TEST REPORT IEC 60335-2-73 And/or EN 60335-2-73 Safety Of .

2y ago
122 Views
19 Downloads
2.27 MB
23 Pages
Last View : 2d ago
Last Download : 3m ago
Upload by : Olive Grimm
Transcription

Test Report issued under the responsibility of:PCBC S.A.TEST REPORTIEC 60335-2-73 and/or EN 60335-2-73Safety of household and similar electrical appliancesPart 2: Particular requirements for fixed immersion heatersReport Reference No. :BE/303/2011Date of issue . :28.10.2010, Amendment No. 1: 05.07.2011Total number of pages . :CB/CCA Testing Laboratory. :Polskie Centrum Badań i Certyfikacji S.A.Address . :ul. Kłobucka 23A; 02-699 Warszawa; POLANDApplicant’s name. :CINI Sp. z o.o.Address . :ul. Piaskowa 31; 41-253 Czeladź; POLANDTest specification:Standard . :IEC 60335-2-73:2002 (2. Edition) A1:2006IEC 60335-1:2001 (4. Edition) (incl. Corrigendum 1:2002) A1:2004 A2:2006 (incl. Corrigendum 1:2006) and/orEN 60335-2-73:2003 A1:2006EN 60335-1:2002 A1:2004 A11:2004 A12:2006 1A2:2006 A13:2008EN 50366:2003 A1:2006Test procedure . :CB / CCANon-standard test method .:N/ATest Report Form No. :IECEN60335 2 73ATest Report Form(s) Originator . :VDEMaster TRF . :Dated 2007-03Copyright 2007 IEC System for Conformity Testing and Certification of Electrical Equipment(IECEE), Geneva, Switzerland. All rights reserved.This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged ascopyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting fromthe reader's interpretation of the reproduced material due to its placement and context.If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Schemeprocedure shall be removed.This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appendedto a CB Test Certificate issued by an NCB in accordance with IECEE 02.If this Test Report Form is used by non-CCA members, the CIG logo and the reference to the CCA Procedure shall beremoved.This report is not valid as a CCA Test Report unless signed by an approved CCA Testing Laboratory andappended to a CCA Test Certificate issued by an NCB in accordance with CCATest item description .:Electric heater with electronic thermostat.Trade Mark . :CINIManufacturer . :CINIModel/Type reference . :GT 150, GT 300, GT 500, GT 600, GT 900, GT 1200GTX 300, GTX 600, GTX 900Ratings . :(150W, 600W, 900W, 1200W) – 203V; 50Hz; IP54(300W, 500W) – 230-240V; 50Hz; IP54

Page 2 of 23Testing procedure and testing location:CB/CCA Testing Laboratory:Testing location/ address.:Associated CB Laboratory:Testing location/ address.:Tested by (name signature). :Grzegorz FabijańskiApproved by ( signature) . :Aleksander DeskiewiczTesting procedure: TMPTested by (name signature). :Approved by ( signature) . :Testing location/ address.:Testing procedure: WMTTested by (name signature). :Witnessed by ( signature) . :Approved by ( signature) . :Testing location/ address.:Testing procedure: SMTTested by (name signature). :Approved by ( signature) . :Supervised by ( signature) . :Testing location/ address.:Testing procedure: RMTTested by (name signature). :Approved by ( signature) . :Supervised by ( signature) . :Testing location/ address.:TRF No. IECEN60335 2 73AReport No. BE/303/2011

Page 3 of 23Report No. BE/303/2011List of Attachments:This Amendment to the original Report No. BE/198/2010 contains Report Pages and inidnisdunisdSummary of testing:Tests performed (name of test and test clause):Testing location:Cl. 7 - Marking and instructionsCl. 11 – HeatingCl. 16 – Leakage current and electric strengthPCBC S.A.ul. Kłobucka 23A; 02-699 Warszawa; POLANDSummary of compliance with National Differences:TRF No. IECEN60335 2 73A

Page 4 of 23Copy of marking plate:TRF No. IECEN60335 2 73AReport No. BE/303/2011

Page 5 of 23Report No. BE/303/2011Test item particulars. : Heating elements GTX seriesClassification of installation and use. : Class I appliance, unattended useSupply Connection . : Power supply cord with plug with type X attachment. :. :Possible test case verdicts:- test case does not apply to the test object.: N/A- test object does meet the requirement.: P (Pass)- test object does not meet the requirement.: F (Fail)Testing .:Date of receipt of test item .: 03.06.2011Date (s) of performance of tests .: 06.2011General remarks:The test results presented in this report relate only to the object tested.This report shall not be reproduced, except in full, without the written approval of the Issuing testinglaboratory."(See Enclosure #)" refers to additional information appended to the report."(See appended table)" refers to a table appended to the report.Note: This TRF includes EN Group Differences together with National Differences and SpecialNational Conditions, if any. All Differences are located in the Appendix to the main body of this TRF.Throughout this report a comma (point) is used as the decimal separator.1)PCBC TEST REPORT modifications:- EN 60335-1/A13:2008 see Appendix No. 1General product information:This Test Reports covers electric heater with electronic thermostat series GT.Electric heaters GT 150, GT 600, GT 900, GT 1200 are supplied by 230V.Electric heaters GT 300, GT 500 are supplied by 230-240V.Test Report covers also the result test according to standard EN 50366:2003 A1: 2006 (see ANNEX EMF)Amendment 1 Report:The original Test Report No. BE/198/2010, dated 28.10.2010 was modified on 05.07.2011 to include thefollowing changes and/or additions, which were considered technical modifications:New models added:Are electric heater with electronic thermostat identical to the previous Series GT, except for sensor oftemperatures (used capillary sensor ) and markings. After review of the construction, three tests wereconsidered necessary. See the “Summary of testing”.A photos of modifications was added.TRF No. IECEN60335 2 73A

Page 6 of 23Report No. BE/303/2011IEC/EN 60335-2-73ClauseRequirement Test5GENERAL CONDITIONS FOR THE TESTSResult - RemarkPTests performed according to cl. 5, e.g. nature ofsupply, sequence of testing, etc.6CLASSIFICATION6.1Protection against electric shock:Class 0, 0I, I, II, III .:Class IPClass IImmersion heaters shall be class I, class II orclass III.(IEC 60335-2-73)PIP54PRated voltage or voltage range (V) . :230V – GTX 300230-240V – GTX 600; GTX 900PNature of supply. : PRated frequency (Hz). :50HzPRated power input (W). :300W, 600W, 900WP6.2Protection against harmful ingress of water7MARKING AND INSTRUCTIONS7.1N/AAppliances for multiple supply shall be markedwith their rated power input for each supplycircuit.(IEC 60335-2-73)Rated current (A) . :-Manufacturer's or responsible vendor's name,trademark or identification mark . :CINIPModel or type reference. :GTX 300; GTX 600; GTX 900PIP number, other than IPX0 .:Symbol IEC 60417-5036, for the enclosure ofelectrically-operated water valves in external hosesets for connection of an appliance to the watermainsN/AN/ASymbol 5172 of IEC 60417, for Class II appliances7.2VerdictIP54PN/AAppliances shall be marked "Do not cover".(IEC 60335-2-73)PWarning for stationary appliances for multiplesupplyN/AWarning placed in vicinity of terminal coverN/ATRF No. IECEN60335 2 73A

Page 7 of 23Report No. BE/303/2011IEC/EN 60335-2-73ClauseRequirement Test7.3Range of rated values marked with the lower andupper limits separated by a hyphenResult - RemarkVerdictPDifferent rated values marked with the valuesseparated by an oblique strokeN/A7.4Appliances adjustable for different rated voltages,the voltage setting is clearly discernibleN/A7.5Appliances with more than one rated voltage orone or more rated voltage ranges, marked withrated input or rated current for each rated voltageor range, unlessN/Athe power input is related to the arithmetic meanvalue of the rated voltage range230V - 204VPN/ARelation between marking for upper and lowerlimits of rated power input or rated current andvoltage is clearP7.6Correct symbols used7.7Connection diagram fixed to appliances to beconnected to more than two supply conductorsand appliances for multiple supply7.8Except for type Z attachment, terminals for connection to the supply mains indicatedas follows:N/AN/A- marking of terminals exclusively for the neutralconductor (N)- marking of protective earthing terminals (symbol5019 of IEC 60417)P- marking not placed on removable partsP7.9Marking or placing of switches which may cause ahazard7.10Indications of switches on stationary appliancesand controls on all appliances by use of figures,letters or other visual means . :N/ANumbersPThe figure 0 indicates only OFF position, unless noconfusion with the OFF positionP7.11Indication for direction of adjustment of controlsP7.12Instructions for safe use providedPThe instructions state that:- the appliance is not to be used by children orpersons with reduced physical, sensory or mentalcapabilities, or lack of experience and knowledge,unless they have been given supervision orinstructionTRF No. IECEN60335 2 73AP

Page 8 of 23Report No. BE/303/2011IEC/EN 60335-2-73Clause7.12.1Requirement TestResult - RemarkVerdict- children being supervised not to play with theappliancePSufficient details for installation suppliedPThe installation instructions shall include the substance of the following:(IEC 60335-2-73)– the type and dimensions of the tank in whichthe immersion heater can be installed;(IEC 60335-2-73)N/A– the positioning of the immersion heater withinthe tank;(IEC 60335-2-73)P– a statement that the installer must check thatthere is water in the tank before the immersionheater is first switched on;(IEC 60335-2-73)P– a statement that the immersion heater is to beinstalled only in a system where the heatingelement is always below water level, such as in acistern-fed tank, if applicable(IEC 60335-2-73/A1)P7.12.2Stationary appliances not fitted with means fordisconnection from the supply mains having acontact separation in all poles that provide fulldisconnection under overvoltage category III, theinstructions state that means for disconnectionmust be incorporated in the fixed wiring inaccordance with the wiring rules7.12.3Insulation of the fixed wiring in contact with partsexceeding 50 K during clause 11; instructionsstating that the fixed wiring must be protected7.12.4Instructions for built-in appliances:Supply cord with plugPN/A- dimensions of spaceN/A- dimensions and position of supporting meansN/A- distances between parts and surroundingstructureN/A- dimensions of ventilation openings andarrangementN/A- connection to supply mains and interconnectionof separate componentsN/A- allow disconnection of the appliance afterinstallation, by accessible plug or a switch in thefixed wiring, unlessN/Aa switch complying with 24.3N/ATRF No. IECEN60335 2 73A

Page 9 of 23Report No. BE/303/2011IEC/EN 60335-2-73ClauseRequirement TestResult - RemarkVerdict7.12.5Replacement cord instructions, type X attachmentwith a specially prepared cordPReplacement cord instructions, type Y attachmentN/AReplacement cord instructions, type Z attachmentN/A7.12.6Caution in the instructions for heating applianceswith a non-self-resetting thermal cut-outN/A7.12.7Instructions for fixed appliances stating how theappliance is to be fixedP7.12.8Instructions for appliances connected to the water mains:- max. inlet water pressure (Pa) .:-N/A- min. inlet water pressure, if necessary (Pa).:-N/AN/AInstructions concerning new and old hose-sets forappliances connected to the water mains bydetachable hose-setsEnglish, Polish, German, Czech,RussianP7.13Instructions and other texts in an official language7.14Marking clearly legible and durableP7.15Marking on a main partPMarking clearly discernible from the outside, ifnecessary after removal of a coverPFor portable appliances, cover can be removed oropened without a toolN/AFor stationary appliances, name, trademark oridentification mark and model or type referencevisible after installationPFor fixed appliances, name, trademark oridentification mark and model or type referencevisible after installation according to theinstructionsPIndications for switches and controls placed on ornear the components. Marking not on parts whichcan be positioned or repositioned in such a waythat the marking is misleadingP7.16Marking of a possible replaceable thermal link orfuse link clearly visible with regard to replacing thelinkP8PROTECTION AGAINST ACCESS TO LIVE PARTSThis test are not contain in the test program. See "Summary of testing".TRF No. IECEN60335 2 73AN/A

Page 10 of 23Report No. BE/303/2011IEC/EN 60335-2-73ClauseRequirement Test10POWER INPUT AND CURRENTResult - RemarkVerdictN/AThis test are not contain in the test program. See "Summary of testing".11HEATING11.1No excessive temperatures in normal useP11.2Placing and mounting of appliance as describedP11.3Temperature rises, other than of windings,determined by thermocouplesPN/ATemperature rises of windings determined byresistance method, unlessthe windings makes it difficult to make thenecessary connections11.4ThermocouplesHeating appliances operated under normal345W – GTX 300operation at 1.15 times rated power input . : 690W – GTX 600PP1035W – GTX 90011.5Motor-operated appliances operated under normal operation at most unfavourable voltage between0.94 and 1.06 times rated voltage .:N/A11.6Combined appliances operated under normaloperation at most unfavourable voltage between0.94 and 1.06 times rated voltage .:N/A11.7Operation duration corresponding to the mostunfavourable conditions of normal usePAppliances are operated until steady conditionsare established. However, the test is terminatedafter 24 h provided that a thermal control hasoperated.(IEC 60335-2-73)PTemperature rises not exceeding values in table 3 (see appended tables)PSealing compound does not flow outPProtective devices do not operate, exceptP11.813-components in protective electronic circuits testedfor the number of cycles specified in 24.1.4N/ALEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATINGTEMPERATUREN/AThis test are not contain in the test program. See "Summary of testing".TRF No. IECEN60335 2 73A

Page 11 of 23Report No. BE/303/2011IEC/EN 60335-2-73ClauseRequirement Test14TRANSIENT OVERVOLTAGESResult - RemarkVerdictN/AThis test are not contain in the test program. See "Summary of testing".15N/AMOISTURE RESISTANCEThis test are not contain in the test program. See "Summary of testing".16LEAKAGE CURRENT AND ELECTRIC STRENGTH16.1Leakage current not excessive and electricstrength adequatePProtective impedance disconnected from live partsbefore carrying out the testsP16.216.3243,8V – GTX 600; GTX 900Three-phase appliances: test voltage 1.06 timesrated voltage divided by 3.:-Leakage current measurements(see appended table)PElectric strength tests according to table 7(see appended table)P254,4V – GTX 300No breakdown during the tests17PSingle-phase appliances: test voltage 1.06 timesrated voltage .:OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITSN/APN/AThis test are not contain in the test program. See "Summary of testing".19ABNORMAL OPERATIONN/AThis test are not contain in the test program. See "Summary of testing".20STABILITY AND MECHANICAL HAZARDSN/AThis test are not contain in the test program. See "Summary of testing".21MECHANICAL STRENGTHN/AThis test are not contain in the test program. See "Summary of testing".22CONSTRUCTIONThis test are not contain in the test program. See "Summary of testing".TRF No. IECEN60335 2 73AN/A

Page 12 of 23Report No. BE/303/2011IEC/EN 60335-2-73ClauseRequirement Test23INTERNAL WIRINGResult - RemarkVerdictN/AThis test are not contain in the test program. See "Summary of testing".24COMPONENTSN/AThis test are not contain in the test program. See "Summary of testing".25SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDSN/AThis test are not contain in the test program. See "Summary of testing".26TERMINALS FOR EXTERNAL CONDUCTORSN/AThis test are not contain in the test program. See "Summary of testing".27PROVISION FOR EARTHINGN/AThis test are not contain in the test program. See "Summary of testing".28SCREWS AND CONNECTIONSN/AThis test are not contain in the test program. See "Summary of testing".29CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATIONN/AThis test are not contain in the test program. See "Summary of testing".30RESISTANCE TO HEAT AND FIREN/AThis test are not contain in the test program. See "Summary of testing".31RESISTANCE TO RUSTINGN/AThis test are not contain in the test program. See "Summary of testing".32RADIATION, TOXICITY AND SIMILAR HAZARDSN/AThis test are not contain in the test program. See "Summary of testing".AANNEX A (INFORMATIVE)ROUTINE TESTSThis test are not contain in the test program. See "Summary of testing".TRF No. IECEN60335 2 73AN/A

Page 13 of 23Report No. BE/303/2011IEC/EN 60335-2-73ClauseRequirement TestResult - RemarkBANNEX B (NORMATIVE)APPLIANCES POWERED BY RECHARGEABLE BATTERIESVerdictN/AThis test are not contain in the test program. See "Summary of testing".CANNEX C (NORMATIVE)AGEING TEST ON MOTORSN/AThis test are not contain in the test program. See "Summary of testing".DANNEX D (NORMATIVE)THERMAL MOTOR PROTECTORSN/AThis test are not contain in the test program. See "Summary of testing".EANNEX E (NORMATIVE)NEEDLE-FLAME TESTN/AThis test are not contain in the test program. See "Summary of testing".FANNEX F (NORMATIVE)CAPACITORSN/AThis test are not contain in the test program. See "Summary of testing".GANNEX G (NORMATIVE)SAFETY ISOLATING TRANSFORMERSN/AThis test are not contain in the test program. See "Summary of testing".HANNEX H (NORMATIVE)SWITCHESN/AThis test are not contain in the test program. See "Summary of testing".IANNEX I (NORMATIVE)MOTORS HAVING BASIC INSULATION THAT IS INADEQUATE FOR THE RATEDVOLTAGE OF THE APPLIANCEN/AThis test are not contain in the test program. See "Summary of testing".KANNEX K (NORMATIVE)OVERVOLTAGE CATEGORIESThis test are not contain in the test program. See "Summary of testing".TRF No. IECEN60335 2 73AN/A

Page 14 of 23Report No. BE/303/2011IEC/EN 60335-2-73ClauseRequirement TestResult - RemarkLANNEX L (INFORMATIVE)GUIDANCE FOR THE MEASUREMENT OF CLEARANCES AND CREEPAGEDISTANCESVerdictN/AThis test are not contain in the test program. See "Summary of testing".MANNEX M (NORMATIVE)POLLUTION DEGREEN/AThis test are not contain in the test program. See "Summary of testing".NANNEX N (NORMATIVE)PROOF TRACKING TESTN/AThis test are not contain in the test program. See "Summary of testing".OANNEX O (INFORMATIVE)SELECTION AND SEQUENCE OF THE TESTS OF CLAUSE 30N/AThis test are not contain in the test program. See "Summary of testing".PANNEX P (INFORMATIVE)GUIDANCE FOR THE APPLICATION OF THIS STANDARD TO APPLIANCESUSED IN WARM DAMP EQUABLE CLIMATESN/AThis test are not contain in the test program. See "Summary of testing".QANNEX Q (INFORMATIVE)SEQUENCE OF TESTS FOR THE EVALUATION OF ELECTRONIC CIRCUITSN/AThis test are not contain in the test program. See "Summary of testing".RANNEX R (NORMATIVE)SOFTWARE EVALUATIONN/AThis test are not contain in the test program. See "Summary of testing".ANNEX EMFThe Tested product also complies to the requirements ofEN 50366:2003 A1 :2006This test are not contain in the test program. See "Summary of testing".TRF No. IECEN60335 2 73AN/A

Page 15 of 2311.8Report No. BE/303/2011TABLE: Heating test, thermocouplesPTest voltage (V) . :1,15·Pn Ambient ( C) . :25 Thermocouple locationsdT (K)Max. dT (K)GTX 300GTX 600GTX 900Internal wiring12141950External wiring (supply cord insulation)13141650Thermoplastic material404141-Outer surface of capacitor15161875Handle, knob, grip (shor period)12131360PCB40414112016.2TABLE: Leakage currentPSingle phase appliances: 1.06 x rated voltage .: 243,8V – GTX 600; GTX 900 254,4V – GTX 300 -Three phase appliances 1.06 x rated voltagedivided by 3: .:I (mA)Max. allowed I (mA)Live parts and accessible metal parts to metal foil which is incontact with accessible surface of insulating materialGTX 3000,010,75Live parts and metal partsGTX 3000,070,75Live parts and accessible metal parts to metal foil which is incontact with accessible surface of insulating materialGTX 6000,010,75Live parts and metal partsGTX 6000,080,75Live parts and accessible metal parts to metal foil which is incontact with accessible surface of insulating materialGTX 9000,010,75Live parts and metal partsGTX 9000,070,75Leakage current between16.3TABLE: Electric strengthPVoltage (V)Breakdown(Yes/No)Basic insulation1250NoReinforced insulation3000NoTest voltage applied between:TRF No. IECEN60335 2 73A

Page 16 of 23Report No. BE/303/2011Group/CENELEC Common Differences to IEC 60335-1:2001 (4. Edition)N/AThis test are not contain in the test program. See "Summary of testing".National DifferencesN/AThis test are not contain in the test program. See "Summary of testing".List of test equipment used:(Note: This is an example of the required attachment. Other forms with a different layout butcontaining similar information are also acceptable.)ClauseMeasurement /testingTesting / measuring equipment /material usedRange usedCalibrationdate11Digital power meter YOKOGAWA;type: WT-11011.201111Temperature measurement deviceALHBORN; type: THERM 3280-612.11.201116Multimeter PHILIPS; type: PM 271809.201116Leakage current measuring device;type: U-7108.12.201116High Voltage Test ApparatusGRABENHORST; type: H01.25TRF No. IECEN60335 2 73A12.2011

Page 17 of 23Photo documentationTRF No. IECEN60335 2 73AReport No. BE/303/2011

Page 18 of 23TRF No. IECEN60335 2 73AReport No. BE/303/2011

Page 19 of 23TRF No. IECEN60335 2 73AReport No. BE/303/2011

Page 20 of 23TRF No. IECEN60335 2 73AReport No. BE/303/2011

Page 21 of 23TRF No. IECEN60335 2 73AReport No. BE/303/2011

Page 22 of 23TRF No. IECEN60335 2 73AReport No. BE/303/2011

Page 23 of 23TRF No. IECEN60335 2 73AReport No. BE/303/2011

heater is first switched on; (IEC 60335-2-73) P – a statement that the immersion heater is to be installed only in a system where the heating element is always below water level, such as in a cistern-fed tank, if applicable (IEC 60335-2-73/A1) P 7

Related Documents:

Effective date: Apr 30, 2020 . IEC/EN 60335-1, IEC/EN 60335-2-2 CNS 3765, CNS 3765-2 100128 電熨斗 IEC/EN 60335-1, IEC/EN 60335-2-3 CNS 3765, CNS 3765-3 100129 旋轉式脫水機 IEC/EN 60335-1, IEC/EN 60335-2-4 CNS 3765-4, CNS 2926 sub-clause 3.3, 3.4 100130 洗碗機 IEC/EN 60335-1

Mar 26, 2019 · (IEC 60335-2-40:2018) Not a refrigerating system NA 5.101 Motor-compressor subjected to relevant test of clause 19 of IEC 60335-2-34, unless (IEC 60335-2-40:2018) Not a refrigerating system NA motor-compressor comply with that standard (IEC 60335-2-40:2018) Not a refrigerating

IEC 61215 IEC 61730 PV Modules Manufacturer IEC 62941 IEC 62093 IEC 62109 Solar TrackerIEC 62817 PV Modules PV inverters IEC 62548 or IEC/TS 62738 Applicable Standard IEC 62446-1 IEC 61724-1 IEC 61724-2 IEC 62548 or IEC/TS 62738 IEC 62548 or IEC/TS 62738 IEC 62548 or IEC/TS 62738 IEC 62548 or IEC/

(IEC 60335-2-30) N/A 5.3 Appliance used for tests of Cl. 19 also used for the test of Cl. 22.24 (IEC 60335-2-30) N/A Test of Cl. 22.24 carried out after test of Cl. 29 (IEC 60335-2-30) N/A 5.6 Thermostats short-circuited if sensible to room air temper

-A concerning IEC/EN 60335-2-29 (4th Edition) and IEC/EN 60335-1 (4th Edition) -B concerning IEC/EN 60335-1 (5th Edition) the two reports should be used together Based on the above information, the sample has been tested and found compliant with the requirement of the safety standards l

IEC/EN 62031 IEC/EN 62471 IEC 60598-1 ENEC IEC/EN 61347-2-13 (Relevant clauses) Relevant clauses of IEC/EN 60335-1 Annex BB of IEC/EN 60335-2-89 Annex CC of IEC/EN 60335-2-24 NSF UL 2108 CSA C22.2 No.9.0-96 Environmental RoHS/REACH Application IP rating No IP-rating, fit for use in

DIN EN 60335-1;VDE 0700-1:2020-08 AS/NZS 60335.1:2011 A1:2012 A2:2014 A3: 2015 A4:2017 A5:2019 IEC 60335-2-2:2009 A1:2012 A2:2016 EN 60335-2-2:2010 A11 A1:2013 DIN EN 60335-2-2:2014 A2:2015 VDE 0700-2: 2014 A1:2015 Household and similar electrical appliances – Safety – Part 2-2:

The Queen’s Awards for Enterprise are the UK’s most prestigious business awards, given only to companies or individuals who are outstanding in their field. Now in their 50th year, 2016 sees a high water mark of a total of 254 awards being presented: 150 for International Trade, 92 for Innovation, 7 for Sustainable Development and