Test Report issued under the responsibility of:Intertek Testing Services NA, Inc.TEST REPORTIEC 60335-2-40Safety of household and similar electrical appliancesPart 2-40: Particular requirements for electrical heat pumps, airconditioners and dehumidifiersReport Number. :103807635COL-001Date of issue . :26 March 2019Total number of pages . :145Name of Testing Laboratorypreparing the Report . :Intertek, ColumbusApplicant’s name . :Unico, IncAddress. :1120 Intagliata Dr.Arnold, MO, 63010, USTest specification:Standard . :IEC 60335-2-40:2018 in conjunction withIEC 60335-1:2010, AMD1:2013, AMD2:2016Test procedure. :Intertek Testing ProcedureNon-standard test method . :N/ATest Report Form No. . :IEC60335 2 40OTest Report Form(s) Originator . :VDE Testing and Certification InstituteMaster TRF . :Dated 2018-04-05General disclaimer:This report is for the exclusive use of Intertek’s Client and is provided pursuant to the agreement betweenIntertek and its Client. Intertek’s responsibility and liability are limited to the terms and conditions of theagreement. Intertek assumes no liability to any party, other than to the Client in accordance with theagreement, for any loss, expense or damage occasioned by the use of this report. Only the Client isauthorized to permit copying or distribution of this report and then only in its entirety. Any use of theIntertek name or one of its marks for the sale or advertisement of the tested material, product or servicemust first be approved in writing by Intertek.The observations and test results in this report are relevant only to the sample tested. This report by itselfdoes not imply that the material, product, or service is or has ever been under an Intertek certificationprogram.

Page 2 of 145103807635COL-001Test item description .:The product covered by this report is a EC motor/blower and controlmodule subassembly to be fitted into a larger assembly. Unit willbe factory wired in final assembly.Trade Mark .:UnicoManufacturer.:Unico, Inc.Model/Type reference .:U1218L-1EC (60Hz) or U1218L-1EC (50Hz)M2430B-EC (60Hz) or M2430B-EC (50Hz)M3036B-EC (60Hz) or M3036B-EC (50Hz)M3642B-EC (60Hz) or M3642B-EC (50Hz)M4860B-EC (60Hz) or M4860B-EC (50Hz)Ratings .:See Ratings Table 01Responsible Testing Laboratory (as applicable), testing procedure and testing location(s):CB Testing Laboratory:Testing location/ address . :Tested by (name, function, signature) . :Approved by (name, function, signature) . :Testing procedure: CTF Stage 1:Testing location/ address . : Intertek, 1717 Arlingate Lane, Columbus, OH 43228Tested by (name, function, signature) . : Andy Raines, EngineerApproved by (name, function, signature) . : That VoTesting procedure: CTF Stage 2:Testing location/ address . :Tested by (name signature) . :Witnessed by (name, function, signature) . :Approved by (name, function, signature) . :Testing procedure: CTF Stage 3:Testing procedure: CTF Stage 4:Testing location/ address . :Tested by (name, function, signature) . :Witnessed by (name, function, signature) . :Approved by (name, function, signature) . :Supervised by (name, function, signature) :TRF No. IEC60335 2 40O

Page 3 of 145103807635COL-001List of Attachments (including a total number of pages in each attachment):Attachment 1: Photos – 1 pageSummary of testing:Tests performed (name of test and testclause):Legibility Test – 7.14Current Input – 10.2Heating – 11Abnormal Operation – 19Mechanical Strength – 21.1Flexing Test – 23.3Clearance Reduction – 29.2Testing location:Intertek, 1717 Arlingate Lane, Columbus, OH 43228Summary of compliance with National Differences (List of countries addressed):NoneThe product fulfils the requirements of IEC 60335 2 40:2018 in conjunction withIEC 60335 1:2010, AMD1:2013, AMD2:2016TRF No. IEC60335 2 40O

Page 4 of 145103807635COL-001Copy of marking plate:The artwork below may be only a draft. The use of certification marks on a product must beauthorized by the respective NCBs that own these marks.TRF No. IEC60335 2 40O

Page 5 of 145103807635COL-001Test item particulars. : 1901A369401Classification of installation and use. : Stationary applianceSupply Connection . : Hardwire Pressure Terminals. :Possible test case verdicts:- test case does not apply to the test object .: NA- test object does meet the requirement.: P (Pass)- test object does not meet the requirement .: F (Fail)Testing .:Date of receipt of test item.: 3 March 2019Date (s) of performance of tests .:General remarks:"(See Enclosure #)" refers to additional information appended to the report."(See appended table)" refers to a table appended to the report.Throughout this report acomma /point is used as the decimal separator.Manufacturer’s Declaration per sub-clause 4.2.5 of IECEE 02:The application for obtaining a CB Test Certificateincludes more than one factory location and adeclaration from the Manufacturer stating that thesample(s) submitted for evaluation is (are)representative of the products from each factory hasbeen provided. :YesNot applicableWhen differences exist; they shall be identified in the General product information section.Name and address of factory (ies) . : Unico, Inc1120 Intagliata Dr.Arnold, MO, 63010, USGeneral product information:Horse PowerVoltsAmpsFrequencyPhaseCapacity (Btu/hr)TRF No. IEC60335 2 40OU1218½ HP120/240V6.2/3.9A50/60 Hz1Φ12000-18000M2430B½ HP120/240V6.2/3.9A50/60 Hz1Φ24000-30000M3036B1.0 HP120/240V11.5/6.9A50/60 Hz1Φ30000-36000M3642B1.0 HP120/240V11.5/6.9A50/60 Hz1Φ36000-42000M4860B1.0 HP120/240V11.5/6.9A50/60 Hz1Φ48000-60000

Page 6 of 145Report No. 103807635COL-001IEC 60335-2-40ClauseRequirement Test5GENERAL CONDITIONS FOR THE TESTSResult - RemarkTests performed according to clause 5, e.g. natureof supply, sequence of testing, etc.5.2VerdictPTests of clause 21 carried out on separatesamples. Tests of clauses 11, 19 and 21 requirepressure measurements made at various points inrefrigerating system (IEC 60335-2-40:2018)Not a refrigerating systemNAAt least one additional specially prepared samplerequired for tests of annex FF (Leak simulationtests) (IEC 60335-2-40:2018)Not a refrigerating systemNATemperatures on refrigerant piping measuredduring test of clause 11 (IEC 60335-2-40:2018)Not a refrigerating systemNAIf the tests of Annex LL are carried out, at leasttwo additional sensors are needed.(IEC 60335-2-40:2018)Not a refrigerating systemNAIf the test of Annex NN has to be carried out, anadditional appliance may be used.(IEC 60335-2-40:2018)Not a refrigerating systemNADue to the potentially hazardous nature of thetests of Clause 21 and Annexes EE and FF,special precautions need to be taken whencarrying out the tests. (IEC 60335-2-40:2018)Not a refrigerating systemNA5.6Appropriate controls rendered inoperative duringtest (IEC 60335-2-40:2018)Info5.7Tests of clauses 10 and 11 carried out under mostsevere operating conditions within operatingtemperature range specified by manufacturer.Annex AA provide examples of such temperatureconditions (IEC 60335-2-40:2018)Info5.10For split-package units, refrigerant lines installedin accordance with installation instructions(IEC 60335-2-40:2018)Not a refrigerating systemNALength of pipe is between 5 m and 7,5 m.(IEC 60335-2-40:2018)Not a refrigerating systemNAThermal insulation of refrigerant lines applied inaccordance with installation instructions(IEC 60335-2-40:2018)Not a refrigerating systemNAMotor-compressor subjected to relevant test ofclause 19 of IEC 60335-2-34, unless(IEC 60335-2-40:2018)Not a refrigerating systemNAmotor-compressor comply with that standard(IEC 60335-2-40:2018)Not a refrigerating systemNA5.102Motor-compressors tested and comply withIEC 60335-2-34 need not additionally tested forclause 21 (IEC 60335-2-40:2018)Not a refrigerating systemNA6CLASSIFICATION5.101TRF No. IEC60335 2 40O

Page 7 of 145Report No. 103807635COL-001IEC 60335-2-40ClauseRequirement TestResult - Remark6.1Protection against electric shock:Class I, II, III (IEC 60335-2-40:2018) . :Subassembly is Class I andhas Class II interconnectionand Isolation through ULRecognized transformer6.2Protection against harmful ingress of water, IP degree in accordance withIEC 60529 (IEC 60335-2-40:2018)- appliances or parts intended for outdoor use beat least IPX4 (IEC 60335-2-40:2018)VerdictPPNA- appliances intended only for indoor use(excluding laundry rooms) be IPX0(IEC 60335-2-40:2018)P- appliances intended to be used in laundry roomsbe at least IPX1 (IEC 60335-2-40:2018)NA6.101Degree of accessibility (accessible/not accessibleto the general public) (IEC 60335-2-40:2018)7MARKING AND INSTRUCTIONS7.1Rated voltage or voltage range (V) . :230/208VPSymbol for nature of supply including number ofphases, unless for single phase operation(IEC 60335-2-40:2018). :Single Phase – MarkedPRated frequency (Hz) . :50/60HzPRated power input (W), or . :Not markedPRated current (A) . :3.2 A – MarkedPManufacturer’s or responsible vendor’s name,trademark or identification mark . :UnicoPModel or type reference . :M2430BL1-EC3PSymbol IEC 60417-5172, for class II appliancesClass I subassemblyNAIP number, other than IPX0. :Ingress Protection Rating ofIPX0NASymbol IEC 60417-5180, for class III appliances,unlessClass INAthe appliance is operated by batteries only, orNo batteriesNAfor appliances powered by rechargeable batteriesrecharged in the applianceNo batteriesNASymbol IEC 60417-5018, for class II and class IIIappliances incorporating a functional earthNo functional earthNASymbol IEC 60417-5036, for the enclosure ofelectrically-operated water valves in externalhose-sets for connection of an appliance to thewater mains, if the working voltage exceedsextra-low voltageTRF No. IEC60335 2 40OCommercial gradeequipmentNot accessible to the generalpublicPPNA

Page 8 of 145Report No. 103807635COL-001IEC 60335-2-40ClauseRequirement TestResult - RemarkRefrigerant charge for each refrigerating system(IEC 60335-2-40:2018). :Not a refrigeration systemNARefrigerant number in accordance with ISO 817(IEC 60335-2-40:2018). :Not a refrigeration systemNAPermissible excessive operating pressure for thestorage tank (for sanitary hot water heat pumps);(IEC 60335-2-40:2018). :Not a refrigeration systemNAMaximum allowable pressure in the water and/orbrine circuit for the heat exchanger for hydronicfan coil units; (IEC 60335-2-40:2018) . :Not for use with a water orbrine circuitNAMaximum allowable pressure for the refrigerantcircuit; if the permissible excessive operatingpressure for the suction and discharge side differ,a separate indication is required;(IEC 60335-2-40:2018). :Not a refrigeration systemNAfor pre-charged pipe setsNot a refrigeration systemNA- refrigerant number in accordance with ISO817 (IEC 60335-2-40:2018)Not a refrigeration systemNA- the refrigerant charge in the line set(IEC 60335-2-40:2018)Not a refrigeration systemNA- maximum allowable pressure(IEC 60335-2-40:2018)Not a refrigeration systemNARatings in watts and voltage of a UV-C germicidallamp system if employed (IEC 60335-2-40:2018)No UV-C germicidal lampsNAAppliances are marked with all of the designationsand the rated inputs of the supplementary heatersfor which they are intended to be used, and haveprovision for identifying the actual heater that isfield installed. (IEC 60335-2-40:2018)No heatersNAMarking of direction of fluid flow(IEC 60335-2-40:2018)No fluidsNAFor appliances using flammable refrigerants, theflame symbol ISO 7010-W021 (2011-05) and theoperator’s manual symbol described in 7.6 bevisible when viewing the appliance after it hasbeen installed. (IEC 60335-2-40:2018)Not a refrigeration systemNAMarking may be behind a detachable part(IEC 60335-2-40:2018)No flammable refrigerantsNAPerpendicular height of the triangle used for thesymbol shall be at least 30 mm.(IEC 60335-2-40:2018)No flammable refrigerantsNAFor appliances that are not single packaged units,the required markings be provided on all indoorand outdoor units which complete the refrigeratingsystem when installed. (IEC 60335-2-40:2018)No flammable refrigerantsNATRF No. IEC60335 2 40OVerdict

Page 9 of 145Report No. 103807635COL-001IEC 60335-2-40ClauseRequirement TestResult - RemarkWhen an A2L refrigerant is used, the flamesymbol ISO 7010-W021 (2011-05) be replacedwith the A2L symbol described in 7.6.(IEC 60335-2-40:2018)No flammable refrigerantsNAIf a flammable refrigerant is used, the symbols for“read operator’s manual”, “operator’s manual;operating instructions” and “service indicator; readtechnical manual” (symbols ISO 7000-0790 (200401) and ISO 7000-1659 (2004-01)) includingcolour and format be placed on the appliance in alocation visible to the persons required to knowthe information. The perpendicular height of thesymbol be at least 10 mm. (IEC 60335-2-40:2018)No flammable refrigerantsNAIf a flammable refrigerant is used, an additionalwarning symbol (flame symbol: ISO 7010-W021(2011-05)) be placed on the nameplate of the unitnear declaration of refrigerant type and chargeinformation. Perpendicular height of the symbol beat least 10 mm, and symbol need not be in colour(IEC 60335-2-40:2018)No flammable refrigerantsNAWhen an A2L refrigerant is used, the flamesymbol ISO 7010-W021 (2011-05) be replacedwith the A2L symbol described in 7.6.(IEC 60335-2-40:2018)No flammable refrigerantsNAFollowing warning also be applied to the non-fixedappliance when a flammable refrigerant isemployed. The warning be placed on the outsideof the appliance such that it is visible when inservice for non-fixed appliance.WARNINGAppliance shall be installed, operated and storedin a room with a floor area larger than ‘X’ m².(IEC 60335-2-40:2018)No flammable refrigerantsNAMinimum room size X be specified on theappliance. The X in the marking be determined inm2 according to Annex GG; the marking not berequired if the refrigerant charge (mc) of theappliance is up to m1 according to GG.1.2.Not for use with refrigerantNAIf not already visible when accessing service portand if service port provided, service port markedto identify type of refrigerant. If refrigerant isflammable, symbol B.3.2 of ISO 3864, beincluded, without specifying the colour. When anA2L refrigerant is used, the flame symbol ISO7010-W021 (2011-05) be replaced with the A2Lsymbol described in 7.6. (IEC 60335-2-40:2018)Not for use with refrigerantNAAppliances employing refrigerating systems withmaximum allowable pressures than 7 MPa bemarked with symbol ISO 7000-1701 (2004-01)followed by the text “(X) MPa” and the Operator’smanual; operating instructions symbol ISO 70001641 (2004-01). (IEC 60335-2-40:2018)Not for use with refrigerantNATRF No. IEC60335 2 40OVerdict

Page 10 of 145Report No. 103807635COL-001IEC 60335-2-40Clause7.27.3Requirement TestResult - RemarkWhere: “X” is not less than the maximumallowable pressure as determined in Annex EE.(IEC 60335-2-40:2018)Not for use with refrigerantNAWarning for stationary appliances for multiplesupplyOnly one supplyNAWarning placed in vicinity of terminal coverOnly one supplyNARange of rated values marked with the lower andupper limits separated by a hyphenDifferent rated values marked with the valuesseparated by an oblique stroke7.47.57.6VerdictNA230/208VPAppliances adjustable for different rated voltagesor rated frequencies, the voltage or the frequencysetting is clearly discernibleNARequirement met if frequent changes are notrequired and the rated voltage or rated frequencyto which the appliance is to be adjusted isdetermined from a wiring diagramNAAppliances with more than one rated voltage orone or more rated voltage ranges, marked withrated input or rated current for each rated voltageor range, unlessOnly one rated current thatapplies for both ratedvoltages.the power input or current are related to thearithmetic mean value of the rated voltage rangeOnly one current ratingNARelation between marking for upper and lowerlimits of rated power input or rated current andvoltage is clearInput is the same at eithervoltageNACorrect symbols usedSymbols not usedNASymbol ISO 7010-W021 (2011-05)(IEC 60335-2-40:2018)Symbols not usedNASymbol ISO 7000-1659 (2004-01)(IEC 60335-2-40:2018)Symbols not usedNAA2L symbol (IEC 60335-2-40:2018)Symbols not usedNASymbol ISO 7000-1701 (2004-01)(IEC 60335-2-40:2018)Symbols not usedNASymbol IEC 60417-6040 (2010-08)(IEC 60335-2-40:2018)Symbols not usedNASymbol ISO 7000-1641 (2004-01)(IEC 60335-2-40:2018)Symbols not usedNASymbol for nature of supply placed next to ratedvoltageMarking providedPSymbol for class II appliances placed unlikely tobe confused with other markingClass I applianceNAUnits of physical quantities and their symbolsaccording to international standardized systemPhysical quantities givenTRF No. IEC60335 2 40OPP

Page 11 of 145Report No. 103807635COL-001IEC 60335-2-40ClauseRequirement TestResult - Remark7.7Connection diagram fixed to appliances to beconnected to more than two supply conductorsand appliances for multiple supply, unlessSingle supply connection (2conductors only)NAcorrect mode of connection is obviousNot applicable (See above)NA7.8VerdictExcept for type Z attachment, terminals for connection to the supply mainsindicated as follows:P- marking of terminals exclusively for the neutralconductor (letter N)Marking providedP- marking of protective earthing terminals (symbolIEC 60417-5019)Marking providedP- marking of functional earthing terminals (symbolIEC 60417-5018)No functional earthing- marking not placed on removable partsNAP7.9Marking or placing of switches which may cause ahazardSwitches are inside of theSMART control boxP7.10Indications of switches on stationary appliancesand controls on all appliances by use of figures,letters or other visual means . :Switches are marked withlettersPThis applies also to switches which are part of acontrolSwitches are marked withlettersPIf figures are used, the off position indicated by thefigure 0Off position marked with “0”PThe figure 0 indicates only OFF position, unlessno confusion with the OFF position“0” does not indicate anyposition but “off”P7.11Indication for direction of adjustment of controlsNo integral controls7.12Instructions for safe use providedInstructions area provided inOWNER’S MANUAL, but notthe blower module manual.PDetails concerning precautions during usermaintenanceInstructions provided inOWNER’S MANUAL, but notthe blower module manual.PAppliances not accessible to general public,classification of clause 6.101 included(IEC 60335-2-40:2018)Classification is providedPAppliances using flammable refrigerants, aninstallation, service and operation manual, eitherseparate or combined manuals, provided andinclude information given in annex DD(IEC 60335-2-40:2018)No refrigerants usedNANAThe instructions state that:- the appliance is not to be used by persons(including children) with reduced physical, sensoryor mental capabilities, or lack of experience andknowledge, unless they have been givensupervision or instructionTRF No. IEC60335 2 40OInstruction is providedP

Page 12 of 145Report No. 103807635COL-001IEC 60335-2-40Clause7.12.1Requirement TestResult - Remark- children being supervised not to play with theapplianceInstruction providedFor a part of class III construction supplied from adetachable power supply unit, the instructionsstate that the appliance is only to be used with theunit providedNo parts of class IIIconstruction supplied fromdetachable power supplyNAInstructions for class III appliances state that itmust only be supplied at SELV, unlessNot a class III applianceNAit is a battery-operated appliance, the batterybeing charged outside the applianceNot battery operatedNAFor appliances for altitudes exceeding 2000 m, themaximum altitude is stated. :Does not exceed 2000 mNAThe instructions for appliances incorporating afunctional earth states that the applianceincorporates an earth connection for functionalpurposes onlyEarth is protective, notfunctionalNASufficient details for installation suppliedVerdictPPFor an appliance intended to be permanentlyconnected to the water mains and not connectedby a hose-set, this is statedNot connected to watermainsNAIf different rated voltages or different ratedfrequencies are marked, the instructions statewhat action to be taken to adjust the applianceNo action neededNASufficient details for installation or maintenance supplied (IEC 60335-2-40:2018):- that the appliance shall be installed inaccordance with national wiring regulations(IEC 60335-2-40:2018)Instruction is providedP- the dimensions of the space necessary forcorrect installation of the appliance including theminimum permissible distance to adjacentstructures (IEC 60335-2-40:2018)Dimensional Data given in MSERIES BLOWER MODULEsheetP- for appliances with supplementary heaters, theminimum clearance from the appliance tocombustible surfaces (IEC 60335-2-40:2018)No supplementary heatersNA- a wiring diagram with a clear indication of theconnections and wiring to external control devicesand supply cord (IEC 60335-2-40:2018)Provided in S.M.A.R.T.CONTROL BOARD (SCB)INSTALLATIONINSTRUCTIONSP- the range of external static pressures at whichthe appliance was tested (add-on heat pumps andappliances with supplementary heaters only)(IEC 60335-2-40:2018)Not a heat pump or for usew/ supplementary heatersNA- the method of connection to the appliance to theelectrical supply and interconnection of separatecomponents (IEC 60335-2-40:2018)Given in S.M.A.R.T.CONTROL BOARD (SCB)INSTALLATIONINSTRUCTIONSFTRF No. IEC60335 2 40O

Page 13 of 145Report No. 103807635COL-001IEC 60335-2-40ClauseRequirement TestResult - Remark- indication of which parts of the appliance aresuitable for outdoor use, if applicable(IEC 60335-2-40:2018)For indoor use onlyNA- details of type and rating of fuses , or rating ofcircuit breakers; (IEC 60335-2-40:2018)2A mini blade fuseP- details of supplementary heating elements thatmay be used in conjunction with the appliance,including fitting instructions either with theappliance or with the supplementary heater(IEC 60335-2-40:2018)No such elementsP- maximum and minimum water or brine operatingtemperatures (IEC 60335-2-40:2018)Not for use with water orbrineNA- maximum and minimum water or brine operatingpressures (IEC 60335-2-40:2018)Not for use with water orbrineNA- instructions on charging of refrigerants whenaddition of charge is required by the manufacturerfor completing the refrigerating system.(IEC 60335-2-40:2018)Not for use with refrigerantsNAOpen storage tanks of heat pumps for waterheating, accompanied by an instruction sheetwhich state that the vent shall not be obstructed(IEC 60335-2-40:2018)No such componentsNA7.12.2Stationary appliances not fitted with means fordisconnection from the supply mains having acontact separation in all poles that provide fulldisconnection under overvoltage category III, theinstructions state that means for disconnectionmust be incorporated in the fixed wiring inaccordance with the wiring rulesOvervoltage cat IINA7.12.3Insulation of the fixed wiring in contact with partsexceeding 50 K during clause 11; instructionsstate that the fixed wiring must be protectedNo components have a temprise of greater than 50 KNA7.12.4Instructions for built-in appliances:7.12.5VerdictNA- dimensions of spaceNot a built-in applianceNA- dimensions and position of supporting and fixingNot a built-in applianceNA- minimum distances between parts andsurrounding structureNot a built-in applianceNA- minimum dimensions of ventilating openings andarrangementNot a built-in applianceNA- connection to supply mains and interconnectionof separate componentsNot a built-in applianceNA- allow disconnection of the appliance afterinstallation, by accessible plug or a switch in thefixed wiring, unlessNot a built-in applianceNAa switch complying with 24.3Not a built-in applianceNAReplacement cord instructions, type X attachmentwith a specially prepared cordNo cord providedNATRF No. IEC60335 2 40O

Page 14 of 145Report No. 103807635COL-001IEC 60335-2-40ClauseRequirement TestResult - RemarkReplacement cord instructions, type Y attachmentNo cord providedNAReplacement cord instructions, type Z attachmentNo cord providedNA7.12.6Caution in the instructions for appliancesincorporating a non-self-resetting thermal cut-outthat is reset by disconnection of the supply mains,if this cut-out is required to comply with thestandardNo heatingNA7.12.7Instructions for fixed appliances stating how theappliance is to be fixedInstructions given inINSTALLATION MANUALFOR ‘M’ SERIES MODULARAIR HANDLER UNITS, butnot the blower moduleinstructions7.12.8Instructions for appliances connected to the water mains:NA- max. inlet water pressure (Pa) . :Not connected to watermainsNA- min. inlet water pressure, if necessary (Pa) . :Not connected to watermainsNAInstructions concerning new and old hose-sets forappliances connected to the water mains bydetachable hose-setsNot connected to watermainsNAInstructions specified in 7.12 and from 7.12.1 to7.12.8 appear together before any otherinstructions supplied with the applianceInstructions appear at thefront of the manualThese instructions may be supplied with theappliance separately from any functional usebookletInfoNAThey may follow the description of the appliancethat identifies parts, or follow thedrawings/sketchesInfoNAIn addition, instructions are also available in analternative format such as on a website or onrequest from the user in a format such as a DVDInfoNA7.12.9VerdictPPIn addition, instructions are also available in analternative format such as on a website or in aformat such as a DVD . :P7.13Instructions and other texts in an official languageP7.14Markings clearly legible and durable:Signal words WARNING, CAUTION, DANGER inuppercase having a height as specified . :7.6 mm tall minimumPUppercase letter of the text explaining the signalword not smaller than 1,6 mm . :2.3 mm tall minimumPMoulded in, engraved, or stamped markings eitherraised above or have a depth below the surface ofat least 0,25 mm, unlessNot applicable per belowcontrasting colours are usedContrasting colours are usedTRF No. IEC60335 2 40ONAP

Page 15 of 145Report No. 103807635COL-001IEC 60335-2-40ClauseRequirement TestResult - RemarkMarkings checked by inspection, measurementand rubbing test as specifiedTested on 4-Feb-2019.Marking is clear after testingPMarkings on a main partMarkings are on a main partPMarking clearly discernible from the outside, ifnecessary after removal of a coverMarking are clearlydiscernible from the outsidePFor portable appliances, cover can be removed oropened without a toolFixed applianceFor stationary appliances, name, trademark oridentification mark and model or type referencevisible after installationVisible after installationPFor fixed appliances, name, trademark oridentification mark and model or type referencevisible after installation according to theinstructionsVisible after installationPIndications for switches and controls placed on ornear the components. Marking not on parts whichcan be positioned or repositioned in such a waythat the marking is misleadingSwitches are in SMARTController, and are marked inclose proximity to thecomponentsPThe symbol IEC 60417-5018 placed next to thesymbol IEC 60417-5172 or IEC 60417-5180Not a class II or class IIIapplianceNAMarking on panel allowed, provided panel in placefor intended operation of appliance(IEC 60335-2-40:2018)No such markingNA7.16Marking of a possible replaceable thermal link orfuse link clearly visible with regard to replacing thelinkNo such linkNA7.101Marking of fuses and overload protective devices, if replaceable(IEC 60335-2-40:2018):NA- fuse rated current in amperes, type and ratedvoltage or (IEC 60335-2-40:2018)Only fuse is a low-voltageblade fuse.NA- manufacturer and model of overload protectivedevice (IEC 60335-2-40:2018)No resettable overloaddevicesNA7.102Marking for connection with aluminium wire, ifnecessary (IEC 60335-2-40:2018)Not intended to beconnected via aluminiumwiresNA7.103For appliances made up of more than one factorymade assembly specified by the manufacturer tobe used together, instructions shall be provided forcompleting the assembly to ensure compliancewith the requirements. (IEC 60335-2-40:2018)Instructions give in SMARTCo

Mar 26, 2019 · (IEC 60335-2-40:2018) Not a refrigerating system NA 5.101 Motor-compressor subjected to relevant test of clause 19 of IEC 60335-2-34, unless (IEC 60335-2-40:2018) Not a refrigerating system NA motor-compressor comply with that standard (IEC 60335-2-40:2018) Not a refrigerating

Related Documents:

Effective date: Apr 30, 2020 . IEC/EN 60335-1, IEC/EN 60335-2-2 CNS 3765, CNS 3765-2 100128 電熨斗 IEC/EN 60335-1, IEC/EN 60335-2-3 CNS 3765, CNS 3765-3 100129 旋轉式脫水機 IEC/EN 60335-1, IEC/EN 60335-2-4 CNS 3765-4, CNS 2926 sub-clause 3.3, 3.4 100130 洗碗機 IEC/EN 60335-1

IEC 61215 IEC 61730 PV Modules Manufacturer IEC 62941 IEC 62093 IEC 62109 Solar TrackerIEC 62817 PV Modules PV inverters IEC 62548 or IEC/TS 62738 Applicable Standard IEC 62446-1 IEC 61724-1 IEC 61724-2 IEC 62548 or IEC/TS 62738 IEC 62548 or IEC/TS 62738 IEC 62548 or IEC/TS 62738 IEC 62548 or IEC/

-A concerning IEC/EN 60335-2-29 (4th Edition) and IEC/EN 60335-1 (4th Edition) -B concerning IEC/EN 60335-1 (5th Edition) the two reports should be used together Based on the above information, the sample has been tested and found compliant with the requirement of the safety standards l

(IEC 60335-2-30) N/A 5.3 Appliance used for tests of Cl. 19 also used for the test of Cl. 22.24 (IEC 60335-2-30) N/A Test of Cl. 22.24 carried out after test of Cl. 29 (IEC 60335-2-30) N/A 5.6 Thermostats short-circuited if sensible to room air temper

DIN EN 60335-1;VDE 0700-1:2020-08 AS/NZS 60335.1:2011 A1:2012 A2:2014 A3: 2015 A4:2017 A5:2019 IEC 60335-2-2:2009 A1:2012 A2:2016 EN 60335-2-2:2010 A11 A1:2013 DIN EN 60335-2-2:2014 A2:2015 VDE 0700-2: 2014 A1:2015 Household and similar electrical appliances – Safety – Part 2-2:

IEC/EN 62031 IEC/EN 62471 IEC 60598-1 ENEC IEC/EN 61347-2-13 (Relevant clauses) Relevant clauses of IEC/EN 60335-1 Annex BB of IEC/EN 60335-2-89 Annex CC of IEC/EN 60335-2-24 NSF UL 2108 CSA C22.2 No.9.0-96 Environmental RoHS/REACH Application IP rating No IP-rating, fit for use in

IEC has formed IECRE for Renewable Energy System verification - Component quality (IEC 61215, IEC 61730, IEC 62891, IEC 62109, IEC 62093, IEC 61439, IEC 60947, IEC 60269, new?) - System: - Design (IEC TS 62548, IEC 60364-7-712, IEC 61634-9-1, IEC 62738) - Installation (IEC 62548, IEC 60364-7-712)

A Short Introduction to Computer Programming Using Python Carsten Fuhs and David Weston (based on earlier documents by Sergio Gutierrez-Santos, Keith Mannock, and Roger Mitton) Birkbeck, University of London v1.4 This document forms part of the pre-course reading for several MSc courses at Birkbeck. (Last revision: December 4, 2019.) Important note: If anything is unclear, or you have any sort .