Synchronous motors combining reluctanceand permanent magnetsHigh efficiency motorsInterchangeable and compact versionsVariable speedFrame sizes from 132 to 355Power from 11 to 430 kWSpeeds from 1500 min-1 to 6000 min-1

Dyneo Synchronous motors combining reluctance and permanent magnetsThis catalogue presents the synchronous motors combining reluctance and permanent magnets of the Dyneo range,in all their efficiency classes and construction shapes.Dyneo motors are designed to be only driven by a variable speed drive while allowing a very high efficiency level.Nidec Leroy-Somer reserves the right to modify the characteristics of its products at any time in order toincorporate the latest technological developments. The information contained in this document is thereforeliable to be changed without notice.2Dyneo Synchronous motors combining reluctance and permanent magnets - 5729 en - 2020.03 / a

Dyneo Synchronous motors combining reluctance and permanent magnetsContentsGENERAL INFORMATION. 5Dyneo range. 5Quality commitment. 6Directive and standards relating to motor efficiency. 7Standards and approvals. 8Main product markings. 8ENVIRONMENT. 9Indexes of protection of electrical equipment enclosures. 9Environmental limitations. 10Impregnation and enhanced protection.11Painting. 12Interference suppression and protection of people. 13CONSTRUCTION. 14Mountings and positions. 14Connection to the drive - Motor connection. 15Radial loads. 16Cooling. 17Bearings and bearing life. 20OPERATION. 22Duty cycle. 22Insulation class. 23Temperature rise and thermal reserve. 23Dyneo motor selection. 24Noise level. 27Vibration. 28Maximum mechanical speed. 29Thermal protections. 30NAMEPLATES. 31Nameplate symbol definition. 31COMMERCIAL DESIGNATION. 32ELECTRICAL AND MECHANICALCHARACTERISTICS. 33Aluminium motor description (LSHRM). 33Steel motor description (PLSHRM). 33Cast iron motor description (FLSHRM). 34Key of interchangeable and compact version characteristictables. 35Interchangeable version - aluminium housing : LSHRM. 36Interchangeable version - cast iron housing : FLSHRM. 40Compact version - aluminium housing : LSHRM. 44Compact version - aluminium or steel housing : LSHRM /PLSHRM. 46Shaft extensions. 50Foot mounted dimensions IM 1001 (IM B3). 51Foot and flange mounted dimensions IM 2001 (IM B35). 52Flange mounted dimensions IM 3001* - IM 3011 (IM B5* IM V1). 53Specific dimensions of PLSHRM 315LD in position IM 2001(IM B35). 54Lifting ring position. 54Recommended bearing protections. 56Bearings and greasing. 58Description of terminal boxes. 60OPTIONAL EQUIPMENTS. 63Drip cover. 63Position sensors. 63Forced ventilation. 64UNITS OF MEASUREMENT AND STANDARDFORMULAE. 65Electricity and electromagnetism. 65Thermodynamics. 66Noise and vibration. 66Dimensions. 66Mechanics. 67Dyneo Synchronous motors combining reluctance and permanent magnets - 5729 en - 2020.03 / a3

Dyneo Synchronous motors combining reluctance and permanent magnetsContentsUNIT CONVERSIONS. 68STANDARD FORMULAE USED IN ELECTRICALENGINEERING. 69Mechanical formulae. 69Electrical formulae. 70TOLERANCE ON MAIN PERFORMANCEPARAMETERS. 71Tolerances of electromechanicalcharacteristics. 71Tolerances and adjustments. 71CONFIGURATOR. 72DECLARATION OF CONFORMITY ANDINCORPORATION. 734Dyneo Synchronous motors combining reluctance and permanent magnets - 5729 en - 2020.03 / a

Dyneo Synchronous motors combining reluctance and permanent magnetsGeneral informationDYNEO RANGENidec Leroy-somer has developed theDyneo range of high performancesynchronousmotorscombiningreluctance and permanent magnets.The technology used combines theproven performance of permanentmagnets with the simplicity of use ofinduction motors.Dyneo motors based on IMfinity platform, are designed to be controlledby a variable speed drive. They havebeen qualified and optimized withNidec Leroy-Somer drives to guaranteeoptimum electrical and mechanicalperformance and easy commissioning.Their high efficiency level (according toIEC 60034-30-2 standard) associatedwith the undeniable benefits of variablespeed control, contributes considerablyto reducing the energy bill.Dyneo range is available in 2 versions:- INTERCHANGEABLE Aluminium or cast iron housing, 1500 and 3000 rpmspeed ranges, IEC standard dimensions andpower equivalent to standardinduction motors.- COMPACT Aluminium or steel housing, 1500, 1800, 2600, 3000, 3600,4500 and 6000 rpm speed ranges, Performances and dimensionsoptimized for a high power toweight ratio.APPLICATION SYSTEMIZBy simply reading the QR code on thenameplate, the Systemiz applicationdisplays all useful Dyneo information,such as motor characteristics,commissioning and maintenancemanuals or certificates, which can beconsulted on any device (computer ,tablet, smartphone). The Systemizapp is available on all iOS, Android orWindows PC platforms.LSHRM315MPN 686251C19 001Smart tool for yourMotors & Drives*Support digital pour moto-variateurMoteurs Leroy-Somer CS1001516915 Angoulême Cedex 9 - FranceLSRPM 280 MRCN Numéro sérieSmart tool for yourMotors & DrivesProduct LibraryMotor DataProduct Library Motor Data Powerdrive MD SmartInterface Dyneo Synchronous motors combining reluctance and permanent magnets - 5729 en - 2020.03 / a5

Dyneo Synchronous motors combining reluctance and permanent magnetsGeneral informationQUALITY COMMITMENTNidec Leroy-Somer’s quality management system is based on:- Control of procedures right from theinitial sales offering until delivery to thecustomer,includingdesign,manufacturing start-up and production- A total quality policy based on makingcontinuous progress in improvingoperational procedures, involving alldepartments in the company in order togive customer satisfaction as regardsdelivery times, conformity and cost- Indicators used to monitor procedureperformance- Corrective actions and advancementswith tools such as FMECA, QFD,MAVP, MSP/MSQ and Hoshin typeimprovement workshops on flows,process re-engineering, plus LeanManufacturing and Lean OfficePersonnel are trained and take part inanalyses and actions for continuousimprovement of our procedures.- Annual surveys, opinion polls andregular visits to customers in order toascertain and detect their expectations.Nidec Leroy-Somer has entrusted the certification of its expertise to various international organisations.Certification is granted by independent professional auditors, and recognises the high standards of the company’s qualityassurance procedures. All activities resulting in the final version of the machine have therefore received official certification ISO9001: 2015 from the DNV. Similarly, our environmental approach has enabled us to obtain certification ISO 14001: 2015.Products for particular applications or those designed to operate in specific environments are also approved or certified by thefollowing organisations: LCIE, DNV, INERIS, EFECTIS, UL, BSRIA, TUV, GOST, which check their technical performanceagainst the various standards or recommendations.FICATIONRTIDCEISO E120 40615ISO 9001 : 2015TALENEMENVIRONEMESTNYS 01 :Dyneo Synchronous motors combining reluctance and permanent magnets - 5729 en - 2020.03 / a

Dyneo Synchronous motors combining reluctance and permanent magnetsGeneral informationDIRECTIVE AND STANDARDS RELATING TO MOTOR EFFICIENCYThere have been a number of changesto the standards and new standardscreated in recent years. They mainlyconcern motor efficiency and their scopeincludes measurement methods andmotor classification.Regulations are gradually beingimplemented, both nationally andinternationally, in many countries inorder to promote the use of highefficiency motors (Europe, USA,Canada, Brazil, Australia, New Zealand,Korea, China, Israel, etc.).The new generation of synchronousmotors combining reluctance andpermanent magnets responds tochanges in the standards as well as thelatest demands of system integratorsand users.IEC 60034-30-2 STANDARDThe IEC 60034-30-2 defines efficiencyclasses for rotating electrical machinesnot covered by the IEC 60034-30-1standard.This technical specification refers to theefficiency classification of AC motordesigned for variable voltage /frequency use, i.e. induction motors andsynchronous motors not covered byIEC 60034-30-1 (not designed to bepowered by mains supply).By extension and consistency, NidecLeroy-Somer has chosen to respect thisstandard for PLSHRM motors althoughtheoretically not covered.Sphere of application: Nominal voltage Un from 50 V to1 kV Nominal power Pn from 0.12 kW to1 000 kW Nominal speed Nn from 600 rpm to6000 rpm whatever the number ofmagnetic poles Designed for cooling modes IC410,IC411, IC416, or IC418 according toIEC 60034-6 Capable of continuous operation atits rated operating point (torque /power, speed) with a temperatureincrease in the specified insulationtemperature class Dimensioned for any ambienttemperature in the range –20 C to 60 C;Motors not concernedMotors designed to be powered bymains supply.ErP DIRECTIVE (EnergyRelated Product) 2009/125/EC(21ST OCTOBER 2009)It establishes a framework for settingthe eco-design requirements to beapplied to “energy-using products”.These products are grouped in lots.Motors come under lot 11 of the ecodesign program, as do pumps, fans andcirculating pumps.DECREE IMPLEMENTING OFTHE ErP EUROPEANREGULATION (EnergyRelated Product) EC/640/2009 AMENDEMENT EU/4/2014Motors not concerned:- Motors designed to operate whenfully submerged in liquid- Motors which are fully integrated inanother product (rotor/stator)- Motors with duty other thancontinuous duty- Motors designed to operate in thefollowing conditions: altitude 4000 m ambient air temperature 60 C maximum operating temperature 400 C ambient air temperature -30 C or 0 C for water-cooled motors safety motors conforming to directiveATEX 2014/34/UE brake motors.This is based on standard IEC 6003430-2 and will define the efficiencyclasses. It specifies the efficiency levelsto be attained for machines sold in theEuropean market and outlines thetimetable for their StandardIE2HighIE3PremiumIE4Super PremiumIE5*Ultra Premium* Motor dedicated to variable speed onlyThis standard only defines efficiencyclasses and their conditions. It is thenup to each country to define theefficiency classes and the exact scopeof application.Motors concerned:3-phase motors from 0.75 to 375 kWwith 2, 4 and 6 poles.Obligation to place High efficiency orPremium efficiency motors on themarket:- IE2 Class from 16 June 2011- IE3 Class from 1st January 2015 forpower ratings from 7.5 to 375 kW- IE3 Class from 1st January 2017 forpower from 0.75 to 375 kWDyneo Synchronous motors combining reluctance and permanent magnets - 5729 en - 2020.03 / a7

Dyneo Synchronous motors combining reluctance and permanent magnetsGeneral informationSTANDARDS AND APPROVALSstaReferenceIEC 60034-1ely with ths comp this catalogrtoomTheed inmentionndardsInternational standardsEN 60034-1Electrical rotating machines: ratings and operating characteristicsIEC 60034-2-1IEC 60034-2-3Electrical rotating machinesParty 2: methods for determining losses and efficiency from tests (excluding machines for traction vehicles)IEC 60034-5EN 60034-5Electrical rotating machines: classification of degrees of protection provided by casings of rotating machinesIEC 60034-6EN 60034-6Electrical rotating machines (except traction): cooling methodsIEC 60034-7EN 60034-7Electrical rotating machines (except traction): symbols for mounting positions and assembly layoutsIEC 60034-8Electrical rotating machines: terminal markings and direction of rotationIEC 60034-9EN 60034-9Electrical rotating machines: noise limitsIEC 60034-14EN 60034-14Electrical rotating machines: mechanical vibration of certain machines with shaft heights 56 mm and higher.Measurement, evaluation and limits of vibrational intensityIEC TS/60034-30-2Electrical rotating machinesEfficiency classes of variable speed AC motors (IE-code)IEC 61800-9-2Adjustable speed electrical power drive systemsPart 9-2: Ecodesign for power drive systems, motor starters, power electronics and their driven applications - Energyefficiency indicators for power drive systems and motor startersIEC 60038IEC standard voltagesIEC 60072Dimensions and power series for electrical rotating machines: designation of casings between 56 and 400 and flangesbetween 55 and 1080IEC 60085Evaluation and thermal classification of electrical insulationIEC 60721-2-1Classification of natural environment conditions. Temperature and humidityIEC 60204-1Safety of machinery - Electrical equipment of machines - Part 1: General requirementsIEC 60445Basic and safety principles for man-machine interface, marking and identification - Identification of equipment terminals,conductor terminations and conductorsIECC61800-3USElectromagnetic compatibility (EMC) : environmentIEC 106 guideGuidelines on the specification of environmental conditions for the determination of operating characteristics of equipmentISO 281Bearings - Basic dynamic loadings and nominal bearing lifeCISO 1680USEN 21680Acoustics - Test code for measuring airborne noise emitted by electrical rotating machines:a method for establishing an expert opinion for free field conditions over a reflective surfaceEN 50102Degree of protection provided by electrical housings against extreme mechanical impactsISO 8821Mechanical vibration - Balancing. Conventions on shaft keys and related partsISO 12944-2CCorrosion protection.USUSMAINCPRODUCTMARKINGSeeDyneo range is available with CE, cURus and EAC markings.CCCC8USUSUSeeThis marking is mandatory throughout the European Economic Community. It means that the product conforms to all the relevantdirectives. If the product does not conform to a relevant directive, it cannot be CE rated and cannot therefore bear the CE mark.The UL Recognized Component Mark, which is optional, indicates conformance with Canadian requirements and those of the UnitedStates. UL encourages manufacturers distributing products bearing the UL Recognized Component Mark for both countries to use thiscombined mark.The EAC mark replaces the GOST mark. It is the equivalent of the CE mark for the European Union market. This new mark coversregulations for Russia, Kazakhstan and Belarus. All products marketed in these three countries must bear this marking.USDyneo Synchronous motors combining reluctance and permanent magnets - 5729 en - 2020.03 / a

Dyneo Synchronous motors combining reluctance and permanent magnetsEnvironmentINDEXES OF PROTECTION OF ELECTRICAL EQUIPMENT ENCLOSURESAccording to IEC 60034-5 - EN 60034-5 (IP) - IEC 62262 (IK)TestsNo protectionØ 50 mm1Ø 12 mm2Ø 2.5 mm3Ø 1 mm4Definition5Protected againstsolid objects largerthan 50 mm (e.g.accidental contactwith the hand)Protected againstsold objects largerthan 12 mm(e.g. a finger)Protected againstsolid objects largerthan 2.5 mm(e.g. tools, wires)Protected againstsolid objects largerthan 1 mm(e.g. thin tools,small wires)Protected againstdust (no depositsof harmful material)6Protected againstany dust penetrationIP0TestsNo protectionProtected againstwater drops fallingvertically(condensation)115 23 6045Protected againstrain falling at up to60 from the vertical03Protected againstprojected waterfrom all directions0467Protected against theeffects of immersionbetween 0.15 and 1 m.mIP : Index of Protection5. : Machine protected against dust and accidental contact.Test result: no dust enters in harmful quantities, no risk ofProtected againstprolonged effectsof immersion underpressureTestsDefinitionNo protection150 g0102Protected againstprojected watercomparable to bigwaves8.mIK00Protected againstwater drops fallingat up to 15 from theverticalProtected against jetsof water from alldirections from a hoseExample :: Example of an IP 55 machineDefinition1mIP03rd digitmechanical protection2nd digitprotection against liquids0.15 m1st digit:protection against solid materials10 cmImpact energy:0.15 J10 cmImpact energy:0.20 J15 cmImpact energy:0.37 J20 cmImpact energy:0.50 J20 cmImpact energy:0.70 J40 cmImpact energy:1J40 cmImpact energy:2J40 cmImpact energy:5J40 cmImpact energy:10 J40 cmImpact energy:20 J200 g250 g250 g350 g0506070809250 g0.5 kg1.25 kg2.5 kgdirect contact with rotating parts. The test will last for 2 hours.5 : Machine protected against jets of water from all directionsfrom hoses at 3 m distance with a flow rate of 12.5 l/min at 0.3 bar.105 kgThe test will last for 3 minutes.Test result: no damage from water projected onto the machineLSHRM and FLSHRM motor types have a IP55 protection and PLSHRM a IP23 protection.Dyneo Synchronous motors combining reluctance and permanent magnets - 5729 en - 2020.03 / a9

Dyneo Synchronous motors combining reluctance and permanent magnetsEnvironmentENVIRONMENTAL LIMITATIONSNORMAL OPERATINGCONDITIONSAccording to 60034-1, motors canoperate in the following conditions:Correction coefficient tableNB: The output power can only be corrected upwards once the ability of the motor to start the loadhas been checked.Alt 4 000 mP1 / P ambient temperature within the range-20 C to 50 C (to 45 C for compactversion), altitude less than 1000 m, atmospheric pressure:1050 hPa (mbar) (750 mm Hg)Alt 3 000 mAlt 2 000 mAlt 1000 m0,80,9Power correction factorFor starting, see the commissioning andinstallation manual ref.5511Ta 10 CTaTa 20 C1,1Plated ambient temperature (Ta): Interchangeable version: 50 C or compact one: 45 C%In temperate climates, relative humidity is generally between 50 and 70%. For the relationshipbetween relative humidity and motor impregnation, especially where humidity and temperatureare high, see table on next page.100g / com).RELATIVE AND ABSOLUTEHUMIDITYTa - 10 C8020Machines should be stored at anambient temperature between -16 Cand 80 C for aluminium motors,between -40 C and 80 C for cast ironmotors, and at a relative humidity of lessthan 90%.Ta - 20 Cmetertemperature CNORMAL STORAGECONDITIONST amb ( C)1Absolute air humidityFor operating conditions outside theselimits, apply the power correctioncoefficient shown in the chart on theright while maintaining the thermalreserve, as a function of the altitude andambient temperature.25ormthelb20utbWe1510105MEASURING THE HUMIDITYHumidity is usually measured by the“wet and dry bulb thermometer”method. Absolute humidity, calculatedfrom the readings taken on the twothermometers, can be determined usingthe chart on the right. The chart alsoprovides relative humidity figures.To determine the humidity correctly, agood air flow is required for stablereadings, and accurate readings mustbe taken on the thermometers.During the construction of aluminiummotors, the materials of the variouscomponents which are in contact withone another are selected so as tominimize deterioration by galvaniceffect. The voltages in the metalcombinations used (cast iron-steel; castiron-aluminium; steel-aluminium; steeltin) are too low to cause deterioration.10 C10DRAIN HOLES203040Ambient temperature – dry bulb thermometerHoles are provided at the lowest pointsof the enclosure, depending on theoperating position (IM, etc.) to drain offanymoisturethatmayhaveaccumulated inside during cooling ofthe machine.The holes may be sealed with plasticplugs in standard. On request, they canbe sealed with screws, siphon or plasticventilator.Under certain special conditions, it isadvisable to leave the drain holespermanently open (operation inenvironments with high levels ofcondensation). Opening the holesperiodically should be part of the regularmaintenance procedure.DRIP COVERS5060For machines operating outdoors, withthe drive shaft downwards, drip coversare recommended.This is an option and should bespecified on the order if required.Dyneo Synchronous motors combining reluctance and permanent magnets - 5729 en - 2020.03 / a

Dyneo Synchronous motors combining reluctance and permanent magnetsEnvironmentIMPREGNATION AND ENHANCED PROTECTIONNORMAL ATMOSPHERICPRESSURE (750 MM HG)IINFLUENCE OFATMOSPHERIC PRESSUREThe table below shows the methods ofmanufacture suited to environments inwhich temperature and relative humidityshow large degrees of variation (seerelativeandabsolutehumiditycalculation method, on precedingpage).As atmospheric pressure decreases, airparticles rarefy and the environmentbecomes increasingly conductive.- P 550 mm Hg:standard impregnation according toprevious table - Possible derating orforced ventilation.The protection of the winding isgenerally described by the term“tropicalization”.- P 200 mm Hg:Coating of bearings - Flying leads up toa zone at P 750 mm Hg - Derating totake account of insufficient ventilation Forced ventilation.T : TropicalizationTC: Complete Tropicalization- P 200 mm Hg: Special manufacturebased on specification.For high humidity environments, werecommend that the windings are preheated (see space heaters in sectionhereafter).In all cases, these problems should beresolved by a special contract workedout on the basis of a specification.SPACE HEATERSSevere climatic conditions, e.g. T amb - 40 C, RH 95% etc, may require theuse of space heaters (fitted to one ortwo winding end coils) which serve tomaintain the average temperature ofthe motor, provide trouble-free starting,and/or eliminate problems caused bycondensation (loss of insulation).The heater supply wires are brought outto a terminal block in the motor terminalbox.The heaters must be switched off whilethe motor is running.Space heater values are given insection Optional equipments page63.Tropicalization choiceRelativehumidityHR 95 %HR 95 % 1θ - 40 Cask for estimate (quotation)ask for estimate (quotation)- 20 C à 50 CT StandardTC StandardOther ambient temperaturesask for estimate (quotation)ask for estimate (quotation)Plate markTTCAmbienttemperature range1. Atmosphere without high levels of condensationStandard impregnationDyneo Synchronous motors combining reluctance and permanent magnets - 5729 en - 2020.03 / a11

Dyneo Synchronous motors combining reluctance and permanent magnetsEnvironmentPAINTINGSurface protection is defined in the ISO 12944 standard. This standard defines the planned lifetime of a paint system until the firstmajor application of maintenance paint. Durability is not a guarantee.The EN ISO 12944 standard comprises 8 sections. Part 2 covers the classification of the environments.Nidec Leroy-Somer motors are protected with a range of surface finishes.The surfaces receive appropriate special treatments, as shown below.PREPARATION OF SURFACESSURFACEPARTSTREATMENTCast ironEnd shieldsShot blasting PrimerAccessoriesPhosphatization PrimerTerminal boxes - Fan coversElectrostatic painting or Epoxy powderAluminium alloyHousings - Terminal boxesShot blastingPolymerFan covers- Terminal boxesVentilation grillesNone, but must be free from grease, casting-mould coatingsand dust which would affect paint adhesionSteelCLASSIFICATION OF THE ENVIRONMENTSNidec Leroy-Somer painting systems according to the TYCATEGORYAS PER ISO 12944-2-OthersC3AVERAGEISO 6270ISO 9227Watercondensationnb hoursSalt mistnb HighVery Y HIGHC4M-P*HighVery hVery high720-1440--System descriptionWithout any coat except cast iron partsOne primer coat / Ph-Zn PuOne Polyurethane coatOne primer coat / Ph-Zn PuOne Polyurethane coatOne Primer coat / Ph-Zn PuOne Epoxy coatOne primer coat / Ph-Zn EpoxyOne middle coat Ph-Zn PuOne Polyester / Acrylic coat-: Standard for Dyneo motors.* For indoor onlyNidec Leroy-Somer standard paint color reference for Dyneo range:RAL 9005Paint brightness standard: Satin or gloss12Dyneo Synchronous motors combining reluctance and permanent magnets - 5729 en - 2020.03 / a

Dyneo Synchronous motors combining reluctance and permanent magnetsEnvironmentINTERFERENCE SUPPRESSION AND PROTECTION OF PEOPLEAIRBORNE INTERFERENCEEMISSIONFor standard motors, the housing actsas an electromagnetic screening,reducing electromagnetic emissionsmeasured at 0.25 meters from themotor to approximately 5 gauss (5 x10–4 T).However, electromagnetic emissionsmay be noticeably reduced by a specialconstruction of aluminium alloy endshields and a stainless steel shaft.IMMUNITYThe construction of motor housings(especially finned aluminium alloyframes)isolatesexternalelectromagnetic sources to the extentthat any field penetrating the casing andmagnetic circuit will be too weak tointerfere with the operation of the motor.POWER SUPPLYINTERFERENCEThe use of electronic systems forstarting, variable speed control or powersupply can create harmonics on thesupply lines which may interfere withthe operation of machines. Thesephenomena are taken into account indetermining the machine dimensions,which act as quenching chokes in thisrespect.The CISPR 11 standard definespermissible rejection and immunityrates.Three-phase squirrel cage machines donot in themselves produce interferenceof this type. Mains connectionequipment (contactors) may, however,need interference protection.APPLICATION OF DIRECTIVE2014/30/EC CONCERNINGELECTROMAGNETICCOMPATIBILITY (EMC)In the case the motor is supplied by adrive, the motor is only a sub-assemblyof a device which the system buildermust ensure conforms to the essentialrequirements of the EMC directives.APPLICATION OF LOWVOLTAGE DIRECTIVE2014/35/EUAll motors are subject to this directive.The main requirements concern theprotection of people, animals andproperty against risks caused byoperation of the motors (see thecommissioningandmaintenancemanual for precautions to be taken).APPLICATION OFMACHINERY DIRECTIVE2006/42/ECAll motors are designed to be integratedin a device subject to the machinerydirective.PRODUCT MARKINGThe fact that motors comply with theessential requirements of the Directivesis shown by the CE mark on theirnameplates and/or packaging anddocumentation.Dyneo Synchronous motors combining reluctance and permanent magnets - 5729 en - 2020.03 / a13

Dyneo Synchronous motors combining reluctance and permanent magnetsConstructionMOUNTINGS AND POSITIONS(according to IEC 60034-7 standard)Foot mounted motors all frame sizes(FF) flange mounted motors all frame sizes(except IM 3001, which is limitedto frame size 225 mm)(FT) face mounted motors all frame sizes 160 mmIM 1001 (IM B3)- Horizontal shaft- Feet on f

2 Dyneo Synchronous motors combining reluctance and permanent magnets Dyneo Synchronous motors combining reluctance and permanent magnets - 5729 en - 2020.03 / a This catalogue presents the synchronous motors combining reluctance and permanent magnets of the Dyneo range,

Related Documents:

SYNCHRONOUS RELUCTANCE MOTOR (SyRM) (or) SYNREL MOTOR The PM synchronous motor operates as a synchronous reluctance motor, if the magnets are left out or demagnetized .i.e. the synchronous reluctance motors do not have any field winding or permanent magnet on the rotor. The rotor has salien

Low voltage induction motors – IEC and NEMA High voltage induction motors Inverters Eddy current variable speed drives Drip proof motors – LV and HV DC motors Synchronous motors Vertical hollow shaft motors Hazardous area motors High efficiency motors Brake motor

Synchronous Reluctance Motor Utilizing Dual-phase Magnetic Material . Patel B. Reddy . General Electric; Global Research Center. Niskayuna, NY . . power density to induction motors [5], [8], [10], [12]-[13][14], low rotor losses and synchronous operation/simple control [6], [7], [11]. The key disadvantages of the SynRel machine are low .

In synchronous-reluctance motors, the speed is perfectly known due to the synchronous mode of operation. Precise speed is reached even without encoder. The system boasts with high dynamic perform

2 ABB / AMZ Synchronous Motors EN 08-2005 The Global Power in Synchronous Motors ABB is the world’s leading supplier of synchronous motors and generators, with more than a century of ex

Synchronous Motors are three-phase AC motors which run at synchronous speed, Synchronous motors have the following characteristics: A three-phase stator similar to that of an induction motor. Medium voltage stators are often used. A wound rotor (rotating field) which has the same number of poles as the

After executing hysteresis control, a switching pattern is selected to generate the required torque and flux of the motor. A closed-loop drive system is thus obtained. Although many papers discuss the direct torque control of induction motors [13]-[15], only a few papers study the direct torque control fo r synchronous reluctance motors.

The new ISO 14001:2015 standard explicitly expects organizations to identify and address risks affecting compliance of products and services, resulting in improved environmental performance. Besides identifying the risks, the new ISO standard expects organizations to address opportunities for improvements and corrective actions based on the risk analysis. Note that while corrective action is a .