—CANADIAN BROCHURE UL489 / CSA C22.2 No.5 devicesUL1077 / CSA C22.2 No. 235 devicesFast selection of devicesEasy codification of devices—Miniature Circuit BreakersQuick Selection GuideMiniature Circuit BreakerQuick Selection Guide

—We didn’t just change the market, we created itABB miniature circuit breakers, 90 years of trustThenIn 1923, Hugo Stotz combined a thermal andmagnetic trip unit in a single device that could bescrewed into regular fuse sockets. Stotz’s inventionopened a new world in electrical installation.NowThe next-generation ABB mini circuit breakers(MCBs) provide the highest safety solutions fornearly every electrical application and installationtype—and meet all relevant standards worldwide.System pro M compact MCBsMiniature circuit breakers protect installationsagainst overload and short circuit to ensure reliabilityand safety for operations. They are selectivelyswitchable, even under load, in the event of a faultor for maintenance purposes. Downtime is minimized,thanks to the devices’ reclosing capability. Residential, commercial and industrialmulti-functional platform, completely compatiblefor maximum value and flexibility Comprehensive, fully integrated range ofeasy-to-install MCBs and accessories

—Quality and sustainabilityOur MCBs are built to last. We achieve this through an uncompromisingcommitment to quality. We use only the finest components andmaterials. All materials comply with EU (RoHS, REACH) standards forsustainability and are halogen-free. Every unit is inspected three timesbefore it leaves our facilities.Our reputation for innovation, quality and performance is built into every ABB circuit breaker with thesepatented features:TerminalExtended size with insulation for IP20 protectionand new pressure plate for improved conductorconnection — easier to handle, safer to useContact designWith snap-action mechanism for improvedarc movement and optimized switchingSwitching mechanismNew design and assembly increases reliabilityof triggering — even under tough conditionsTripping deviceOptimized arc extinguishing systemimproves safetyPatented twin terminalswith captive screws addcomfort and safetySimple switch mechanismprovides immediate systemavailability after a faultProduct code identifiesbasic technical specsLaser printing resistsscratches and solventsPatented trippingdevice ensuresuncompromised safetyContact-position indicatorwith direct contactconnection clearly indicatesposition for extra safetyUnit performs at its highrated voltagePatented housing design offers environmentalfriendliness and optimized performance

—CSA C22.2 No.235 / UL1077Supplementary ProtectionStandardsType of load / applicationSuggestedtrip curveNetworktypeACCable protectionBDCACMedium magnetic start-upcurrent protectionCDCUL1077CSA C22.2 No.235ACHigh inductive systems, Highin-rush demand applicationsDDCACHigh magnetic start-upprotection (motors, transformers)KDCACSemiconductors and sensitiveZequipment protectionDCAvailable voltagelevelAvailable current levelsInterruptingcapacitySeries suggested480Y/277 Vac0,5.63 A10 kA / 5 kA (1)ST200M480Y/277 Vac10.100 A10 kAS800C (2)600Y/347 Vac10.63 A6 kAS800S (2)60 Vdc / 125 Vdc6.63 A10 kAST200M125 Vdc / 500 Vdc10.100 A10 kAS800C (2)480Y/277 Vac0,5.63 A10 kA / 5 kA (1)ST200M480Y/277 Vac10.100 A10 kAS800C (2)600Y/347 Vac10.100 A6 kAS800S (2)600Y/347Vac10.32 A15 kAS800HV (3p only) (2)60 Vdc / 125 Vdc0,5.63 A10 kAST200M125 Vdc / 500 Vdc10.100 A10kAS800C (2)250 Vdc / 500 Vdc0.5.63 A10 kAS200MUC (2)480Y/277 Vac0,5.63 A10 kA / 5 kA (1)ST200M480Y/277 Vac10.100 A10 kAS800C (2)600Y/347 Vac10.63 A6 kAS800S (2)60 Vdc / 125 Vdc0,5.63 A10 kAST200M125 Vdc / 500 Vdc10.100 A10 kA480Y/277 Vac0,5.63 A10 kA / 5 kA480Y/277 Vac10.100 A10 kAS800C (2)600Y/347 Vac10.63 A6 kAS800S (2)600Y/347 Vac10.32 A15 kAS800HV (3p only) (2)60 Vdc / 125 Vdc0,5.63 A10 kAST200M125 Vdc / 500 Vdc10.100 A10 kAS800C (2)250 Vdc / 500 Vdc0,2.63 A10 kA480Y/277 Vac0,5.63 A10 kA / 5 kA60 Vdc / 125 Vdc0,5.63 A10 kAST200M250 Vdc / 500 Vdc0,5.63 A10 kAS200MUC (2)(1) ST200M series certifies 10 kA up to 35A max at 480Y/277Vac and up to 63A at 240Vac(2) Non-stock itemsS800C (2)ST200M, S200MR(3)(1)S200MUC (2)ST200M(1)(3) Ring terminal version—Part number configurationST201M-K ** NAS801C-K **S201MUC-K **Neutral pole:NA: With neutral poleAmperage:Amperage:Trip curve type:Trip curve type:B, C, D, K, ZB, C, D, K, ZMCB typeAmperage:Refer to code tableRefer to code tableMCB typeRefer to code tableTrip curve type:B, C, D, K, ZMCB typePoles:Poles:Poles:1, 2, 3, 41, 2, 3, 41, 2, 3, 4

—CSA C22.2 No.5 / UL489Branch Circuit ProtectionStandardsType of load / applicationSuggestedtrip curveMedium magnetic start-upcurrent protectionCNetworktypeACDCHigh magnetic start-upUL489tectionCSA C22.2 No.5(motors, transformers)ACproKDCSemiconductors andsensitive equipmentprotectionACZDCUL489BAvailable voltagelevelAvailable currentlevelsInterruptingSeries suggestedcapacity240 Vac0.5.63 A10 kASU200M480Y/277 Vac0.5.40 A10 kASU200M48 Vdc / 96 Vdc0.5.63 A10 kASU200M240 Vac0.2.63 A10 kASU200M, SU200MR (1, 2)240 Vac10.100 A30 kA / 50 kA S800U480Y/277 Vac0.2.35 A10 kASU200M, SU200MR (1, 2)60 Vdc / 125 Vdc1.63 A14 kAS200UDC48 Vdc / 96 Vdc0.2.63 A10 kASU200M240 Vac0.5.63 A10 kASU200M240 Vac10.100 A30 kA / 50 kA S800U (2)480Y/277 Vac0.5.40 A10 kASU200M60 Vdc / 125 Vdc1.63 A14 kAS200UDC48 Vdc / 96 Vdc0.5.63 A10 kASU200MSemiconductors and sensitiveequipment protection in PVapplicationsZDC600 Vdc10.80A10 kAS800U-UCZ (2)GFDI in PV applicationsPV-SDC1000 Vdc5A3 kAS800U-PVS (2)(1) Ring terminal version(2) Non-stock items—Part number configurationSU201M-K **S201UDC-K **S801U-K **Amperage:Amperage:Refer to code tableRefer to code tableAmperage:Refer to code tableTrip curve type:Trip curve type:Trip curve type:C, K, ZK, ZK, Z, UCZ, PVSPoles:Poles:Poles:1, 2, 3, 41, 2, 3, 41, 2, 3 (S800U only)4 (S800U, UCZ and PVS)

—Amperage code tableAvailable CurrentUL489 / CSA C22.2 No.5 / UL489BSU200MSU200MRS200UDCS800UUL1077 / CSA 22.2 e0.20.2 A 0.30.3 A 0.50.5 A0.750.75 A11A 1.61.6 A 22A 33A 44A 55A 66A 77A 88A 1010 A 1313 A 1515 A 1616 A 2020 A 2525 A 3030 A 3232 A 3535 A 4040 A 5050 A 6060 A 6363 A 7070 A 8080 A 9090 A 100100 A C K Z KKZKZ B C D K Z K CCDKCK K ZS800HVB S800SS800CS200MUCAmperagecode

—Trip curve informationTrip curves are an essential part of the System pro M compact miniature circuit breakeroffering. Manufacturing tolerance of the short circuit tripping function allows aminiature circuit breaker to be selected according to the application. When selectinga trip curve for the application, load type and inrush current are driving factors in theselection process. System pro M compact circuit breakers offer up to five trip curvesto meet varying applications.UL 489Z Curve 2 x I n ITripp 3 x I n (AC) 3 x I n ITripp 4.5 x I n (DC, SU 200 M) 3 x I n ITripp 6 x I n (DC, S 200 UDC)C Curve 5 x I n ITripp 10 x I n (AC) 7 x I n ITripp 15 x I n (DC, SU 200 M)K Curve 10 x I n ITripp 14 x I n (AC) 14 x I n ITripp 21 x I n (DC, SU 200 M) 14 x I n ITripp 25 x I n (DC, S 200 UDC)UL 1077Z Curve 2 x I n ITripp 3 x I n (AC) 2 x I n ITripp 4.5 x I n (DC)Typical loads by trip curveZ Curve Designed to protect circuits that need a very lowshort circuit trip setting Ex: SemiconductorsB Curve Designed for cable protection Ex: Control circuits, lightingC Curve Designed for medium magnetic startups Ex: Lighting panels, control panelsD and K Curves Designed to allow for high inrush loads Ex: Motor or transformation circuits1206040Minutes Below is a visual summary of the trip curves (perstandard) and typical load types, along with thetripping range as compared to the nominal current.The graph at the bottom right provides a visualsummary of the trip curves.201062140B Curve 3 x I n ITripp 5 x I n (AC) 4 x I n ITripp 7 x I n (DC)D Curve 10 x I n ITripp 20 x I n (AC) 10 x I n ITripp 21 x I n (DC)64Seconds C Curve 5 x I n ITripp 10 x I n (AC) 7 x I n ITripp 15 x I n (DC)2020.2D ——— K 0.021K Curve 10 x I n ITripp 14 x I n (AC) 10 x I n ITripp 22.4 x I n (DC)C B Z 0.11.523510Multiple of rated current 2030

—ABB - Campus Montréal.800 Hymus BoulevardSaint-Laurent, Quebec, CanadaH4S 0B5Phone: 438-843-6000Toll Free: 1-888-856-6266www.abb.com/lowvoltageWe reserve all rights in this document and inthe subject matter and illustrations containedtherein. Any reproduction, disclosure to thirdparties or utilization of its contents - in wholeor in parts - is forbidden without prior writtenconsent of ABB Inc. Copyright 2019 ABB. All rights reserved.1SXP403003B0202, January 2019—We reserve the right to make technicalchanges or modify the contents of thisdocument without prior notice. With regardto purchase orders and/or contracts, theagreed particulars shall prevail. ABB Inc.does not accept any responsibility whatsoever for potential errors or possible lackof information in this document.

Trip curves are an essential part of the System pro M compact miniature circuit breaker offering. Manufacturing tolerance of the short circuit tripping function allows a miniature circuit breaker to be selected according to the application. When selecting a trip curve for the application, load type and inrush current are driving factors in the

Related Documents:

ABB Control SECRL - 1 2001-06-19 A New Contactor Range from ABB New Generation ABB Contactors. ABB Control SECRL - 2 2001-06-19 The ABB range of A The ABB range of A contactorscontactors A 9, A 12, A 16 A 26, A 30, A 40 A 50, A 63, A 75 A 95, A

ABB - global market and technology leader in AC drives ABB (www.abb.com) is a leader in power and automation technologies that enable utility and industry customers to improve their performance while lowering environmental impact. ABB is the world's largest drives manufacturer. The ABB Group of companies operates in around 100 countries

values quoted in the Coil voltage selection table Coil consumption at Uc max. q 20 C: 9 W pull-in/holding Replacement coils: consult us (standard coils used on NL control relays are not suitable for TNL control relays). Pos.1 A B Pos. 3, 4 ABB ABB ABB ABB A B Ambient temp. Max. switching frequency mm mm C Operating cycles/h

E-bypass. The ABB E-Clipse Bypass has taken these developments to the next level. In addition to the benefits of the previous ABB design, ABB has added new capabilities focused upon the changing and evolving customer and market requirements. This brochure will give the user a brief overview

In 1994, ABB pioneered serial communications for VFDs in the HVAC industry. Today ABB has installed over 150,000 units (in the U.S. alone) connected to building automations systems using the various HVAC communications protocols. The ABB E-Clipse Bypass includes serial communications in the bypass mode. Now, going to bypass does not mean losing

ABB High Voltage Products Surge arresters 3 Surge arrester from ABB Switzerland in Wettingen ABB Switzerland Ltd. produces surge arresters for all applications. This product overview makes it easy to choose the right arrester. We have created a selection table for each of our product groups. In the left hand column of the selection table you will

ABB Instrument Transformers — Buyer’s Guide Edition 5, 2008-03 A-2 Introduction Day after day, all year around— with ABB Instrument Transformers ABB has been producing instrument trans-formers for more than 60 years. Thousands of our products perform vital functions in electric powe

ABB Turbocharging Type VTR201-2 HT845577 nMmax 0 t Mmax 650 nBmax 0 t Bmax 0 1/s C 00250 12 100 100 Year 2020 . ABB Turbo Systems Ltd ABB. . Design and specifications are subject to change without notice. Printed on naturally white paper, bleached free from chlorine and environmentally acceptable. .