MiSeq Software Release NotesPart Number: 15059913 Rev ARelease Date: September 15, 2014Page 1 of 5MiSeq SoftwareRelease NotesMCS 2.5RTA v1.18.54MiSeq Reporter 2.5BaseSpace Broker v2.1MiSeq Recipes 3.1.0For MiSeq SystemsSeptember 2014

MiSeq Software Release NotesPart Number: 15059913 Rev ARelease Date: September 15, 2014Page 2 of 5IntroductionThese Release Notes detail the key changes to software components for the MiSeq sincethe package containing MCS v2.4, MiSeq Reporter v2.4, RTA v.1.18.54, BaseSpaceBroker v2.1, and MiSeq Recipes v3.0. All of these pieces are contained within a newMiSeq Updater 2.5.0.For VeriSeq PGS workflow users, this release is required. For all other users, this releaseis optional, but highly recommended due to the features and bug fixes described inthese Release Notes. Please review these changes before updating your software.If you are upgrading from version 2.3 or earlier, please review the release notes for v2.4for a list of features and bug fixes introduced in that version.For more information about the MiSeq system and how to use the software included withit, please see the product and support pages at ing instruments/miseq.ilmnTo update this software suite, your MiSeq must already be running MiSeq versions 2.1,2.2 or 2.3. If you have an earlier MiSeq software version, you can update your softwareusing the MiSeq Updater 2.1, which can be found on the Illumina website.The software package includes: I.MiSeq Control Software (MCS) v2.5RTA v1.18.54 -- no change in this releaseMiSeq Reporter v2.5BaseSpace Broker v2.1 -- no change in this releaseMiSeq Recipes 3.1.0MiSeq Control Software (MCS) v2.5NEW FEATURES: Enabled VeriSeq PGS workflow. This workflow only proceeds with a VeriSeq PGSreagent cartridge and components. The system no longer checks for a BaseSpace connection if instrument health dataand BaseSpace analysis are disabled. Previously, MCS checked for a BaseSpaceconnection before starting every run. Added a new template line wash option to the post-run wash and manual wash. Thisoption is unselected by default, except in the case of a post-run wash for a VeriSeqworkflow run, where it is selected.oMCS now tracks whether a template line wash was included in the mostrecent post-run or manual wash.oIf a user attempts to run a VeriSeq workflow run, and a template line washwas not performed at the last wash, the user is warned and prompted to

MiSeq Software Release NotesPart Number: 15059913 Rev ARelease Date: September 15, 2014Page 3 of 5perform a template line wash. This warning does not apply to otherworkflows.DEFECT REPAIRS: A fix was made to ensure that run folder names are synchronized with run countvalues.KNOWN ISSUES: II. III.NoneRTA v1.18.54No changes were made to this application in this release.MiSeq Reporter v2.5NEW FEATURES: NoneDEFECT REPAIRS: 16S Metagenomics Workflow:o Amplicon-DS Workflow:o A fix was made to resolve an out of memory error occurring when the somaticvariant caller identifies a large number of indels. This issue has been resolvedand the out of memory condition no longer occurs in these situations.Enrichment:o A fix was made to a bug that could lead to suboptimal classification of readsat the species level. This bug impacts the assignment of some reads tospecies-level classification, in cases where there is little difference in theprobability scoring of the first and second most likely species classification.This fix improves the accuracy of read classification at the species level.A fix was made to resolve an error reporting gaps when there are no actualgaps, and the gaps.csv file is empty. This issue has been resolved.All Workflows:oA fix was made to prevent application crashes in the event of indexduplications on a given sample sheet. If a sample sheet with duplicateindexes is used, MiSeq Reporter now displays an error message to the user.oMiSeq Reporter no longer performs read stitching on index reads.oThe Somatic Variant Caller now calculates coverage of insertions & deletionsmore accurately than previous versions of MSR in regions with extremely highread depth. In this new MSR 2.5 version, unless the indel is on the edge of acoverage region, the reported depth will be the average of the coverage ofthe base before and after the indel. If the indel is at an edge (so coverage ismissing for either the base before or after) then the reported coverage will befor whichever one exists.

MiSeq Software Release NotesPart Number: 15059913 Rev ARelease Date: September 15, 2014Page 4 of 5KNOWN ISSUES: None

MiSeq Software Release NotesPart Number: 15059913 Rev ARelease Date: September 15, 2014Page 5 of 5CURRENT ALGORITHM VERSIONS:AlgorithmsVersionsWorkflowsAlignersBWA 0.6.1-r104-tpx(no change in this release)Banded Smith Waterman 2.5.1.3(was 2.4.60.8 in MiSeq Reporter2.4 release)Isaac 01.13.10.21(no change in this release)Somatic 3.5.2.1(was 3.2.3.0 in MiSeq Reporter 2.4release)GATK 1.6-22-g3ec78bd(no change in this release)Default for Enrichment, Library QC,PCR Amplicon, ResequencingTargeted RNA, TruSeq Amplicon,Amplicon-DSVariant CallersStarling 2.0.3(no change in this release)Samtools 0.1.18Tabix 0.2.5Zlib 1.25OtherIV. V.Optional for ResequencingOptional for PCR Amplicon,Resequencing, TruSeq AmpliconDefault for Amplicon-DSDefault for Enrichment, PCRAmplicon, Resequencing, TruSeqAmpliconOptional for ResequencingBaseSpace Broker v2.1No changes were made to this application in this release.MiSeq Recipes v3.1.0NEW FEATURES: Updated the standard MiSeq post-run wash and manual wash recipes to perform anoptional a template line wash if selected by the user. Added VeriSeq workflow recipes.DEFECT REPAIRS: NoneKNOWN ISSUES: None

MiSeq Software Release Notes Part Number: 15059913 Rev A Release Date: September 15, 2014 Page 3 of 5 perform a template line wash. This warning does not apply to other workflows.

Related Documents:

40 ng DNA 5% VAF 10 ng DNA MiniSeq Mid Output 2x150 16 0 0 MiniSeq High Output 2x150 50 0 1 MiSeq V2 2x150 30 0 1 MiSeq V3 2x300 50 0 1 MiSeq V2 Micro 2x150 8 0 0 MiSeq V2 Nano 2x150 2 0 0 NextSeq 500 Mid Output 2x150 260 2 6 NextSeq 500 High Output 2x150 800 5 19 HiSeq 2500 Rapid run SBS

Illumina MiSeq Wash Tray (n 2; recommended one for bleach washes, one for water washes only) 7.3. Lint-free wipes (Fisher Scientific, Cat# 06-666 or equivalent) 7.4. Lens paper (Fisher Scientific, Cat# 11-996 or equivalent) 7.5. MiSeq wash tubes (Contact Illumina for information on obtaining

Consult the MiSeq System User Guide for additional materials required to use Illumina MiSeq instrument. Reagents Consumables Equipment MiSeq Reagent Kit Nuclease-Free Water (Ambion AM9937) Round-bottom plates (Evergreen 290-8117-01R) qPCR instrument (ABI 7500 Series)† Choose one of

Corrected material number. Material # 20000262 Document # 15027617 v04 July 2018 Added new run configuration options for Local Run Manager, Sample Sheets, and Manual sequencing modes. Replaced references to MiSeq Reporter with Local Run Manager. Added Resolve Chiller Temperature Ranges to Troubleshooting Appendix. Material # 20000262 Document .

Guide,part#15031335). Document#15027617v05Material#20000262 . User-SuppliedConsumables 13 Chapter3Sequencing 15 Introduction 15 RunDuration 15 MiSeqWorkflow 17 ThawReagentCartridge 18 InspecttheReagentCartridge 19 DenatureandDiluteLibraries 19 . TheIllumina MiSeq .File Size: 1MB

FOR RESEARCH USE ONLY ILLUMINA PROPRIETARY Part # 15027617 Rev. H March 2013 MiSeq System User Guide

Chapter1 SystemOverview SystemOverview Introduction 6 InstrumentHardware 8 SystemSoftware 10 MiSeq

Annual Men’s Day Sunday, October 26, 2008 Order of Service Devotion Men’s Day Praise Team Responsive Reading Psalm 1 Congregational Singing This Little Light of Mine Selection Men’s Day Choir Altar Prayer Dance Selection Creations of God Announcements Bro. Robert Shields Pastoral Observations Message Rev. Jeffery A. Lang, Senior Pastor Southside Church & International Ministries Jackson .