IBM PowerVM Virtualization Introduction And Configuration

2y ago
79 Views
10 Downloads
7.09 MB
790 Pages
Last View : 2m ago
Last Download : 3m ago
Upload by : Tripp Mcmullen
Transcription

Front coverIBM PowerVM VirtualizationIntroduction and ConfigurationUnderstand PowerVM featuresand capabilitiesPlan, implement, and set upPowerVM virtualizationUpdated to include newPOWER7 technologiesMel CorderoLúcio CorreiaHai LinVamshikrishna ThatikondaRodrigo Xavieribm.com/redbooks

International Technical Support OrganizationIBM PowerVM Virtualization Introductionand ConfigurationJune 2013SG24-7940-05

Note: Before using this information and the product it supports, read the information in“Notices” on page xxi.Sixth Edition (June 2013)This edition applies to:Version 7, Release 1 of AIXVersion 7, Release 1 of IBM iVersion 2, Release 2, Modification 2, Fixpack 26 of the Virtual I/O ServerVersion 7, Release 7, Modification 6 of the HMCVersion AL730, release 95 of the POWER7 System FirmwareVersion AL740, release 95 of the POWER7 System Firmware Copyright International Business Machines Corporation 2004, 2013. All rights reserved.Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by GSA ADPSchedule Contract with IBM Corp.

ContentsFigures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiTables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xixNotices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxiTrademarks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxiiPreface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxiiiAuthors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxiiiNow you can become a published author, too! . . . . . . . . . . . . . . . . . . . . . . . xxviComments welcome. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxviStay connected to IBM Redbooks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xxviiSummary of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxixJune 2013, Sixth Edition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxixPart 1. Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Chapter 1. PowerVM technologies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.1 The value of PowerVM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41.2 What is PowerVM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41.2.1 New PowerVM features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61.2.2 PowerVM editions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71.2.3 Activating the PowerVM feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121.3 The POWER Hypervisor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151.4 Logical partitioning technologies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171.4.1 Dedicated LPAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171.4.2 Dynamic LPAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171.4.3 Micro-partitioning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Chapter 2. Processor virtualization overview. . . . . . . . . . . . . . . . . . . . . . . 192.1 Micro-partitioning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202.2 Shared-Processor Pools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212.3 Multiple Shared-Processor Pools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212.4 Shared dedicated capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Chapter 3. Memory virtualization overview . . . . . . . . . . . . . . . . . . . . . . . . 253.1 Active Memory Sharing overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263.2 Active Memory Deduplication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273.3 Active Memory Expansion overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Copyright IBM Corp. 2004, 2013. All rights reserved.iii

3.4 Active Memory Mirroring overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303.5 Memory virtualization technologies comparison . . . . . . . . . . . . . . . . . . . . 33Chapter 4. I/O virtualization overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 354.1 Virtual I/O Server overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374.1.1 Supported platforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 384.1.2 Virtual storage mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 384.1.3 Virtual I/O Server network security . . . . . . . . . . . . . . . . . . . . . . . . . . 434.1.4 Command line and cfgassist interface . . . . . . . . . . . . . . . . . . . . . . . 434.1.5 Hardware Management Console integration. . . . . . . . . . . . . . . . . . . 444.1.6 System Planning Tool support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 444.1.7 Integrated Virtualization Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . 444.1.8 Tivoli support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 444.1.9 Allowed third party applications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 464.1.10 Performance Toolbox support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 474.1.11 Virtual I/O Server Performance advisor . . . . . . . . . . . . . . . . . . . . . 474.2 Storage virtualization overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 474.2.1 Virtual SCSI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 484.2.2 Virtual Fibre Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 504.2.3 Virtual Optical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 524.2.4 Virtual Tape . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 524.2.5 Virtual Console (virtual TTY/console support). . . . . . . . . . . . . . . . . . 534.2.6 Availability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 534.2.7 Shared storage pools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 554.3 Network virtualization overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 614.3.1 Virtual Ethernet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 624.3.2 Virtual Ethernet adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 624.3.3 Virtual LAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 634.3.4 Virtual switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 644.3.5 Shared Ethernet Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 644.4 Platform consideration for I/O virtualization. . . . . . . . . . . . . . . . . . . . . . . . 664.4.1 I/O virtualization consideration for IBM i . . . . . . . . . . . . . . . . . . . . . . 664.4.2 I/O virtualization consideration for Linux . . . . . . . . . . . . . . . . . . . . . . 74Chapter 5. Server virtualization overview . . . . . . . . . . . . . . . . . . . . . . . . . . 795.1 Live Partition Mobility overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 805.2 Partition Suspend and Resume overview . . . . . . . . . . . . . . . . . . . . . . . . . 82Chapter 6. Management console overview . . . . . . . . . . . . . . . . . . . . . . . . . 856.1 Management console comparison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 866.2 Hardware Management Console. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 866.3 Integrated Virtualization Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 886.4 System Director VMControl. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88ivIBM PowerVM Virtualization Introduction and Configuration

Part 2. Plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91Chapter 7. PowerVM considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 937.1 System requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 947.1.1 Hardware requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 947.1.2 Licensing requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 977.1.3 Operating system requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 987.2 Availability planning for PowerVM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1007.2.1 Redundant Virtual I/O Servers . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1017.2.2 Live Partition Mobility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1027.2.3 PowerVM with PowerHA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1047.3 Security planning for PowerVM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1057.4 Management Console considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . 1077.4.1 Hardware Management Console (HMC) . . . . . . . . . . . . . . . . . . . . . 1077.4.2 Integrated Virtualization Manager (IVM) . . . . . . . . . . . . . . . . . . . . . 1087.4.3 IBM System Director VMControl . . . . . . . . . . . . . . . . . . . . . . . . . . . 108Chapter 8. Processor virtualization planning . . . . . . . . . . . . . . . . . . . . . . 1118.1 Micro-partitioning capacity planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1128.1.1 Processing units of capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1128.1.2 Capped and uncapped mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1138.1.3 Virtual processors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1148.1.4 Shared processor considerations . . . . . . . . . . . . . . . . . . . . . . . . . . 1178.2 Shared-Processor Pools capacity planning. . . . . . . . . . . . . . . . . . . . . . . 1198.2.1 Capacity attributes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1198.2.2 The default Shared-Processor Pool (SPP0 ) . . . . . . . . . . . . . . . . . . 1208.2.3 Server load and capacity examples . . . . . . . . . . . . . . . . . . . . . . . . 1228.2.4 Shared-Processor Pools scenarios . . . . . . . . . . . . . . . . . . . . . . . . . 1278.3 Software license in a virtualized environment . . . . . . . . . . . . . . . . . . . . . 1338.3.1 Licensing factors in a virtualized system . . . . . . . . . . . . . . . . . . . . . 1348.3.2 Capacity capping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1358.3.3 System with Capacity Upgrade on Demand processors . . . . . . . . . 1378.3.4 Summary of licensing factors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1378.3.5 IBM software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1388.3.6 Software licensing on IBM i. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1418.3.7 Linux operating system licensing . . . . . . . . . . . . . . . . . . . . . . . . . . 141Chapter 9. Memory virtualization planning. . . . . . . . . . . . . . . . . . . . . . . . 1439.1 Active Memory Sharing planning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1449.1.1 Active Memory Sharing prerequisites . . . . . . . . . . . . . . . . . . . . . . . 1449.1.2 Deployment considerations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1459.1.3 Sizing Active Memory Sharing . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1519.1.4 Usage examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1539.2 Active Memory Deduplication planning . . . . . . . . . . . . . . . . . . . . . . . . . . 157Contentsv

9.2.1 Checking the requirements for Active Memory Deduplication . . . . 1579.2.2 Sizing your systems for Active Memory Deduplication . . . . . . . . . . 165Chapter 10. I/O virtualization planning . . . . . . . . . . . . . . . . . . . . . . . . . . . 16710.1 Virtual I/O Server planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16810.1.1 Specifications required to create the Virtual I/O Server . . . . . . . . 16810.1.2 Redundancy considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17510.2 Storage virtualization planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18210.2.1 Virtual SCSI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18210.2.2 Virtual Fibre Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18910.2.3 Redundancy configurations for virtual Fibre Channel adapters . . 19310.2.4 Virtual SCSI and Virtual Fibre Channel comparison . . . . . . . . . . . 20010.2.5 Virtual optical devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20310.2.6 Virtual tape devices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20310.2.7 Availability planning for virtual storage . . . . . . . . . . . . . . . . . . . . . 20410.2.8 AIX LVM mirroring in the client partition . . . . . . . . . . . . . . . . . . . . 20610.2.9 IBM i mirroring in the client partition . . . . . . . . . . . . . . . . . . . . . . . 20810.2.10 Linux mirroring in the client partition . . . . . . . . . . . . . . . . . . . . . . 20810.2.11 Supported AIX client configurations . . . . . . . . . . . . . . . . . . . . . . 20910.2.12 Supported virtual SCSI configurations . . . . . . . . . . . . . . . . . . . . 20910.2.13 Shared storage pools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21910.3 Network virtualization planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22310.3.1 Virtual Ethernet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22310.3.2 Virtual LAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22310.3.3 Virtual switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22610.3.4 Shared Ethernet Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22910.3.5 Availability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23710.3.6 Using Link Aggregation on the Virtual I/O Server . . . . . . . . . . . . . 24910.3.7 QoS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25210.3.8 Performance considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255Chapter 11. Server virtualization planning . . . . . . . . . . . . . . . . . . . . . . . . 25711.1 Dynamic LPAR operations and dynamic resources planning . . . . . . . . 25811.1.1 Dedicated-processor partitions . . . . . . . . . . . . . . . . . . . . . . . . . . . 25811.1.2 Micro-partitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25811.1.3 Capacity on Demand. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25911.1.4 Planning for dynamic LPAR operations . . . . . . . . . . . . . . . . . . . . 26011.1.5 Performing dynamic LPAR operations . . . . . . . . . . . . . . . . . . . . . 26211.2 Live Partition Mobility planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26211.2.1 General requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26311.2.2 Migration capability and compatibility . . . . . . . . . . . . . . . . . . . . . . 26411.2.3 Readiness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26511.2.4 Migratability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265viIBM PowerVM Virtualization Introduction and Configuration

11.2.5 Infrastructure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26711.2.6 Virtual I/O Server. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27211.2.7 Live Partition Mobility using Virtual Fibre Channel . . . . . . . . . . . . 28311.2.8 Multiple concurrent migrations . . . . . . . . . . . . . . . . . . . . . . . . . . . 28811.2.9 Remote Live Partition Mobility. . . . . . . . . . . . . . . . . . . . . . . . . . . . 29011.2.10 Processor compatibility modes . . . . . . . . . . . . . . . . . . . . . . . . . . 29511.2.11 General considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29611.3 Suspend and Resume planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29911.3.1 Configuration requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29911.3.2 The Reserved Storage Device Pool . . . . . . . . . . . . . . . . . . . . . . . 30111.3.3 Suspend/Resume and Shared Memory . . . . . . . . . . . . . . . . . . . . 30411.3.4 Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30911.3.5 Recover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31011.3.6 Migrate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310Part 3. Install . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 311Chapter 12. I/O virtualization implementation . . . . . . . . . . . . . . . . . . . . . 31312.1 Creating a Virtual I/O Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31412.1.1 Creating the Virtual I/O Server partition . . . . . . . . . . . . . . . . . . . . 31512.2 Installation of Virtual I/O Server. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33512.2.1 Changes on VIOS 2.2.1.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33712.2.2 Installing Virtual I/O Server using Optical device . . . . . . . . . . . . . 33912.2.3 Installing the Virtual I/O Server image using installios on HMC . . 34412.2.4 Updating the Virtual I/O Server using fix packs. . . . . . . . . . . . . . . 34612.3 Defining virtual disks for client partitions . . . . . . . . . . . . . . . . . . . . . . . . 34712.3.1 Defining virtual SCSI disks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34712.3.2 Using file-backed devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34912.3.3 Using logical volumes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350Chapter 13. Server virtualization implementation . . . . . . . . . . . . . . . . . . 35513.1 Creating a client partition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35613.1.1 Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35613.1.2 Dedicated donating processors. . . . . . . . . . . . . . . . . . . . . . . . . . . 36813.2 AIX client partition installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37013.3 Installation of IBM i client partition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37713.3.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37713.3.2 Considerations for IBM i client partitions managed by IVM. . . . . . 37813.3.3 Installation considerations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37813.3.4 Installation process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37813.4 Linux client partition installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38013.4.1 Unattended installations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38013.4.2 Multipath devices and Linux installations . . . . . . . . . . . . . . . . . . . 38113.4.3 Starting a Linux installation from the network . . . . . . . . . . . . . . . . 381Contentsvii

13.4.4 Starting a Linux installation from Virtual Media Library . . . . . . . . . 38413.4.5 Installing IBM service and productivity tools . . . . . . . . . . . . . . . . . 385Part 4. Set up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 387Chapter 14. Processor virtualization setup . . . . . . . . . . . . . . . . . . . . . . . 38914.1 Configuring Multiple Shared-Processor Pools. . . . . . . . . . . . . . . . . . . . 39014.1.1 Dynamic adjustment of Maximum Pool Capacity . . . . . . . . . . . . . 39014.1.2 Dynamic adjustment of Reserve Pool Capacity . . . . . . . . . . . . . . 39014.1.3 Dynamic movement between Shared-Processor Pools . . . . . . . . 39114.1.4 Deleting a Shared-Processor Pool . . . . . . . . . . . . . . . . . . . . . . . . 39114.1.5 Configuration scenario . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39114.2 Shared dedicated capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 399Chapter 15. Memory virtualization setup . . . . . . . . . . . . . . . . . . . . . . . . . 40315.1 Active Memory Sharing setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40415.1.1 Creating the paging devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40415.1.2 Creating the shared memory pool. . . . . . . . . . . . . . . . . . . . . . . . . 40615.1.3 Creating a shared memory partition . . . . . . . . . . . . . . . . . . . . . . . 41315.2 Active Memory Deduplication setup . . . . . . . . . . . . . . . . . . . . . . . . . . . 41615.2.1 Enabling AMD using the HMC GUI . . . . . . . . . . . . . . . . . . . . . . . . 41615.2.2 Disabling AMD using the HMC GUI . . . . . . . . . . . . . . . . . . . . . . . 41815.2.3 Enabling or disabling AMD using the HMC CLI . . . . . . . . . . . . . . 419Chapter 16. I/O virtualization setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42116.1 Virtual I/O Server setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42216.1.1 Command line interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42216.1.2 Mirroring the Virtual I/O Server rootvg . . . . . . . . . . . . . . . . . . . . . 42616.1.3 Virtual I/O Server security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42916.2 Storage virtualization setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46916.2.1 Virtual SCSI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46916.2.2 Virtual Fibre Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47716.2.3 Virtual optical. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49316.2.4 Virtual tape . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49516.2.5 Availability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49616.2.6 Availability configurations using multipathing . . . . . . . . . . . . . . . . 50416.2.7 Availability configurations using mirroring . . . . . . . . . . . . . . . . . . . 53716.2.8 Shared storage pools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57316.3 Network virtualization setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58316.3.1 Multiple VLANs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58316.3.2 SEA failover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59416.3.3 EtherChannel Backup in the AIX client . . . . . . . . . . . . . . . . . . . . . 60616.3.4 IBM i virtual IP address failover for virtual Ethernet adapters . . . . 61116.3.5 Linux Ethernet connection bonding . . . . . . . . . . . . . . . . . . . . . . . . 614viiiIBM PowerVM Virtualization Introduction and Configuration

16.3.6 General rules for setting modes for QoS. . . . . . . . . . . . . . . . . . . . 61816.3.7 Denial of Service hardening . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 618Chapter 17. Server virtualization setup. . . . . . . . . . . . . . . . . . . . . . . . . . . 62117.1 Live Partition Mobility setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62217.1.1 Live Partition Mobility enablement . . . . . . . . . . . . . . . . . . . . . . . . 62217.1.2 Live Partition Mobility setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62517.1.3 Configuring the external storage . . . . . . . . . . . . . . . . . . . . . . . . . . 64817.2 Suspend and Resume setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65217.2.1 Creating a reserved storage device pool . . . . . . . . . . . . . . . . . . . 65217.2.2 Creating a suspend and resume capable partition . . . . . . . . . . . . 65917.2.3 Validating that a partition is suspend capable . . . . . . . . . . . . . . . . 66217.2.4 Suspending a partition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66417.2.5 Validating that a partition is resume capable . . . . . . . . . . . . . . . . 66917.2.6 Resuming a partition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 671Part 5. Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 675Appendix A. Recent PowerVM enhancements . . . . . . . . . . . . . . . . . . . . . 677A.1 New features in PowerVM2.2 and Virtual I/O Server Version 2.2 FP26 . 678A.2 New features in PowerVM2.2 and Virtual I/O Server Version 2.2 FP25 . 679A.3 New features in Version 2.2 FP24-SP1 of Virtual I/O Server . . . . . . . . . 681A.4 New features in Version 2.1 of Virtual I/O Server . . . . . . . . . . . . . . . . . . 682Appendix B. POWER processor modes . . . . . . . . . . . . . . . . . . . . . . . . . . 685Appendix C. Capacity on Demand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 687Appendix D. Simultaneous Multithreading . . . . . . . . . . . . . . . . . . . . . . . . 689D.1 POWER processor SMT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 690D.2 SMT and the operating system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 691D.2.1 SMT control in AIX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 692D.2.2 SMT control in IBM i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 695D.2.3 SMT control in Linux. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 696Appendix E. Active Memory Expansion . . . . . . . . . . . . . . . . . . . . . . . . . . 699E.1 Prerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700E.2 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700E.3 Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 702E.4 Active Memory Expansion setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 703Appendix F. IBM i Virtual Partition Manager . . . . . . . . . . . . . . . . . . . . . . . 707F.1 Planning considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 708F.2 Creating an IBM i client partition using VPM . . . . . . . . . . . . . . . . . . . . . . 709F.3 Creating a Linux partition using VPM . . . . . . . . . . . . . . . . . . . . . . . . . . . 709Contentsix

Appendix G. AIX Workload Partitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 711G.1 Characteristics of WPARs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 713G.2 Types of WPARs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 713G.2.1 System WPARs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 714G.2.2 Application WPARs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 714G.3 Live Application Mobility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 715Appendix H. System Planning Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 717H.1 Sample scenario . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 718H.2 Preparation recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 719H.3 Planning the configuration with SPT. . . . . . . . . . . . . . . . . . . . . . . . . . . . 720H.4 Initial setup checklist. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 728Abbreviations and acronyms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 731Related publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 735IBM Redbooks publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 735Online resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 736Help from IBM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 740Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 741xIBM PowerVM Virtualization Introduction and Configuration

Figures1-1 Example of virtualizati

IBM PowerVM Virtualization Introduction and Configuration June 2013 International Technical Support Organization SG24-7940-05

Related Documents:

Novell SUSE Linux Enterprise Server 10 for POWER (5639-S10) Red Hat Enterprise Linux 5 for POWER (5639-RHL) IBM PowerVM Express Edition (5765-PVX) IBM PowerVM Standard Edition (5765-PVS) IBM PowerVM Enterprise Edition (5765-PVE) IBM Virtual I/O Server Version 2.1 with Fix Pack 20.1, or late

Connecting Violin Memory Arrays to IBM AIX and PowerVM 3 www.vmem.com 1 Introduction This technical report describes best practice recommendations and host attachment procedures for connecting Violin arrays through Fibre Channel to systems running on the IBM AIX operating system with IBM PowerVM virtualization.

PowerVM Express Edition: Supports 2 VMs/server and includes Virtual I/O Server (VIOS) and PowerVM Lx86 PowerVM Standard Edition: Scales to 10 VMs/core and adds suspend/resume and shared storage pools PowerVM Enterprise Edition: Adds active memory sharing and live partition mobility Integrat

Host Attachment: Connecting Violin to AIX and PowerVM www.vmem.com 1 Introduction This technical report describes best practice recommendations and host attachment procedures for connecting Violin arrays through Fibre Channel to systems running on the IBM AIX operating system with IBM PowerVM virtualization.

Modi ed IBM IBM Informix Client SDK 4.10 03/2019 Modi ed IBM KVM for IBM z Systems 1.1 03/2019 Modi ed IBM IBM Tivoli Application Dependency Discovery Manager 7.3 03/2019 New added IBM IBM Workspace Analyzer for Banking 6.0 03/2019 New added IBM IBM StoredIQ Suite 7.6 03/2019 New added IBM IBM Rational Performance Test Server 9.5 03/2019 New .

IBM PowerVM Enterprise Edition Power System Medium 9080 MHE 780E058 64.000 Software Maintenance for IBM PowerVM Enterprise Edition SWMA for PowerVM Enterprise Edition XY2XT 9080 MHE 780E058 64.000 MACHINE CONTROL PROGRAM MCP Remot

Chapter 1. Introduction to IBM Power Virtualization Center IBM Power Virtualization Center is designed to simplify the management of virtual resources in your Power Systems environment. This topic provides an overview of what you can do using IBM PowerVC. Using IBM Power Virtualization Center, you can do the following:

appropriate strategies to solve problems. Mathworld.com Classification: Number Theory Diophantine Equations Coin Problem 02-02. 14 AMC 8 Practice Questions Continued -Ms. Hamilton’s eighth-grade class wants to participate intheannualthree-person-teambasketballtournament. The losing team of each game is eliminated from the tournament. Ifsixteenteamscompete, howmanygames will be played to .