MachFlex Industrial Cables

2y ago
101 Views
2 Downloads
4.07 MB
24 Pages
Last View : 4m ago
Last Download : 2m ago
Upload by : Gannon Casey
Transcription

MachFlex Industrial CablesThe Ideal Signal TransmissionCable Solutions for MachineBuilders

About MachFlex Industrial CablesBelden introduces themachine builder choiceMachFlex cables based onthe following internationalstandards:DIN EN 50525-2-51 Customer ChallengeApplication AdvantageMachines are becoming highly systemized,smaller and compact driven by specialrequirements of end users and customers.These challenge machine builders who needto stay competitive while ensuring a robustperformance for their machine. Belden isintroducing a new line of flexible machinecables to aid machine builders tackle thischallenge by offering cables in smaller sizesthat save installation space and are highlydurable to meet the flexibility, physical andmechanical requirements needed.Belden‘s machine builder choice MachFlexcables have the following advantages whichensures greater performance level for themachine builders and a higher uptime for theend users:Applications Good Sunlight (UV) & Chemical ResistantMachine builders are continuously looking toimprove the performance of their machinesused in industries such as food & beverage,health care, manufacturing, pharmaceuticals,automotive, semiconductors and many more.Some of the main applications where thesecables can be used, but not restricted to, are: Precision control sensors Multi axis motion control Temperature controllers Control panels Machine cutting tools Auxiliary equipment Motor speed controls Production machinery Blade pitch control (WT) Control & instrumentation circuits2 Flexible conductor, insulation & sheathmaterial Oil resistant DIN EN 50290-2-22 (TM54) Wider fixed temperature range (-40 C To 80 C) Good shield effectiveness Environmental friendly cables (RoHS)Product FeaturesMajor features of the new machine builderchoice MachFlex cables include: Various conductor sizes from 0.5mm² up to25mm2 Bare copper conductors (DIN VDE 0295) PVC insulation & jacket / sheath Optional ground wire in green  /  yellow color Optional tinned copper braid (CY) Optional steel wire braid (SY) Voltage (Uo/U) 300/500V or 470/750V Variety of insulation & jacket color options Drum packaging

MachFlex Cabling SolutionsTable of ContentsTable of ContentsPage3MachFlex 350 PVC CablesMachFlex 350 YY Unshielded Cables OverviewMachFlex 350 YY Unshielded CablesMachFlex 350 CY Tinned Copper Braid Shielded (CY) Cables OverviewMachFlex 350 CY Tinned Copper Braid Shielded (CY) CablesMachFlex 350 SY Galvanized Steel Wire Braid Armored (SY) Cables OverviewMachFlex 350 SY Galvanized Steel Wire Braid Armored (SY) Cables45-678-91011-12MachFlex 375 PVC CablesMachFlex 375 YY Unshielded Cables OverviewMachFlex 375 YY Unshielded CablesMachFlex 375 CY Tinned Copper Braid Shielded (CY) Cables OverviewMachFlex 375 CY Tinned Copper Braid Shielded (CY) CablesMachFlex 375 SY Galvanized Steel Wire Braid Armored (SY) Cables overviewMachFlex 375 SY Galvanized Steel Wire Braid Armored (SY) Cables1314-151617-181920-213

MachFlex 350 YY CablesUnshielded PVC Control CablesApplicationsDesigned for applications which are installed in occasional flexing and fixed locations.Cable applications include precision control sensors, multi axis control machines,temperature controllers, control panels, machine cutting tools, auxiliary equipment,motor speed control, production machinery and many more.General Reference Standards DIN VDE 0295, IEC 60228, BS6360DIN EN 50290-2-22, DIN VDE 0207-363-4-1, DIN EN 50525-2-51DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2RoHS, REACH & CE DirectivesConstruction and Performance41.Conductor MaterialStranded bare copper (DIN VDE 0295 Class 5)2.Insulation Material & ColorInsulation Material & Colour PVC (polyvinyl chloride).A) All black color with number coding without protective conductor. B) Blackcolor with number coding plus 1 green & yellow with protective conductor.3.Jacket / Sheath MaterialPVC (polyvinyl chloride)4.Flame RetardancyVDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-25.Voltage Rating (Uo/U)Up to 1.5 mm2: 300 / 500 VFrom 2.5 mm2: 450 / 750 V6.Oil ResistantDIN EN 50290-2-22 (TM54)7.Temperature Range-30 C TO 70 C (Occasional movement)-40 C TO 80 C (Fixed installation)8.Bending Radius10 x OD (Occasional movement)4 x OD (Fixed installation)9.Other PropertiesGood UV resistance, chemical resistance & flexibility

MachFlex 350 YY Unshielded PVC Control CablesUNSHIELDED CABLE WITH (G) PROTECTIVE GROUND1 Conductor2 Insulation3 Inner Sheath321Conductor 0.50 mm2No. ofCores34571220Nom. OverallDiameter (mm)4.95.35.96.48.610.8 DIN VDE 0295, IEC 60228, BS6360DIN EN 50290-2-22, DIN VDE 0207-363-4-1DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2DIN EN 50525-2-51RoHS, REACH & CE DirectivesConductor 0.75 mm2Copper t Code3GA4GA5GA7GA12GA20GAAPACPart Code3G0.54G0.55G0.57G0.512G0.520G0.5Conductor 1.00 mm2No. ofCores34571220Nom. OverallDiameter (mm)5.45.96.57.29.612.1Copper rt Code3GB4GB5GB7GB12GB20GBAPACPart r 1.50 mm2No. of Nom. OverallCopper WeightCores Diameter .001210.5192.002013.2Conductor 2.50 mm2EMEAPart Code3GC4GC5GC7GC12GC20GCAPACPart Code3G1.04G1.05G1.07G1.012G1.020G1.0No. of Nom. OverallCopper WeightCores Diameter 11.5173.002014.5288.30Conductor 4.00 mm2EMEAPart Code3GD4GD5GD7GD12GD20GDAPACPart Code3G1.54G1.55G1.57G1.512G1.520G1.5No. of Nom. OverallCopper WeightCores Diameter 2288.001215.2480.002019.2Conductor 6.00 mm2EMEAPart Code3GE4GE5GE7GE12GE20GEAPACPart Code3G2.54G2.55G2.57G2.512G2.520G2.5No. of Nom. OverallCopper WeightCores Diameter 13.3345.90916.6461.001218.1Conductor 10.00 mm2EMEAPart Code3GF4GF5GF7GF9GF12GFAPACPart Code3G44G45G47G49G412G4No. ofCores34579EMEAPart Code3GG4GG5GG7GG9GGAPACPart Code3G64G65G67G69G6No. ofCores34579EMEAPart Code3GH4GH5GH7GH9GHAPACPart Code3G104G105G107G109G10EMEAPart Code3GJ4GJ5GJ7GJAPACPart Code3G254G255G257G25Nom. OverallDiameter (mm)11.813.114.516.020.1Copper or 16.00 mm2No. ofCores3457Nom. OverallDiameter (mm)18.120.222.424.8Nom. OverallDiameter (mm)14.816.518.320.325.5Copper or 25.00 mm2Copper Weight(kg/km)460.50614.00768.001,075.00EMEAPart Code3GI4GI5GI7GIAPACPart Code3G164G165G167G16No. ofCores3457Nom. OverallDiameter (mm)22.324.927.730.6 Putup length & tolerance of the cables will vary depending on the construction of the cable MOQ will vary depending on the construction of the cable & provided at the time of quotation Cable requested outside the above design criteria can be reviewed and quotedCopper Weight(kg/km)720.00960.001,200.001,680.005

MachFlex 350 YY Unshielded PVC Control CablesUNSHIELDED CABLE WITHOUT (G) PROTECTIVE GROUND1 Conductor2 Insulation3 Inner Sheath321Conductor 0.50 mm2No. ofCores34571220Nom. OverallDiameter (mm)4.95.35.96.48.610.8DIN VDE 0295, IEC 60228, BS6360DIN EN 50290-2-22, DIN VDE 0207-363-4-1DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2DIN EN 50525-2-51RoHS, REACH & CE DirectivesConductor 0.75 mm2Copper t Code3XA4XA5XA7XA12XA20XAAPACPart Code3X0.54X0.55X0.57X0.512X0.520X0.5Conductor 1.00 mm2No. ofCores34571220Nom. OverallDiameter (mm)5.45.96.57.29.612.1Copper rt Code3XB4XB5XB7XB12XB20XBAPACPart r 1.50 mm2No. of Nom. OverallCopper WeightCores Diameter 0.5115.002013.2192.00Conductor 2.50 mm2EMEAPart Code3XC4XC5XC7XC12XC20XCAPACPart Code3X1.04X1.05X1.07X1.012X1.020X1.0No. of Nom. OverallCopper WeightCores Diameter 11.5173.002014.5288.30Conductor 4.00 mm2EMEAPart Code3XD4XD5XD7XD12XD20XDAPACPart Code3X1.54X1.55X1.57X1.512X1.520X1.5No. of Nom. OverallCopper WeightCores Diameter 01215.2288.002019.2480.00Conductor 6.00 mm2EMEAPart Code3XE4XE5XE7XE12XE20XEAPACPart Code3X2.54X2.55X2.57X2.512X2.520X2.5No. of Nom. OverallCopper WeightCores Diameter 9.00916.6345.901218.1461.00Conductor 10.00 mm2EMEAPart Code3XF4XF5XF7XF9XF12XFAPACPart Code3X44X45X47X49X412X4No. ofCores34579EMEAPart Code3XG4XG5XG7XG9XGAPACPart Code3X64X65X67X69X6No. ofCores34579EMEAPart Code3XH4XH5XH7XH9XHAPACPart Code3X104X105X107X109X10EMEAPart Code3XJ4XJ5XJ7XJAPACPart Code3X254X255X257X25Nom. OverallDiameter (mm)11.813.114.516.020.1Copper or 16.00 mm2No. ofCores34576 Nom. OverallDiameter (mm)18.120.222.424.8Copper Weight(kg/km)460.50614.00768.001,075.00Nom. OverallDiameter (mm)14.816.518.320.325.5Copper or 25.00 mm2EMEAPart Code3XI4XI5XI7XIAPACPart Code3X164X165X167X16No. ofCores3457Nom. OverallDiameter (mm)22.324.927.730.6 Putup length & tolerance of the cables will vary depending on the construction of the cable MOQ will vary depending on the construction of the cable & provided at the time of quotation Cable requested outside the above design criteria can be reviewed and quotedCopper Weight(kg/km)720.00960.001,200.001,680.00

MachFlex 350 CY CablesShielded (CY) PVC Control CablesTinned Copper Braid Shield (TCB) Excellent Noise ImmunityApplicationsDesigned for applications which are installed in occasional flexing and fixed locations. Cableapplications include precision control sensors, multi axis control machines, temperaturecontrollers, control panels, machine cutting tools, auxiliary equipment, motor speed control,production machinery and many more.General Reference Standards DIN VDE 0295, IEC 60228, BS6360DIN EN 50290-2-22, DIN VDE 0207-363-4-1DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2DIN EN 50525-2-51RoHS, REACH & CE DirectivesConstruction and Performance1.Conductor MaterialStranded bare copper (DIN VDE 0295 Class 5)2.Insulation Material & ColorInsulation Material & Color PVC (polyvinyl chloride).A) All black color with number coding without protective conductor. B) Blackcolor with number coding plus 1 green & yellow with protective conductor.3.Braid Shield MaterialTinned Copper Braid Shield4.Jacket / Sheath MaterialPVC (polyvinyl chloride)5.Flame RetardancyVDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-26.Voltage Rating (Uo/U)Up to 1.5 mm2: 300 / 500 VFrom 2.5 mm2: 450 / 750 V7.Oil ResistantDIN EN 50290-2-22 (TM54)8.Temperature Range-30 C TO 70 C (Occasional movement)-40 C TO 80 C (Fixed installation)9.Bending Radius20 x OD (Occasional movement)6 x OD (Fixed installation)10.Other PropertiesGood UV resistance, chemical resistance & flexibility7

MachFlex 350 CY Shielded (CY) PVC Control CablesTINNED COPPER BRAID SHIELDED CABLE WITH (G) PROTECTIVE GROUND543211 Conductor2 Insulation3 Inner Sheath4 Tinned CopperBraid Shielded5 Outer SheathConductor 0.50 mm2No. ofCores34571220Nom. OverallDiameter (mm)7.27.78.39.111.413.7DIN VDE 0295, IEC 60228, BS6360DIN EN 50290-2-22, DIN VDE 0207-363-4-1DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2DIN EN 50525-2-51RoHS, REACH & CE DirectivesConductor 0.75 mm2Copper art Code3GACY4GACY5GACY7GACY12GACY20GACYAPACPart nductor 1.00 mm2No. ofCores34571220Nom. OverallDiameter (mm)7.78.39.29.912.415.0Copper art Code3GBCY4GBCY5GBCY7GBCY12GBCY20GBCYAPACPart 75CYConductor 1.50 mm2No. of Nom. OverallCopper WeightCores Diameter 213.3184.342016.1307.23Conductor 2.50 mm2EMEAPart Code3GCCY4GCCY5GCCY7GCCY12GCCY20GCCYAPACPart . of Nom. OverallCopper WeightCores Diameter 21214.4274.402017.5457.33Conductor 4.00 mm2EMEAPart Code3GDCY4GDCY5GDCY7GDCY12GDCY20GDCYAPACPart . of Nom. OverallCopper WeightCores Diameter 82.241218.2467.752022.7779.58Conductor 6.00 mm2EMEAPart Code3GECY4GECY5GECY7GECY12GECY20GECYAPACPart . of Nom. OverallCopper WeightCores Diameter 84.16920.0493.921221.5658.56Conductor 10.00 mm2EMEAPart Code3GFCY4GFCY5GFCY7GFCY9GFCY12GFCYAPACPart Code3G4CYNo. ofCores34579EMEAPart Code3GGCY4GGCY5GGCY7GGCY9GGCYAPACPart Code3G6CY4G6CY5G6CY7G6CY9G6CYNo. ofCores34579EMEAPart Code3GHCY4GHCY5GHCY7GHCY9GHCYAPACPart Code3G10CY4G10CY5G10CY7G10CY9G10CYEMEAPart Code3GJCY4GJCY5GJCY7GJCYAPACPart Code3G25CY4G25CY5G25CY7G25CYNom. OverallDiameter (mm)14.616.017.519.123.6Copper or 16.00 mm2No. ofCores34578 Nom. OverallDiameter (mm)21.523.626.028.5Copper Weight(kg/km)594.86787.92916.301,282.82Nom. OverallDiameter (mm)17.819.821.723.829.2Copper 5G4CY7G4CY9G4CY12G4CYConductor 25.00 mm2EMEAPart Code3GICY4GICY5GICY7GICYAPACPart Code3G16CY4G16CY5G16CY7G16CYNo. ofCores3457Nom. OverallDiameter (mm)25.928.631.534.2 Putup length & tolerance of the cables will vary depending on the construction of the cable MOQ will vary depending on the construction of the cable & provided at the time of quotation Cable requested outside the above design criteria can be reviewed and quotedCopper Weight(kg/km)853.331,137.781,372.001,920.80

MachFlex 350 CY Shielded (CY) PVC Control CablesTINNED COPPER BRAID SHIELDED CABLE WITHOUT (G) PROTECTIVE GROUND543211 Conductor2 Insulation3 Inner Sheath4 Tinned CopperBraid Shielded5 Outer SheathConductor 0.50 mm2No. ofCores34571220Nom. OverallDiameter (mm)7.27.78.39.111.413.7 DIN VDE 0295, IEC 60228, BS6360DIN EN 50290-2-22, DIN VDE 0207-363-4-1DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2DIN EN 50525-2-51RoHS, REACH & CE DirectivesConductor 0.75 mm2Copper art Code3XACY4XACY5XACY7XACY12XACY20XACYAPACPart nductor 1.00 mm2No. ofCores34571220Nom. OverallDiameter (mm)7.78.39.29.912.415.0Copper art Code3XBCY4XBCY5XBCY7XBCY12XBCY20XBCYAPACPart 75CYConductor 1.50 mm2No. of Nom. OverallCopper WeightCores Diameter 213.3184.342016.1307.23Conductor 2.50 mm2EMEAPart Code3XCCY4XCCY5XCCY7XCCY12XCCY20XCCYAPACPart . of Nom. OverallCopper WeightCores Diameter 21214.4274.402017.5457.33Conductor 4.00 mm2EMEAPart Code3XDCY4XDCY5XDCY7XDCY12XDCY20XDCYAPACPart . of Nom. OverallCopper WeightCores Diameter 82.241218.2467.752022.7779.58Conductor 6.00 mm2EMEAPart Code3XECY4XECY5XECY7XECY12XECY20XECYAPACPart . of Nom. OverallCopper WeightCores Diameter 84.16920.0493.921221.5658.56Conductor 10.00 mm2EMEAPart Code3XFCY4XFCY5XFCY7XFCY9XFCY12XFCYAPACPart Code3X4CY4X4CY5X4CY7X4CY9X4CY12X4CYNo. ofCores34579EMEAPart Code3XGCY4XGCY5XGCY7XGCY9XGCYAPACPart Code3X6CY4X6CY5X6CY7X6CY9X6CYNo. ofCores34579EMEAPart Code3XHCY4XHCY5XHCY7XHCY9XHCYAPACPart Code3X10CY4X10CY5X10CY7X10CY9X10CYEMEAPart Code3XJCY4XJCY5XJCY7XJCYAPACPart Code3X25CY4X25CY5X25CY7X25CYNom. OverallDiameter (mm)14.616.017.519.123.6Copper or 16.00 mm2No. ofCores3457Nom. OverallDiameter (mm)21.523.626.028.5Copper Weight(kg/km)594.86787.92916.301,282.82Nom. OverallDiameter (mm)17.819.821.723.829.2Copper ctor 25.00 mm2EMEAPart Code3XICY4XICY5XICY7XICYAPACPart Code3X16CY4X16CY5X16CY7X16CYNo. ofCores3457Nom. OverallDiameter (mm)25.928.631.534.2 Putup length & tolerance of the cables will vary depending on the construction of the cable MOQ will vary depending on the construction of the cable & provided at the time of quotation Cable requested outside the above design criteria can be reviewed and quotedCopper Weight(kg/km)853.331,137.781,372.001,920.809

MachFlex 350 SY CablesArmored (SY) PVC Control CablesGalvanized Steel Wire Braid (GSWB) Excellent Mechanical ProtectionApplicationsDesigned for applications which are installed in occasional flexing and fixed locations. Cableapplications include precision control sensors, multi axis control machines, temperaturecontrollers, control panels, machine cutting tools, auxiliary equipment, motor speed control,production machinery and many more.General Reference Standards DIN VDE 0295, IEC 60228, BS6360DIN EN 50290-2-22, DIN VDE 0207-363-4-1DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2DIN EN 50525-2-51RoHS, REACH & CE DirectivesConstruction and Performance101.Conductor MaterialStranded bare copper (DIN VDE 0295 Class 5)2.Insulation Material & ColorInsulation Material & Colour PVC (polyvinyl chloride).A) All black color with number coding without protective conductor. B) Blackcolor with number coding plus 1 green & yellow with protective conductor.3.Braid Shield MaterialGSWB (Galvanized Steel Wire Braid)4.Jacket / Sheath MaterialPVC (polyvinyl chloride)5.Flame RetardancyVDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-26.Voltage Rating (Uo/U)Up to 1.5 mm2: 300 / 500 VFrom 2.5 mm2: 450 / 750 V7.Oil ResistantDIN EN 50290-2-22 (TM54)8.Temperature Range-30 C TO 70 C (Occasional movement)-40 C TO 80 C (Fixed installation)9.Bending Radius20 x OD (Occasional movement)6 x OD (Fixed installation)10.Other PropertiesGood UV resistance, chemical resistance & flexibility

MachFlex 350 SY Armored (SY) PVC Control CablesGALVANIZED STEEL WIRE BRAID SHIELD (GSWB) CABLE WITH (G) PROTECTIVE GROUND543211 Conductor2 Insulation3 Inner Sheath4 Galvanized SteelWire Braid Shield5 Outer SheathConductor 0.50 mm2No. ofCores34571220Nom. OverallDiameter (mm)7.58.08.59.111.413.9 DIN VDE 0295, IEC 60228, BS6360DIN EN 50290-2-22, DIN VDE 0207-363-4-1DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2DIN EN 50525-2-51RoHS, REACH & CE DirectivesConductor 0.75 mm2Copper t Code3GASY4GASY5GASY7GASY12GASY20GASYAPACPart nductor 1.00 mm2No. ofCores34571220Nom. OverallDiameter (mm)8.08.69.29.912.415.2Copper rt Code3GBSY4GBSY5GBSY7GBSY12GBSY20GBSYAPACPart 75SYConductor 1.50 mm2No. of Nom. OverallCopper WeightCores Diameter 13.3115.002016.3192.00Conductor 2.50 mm2EMEAPart Code3GCSY4GCSY5GCSY7GCSY12GCSY20GCSYAPACPart . of Nom. OverallCopper WeightCores Diameter 1214.6173.002017.7288.30Conductor 4.00 mm2EMEAPart Code3GDSY4GDSY5GDSY7GDSY12GDSY20GDSYAPACPart . of Nom. OverallCopper WeightCores Diameter .001218.4288.002022.6480.00Conductor 6.00 mm2EMEAPart Code3GESY4GESY5GESY7GESY12GESY20GESYAPACPart . of Nom. OverallCopper WeightCores Diameter 69.00919.9345.901221.5461.00Conductor 10.00 mm2EMEAPart Code3GFSY4GFSY5GFSY7GFSY9GFSY12GFSYAPACPart Code3G4SY4G4SY5G4SY7G4SY9G4SY12G4SYNo. ofCores34579EMEAPart Code3GGSY4GGSY5GGSY7GGSY9GGSYAPACPart Code3G6SY4G6SY5G6SY7G6SY9G6SYNo. ofCores34579EMEAPart Code3GHSY4GHSY5GHSY7GHSY9GHSYAPACPart Code3G10SY4G10SY5G10SY7G10SY9G10SYEMEAPart Code3GJSY4GJSY5GJSY7GJSYAPACPart Code3G25SY4G25SY5G25SY7G25SYNom. OverallDiameter (mm)14.916.217.719.323.5Copper or 16.00 mm2No. ofCores3457Nom. OverallDiameter (mm)21.423.626.128.4Copper Weight(kg/km)460.50614.00768.001,075.00Nom. OverallDiameter (mm)18.019.821.723.729.1Copper or 25.00 mm2EMEAPart Code3GISY4GISY5GISY7GISYAPACPart Code3G16SY4G16SY5G16SY7G16SYNo. ofCores3457Nom. OverallDiameter (mm)25.928.631.233.9 Putup length & tolerance of the cables will vary depending on the construction of the cable MOQ will vary depending on the construction of the cable & provided at the time of quotation Cable requested outside the above design criteria can be reviewed and quotedCopper Weight(kg/km)720.00960.001,200.001,680.0011

MachFlex 350 SY Armored (SY) PVC Control CablesGALVANIZED STEEL WIRE BRAID SHIELD (GSWB) CABLE WITHOUT (G) PROTECTIVE GROUND543211 Conductor2 Insulation3 Inner Sheath4 Galvanized SteelWire Braid Shield5 Outer SheathConductor 0.50 mm2No. ofCores34571220Nom. OverallDiameter (mm)7.58.08.59.111.413.9 DIN VDE 0295, IEC 60228, BS6360DIN EN 50290-2-22, DIN VDE 0207-363-4-1DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2DIN EN 50525-2-51RoHS, REACH & CE DirectivesConductor 0.75 mm2Copper t Code3XASY4XASY5XASY7XASY12XASY20XASYAPACPart nductor 1.00 mm2No. ofCores34571220Nom. OverallDiameter (mm)8.08.69.29.912.415.2Copper rt Code3XBSY4XBSY5XBSY7XBSY12XBSY20XBSYAPACPart 75SYConductor 1.50 mm2No. of Nom. OverallCopper WeightCores Diameter 13.3115.002016.3192.00Conductor 2.50 mm2EMEAPart Code3XCSY4XCSY5XCSY7XCSY12XCSY20XCSYAPACPart . of Nom. OverallCopper WeightCores Diameter 1214.6173.002017.7288.30Conductor 4.00 mm2EMEAPart Code3XDSY4XDSY5XDSY7XDSY12XDSY20XDSYAPACPart . of Nom. OverallCopper WeightCores Diameter .001218.4288.002022.6480.00Conductor 6.00 mm2EMEAPart Code3XESY4XESY5XESY7XESY12XESY20XESYAPACPart . of Nom. OverallCopper WeightCores Diameter 69.00919.9345.901221.5461.00Conductor 10.00 mm2EMEAPart Code3XFSY4XFSY5XFSY7XFSY9XFSY12XFSYAPACPart Code3X4SY4X4SY5X4SY7X4SY9X4SY12X4SYNo. ofCores34579EMEAPart Code3XGSY4XGSY5XGSY7XGSY9XGSYAPACPart Code3X6SY4X6SY5X6SY7X6SY9X6SYNo. ofCores34579EMEAPart Code3XHSY4XHSY5XHSY7XHSY9XHSYAPACPart Code3X10SY4X10SY5X10SY7X10SY9X10SYEMEAPart Code3XJSY4XJSY5XJSY7XJSYAPACPart Code3X25SY4X25SY5X25SY7X25SYNom. OverallDiameter (mm)14.916.217.719.323.5Copper or 16.00 mm2No. ofCores345712Nom. OverallDiameter (mm)21.423.626.128.4Copper Weight(kg/km)460.50614.00768.001,075.00Nom. OverallDiameter (mm)18.019.821.723.729.1Copper or 25.00 mm2EMEAPart Code3XISY4XISY5XISY7XISYAPACPart Code3X16SY4X16SY5X16SY7X16SYNo. ofCores3457Nom. OverallDiameter (mm)25.928.631.233.9 Putup length & tolerance of the cables will vary depending on the construction of the cable MOQ will vary depending on the construction of the cable & provided at the time of quotation Cable requested outside the above design criteria can be reviewed and quotedCopper Weight(kg/km)720.00960.001,200.001,680.00

MachFlex 375 YY CablesUnshielded PVC Control CablesApplicationsDesigned for applications which are installed in occasional flexing and fixed locations. Cableapplications include precision control sensors, multi axis control machines, temperaturecontrollers, control panels, machine cutting tools, auxiliary equipment, motor speed control,production machinery and many more.General Reference Standards DIN VDE 0295, IEC 60228, BS6360DIN EN 50290-2-22, DIN VDE 0207-363-4-1IEC 60227-5DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2RoHS, REACH & CE DirectivesConstruction and Performance1.Conductor MaterialStranded bare copper (DIN VDE 0295 Class 5)2.Insulation Material & ColorPVC (polyvinyl chloride). A) Up to 5 cores: color-coded.From 6 cores: Belden MachFlex Color code. B) G with GN-YE protectiveconductor; X without protective conductor.3.Braid Shield MaterialTinned Copper Braid Shield4.Jacket / Sheath MaterialPVC (polyvinyl chloride)5.Flame RetardancyVDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-26.Voltage Rating (Uo/U)Up to 1.5 mm2: 300 / 500 VFrom 2.5 mm2: 450 / 750 V7.Oil ResistantDIN EN 50290-2-22 (TM54)8.Temperature Range-5 C TO 70 C (Occasional movement)-40 C TO 80 C (Fixed installation)9.Bending Radius10 x OD (Occasional movement)4 x OD (Fixed installation)10.Other PropertiesGood UV resistance, chemical resistance & flexibility13

MachFlex 375 YY Unshielded PVC Control CablesUNSHIELDED CABLE WITH (G) PROTECTIVE GROUND1 Conductor2 Insulation3 Sheath3Nom. OverallDiameter (mm)5.15.66.26.89.111.4DIN VDE 0295, IEC 60228, BS6360DIN EN 50290-2-22, DIN VDE 0207-363-4-1DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2RoHS, REACH & CE Directives12Conductor 0.50 mm2No. ofCores34571220 Conductor 0.75 mm2Copper t CodeC3GAC4GAC5GAC7GAC12GAC20GAAPACPart r 1.00 mm2No. ofCores34571220Nom. OverallDiameter (mm)5.66.26.87.510.112.7Copper rt CodeC3GBC4GBC5GBC7GBC12GBC20GBAPACPart nductor 1.50 mm2No. of Nom. OverallCopper WeightCores Diameter 0.9115.002013.8192.00Conductor 2.50 mm2EMEAPart CodeC3GCC4GCC5GCC7GCC12GCC20GCAPACPart CodeC3G1.0C4G1.0C5G1.0C7G1.0C12G1.0C20G1.0No. of Nom. OverallCopper WeightCores Diameter 12.0173.002015.1288.30Conductor 4.00 mm2EMEAPart CodeC3GDC4GDC5GDC7GDC12GDC20GDAPACPart CodeC3G1.5C4G1.5C5G1.5C7G1.5C12G1.5C20G1.5No. of Nom. OverallCopper WeightCores Diameter 00916.6216.001218.1288.00Conductor 6.00 mm2EMEAPart CodeC3GEC4GEC5GEC7GEC9GEC12GEAPACPart CodeC3G2.5C4G2.5C5G2.5C7G2.5C9G2.5C12G2.5No. of Nom. OverallCopper WeightCores Diameter 69.00919.3345.901221.0461.00Conductor 10.00 mm2EMEAPart Code3GF4GF5GF7GFC9GFC12GFAPACPart CodeC3G4C4G4C5G4C7G4C9G4C12G4No. ofCores34579EMEAPart CodeC3GGC4GGC5GGC7GGC9GGAPACPart CodeC3G6C4G6C5G6C7G6C9G6No. ofCores34579EMEAPart CodeC3GHC4GHC5GHC7GHC9GHAPACPart CodeC3G10C4G10C5G10C7G10C9G10EMEAPart CodeC3GJC4GJC5GJAPACPart CodeC3G25C4G25C5G25Nom. OverallDiameter (mm)12.814.215.817.421.9Copper or 16.00 mm2No. ofCores34514Nom. OverallDiameter (mm)19.621.924.3Copper Weight(kg/km)460.50614.00768.00Nom. OverallDiameter (mm)15.317.119.021.026.4Copper or 25.00 mm2EMEAPart CodeC3GIC4GIC5GIAPACPart CodeC3G16C4G16C5G16No. ofCores345Nom. OverallDiameter (mm)22.324.927.7 Putup length & tolerance of the cables will vary depending on the construction of the cable MOQ will vary depending on the construction of the cable & provided at the time of quotation Cable requested outside the above design criteria can be reviewed and quotedCopper Weight(kg/km)720.00960.001,200.00

MachFlex 375 YY Unshielded PVC Control CablesUNSHIELDED CABLE WITHOUT (G) PROTECTIVE GROUND1 Conductor2 Insulation3 Sheath3Nom. OverallDiameter (mm)5.15.66.26.89.111.4DIN VDE 0295, IEC 60228, BS6360DIN EN 50290-2-22, DIN VDE 0207-363-4-1DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2RoHS, REACH & CE Directives12Conductor 0.50 mm2No. ofCores34571220 Conductor 0.75 mm2Copper t CodeC3XAC4XAC5XAC7XAC12XAC20XAAPACPart r 1.00 mm2No. ofCores34571220Nom. OverallDiameter (mm)5.66.26.87.510.112.7Copper rt CodeC3XBC4XBC5XBC7XBC12XBC20XBAPACPart nductor 1.50 mm2No. of Nom. OverallCopper WeightCores Diameter 0.9115.002013.8192.00Conductor 2.50 mm2EMEAPart CodeC3XCC4XCC5XCC7XCC12XCC20XCAPACPart CodeC3X1.0C4X1.0C5X1.0C7X1.0C12X1.0C20X1.0No. of Nom. OverallCopper WeightCores Diameter 12.0173.002015.1288.30Conductor 4.00 mm2EMEAPart CodeC3XDC4XDC5XDC7XDC12XDC20XDAPACPart CodeC3X1.5C4X1.5C5X1.5C7X1.5C12X1.5C20X1.5No. of Nom. OverallCopper WeightCores Diameter 00916.6216.001218.1288.00Conductor 6.00 mm2EMEAPart CodeC3XEC4XEC5XEC7XEC9XEC12XEAPACPart CodeC3X2.5C4X2.5C5X2.5C7X2.5C9X2.5C12X2.5No. of Nom. OverallCopper WeightCores Diameter 69.00919.3345.901221.0461.00Conductor 10.00 mm2EMEAPart CodeC3XFC4XFC5XFC7XFC9XFC12XFAPACPart CodeC3X4C4X4C5X4C7X4C9X4C12X4No. ofCores34579EMEAPart CodeC3XGC4XGC5XGC7XGC9XGAPACPart CodeC3X6C4X6C5X6C7X6C9X6No. ofCores34579EMEAPart CodeC3XHC4XHC5XHC7XHC9XHAPACPart CodeC3X

4. Flame Retardancy VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 5. Voltage Rating (Uo/U) Up to 1.5 mm2: 300 / 500 V From 2.5 mm2: 450 / 750 V 6. Oil Resistant DIN EN 50290-2-22 (TM54) 7. Temperature Range-30 C TO 70 C (Occasional movement)-40 C TO 80 C (Fixed installation) 8

Related Documents:

product range l.v. pvc & xlpe power cables with copper and aluminium conductor l.v. pvc & xlpe control cables with copper conductor m.v. power cables upto 33 kv ehv cables from 66kv to 220kv m.v. / l.v. aerial bunched cables (abc) zero halogen cables fire survival cables (fs) instrumentation cables screened / unscreened industrial braided cables

M 337 COAXIAL CABLES Description Properties Page RG-Coaxial Cables 338 RG-Coaxial Cables 339 RG-Coaxial Cables 340 Halogen-Free RG-Coaxial Cables 341 CATV-Cables 342 SAT-Coaxial Cables up to 2150 MHz, for satellite-receivers, double screened 343 Multimedia-Coaxial Cables SAT 1,0/4,6GH, up to 2400MHz, for digital-tv, double screened,

TABLE OF CONTENTS VITALink Circuit Integrity Solutions VITALink MC & RC90 Transit Cables VITALink 300 RHW-2 & RW90 Cables VITALink Armored Cables VITALink Ethernet C bles VITALink Du l R ted CI/CIC C bles Splicing Capabilities Firewall Sign l, Power, & Instrument tion Solutions Firewall LSZH Signal Cables Firewall LSZH CCW Cables Firewall XHHW-2/RW90 Cables

Power cables inStrum Fire300 329 Control cables inStrum Fire330 369 Signal and data transmission cables inStrum Fire370 399 Extension and compensating cables inTherm 10 49 inTherm NF50 99 General and technical information Instrumentation cables Halogen-free instrumentation cables Fire-resistant instrumentation cables

HT-XLPE CABLES Main Features HT-XLPE Cables have longer life as compared to conventional PVC Cables HT-XLPE Cables have a higher conductor temperature rating i.e. 900C HT-XLPE Cables have a higher emergency overload capacity 1300C Max. temperature limit under short circuit conditions for HT-XLPE Cables is 2500C.Hence XLPE

Instrumentation Cables. Stock types. Instrumentation- and control cables Thermocouple extension . and compensating cables Power cables (low and medium voltage) . In this way the 'instrumentation cables' are invented again and again with all corresponding consequences of loss of economic viability, clearness,

765 S MEDIA TECHNOLOGY Designation Properties Page Audio Audio cables with braided shielding 766 Audio Audio cables, multicore with braided shielding 767 Audio Audio cables with foil shielding, single pair 768 Audio Audio cables, multipaired with foil shielding 769 Audio Audio cables, multipaired, spirally screened pairs and overall braided shielding 770 Audio Digital audio cables AES/EBU .

Additif alimentaire : substance qui n’est habituellement pas consommée comme un aliment ou utilisée comme un ingrédient dans l’alimentation. Ils sont ajoutés aux denrées dans un but technologique au stade de la fabrication, de la transformation, de la préparation, du traitement, du conditionnement, du transport ou de l’entreposage des denrées et se retrouvent donc dans la .