VFC400 OperationInstructionsControl Solutions, Inc. 503-410-5996 support@vfcdataloggers.com1

Device and Buttons ActionsOverviewPressing the Review/Mark button will placethe logger in review mode.Pressing this button again while in reviewmode will allow you to review up to 30 daysof min/max temperatures.This action also places an inspectionmark in the log if recording is active.The inspection marks validate yourtwice daily temperature checks.The Start/Clear/Stop button hasmultiple functions:Press to start your recording.Press to stop your recording.Press to exit the day summary mode.Control Solutions, Inc. 503-410-5996 support@vfcdataloggers.com2

Starting the Logger#1The logger must be in Ready mode for it tobe started. The logger displays READY.Press and hold the Start/Clear/Stop button.STARTING is displayed in addition to READY. Ready will disappear Release the button when Ready disappears Starting will also disappear#2This check mark indicates noalarm#3REC appears indicating your logger isrecording temperature dataLogger not starting?Your logger will not start if You release the Start button before READY disappearsYou hold the button longer than 2 seconds after READY disappearsControl Solutions, Inc. 503-410-5996 support@vfcdataloggers.com3

The most recently recordedtemperature, 48 F, is displayed.This is updated at the same rate asthe logging interval.Reading theDisplayThe current time isshown in 24hr(military) format,1:29pm.An X is shown instead ofbecause there is an alarm.The alarm daysummary shows whenan alarm wasrecorded. indicates highalarmsThe number of days the loggerhas been recording is shownhere.Remember to download data ona regular schedule. Allowing thememory to become full will causeyour logger to stop recording.T indicates an alarmtoday-3 indicates an alarm3 days agoThis example shows the next day at 1:49amThe temperature hasreturned to anacceptable range butthe alarm statusremains.The temp is now within range however; the X remains andthe audible alarm will continue to sound until the data isdownloaded.The day summary has shifted by 1 day as the display time hasgone through midnight (00:00).-4 day and -1 day are displayed indicating an alarm occurred4 days ago and 1 day ago.Control Solutions, Inc. 503-410-5996 support@vfcdataloggers.com4

ReviewingDailyStatisticsOne press of the Review/Mark button puts the logger in reviewmode allowing you to view minimum/maximum (min/max)temperatures.Min/Max temps can only be viewed when the logger is in Recording or Stopped mode.Pressing the Review/Mark button again, shows thecurrent day’s maximum (max) temperature.Pressing Review/Mark button again displays theday’s minimum (min) temperature.“T” will flash (indicating Today) 00 Days is shown indicating ‘Today’Pressing Review/Mark a 3rd time showsyesterday's max temperature.Pressing the Review/Mark button a 4th timedisplays yesterday's min temperature.-1 flashes indicating yesterday -01 days is shown indicating “Yesterday”The logger will store and display 30 days of min/max temperatures.After pressing the review button if nothing is pressed for 30 seconds the regular display returns.Control Solutions, Inc. 503-410-5996 support@vfcdataloggers.com5

Stopping theLoggerStopping the logger prior todownloading is recommended.Press and hold the Start/Clear/Stop button for1-2 seconds. STOPPED will appear REC will disappear after 1-2 seconds Release the button when REC disappearsThe display will say STOPPED and show onlythe number of days collected.Now you can download your data. Take the logger to your PC Open the Control Solutions VTMC software(you can get the software here) Place the logger in the docking station todownload the dataControl Solutions, Inc. 503-410-5996 support@vfcdataloggers.com6

Questions aboutsoftwaredownload?Visit our support pageSend us an emailsupport@vfcdataloggers.comJump to:VFC400 InstallationVFC400 Software DownloadVFC400 Software Set UpVFC400 Logger ConfigurationData Logger OperationControl Solutions, Inc. 503-410-5996 support@vfcdataloggers.com7

The inspection marks validate your twice daily temperature checks. The Start/Clear/Stop button has multiple functions: Press to start your recording. Press to stop your recording. Press to exit th

Related Documents:

2 CR200-Series1 Dataloggers / Wireless Sensors 1Th e CR206, CR211, and CR216 dataloggers replaced the CR205, CR210, and CR215 dataloggers on September 15, 2005.Th e newer dataloggers refl ect changes incorporated in the RF401, RF411, and RF416 Spread Spectrum Radios, which replaced the RF400, RF410, and RF415 radios in

VFC Provider Enrollment Agreement These directions are intended to provide step-by-step instructions for completing the Vaccines for Children (VFC) Program’s annual re-enrollment, which is required for all participating VFC providers. 1. Click on the “VFC RE-ENROLLMENT FORMS”: 2.

2019-2020 VFC Program Protocols DHEC Immunization Division Rev. 3. 2019 Page 5 of 36 REQUIREMENT: VFC re-enrollment (provider agreement valid for 24 months) is required to continue in the program after initial enrollment. VFC provide

– VPDIP uses the numbers of VFC and non-VFC children in the practice to evaluate the appropriateness of VFC vaccine orders. Therefore, Provider Profile numbers are required to be reviewed and updated at least annually. A new practice that has not yet establis

Primary and Back-up VFC Coordinators must complete CDC’s . You Call the Shots. Modules 10 (Storage and Handling) & 16 (VFC Program) for the current year, OR participate in a VFC Compliance Site Visit with their Regional Immunization Representative in the past 12 months, OR participate in a VFC

These directions provide step-by-step instructions for completing the Vaccines for Children (VFC) Program’s annual re-enrollment, which is required for all participating VFC providers. Only IRIS Admin users have access to complete VFC re-enrollment. To add additional Admin Users, complete the

Data loggers will be provided to VFC providers during 2015 and 2016 compliance site visits. VFC field reviewer to setup for you Additional training to be done during visit Replacing digital thermometers given to you in 2013 and 2014. -Keep those as backup units (new CDC requirement)

In recent years, there has been an increasing amount of literature on . A large and growing body of literature has investigated . In recent years, several studies have focused on