CUH-14 COMMERCIAL HYDRONIC PRODUCTSA MESTEK COMPANYCabinetUnit HeatersFOR STEAM AND HOT WATER

CABINET UNIT HEATERSSELECTION AND "ROUGH IN" MADE EASYONLY THE LENGTHS VARYThe Sterling Cabinet Unit Heater is theindustry’s most recent design. Years ofmanufacturing and engineering experience combined with a concern for appearance have resulted in a crisply styledunit that will blend with almost any roomdecor and provide reliability, durability,individual control and quiet operation.As unit size increases, only the lengthchanges. The depth and height remainconstant, thus allowing the designer tohave uniformity of appearance when unitsof various sizes are installed in adjacentareas.The wide selection of floor, wall and ceilingunits with a variety of air flow arrangementsallows for exactly matching design requirements.The standard 16-gauge front panel isrugged enough to withstand harsh treatment. Exposed cabinetry is provided with aneutral eggshell baked powder finish. Backand side panels are 18-gauge.2The pedestal base for floor models is theheight of most mop boards.Field repainting to match the decor ispossible and factory applied decoratorcolors are available as an option.Recessed models are provided with a fieldinstalled wall seal that allows for full orpartial recessing depending on the model.The wall seal kit is also available as anoption for full or partial recessing of mostother models.The solid state speed control providesinfinite variations from high to low speed,giving the occupant finger tip control overfan speed and room temperature.All Sterling commercial hydronic productsare made from recycled materials. Materialrecycled contents can be obtained fromyour local Sterling representative.All units are CSAcertified.

10 MODELS - 28 ARRANGEMENTS - 8 CFM SIZESFIFFLOOR TYPE, INVERTED FLOWFLOOR TYPEFSFLOOR TYPE SLOPE TOPFSIFLOOR TYPE SLOPE TOP, INVERTED FLOWW&WIWALL TYPE and INVERTED FLOWRW&RWIRECESSED WALL and INVERTED FLOWCCEILING MOUNTEDRCRECESSED CEILING MOUNTEDSee page 6 for arrangements.3

CABINET UNIT HEATER STANDARD FEATURES- Adjustable wall seal to suit recessing requirements.- Copper Aluminum coil for steamor hot water.- Support bracket to wall.- Whisper quiet blowers.- Cabinet finishneutral eggshellbaked powder.- Leveling legs optional.- Motors - Permanentsplit capacitor.- 16-Gauge steel front panel withinsulation, standard.- Permanent washable filter,aluminum fiber media.- Outside air knockoutprovided standard on“F” and “FS” models.- Speed Control / Access doors - Standard onall floor and wall models.- Steam Coil (Standard) - Brazed copper tube and headerwith aluminum fin. Factory tested to 250 PSI.- Access Area typicalboth ends.- Optional High Capacity2 row coil.4

CABINET UNIT HEATERSRATINGS AND SPECIFICATIONSWALL SEAL - The optional wall seal kit with gasket isdesigned to allow for easy installation and permanent protection for the wall board, plaster orsheet rock surrounding the unit on recessed models.COILS STANDARD ONE ROW - The durable mechanicallybonded copper/aluminum coil presents the bestof today’s hydronic technology. Providing 12 fins perinch with 1/2" nominal diameter tubes, the ultimatein BTU capacity is provided without sacrificing noise,vibration or amp draw. All element assemblies aresubmersion tested at factory at 250 PSI and arerated at a working pressure of 300 PSI All units aredesigned so that field modifications can be madeto reverse the coil position if required.HIGH CAPACITY COIL - This is a hot water coildesigned to provide increased capacity whenthe required load exceeds that of the standardcoil for a given size. Its construction is similar to thestandard coil; however, fins are double depth andthere are two rows of tubes. Element assembliesare submersion tested at 250 PSI and are rated at aworking pressure of 300 PSIBLOWER FAN ASSEMBLY - The blower fan assemblyprovides one of the industry’s best CFM output perunit size. The sizes range from 200 CFM up to the1400 CFM unit at 115 volts. This is the widest rangeof sizes in the industry. The Low Noise blower assemblyis made with galvanized steel, providing long lifeand durability.MOTORS - Standard motors are (PSC) permanentsplit capacitor. This provides the ultimate in motorlife, operating cost, noise levels and dependability.A standard shaft size of 1/2" diameter is the same onall motors. By using a solid state variable speedswitch, a range of speeds can be achieved. Motorsare either 1/15 or 1/10 HPECM MOTOR - Optional motors are ElectronicallyCommutated Motors (ECM). These motors arehighly efficient at full and part load with efficienciesup to 85% compared to 40% with traditional PSCmotors. The ECM motors are also 1/15 or 1/10 HP withlow power consumption, providing energy savingswhich will satisfy green building initiatives.FILTER - The standard permanent filter is made ofdurable aluminum which has an average arrestanceof 69%. Light and easy to handle, the filter slides intoits locating channel and is permanently held inposition with factory supplied cotter pins.FRONT PANEL - 16-gauge front panel is standard with1/2" - 1-1/2 lb. density, neoprene one side insulationin front of the coil. Full panel insulation is availableas an option. Tamper resistant fasteners are alsoavailable.MOTOR/BLOWER SHELF - Support shelf adds supportto units strength and structural integrity. A supportgusset is supplied with 600 CFM units and up.FINISH - Standard finish is an aesthetically pleasingneutral eggshell baked powder, which is suitable forfield repainting if necessary. Optional colors available as shown on color chart.LEVELING LEG - Optional leveling legs are available.Four (4) legs per unit allow adjustment for pitch andyaw when unit is mounted on uneven floors.SPEED CONTROL / ACCESS DOOR - The solid statespeed control allows infinite speed selection forcomfort control. Located under the finger touchaccess door, the speed control is out of view yeteasily accessible. The access door requires just thepressure of a finger to open and swings 120 to astay open position. The access door comes with astandard 1/4 turn/philips head fastener and is available with optional tamper resistant fastener. Speedcontrol switch is not mounted on C or RC units.ACCESS AREA - A spacious rough-in area is providedbetween the unit ends and the internal cabinet atboth ends. The removable front panel allows fullaccess to the piping and valve area (left-handstandard) and to the wiring, switch area.Right hand shown. The rear portion is enclosed withsheet metal.HINGED PANEL / CEILING UNIT - The hinged panelson all ceiling units are standard. Stop chains arestandard. Speed control switches are shipped insideunit with wiring diagram. Switch can be mountedinternal or remote from unit.CONSTANT CABINET DIMENSIONS - Throughout thedesign of the cabinet unit heater, one feature hasbeen a primary concern - "uniformity." The cabinetdepth is one dimension on all unit sizes. Along withthat, the cabinet height is constant on all unitsexcept FS and FSI. Only the length changes onthese models. The internal cabinet allows for allcontrols and piping to be reversible by making alllocator and fastener holes in mirror image.SLOPING TOP CABINETS - Best feature for areas thatcannot tolerate accumulations of books, cups,paper, etc.5

CABINET UNIT HEATERSMODELS AND AIRFLOW ARRANGEMENTSMODELFloorARRANGEMENT NUMBERFF-1000FloorInverted FlowF-101025% F.A.F-1020F-1030 See options 18 & 19 25% F.A.FIFI-1040SlopeFSFS-1005SlopeInverted FlowFI-1050FS-101525% F.A.FS-1025FS-1035 See options 18 & 19 25% F.A.FSIFSI-1045WallFSI-1055WW-1060WallInverted FlowW-1070WIWI-1090Recessed WallRWRecessed WallInverted 1190RC-1200RC-1210CAT00207MODELS, ARRANGEMENTS AND SIZES ARE DESIGNATED AS FOLLOWS:EXAMPLE - RC - 1190 - 086MODEL ARRANGEMENT SIZESIZECFM0203040608101214230 335 430 630 860 1060 1230 1410

CABINET UNIT HEATERSRATINGS AND SPECIFICATIONSENTERING WATER - 200 FENTERING AIR - 60 FTABLE 1UNIT 811.98128.612.86MBHEDRCond. .131377.785.435688.4104.1434107.7108.2451112Number Fins Per InchFace Area-Ft.2Coil 1-1/4CUNumberDiameter/Width (In)HP15-3/4 x 71/1515-3/4 x 71/1525-3/4 x 71/1025-3/4 x 71/1045-3/4 x 53 - 600.8VAR.3352701/151120/1/600.453 - 601.4VAR.4303451/151120/1/600.653 - 601.4VAR.6305051/151120/1/600.853 - SPEED6304403201PERM.43-3/48-11/161/235-3/4 x 71 @ 1/101 @ 53 - SPEED10607405601PERM.50-3/48-11/161/245-3/4 x 71/10RPM:35-3/4 x 71 @ 1/101 @ 1/1510508752115/1/602.2VAR.8606851/102120/1/601.53 - 602.8VAR.12309851/42120/1/602.83 - /602.8VAR.141011301/42120/1/602.83 - 1/25673259-1/25685259-1/2Heating Cap. - HotWater20 WTDHigh Cap. - Coil 2 RowHeating Cap.Hot Water20 WTDHeating Cap. - Steam2 PSIGStandardCoilCoil:Blowers:Standard PSC Motor:HighLowNumberVolts/Phase/HertzAmperesFan Speed ControlStandard MtrCFM:HighLowOptional ECM Motor:HPNumberVolts/Phase/HertzAmperesFan Speed ControlECMCFM:HighMedLowFilter:No.TypeLength (In)Width (In)Thickness (In)dB. Level 18" From UnitLength (In)Height (In)Depth (In)CABINET UNIT HEATERSSHIPPING WEIGHT 831017617818519412196198207215142212232342437

CABINET UNIT HEATERSHEATING CAPACITIESENTERING WATER - 200 FENTERING AIR - 60 FTABLE 2 — STANDARD 06.809.55LOW FAN SPEEDHIGH FAN 16117119120

CABINET UNIT HEATERSHEATING CAPACITIESENTERING WATER - 200 FENTERING AIR - 60 FTABLE 3 — HIGH CAPACITY – 2 ROW 04.1510.4514.55LOW FAN SPEEDHIGH FAN 91491551581601611431461491521539

SELECTIONSELECTION PROCEDURE1. Determine job requirementsFormulas: BTU/HR at rated conditions a. Type of heating (steam or hot water).BTU/HR at required conditionsb. Minimum heating capacity (BTU/HR or EDR).CONVERSION FACTOR2. Select unit sizeFT (Final Air Temperature) a. If necessary convert the required BTU/hr toBTU/HRrated conditions as specified in the capacityEntering Air Temp. F CFMx 1.085tables. (Refer to the formulas at right).b. Select unit(s) from tables with capacitiesequal to or slightly higher than the BTU/HRGPM (Gallons Per Minute) required. Read directly the motor HP andBTU/HRfan RPM.Water Temperature Drop x 500HOT WATER COIL CAPACITYEXAMPLE:Heating loadEntering air tempEntering water tempWater temp drop34,000 BTUH60 F140 F30 FTable 1 on page 7shows selection of size 06 (2 rowcoil) with 69,800 BTU at 20 Fwater temp drop, sufficientfor application.From Table 7, page 12Correction Factor .571for 140 F entering water tempCapacity at 20 F water temp dropwith 140 F entering water 69,800 x .571 39,856 BTUHFrom Table 8, page 12Capacity Correction Factor .90for 30 F water temp dropWater Flow at 20 F water tempdrop with 140 F entering water 39, 856 3.99 GPM(500 x 20)Equivalent Standard Capacity34,000 66,160 BTUH (.571 x .90)FINAL CALCULATIONS:Actual capacity at water droptemp with 140 F entering water 39,856 x 0.9 35,870 BTUHFrom Table 8, page 12Water Flow Correction Factor .59for 30 F water temp dropWater Flow at 30 F water tempdrop with 140 F entering water 3.99 x .59 2.35 GPMTable 3 on page 9shows 620 CFM for high speed fansettingFinal air temp35,870 60 F 113 F(620 x 1.085)STEAM COIL CAPACITYEXAMPLE:Heating LoadEntering Air TempEnteringSteam Pressure34,000 BTUH60 F10 psigFrom Table 5 Page 11correction is 1.13 for 10 psig.Equivalent Capacity 34,000 30,088 BTUH1.13Condensate Rate Actual CapacityLatent Heat of SteamTable 1 on Page 7shows selection of size 03with 31,400 BTUH is sufficientfor application. 35,482953Actual Capacity 31,400 x 1.13 35,482 BTUHSTATIC PRESSURE CORRECTION FACTORSFOR BTU OUTPUT/WITH STANDARD MOTOREXAMPLE: Unit - C-1150-08 output at 200 /60 F 56 MBH at 6 GPM.Static Pressure .125, Correction factor .79 56,000 x .79 44,240 BTUcorrected.NOTE: H igh Static Motor Options 20 and 51 maintain standard air flowwith external static pressure up to 0.4'' water column.10 37 lbs/hrFinal Air Temp35,482 60 F 157 F335 x 1.085TABLE 4UNITSIZE02030406081012140.0 ESP0.05 ESP0.1 ESP0.125 ESPBTUBTUBTUBTUCFM FACTOR CFM FACTOR CFM FACTOR CFM 0.791.00.82

STEAM CALCULATIONSAND CORRECTION FACTORSI.CAPACITYA. For 2 lbs steam, 60 F entering air temp.Read output directly from Table 1 on page 7.B. For higher steam pressures and orEAT's above or below 60 FMultiply output from Table 1 on page 7 byappropriate correction factor from Table 5 (below).II. FINAL AIR TEMPERATUREA. For 2 lbs steam, 60 F entering air temp.See Table 1 on page 7 for Steam MBH Capacity.See page 10 for Steam Coil Capacity example.B. For capacities calculated in IB (above)Output from IB (above) EAT Final Air Temp.1.085 x CFM from Table 1 page 7III. CONDENSATE PER HOURA. For 2 lbs steam, 60 F entering air temp.Read lbs per hour from Table 1 on page 7.B. For capacities calculated in IB (above)Output from IB (above)Latent Heat from Table 6 lbs per hour of condensateTABLE 5 — STEAM CORRECTION FACTORS BASED ON2 LBS STEAM 60 F EATSTEAM PRESSURE — POUNDS PER SQUARE INCH (SATURATED)ENTERING AIRTEMPERATURE30 F40 F50 F60 F70 F80 F90 F100 1.19TABLE 6 — PROPERTIES OF SATURATED STEAMSTEAM PRESSURE IN POUNDS PER SQUARE INCH perature- FLatent Heatof Steam11

HOT WATER CALCULATIONSAND CORRECTION FACTORSI.CAPACITY @ 20 F TD:A. For 200 F EWT, 60 F EATRead output directly from Table 1 on page 7.B. For EWT and/or EAT aboveor below StandardMultiply output from Table 1 on page 7by factor from Table 7 (below).II. CAPACITY AT OTHER TD'SA. For TD's from 5 to 60 FMultiply output obtained in IA or IB(above) by appropriate factor from Table 8 (below).III. GPM AT OTHER TD'SA. For TD's from 5 to 60 FMultiply GPM of unit for 20 F TDby factor from Table 7 (below) EWT/EATThen multiply by appropriate factor from Table 8 (below).IV. PRESSURE LOSS AT OTHER TD'SA. For TD's from 5 to 60 FMultiply PD of unit for 20 F TDby appropriate factor from Table 8 (below).TABLE 7 — H OT WATER CONVERSION FACTORS BASED ON 200 F ENTERING WATER 60 F ENTERING AIR20 F TEMPERATURE DROPENTERING AIRTEMPERATURE30 F40 F50 F60 F70 F80 F90 F100 FENTERING WATER TEMPERATURE — 20 F WATER TEMPERATURE DROP100 F0.5180.4390.3610.2860.2120.1400.0690.000120 F0.6660.5850.5060.4290.3530.2790.2070.137140 F0.8140.7310.6510.5710.4940.4190.3450.273160 F0.9630.8780.7960.7150.6360.5580.4830.409200 F1.2601.1721.0851.0000.9180.8370.7590.682180 F1.1201.0250.9410.8570.7770.6980.6210.546220 F1.4081.3171.2311.1431.0600.9770.8970.818240 F1.5551.4641.3751.2861.2011.1171.0350.955260 F1.7021.6091.5181.4291.3421.2571.1731.094280 F1.8501.7551.6631.5711.4831.3971.3111.230300 F1.9971.9081.8241.7171.6301.5451.4621.371To obtain the BTU capacity for conditions other than those in the basic capacity tables, multiply the basic rating(200 F when entering water, 60 F entering air,) by the proper constant from the above tables.TABLE 8 — H OT WATER BTU, GPM AND PRESSURE LOSS FACTORS BASED ON STANDARD CONDITIONSOF 200 F ENTERING WATER 60 F ENTERING AIR AND 20 F WATER DROPTEMPERATURE DROP FUSE FACTORS FROM THIS TABLE TO OBTAINAPPROXIMATE RESULTS51015202530405060To obtain BTU for other Water Temperature Drops,multiply basic BTU rating by applicable Factor.1.251.151.081.00.94.90.83.76.72To obtain GPM for other Water Temperature Drops,multiply basic GPM rating by applicable 01.00.60.40.20.13.07To obtain Pressure Loss Feet of Water for othertemperature Drops, multiply Basic loss at 20 F drop byFactor.See page 23 for altitude and glycol correction factors.TABLE 9 — CFM AT VARIOUS EAT12Entering Air Temperature30 F40 F50 F60 F70 F80 F90 FConversion Factor1.061.041.021.000.9820.9640.945

STANDARD EQUIPMENTOPTIONS & ACCESSORY EQUIPMENTBASIC UNIT16-gauge front panel, 18-gauge ends and tops of cold rolled steelfor all units; the internal casing shall be furnished of galvanizedsteel; steam or hot water coil with 1-1/4" copper tube stub ends,115 volt PSC motor of (1/10 or 1/15 HP); centrifugal forward curveddouble width fan wheel with galvanized fan housing; variablespeed fan control located right hand; permanent aluminum filter,cleanable; left hand piping (field reversible, fan switch must alsobe reversed); stamped louvered inlet and outlet as shown incatalog; baked powder eggshell finish. Air flow arrangements donot affect price.ACCESS DOORS - F, FI, FS, FSI, W, WI units, 2 top access doors; RW, RWIunits, 2 front panel access doors. Model C and RC provide no accessdoors in hinged front panel.FACTORY ASSEMBLED OPTIONSOPTION 10 - Limited Access Fasteners - for front panel for all models.Special tool required for opening panel.OPTION 11 - Limited Access Fasteners - for access doors. Not applicable to models C and RC. Special tool required for opening doors.OPTION 12 - Aluminum Grille - in place of standard louver. Heavyduty bar grille has clear anodized finish and can be painted tomatch decorator colors if so specified.OPTION 13 - Decorator Color - may be selected from color selector.A prime coat of neutral eggshell baked powder enamel is standardunless otherwise specified. This may be the final finish or it may bepainted in the field if necessary.OPTION 17 - Louvered Inlet Grille - available on models F or FS.Recommended for aesthetics when option 18,19, 118 or 119 isordered (standard with models FI and FSI).OPTION 18 - 25% Manual Outside Air Damper - outside air intake canbe adjusted from 0 to 25%. Control is by manual quadrant. See Option17. Available for field installation - see option 118. Must be orderedwith models F-1010, FS-1015, F-1030 and FS-1035.OPTION 19 - 25% Motorized Outside Air Damper - opens outside airintake to 25% when blower starts. Closes when blower stops. Overrideswitch is provided to prevent damper operation when desired. SeeOption 17. Available for field installation - see option 119. Must beordered with models F-1010, FS-1015, F-1030 and FS-1035.OPTION 20 - High Static Motor - 1/11 HP -1550 RPM 115/1/60 1.2 ampPSC motor. Will maintain standard air flow against 0.4'' WC max. Seeoption 114.OPTION 21 - Plug In Motor - heavy duty grounded plug in cord set forconnection to convenience outlet. Not CSA approved.OPTION 22 - Motor Starter - manual reset toggle switch with thermaloverload. Unit must be turned off and then back on if overload trips.Not available with ECM.OPTION 23 - Service Switch DPST - provides a handy means ofdisconnecting both hot and neutral power lines.OPTION 24F - Return Air Temperature Control - provides return airthermostat to cycle unit blower(s) if return temperature is too low. Blowershuts off when thermostat is satisfied (adjustable from 55-175 F). For Celsiusorder OPTION 24C. Not recommended for ceiling or inverted flow units.OPTION 26 - Right hand coil connection.OPTION 28 - 1/2" Neoprene Faced Fiberglass Insulation All ExternalPanels of Cabinet.OPTION 29 - High Capacity Coil - two row high capacity coil for hotwater only.OPTION 30 - 1/2" Foil Faced Fiberglass Insulation - Front Panel (CoilArea Only).OPTION 31 - 1/2" Foil Faced Fiberglass Insulation - All External Panels ofCabinet.OPTION 32 - 3/8" Closed Cell Insulation - Front Panel (Coil Area Only).OPTION 33 - 3/8" Closed Cell Insulation - All External Panels of Cabinet.OPTION 40 - 24VAC 40 VA Transformer can be used for powering24VAC devices like control boards, low voltage thermostats, relays,valves, etc.OPTION 50 - ECM Motor with Control Board, 3 Speed Switch andService Switch.OPTION 51 - High Static ECM Motor with Control Board, 3 SpeedSwitch and Service Switch.OPTION 99 - 14-gauge Front Panel.FIELD INSTALLED ACCESSORIESOPTION 113 - Touch Up Paint - Aerosol Spray Can (12 oz).OPTION 114 - Duct Collar Kit - provides flange pieces and hardwarefor field installation of inlet or outlet duct collar over existing louverarea. Louvered area to be removed prior to installation. Standard onRC-1210 inlet and outlet. Standard on C-1150 and RC-1190 outlet.OPTION 116 - Leveling Legs - for floor mounted units - 2 per pedestal,4 per unit.OPTION 118 - 25% Manual Outside Air Damper kit for field installation.See option 18 for description. Consult factoryfor 50% fresh air.OPTION 119 - 25% Motorized Outside Air Damper kit for field installation. See option 19 for description.OPTION 125 - Aquastat Control - strap-on aquastat keeps blower(s)off until return water temperature reaches setpoint (adjustable from100-240 F).OPTION 126A & B - Wall Seal - for recessed installation, either fully or2-1/4" partial. Models where full recess would interfere with inlet and/or outlet airflow may be recessed 2-1/4". See schedule below. NOTE:Wall Seal kits are furnished with models RC, RW and RWI. Kits must beordered under this option number for all other models.TABLE 10 - WALL SEAL SCHEDULE* (see page 20)FULLY2 1/4" PARTIAL OPTIONMODELRECESSEDRECESS126FF-1020, F-1030F-1000, F-1010AFIFI-1050FI-1040AW, RWRW-1120W-1060, W-1070BWI, RWIRWI-1130WI-1090, WI-1100BC, RC C-1170, RC-1200 C-1140, C-1150BC-1160, C-1180RC-1190, RC-1210*Not Applicable to models FS or FSI.OPTION 127 - Line Voltage Room (Wall) Thermostat - T22AAA-1, S.P.S.T.heating only with “Off-Auto” selector switch. Range 40-90 F. Rated 6.0amps @ 120 VAC.OPTION 129 - Extra Filter - provides an additional filter (permanentaluminum mesh). One required per unit, all sizes.OPTION 140 - 24VAC 40 VA Transformer can be used for powering24VAC devices like control boards, low voltage thermostats, relays,valves, etc.13

SIONAL ntedUnitsFILTER IDENTIFICATIONANDDATAFILTERSIZEPARTSIZE PARTFILTERSIZENO.NO.SIZEModelandFIFIF FSIZEandFILTERSIZE PART NO. Model15/32"8 11/16"19 3/4"x 8 x11/16"x 19x 3/4"02 02 PC1297-2ModelsFPC1297-2and15/32"FI15/32" x 8 11/16" x 19 3/4"02 PC1297-2PC1297-315/32"x811/16"x273/4"0315/32" x 8 11/16" x 27 3/4"03 PC1297-315/32" x 8 11/16" x 27 3/4"03 PC1297-3PC1297-415/32"8 11/16"31 3/4"15/32"x 8 x11/16"x 31x 3/4"04 04 PC1297-415/32" x 8 11/16" x 31 3/4"04 PC1297-4PC1297-615/32"8 11/16"43 3/4"06 06 PC1297-615/32"x 8 x11/16"x 43x 3/4"06 PC1297-615/32" x 8 11/16" x 43 3/4"PipingorPC1297-8 bottom15/32"8 11/16"45rear.3/4"PC1297-815/32"x 8 x11/16"x 45x 3/4"08 08 from15/32" x 8 11/16" x 45 3/4"08 PC1297-8PC1297-1010 10 PC1297-10PC1297-1212 12 PC1297-12PC1297-1414 14 PC1297-1415/32"8 11/16"50 3/4"15/32"x 8 x11/16"x 50x 3/4"15/32"8 11/16"57 3/4"15/32"x 8 x11/16"x 57x 3/4"15/32"8 11/16"69 3/4"15/32"x 8 x11/16"x 69x 3/4"101214PC1297-10PC1297-12PC1297-14Floor Mounted UnitsModel F and FI15/32" x 8 11/16" x 50 3/4"15/32" x 8 11/16" x 57 3/4"15/32" x 8 11/16" x 69 3/4"1 1/4"NOMINAL1 1/4"NOMINALTYPE"L" COPPERTUBINGTYPE"L" COPPERTUBINGHOTWATERRETURNHOT WATER RETURN1 1/4"NOMINAL1 1/4"NOMINALTYPE"L" CU.TUBINGTYPE"L" CU.TUBINGWATERRETURNHOTHOTWATERRETURN1 1/4" NOMINALTYPE "L" COPPER TUBINGHOT WATER RETURNDISCHARGETOPTOPDISCHARGEGRILLEGRILLE1 1/4"NOMINAL1 1/4"NOMINAL1 1/4"NOMINALTYPE "L"TYPECU.TYPETUBING"L" COPPERTUBING"L" COPPERTUBINGHOT WATER HOTRETURNWATERSUPPLYHOT WATERSUPPLY1 1/4"NOMINAL1 1/4"NOMINALTYPE"L" CU.TUBINGTYPE"L" TROLELECTRICALCONTROLACCESSDOORACCESSDOORTOP DISCHGRILLE1 1/4" NOMINALTYPE "L" COPPER TUBINGHOT WATER SUPPLYWALLWALLLINELINE1 1/4" NOMINALTYPE "L" CU. TUBINGHOT WATER SUPPLYTOPTOPVIEWVIEWTOP FI FIMODELMODELF FTWOROWCOILTWOROWCOILPIPINGDIMENSIONS.PIPING DIMENSIONS.PLUMBINGACCESS DOORMODEL FIMODEL F"L""L""L"TWO ROW COILPIPING DIMENSIONS.1 1/4"NOMINAL1 1/4"NOMINALTYPE"L" COPPERTUBINGTYPE"L" TWATERRETURN(SHOWN ABOVE)(SHOWNABOVE)(SHOWNABOVE)1 1/4"NOMINAL1 1/4"NOMINALTYPE"L" CU.TUBINGTYPE"L" TERRETURNSPEEDCONTROLSPEEDCONTROL1 1/4" NOMINALTYPE "L" COPPER TUBINGSTEAM SUPPLYHOT WATER RETURN1 1/4" NOMINALTYPE "L" CU. TUBINGSTEAM1SUPPLY1 1/4"NOMINAL1/4"NOMINALHOT WATERRETURNTYPE"L" COPPERTUBINGTYPE"L" TWATERSUPPLY1 1/4"NOMINAL1 1/4"NOMINALTYPE"L" CU.TUBINGTYPE"L" CU.TUBING1 1/4" NOMINALTYPE "L" COPPER M RETURNHOT WATER SUPPLY CANCANBE WIREDBE WIREDFROMBACKFROMBACKOR BOTTOMOR BOTTOMOF UNIT.OF UNIT.1 1/4" NOMINALTYPE "L" CU. SUPPLYSTEAM RETURNHOT WATER SUPPLY* *MODELFI NTFI-1040MODELF MODEL FISIDE VIEWARRANGEMENT FI-1040*MODELMODELF FFRONTFRONTVIEWVIEWSTANDARD ONE ROW COILPIPING DIMENSIONS.(SHOWN OR1" LOORMOUNTEDUNITSMODELS"F ANDFI" -FI"WITHTOPTOPDISCHARGE.MODELS"F AND- WITHDISCHARGE.PIPING AND MOUNTING CONNECTIONS SHOWN ARE TYPICAL FRESHAIR AIRINLETFRESHINLETOPENINGIN INTERNALCABINETOPENINGIN INTERNALCABINETFOR ALL AIR FLOW EQUIREDSEE PAGE 6 for other air flow arrangements."A" "A"* LOUVEREDINLETGRILLEIS IS* LOUVEREDINLETGRILLESTANDARDON ON"FI" "FI"MODELSSTANDARDMODELSOPTIONALON ON"F" MODELSOPTIONAL"F" MODELSSEESEEOPTION17 17OPTION14MOUNTING BRACKETSLOTS ALLOW FOR 1"LATERAL ADJUSTMENTTHIS DATA SHEET SHOWS FLOOR MOUNTED UNITSMODELS "F AND FI" - WITH TOP EPAGE6 forotherairairflowarrangements.SEEPAGE6 0,F1010,FI1040ONLY.MODEL FFRONT VIEMODEL FSIDE VIEWARRANGEMENT F-1000* LOUVERED INLET GRILLE ISSTANDARD ON "FI" MODELSOPTIONAL ON "F" MODELSSEE OPTION "A"-"A""A"-"A"MAXIMUM RECESS DEPTHSECTIONSECTIONMODELS F1000, F1010, FI1040 ONLY.CAT00200AFRESH AIR INOPENING I

Unit Heaters. FOR STEAM AND HOT WATER. 2. The Sterling Cabinet Unit Heater is the industry’s most recent design. Years of manufacturing and engineering experi-ence combined with a concern

Related Documents:

Explosion-proof Unit Heaters Comparison Chart 6-7 Ultra-Safe EXP Explosion-proof Unit Heaters (233) 8-14 Compact Explosion-proof Unit Heaters (236) 15-17 Convector (254) 18-25 Fan Forced Heaters Comparison Chart 26 TRIAD Washdown/Corrosion Resistant Unit Heaters (234) 27-30 Industrial Unit Heater IUH Series (238) 31-33 Unit Heater UHIR Series .

Explosion-proof Unit Heaters Comparison Chart 6-7 Ultra-Safe EXP Explosion-proof Unit Heaters (233) 8-13 Compact Explosion-proof Unit Heaters (236) 14-16 Convector (254) 17-24 Fan Forced Heaters Comparison Chart 25 TRIAD Washdown/Corrosion Resistant Unit Heaters (234) 26-29 Industrial Unit Heater IUH Series (238) 30-32 Unit Heater UHIR Series .

Explosion-proof Unit Heaters Comparison Chart 6-7 Ultra-Safe EXP Explosion-proof Unit Heaters (233) 8-14 Compact Explosion-proof Unit Heaters (236) 15-17 Convector (254) 18-25 Fan Forced Heaters Comparison Chart 26 TRIAD Washdown/Corrosion Resistant Unit Heaters (234) 27-30 Industrial Unit Heater IUH Series (238) 31-33 Unit Heater UHIR Series .

Safe area fan heaters, industrial convectors, in line heaters. Vented and unvented storage water heaters, vat heaters. Industrial, domestic, baptistry and portable immersion heaters. Externally adjustable flameproof immersion heaters, thermostats and radiators. Drum heaters silicone rubber an

Types of Portable Propane Radiant Heaters Currently, there are three types of portable propane radiant heaters available to consumers: (1) single burner radiant heaters, (2) radiant heaters that also function as cookers, and (3) radiant heaters equipped with an Oxygen Depletion Sensor (ODS). The singl

Explosion-Proof Electric Unit Heaters Explosion-Proof Convection Heaters . The heater core assembly is contained in a sturdy, epoxy-coated, 12-gauge . Cata-Dyne is the industry standard in infrared gas catalytic heaters, enclosures, pipeline systems and accessories. Customers across a wide range

Nailor Industries Inc. Electric Duct Heaters have been tested and approved to the following standards by ETL Testing Laboratories Inc., Courtland, N.Y. (Listing Report No. 554250. Category: Duct Heaters 327 U.S.A. and 328 Canada) ANSI/UL Standard 1996, "Electric Duct Heaters" CSA Standard C22.2 No. 155-M1986. "Electric Duct Heaters"

on criminal law reforms which I had begun in 2001 when still working as an attorney. Observing the reforms in action and speaking with judges and lawyers not only helped to inform my own work, but also helped me to see how legal reform operates in a