Manual Aeotec Siren Gen5

2y ago
126 Views
2 Downloads
1.03 MB
5 Pages
Last View : 17d ago
Last Download : 3m ago
Upload by : Bria Koontz
Transcription

29-09-2020 15:51AeotecSiren Gen5SKU: AEO DSD31QuickstartThis is a secure Siren for Europe. To run this device please connect it to your mains power supply. Turn the primary controller of Z-Wave network into inclusionmode, short press the products Action button that you can find on the product"s housing.Important safety informationPlease read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer,distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use thisequipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.What is Z-Wave?Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) andevery mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is notin direct wireless range of the transmitter.This device and every other certified Z-Wave device can be used together with any other certified Z-Wavedevice regardless of brand and origin as long as both are suited for the same frequency range.If a device supports secure communication it will communicate with other devices secure as long as thisdevice provides the same or a higher level of security. Otherwise it will automatically turn into a lower level ofsecurity to maintain backward compatibility.For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.Product DescriptionAeon Labs Siren Gen5 is a siren Z-Wave device that when an emergency is happening it lets you know. Its 105dB Speaker System is always heard. Its super-brightLED system lights your path even when it is dark. Siren provides a smart home with the perfect security and safety features that it needs.Those security and safety features are matched by smart features. Sirens speaker system can access 5 different audio alerts, allowing your smart home to pick thealert best suited to the emergency. The speaker systems volume can also be adjusted so that Siren is perfect for every space in every home.Prepare for Installation / ResetPlease read the user manual before installing the product.In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do thisby performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to usethe primary controller of the previous network to make sure the very device is excluded properly from this network.Reset to factory defaultThis device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.Press and hold the Action button that you can find on the product"s housing for 20 seconds and then release. This procedure should only be used when the primarycontroller is inoperable.Safety Warning for Mains Powered DevicesATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to theassembly of the product, the voltage network has to be switched off and ensured against re-switching.InstallationPlug the device into a suitable wall g en&sku AEO DSD31Pagina 1 van 5

29-09-2020 15:51Inclusion/ExclusionOn factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with thedevices of this network. This process is called Inclusion.Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. Thiscontroller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.Inclusion1. Connect the device according to the instructions2. Press the button at the bottom of the Siren Gen5 onceExclusion1. Press the button at the bottom of the Siren Gen5 onceCommunication to a Sleeping device (Wakeup)This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In order tocommunicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and storecommands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time issignificantly decreased.This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox.Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static controller thiscontroller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses of thedevice. To wakeup the device please perform the following action: N/AQuick trouble shootingHere are a few hints for network installation if things dont work as expected.1.2.3.4.5.6.Make sure a device is in factory reset state before including. In doubt exclude before include.If inclusion still fails, check if both devices use the same frequency.Remove all dead devices from associations. Otherwise you will see severe delays.Never use sleeping battery devices without a central controller.Dont poll FLIRS devices.Make sure to have enough mains powered device to benefit from the meshingAssociation - one device controls an other deviceZ-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a differentdevice, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are alwaysrelated to certain events (e.g. button pressed, sensor triggers, .). In case the event happens all devices stored in the respective association group will receive thesame wireless command wireless command, typically a 'Basic Set' Command.Association g en&sku AEO DSD31Pagina 2 van 5

29-09-2020 15:51Group NumberMaximumDescriptionNodes15Group 1 is assigned to the Lifeline association group and every device has 5 nodes to associate.When the Siren is received the commands sent by controller to be turned on or off, the Siren will senda basic report of its status to the nodes in association group 1. To change what kind of signal is sent tothe nodes in group 1, please see the detailed description of configuration parameter 80.Configuration ParametersZ-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock furtherenhanced features.IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 . 255 the value sent in the application shall be the desiredvalue minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 minus 56. In case of a two byte value the same logicapplies: Values greater than 32768 may needed to be given as negative values too.Parameter 37: Configure the Siren sound and its volumeThis parameter is used to configure the siren sound and volume as the default setting.Size: 2 Byte, Default Value: 259SettingDescription1Set the volume to 88 dB2Set the volume to 100 dB3Set the volume to 105 dB256The siren sound 1 is selected512The siren sound 2 is selected768The siren sound 3 is selected1024The siren sound 4 is selected1280The siren sound 5 is selectedParameter 80: Enable/Disable to send notifications to associated devices to associated devices.This parameter is used to Enable/Disable to send notifications to associated devices (in Group 1) when the state of Siren Gen5u2019s load is changed. (0 Sendnothing, 1 Send hail CC, 2 Send basic report CC).Size: 1 Byte, Default Value: 0SettingDescription0Send Nothing (Disabled)1Send HAIL Command2Send BASIC Report CommandParameter 200: Partner IDThis parameter is used to configure the partner ID. (0 Aeon Labs Standard Product, 1 255 others).Size: 1 Byte, Default Value: 0SettingDescription0Aeon Labs Standard Product1 - 255Partner ID of Partner ProductParameter 252: Enable/Disable Lock ConfigurationThis parameter is used to enable/disable Lock all configuration parameters. (0 disable, 1 enable)Size: 1 Byte, Default Value: 0SettingDescription0All configuration parameters are configurable.1All configuration parameters are not configurable (Locked).Parameter 255: Reset to default factory settingThis parameter is used to reset product to default factory setting. (There are just 2 values can be used).Size: 4 Byte, Default Value: 0SettingDescription1Resets all configuration parameters to default setting.1431655765Reset the product to default factory setting and be excluded from the Z-wave network.Technical Datahttp://manual.zwave.eu/backend/make.php?lang en&sku AEO DSD31Pagina 3 van 5

29-09-2020 15:51Dimensions84x57x67 mmWeight83 grHardware PlatformZM5202EAN1220000012592IP ClassIP 20Voltage230VDevice TypeSirenNetwork OperationAlways On SlaveZ-Wave Version6.51.01Certification IDZC10-14090013Z-Wave Product Id0x0086.0x0004.0x0050FrequencyEurope - 868,4 MhzMaximum transmission power5 mWSupported Command ClassesAssociationAssociation Group InformationBasicConfigurationDevice Reset LocallyFirmware Update MdManufacturer SpecificPowerlevelScene ActivationScene Actuator ConfSecuritySwitch BinaryVersionZwaveplus InfoControlled Command ClassesHailScene ActivationExplanation of Z-Wave specific termsController — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated wallcontrollers.Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls.Primary Controller — is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network.Inclusion — is the process of adding new Z-Wave devices into a network.Exclusion — is the process of removing Z-Wave devices from the network.Association — is a control relationship between a controlling device and a controlled device.Wakeup Notification — is a special wireless message issued by a Z-Wave device to announces that is able to communicate.Node Information Frame — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.(c) 2020 Z-Wave Europe GmbH, Antonstr. 3, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwave.eu. The template is maintained by Z-WaveEurope GmbH. The product content is maintained by Z-Wave Europe GmbH , Supportteam, support@zwave.eu. Last update of the product data: ake.php?lang en&sku AEO DSD31Pagina 4 van 5

29-09-2020 15:51http://manual.zwave.eu/backend/make.php?lang en&sku AEO DSD31Pagina 5 van 5

Siren Gen5 SKU: AEO_DSD31 Quickstart This is a secure Siren for Europe. To run this device please connect it to your mains power supply. Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action button that you can find on the product"s housing.

Related Documents:

Aeon Labs ZW074 4-in-1 Multisensor Aeon Labs DSD31 Siren Aeotec ZW120 Door Window Sensor 5 Aeotec ZW112 Door-Window Sensor 6 Aeotec DSB29-ZWUS Door/Window Sensor Aeotec ZW062 Garage Door Opener 5 Aeotec DSB05-ZWUS Multi-Sensor 5 Aeotec ZW100-A Multi-Sensor 6 Aeotec DSA38-ZWUS Panic Button Aeotec ZW080-A17 Siren Aeotec DSB45-ZWUS Water Sensor

Mar 09, 2017 · Multisensor Gen5 user guide. Modified on: Thu, 9 Mar, 2017 at 5:41 PM Aeotec by Aeon Labs Multisensor Gen5. Aeotec Multisensor Gen5 has been crafted to power connected lighting using Z-Wave Plus. It is powered by Aeotec’s Gen5 technology. To see whether Multisensor 6 is know

Aeotec AEOEZW139 Single Nano Switch User Manual November 7, 2021November 9, 2021 Home » Aeotec » Aeotec AEOEZW139 Single Nano Switch User Manual Aeotec AEOEZW139 Single Nano Switch User Manual. . (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct .

Siren Gen5 is intended for indoor use in dry locations only. Do not use in damp, moist, and / or wet locations. Quick Start. Getting your Siren up and running is as simple as plugging it into a wall socket and linking it to your existing Z

Except in Gen5 Secure, access to Gen5's functions, like reading a plate, modifying a protocol, and masking values, is defined equally for all users except the System Administrator, who has all "permissions." Learn more on page 5. Learn about Gen5's Databases You can opt to sa

Gen5: The purchase of Gen5 entitles the installation of the licensed copy on up to five (5) computers for simultaneous use. The installation of Gen5 on one computer for the purpose of controlling one or two BioTek microplate reader

Light System Manager gen5, 8,000 Node 103-000042-08 912400134291 Light System Manager gen5, 12,000 Node 103-000042-12 912400134292 Light System Manager gen5, 15,000 Node 103-000042-15 912400134293 Use Item Number when ord

First aiders must complete a training course approved by the Health and Safety Executive (HSE). 20 At school, the main duties of a first aider are to: give immediate help to casualties with common injuries or illnesses and those arising from specific hazards at school; when necessary, ensure that an ambulance or other professional medical help is called. PERSON? WHAT IS AN APPOINTED . 21 An .