliances connected to the water mains bydetachable hose-setsN/AGermanP7.13Instructions and other texts in an official language7.14Marking clearly legible and durablePThe height of the “Do not cover “ symbol shall be atleast 15 mm(IEC 60335-2-30)PThe height of the words “Do not cover “ shall be atleast 3 mm(IEC 60335-2-30)This symbol is not in useN/AThe height of the words relating to the maximumrated wattage and type of heat lamp shall be at last6mm(IEC 60335-2-30)7.15N/AMarking on a main partPMarking clearly discernible from the outside, ifnecessary after removal of a coverPFor portable appliances, cover can be removed oropened without a toolNot portableFor stationary appliances, name, trademark oridentification mark and model or type reference visibleafter installationN/AN/AFor fixed appliances, name, trademark or identification Eco2heatmark and model or type reference visible after70200SHTinstallation according to the instructionsPIndications for switches and controls placed on or near No switchesthe components. Marking not on parts which can bepositioned or repositioned in such a way that themarking is misleadingN/ANot for high levelHeaters for mounting at high level, indication of thedifferent positions of switches visible from a distanceof 1 m(IEC 60335-2-30)N/ATRF No. IEC60335 2 30J

Page 15 of 105Report No.21144121 006IEC 60335-2-30ClauseRequirement TestResult - RemarkVerdictMarking concerning covering visible shall be visibleafter the heater has been installed. It shall not beplaced on the bottom of, or on the back of, portableheaters.(IEC 60335-2-30)PMarking not placed on the back of portable heaters(IEC 60335-2-30)N/AMarking concerning removable fireguards visiblebefore fitting the fireguard(IEC 60335-2-30)N/AFor ceiling mounted heat lamp appliances, themarking relating to the maximum rated wattage andtype of heat lamp shall be visible when replacing alamp in accordance with the instructions(IEC 60335-2-30)N/ANo replaceable fuseN/A7.16Marking of a possible replaceable thermal link or fuselink clearly visible with regard to replacing the link8PROTECTION AGAINST ACCESS TO LIVE PARTSP8.1Adequate protection against accidental contact withlive partsPThis requirement does not apply to live parts of screw- No such parts giventype or bayonet-type lampholders incorporated inceiling mounted heat lamp appliances that are onlyaccessible when the heat lamp is extractedN/A(IEC 60335-2-30)8.1.1Requirement applies for all positions, detachable partsremovedLamps behind a detachable cover not removed, ifconditions metN/AInsertion or removal of lamps, protection againstcontact with live parts of the lamp capN/AUse of test probe B of IEC 61032: no contact with liveparts8.1.2PPDetachable fireguards not removed if their removal requires the use of a tool,provided that(IEC 60335-2-30)N/A- the instructions state that the plug must be removedfrom the socket-outlet before cleaning the reflector, orN/A- the heater incorporates a switch having contactseparation all poles that provides full disconnectionunder overvoltage category III conditionsN/AUse of test probe 13 of IEC 61032 through openings inclass 0 appliances and class II appliances/constructions: no contact with live partsTRF No. IEC60335 2 30JP

Page 16 of 105Report No.21144121 006IEC 60335-2-30ClauseRequirement TestTest probe 13 also applied through openings inearthed metal enclosures having a non-conductivecoating: no contact with live parts8.1.4No openingsAccessible part not considered live if:- safety extra-low a.c. voltage: peak value notexceeding 42.4 V8.1.5Result - RemarkN/AN/ANo such parts givenN/A- safety extra-low d.c. voltage: not exceeding 42.4 VN/A- or separated from live parts by protective impedanceN/AIf protective impedance: d.c. current not exceeding2 mA, andN/Aa.c. peak value not exceeding 0.7 mAN/A- for peak values over 42.4 V up to and including450 V, capacitance not exceeding 0,1 µFN/A- for peak values over 450 V up to and including 15 kV,discharge not exceeding 45 µCN/A-for peak values over 15kV, the energy in thedischarge not exceeding 350 mJN/ALive parts protected at least by basic insulation before installation or assembly:N/A- built-in appliancesN/AP- fixed appliancesN/A- appliances delivered in separate units8.2VerdictClass II appliances and constructions constructed sothat there is adequate protection against accidentalcontact with basic insulation and metal parts separatedfrom live parts by basic insulation onlyPOnly possible to touch parts separated from live partsby double or reinforced insulationPNo parts to removalDuring user maintenance and after the removal ofdetachable parts during replacement of heat lamp, thebasic insulation of internal wiring may be touchedprovided electrically equivalent to the insulation ofcords complying with IEC 60227 or IEC 60245(IEC 60335-2-30)10POWER INPUT AND CURRENT10.1Power input at normal operating temperature, ratedvoltage and normal operation not deviating from ratedpower input by more than shown in table 1Test carried out at upper and lower limits of theranges for appliances with one or more rated voltageranges, unlessTRF No. IEC60335 2 30JN/AP(see appended table)PP

Page 17 of 105Report No.21144121 006IEC 60335-2-30ClauseRequirement TestResult - Remarkthe rated power input is related to the arithmeticmean value10.2VerdictPCurrent at normal operating temperature, rated voltage (see appended table)and normal operation not deviating from rated currentby more than shown in table 2N/ATest carried out at upper and lower limits of theranges for appliances with one or more rated voltageranges, unlessN/Athe rated current is related to the arithmetic meanvalue of the rangeN/A11HEATINGP11.1No excessive temperatures in normal useP11.2Placing and mounting of applianceP-Portable fan heatersN/A-Other heaters normaly placed on a floorN/A-Fixed heater for mounting at high levelN/A-Other fixed heaters for wall mounting11.3(IEC 60335-2-30)P-Heaters for ceiling mounting)N/A-Heaters for mounting under benchesN/A- Built-in heatersN/A- Fixed heater with opening at floor level, felt padpushed flat into the openingN/A-Heaters having an air-outlet grille intended to berecessed in a floor, a window-sill or similarN/A-Appliance provided with an automatic cord reelN/A-Appliance with cord storage devices, other thanautomatic cord reel intended to accommodate supplycord partially while the appliance is in operationN/A-Ceiling mounted heat lamp appliancesN/A-Recessed ceiling mounted heat lamp appliances aremounted as near as possible to the wallsN/ATemperature rises, other than of windings, determinedby thermocouplesPTemperature rises of windings determined byresistance method, unlessN/Athe windings makes it difficult to make the necessaryconnectionsN/ATRF No. IEC60335 2 30J

Page 18 of 105Report No.21144121 006IEC 60335-2-30ClauseRequirement TestResult - RemarkN/ATemperature rise of the felt pad (IEC 60335-2-30)11.4VerdictHeating appliances operated under normal operationat 1.15 times rated power input . :70150SHT: 540,5WIf the temperature rise limits are exceeded inappliances incorporating motors, transformers orelectronic circuits and the power input is lower thanthe rated power input, the test is repeated with theappliance supplied at 1.06 times rated voltage.(IEC 60335-2-30)The temperature rise limitsare not exceeded.P70200SHT: 945WN/A11.5Motor-operated appliances operated under normaloperation at most unfavourable voltage between 0.94and 1.06 times rated voltage . :N/A11.6Combined appliances are operated as heatingappliances .(IEC 60335-2-30)N/A11.7Operation until steady conditions established(IEC 60335-2-30)P11.8Temperature rises monitored continuously and notexceeding the values in table 3 . :(see appended tables)PIf the temperature rise of a motor winding exceedsthe value of table 3, orN/Aif there is doubt with regard to classification ofinsulation,N/Atests of Annex C are carried outN/APProtective devices do not operate, exceptcomponents in protective electronic circuits tested forthe number of cycles specified in 24.1.4No electronicN/ASealing compound does not flow outPModification of temperature rise in table 3(IEC 60335-2-30)PN/ATemperature rise limits of motors, transformers orcomponents of electronic circuits and other partsmay be exceed by 1.15 times rated power input(IEC 60335-2-30)Outer surface of liquid container of unvested liquidfilled radiators shall be at least 50 K less than theboiling point of liquid(IEC 60335-2-30)Boiling-point: . CTemperature rise of surfaces shall not exceed thevalues in table 101(IEC 60335-2-30)(see appended table)-Heaters intended to be

(IEC 60335-2-30) N/A 5.3 Appliance used for tests of Cl. 19 also used for the test of Cl. 22.24 (IEC 60335-2-30) N/A Test of Cl. 22.24 carried out after test of Cl. 29 (IEC 60335-2-30) N/A 5.6 Thermostats short-circuited if sensible to room air temper

Related Documents:

Effective date: Apr 30, 2020 . IEC/EN 60335-1, IEC/EN 60335-2-2 CNS 3765, CNS 3765-2 100128 電熨斗 IEC/EN 60335-1, IEC/EN 60335-2-3 CNS 3765, CNS 3765-3 100129 旋轉式脫水機 IEC/EN 60335-1, IEC/EN 60335-2-4 CNS 3765-4, CNS 2926 sub-clause 3.3, 3.4 100130 洗碗機 IEC/EN 60335-1

Mar 26, 2019 · (IEC 60335-2-40:2018) Not a refrigerating system NA 5.101 Motor-compressor subjected to relevant test of clause 19 of IEC 60335-2-34, unless (IEC 60335-2-40:2018) Not a refrigerating system NA motor-compressor comply with that standard (IEC 60335-2-40:2018) Not a refrigerating

IEC 61215 IEC 61730 PV Modules Manufacturer IEC 62941 IEC 62093 IEC 62109 Solar TrackerIEC 62817 PV Modules PV inverters IEC 62548 or IEC/TS 62738 Applicable Standard IEC 62446-1 IEC 61724-1 IEC 61724-2 IEC 62548 or IEC/TS 62738 IEC 62548 or IEC/TS 62738 IEC 62548 or IEC/TS 62738 IEC 62548 or IEC/

-A concerning IEC/EN 60335-2-29 (4th Edition) and IEC/EN 60335-1 (4th Edition) -B concerning IEC/EN 60335-1 (5th Edition) the two reports should be used together Based on the above information, the sample has been tested and found compliant with the requirement of the safety standards l

DIN EN 60335-1;VDE 0700-1:2020-08 AS/NZS 60335.1:2011 A1:2012 A2:2014 A3: 2015 A4:2017 A5:2019 IEC 60335-2-2:2009 A1:2012 A2:2016 EN 60335-2-2:2010 A11 A1:2013 DIN EN 60335-2-2:2014 A2:2015 VDE 0700-2: 2014 A1:2015 Household and similar electrical appliances – Safety – Part 2-2:

IEC/EN 62031 IEC/EN 62471 IEC 60598-1 ENEC IEC/EN 61347-2-13 (Relevant clauses) Relevant clauses of IEC/EN 60335-1 Annex BB of IEC/EN 60335-2-89 Annex CC of IEC/EN 60335-2-24 NSF UL 2108 CSA C22.2 No.9.0-96 Environmental RoHS/REACH Application IP rating No IP-rating, fit for use in

IEC has formed IECRE for Renewable Energy System verification - Component quality (IEC 61215, IEC 61730, IEC 62891, IEC 62109, IEC 62093, IEC 61439, IEC 60947, IEC 60269, new?) - System: - Design (IEC TS 62548, IEC 60364-7-712, IEC 61634-9-1, IEC 62738) - Installation (IEC 62548, IEC 60364-7-712)

23. Sharma, P. D. [1991] : The Fungi (Rastogi & Co. Meerut) 24. Vasishta, B. R. [1990] : Fungi (S. Chand & Co. New Delhi) 25. Sharma, O. P. : Fungi (TMH)