Container RefrigerationDataLINEUser Manual62-10629 Rev B

DataLINEUser Manual Carrier Corporation, 2017 Printed in U. S. A. September 2017

TABLE OF CONTENTSPARAGRAPH NUMBERPageOVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.1DATALINE OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–11–1HARDWARE AND SOFTWARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.1PC REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2–12–2.2–22.1.2Microsoft Office Pre-Requisite Requirement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.2INSTALLATION & START UP PROCEDURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.1.12–22–22.3.NET Framework Pre-Requisite Requirement2.2.1Windows 7/8/10 Full Installation.2.2.2Service Pack Installation2.2.3Uninstall Earlier Versions of DataLINE.2.2.4Repair the Installation2–22–6.2–10.2–112.2.5Start-Up Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .USER ACCESS RIGHTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2–122–12LAUNCH PAD SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.1INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.2LAUNCH PAD SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3–13–13–1PROGRAM OPTIONS SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.1INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.2PROGRAM OPTIONS SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4–14–14–1INTERROGATOR SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.1INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.2INTERROGATOR SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.3ENTER FILE COMMENT SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5–15–15–15–25.3.1Interrogation Results Summary Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5–3VIEWDATA SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6.1INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6.2VIEWDATA SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6.3GENERATE REPORTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6–16–16–16–26.3.1Create Custom Report Template . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6–56.3.2Generate Custom Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6.4PAGE SETUP SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6.5PRINT PREVIEW SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6–86–86–9DATAREADER FILE UTILITY SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7.1INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7.2DATAREADER FILE UTILITY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7.3FILE DOWNLOAD RESULTS SUMMARY SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7–17–17–17–2CONTAINER CONFIGURATION UTILITY SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8.1INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8.2CONTAINER CONFIGURATION UTILITY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8.3DATASET EDITOR SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8–18–18–18–3SYSTEM TOOLS SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9.1INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9.2SYSTEM TOOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9–19–19–19.2.1Features Available on the System Tools Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .i9–262-10629

9.3DATACORDER CONFIGURATION SCREEN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–29.3.1Features Available on the DataCorder Configuration Screen . . . . . . . . . . . . . . . . . . . . . . . . 9–49.4CONTROLLER CONFIGURATION SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–59.4.1Features Available on the Controller Configuration Screen . . . . . . . . . . . . . . . . . . . . . . . . . 9–69.5CONTROLLER PARAMETERS SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–69.6ISO TRIP HEADER SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–7PROBE AND SENSOR CALIBRATION SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–110.1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–110.2 UNITS WITH ML3 CONTROLLERS LOADED WITH SWR53XX SERIES . . . . . . . . . . . . . . . . . 10–110.2.1USDA Probe Calibration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–210.2.2 Supply Air and Return Air Temperature Sensor Calibration (SWR 5368 and higher only) . 10–410.3 ALL OTHER ML3 CONTROLLERS LOADED WITH SWR51XX SERIES SWR53XX BELOW 5368,SWR57XX SERIES AND ALL ML2I CONTROLLERS10–10DATA MANAGER SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11–111.1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11–111.2 DATA MANAGER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11–111.2.1 Features Available on the Data Manager Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11.3 VIEW FILE DETAILS SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11.4 SPECIFY SEARCH CRITERIA SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11.5 SPECIFY SORTING CRITERIA SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11–111–211–311–3MONITOR SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12.1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12.2 MONITOR SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12.3 LOG MONITOR DATA SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12.4 OVERRIDE VARIABLE VALUE SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EX–1

LIST OF ILLUSTRATIONSFIGURE NUMBERPageTable 2–1 DataLINE Software.2–1.2–2.6–3Figure 1.1 Launch Pad Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–1Figure 3.1 Launch Pad Screen with Application Launch Pad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3–1Figure 4.1 Program Options Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4–1Figure 5.1 Interrogator Screen.5–1.5–2Table 2–2 PC RequirementsTable 6–1 Report EventsFigure 5.2 File Comment ScreenFigure 5.3 Interrogation Results Summary Screen.5–3Figure 6.1 ViewData Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6–2Figure 6.2 CreateReport Screen.6–4Figure 6.3 Report Date Range Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6–4Figure 6.4 Custom Graph Report Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6–6Figure 6.5 Custom Sensor Report Screen.6–6Figure 6.6 Custom Alarm Summary Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6–7Figure 6.7 Custom Event Report Screen6–7.Figure 6.8 Generate Custom Report Screen.6–8.6–8.6–9Figure 6.9 Page Setup ScreenFigure 6.10 Print PreviewFigure 7.1 DataReader File Utility Screen.7–1Figure 7.2 DataReader Connected Screen.7–2Figure 7.3 File Download Completed Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7–3Figure 8.1 Container Configuration Utility Screen.8–1.8–2Figure 8.2 DataReader ConnectionFigure 8.3 Commit Process Completed.8–3Figure 8.4 DataSet Editor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8–3Figure 8.5 DataCorder Configuration Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8–4Figure 9.1 System Tools Screen.9–1Figure 9.2 DataCorder Configuration Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9–3Figure 9.3 DataCorder Custom Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9–4Figure 9.4 Controller Configuration Screen.9–5.9–6.9–7Figure 9.5 Controller ParametersFigure 9.6 ISO Trip HeaderFigure 10.1 Probe Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10–1Figure 10.2 Auto Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10–2Figure 10.3 USDA/Cargo Probe Calibration (Auto) During Calibration.10–3.10–4.10–5Figure 10.4 Probe Calibration ScreenFigure 10.5 Supply Air Sensor RemovalFigure 10.6 Sensor Selection from Probe Calibration Screen.10–6.10–6.10–7Figure 10.7 Location of ServiceFigure 10.8 Start CalFigure 10.9 Calibrate Complete.iii10–762-10629

Figure 10.10 Calibration ResultsFigure 10.11 Event File. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–8Figure 10.12 Return Air Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–9Figure 10.13 Sensor Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–9Figure 10.14 Ice Bath PlacementFigure 10.15 Auto Calibration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–11Figure 10.16 USDA/Cargo Probe Calibration (External)Figure 11.1 Data Manager Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11–1Figure 11.2 File Import Results Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11–1Figure 11.3 File Delete Results Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11–2Figure 11.4 View File Details Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11–2Figure 11.5 Specify Search Criteria Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11–3Figure 11.6 Specify Sorting Criteria Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11–3Figure 12.1 Monitor Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12–1Figure 12.2 Enter Log File Name. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12–2Figure 12.3 Start Logging. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12–3Figure 12.4 Edit Variables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12–4LIST OF TABLESTABLE NUMBERPageTable 2–1 DataLINE Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–1Table 2–2 PC Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–2Table 6–1 Report Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–362-10629iv

SECTION 1OVERVIEW1.1DATALINE OVERVIEWThe information contained in this manual provides details about the Carrier Transicold DataLINE application and itsinterface with the DataCorder. DataLINE diagnostic software interrogates, configures and monitors the refrigerationunit controller and DataCorder trip data recorder.The DataLINE utilities are accessible from a Launch Pad Screen (Figure 1.1), which is explained in detail in theLaunch Pad Screen chapter of this manual. The DataLINE utilities are listed below: Interrogator utility System Tools utility Probe Calibration utility Monitor utility DataReader File utility Container Configuration utility View Data utility Data Manager utility Program Options utility Help utilityFigure 1.1 Launch Pad Screen1–162-10629

SECTION 2HARDWARE AND SOFTWARENOTICEThe user should access the DataLINE Help utility that is included with the DataLINE applicationto obtain a more in-depth understanding of the DataLINE application and its features. The Helputility provides the user with detailed directions for using the DataLINE applicationThe DataLINE application provides capabilities for the following hardware platforms:1. MicroLink 2i (ML2i) based integrated Controller/DataCorder units2. MicroLink 3 (ML3) based integrated Controller/DataCorder unitsNOTEData from a Microlink (ML1) unit must be retrieved using the Carrier *DataReader hand held device.DataLINE can then be used to transfer data from the *DataReader to a PC.NOTEConnections to MicroLink 3 (ML3) Controller/DataCorders and reports generated from MicroLink 3downloads will be identified as MicroLink 2i by the DataLINE application.Data retrieval can be accomplished with one of the following devices:1. Stand-alone, windows-based portable personal computer (PC) with the appropriate cable and DataLINEapplication.2. Carrier DataBANK card. Data can be transferred to a personal computer using the Omnidrive interface forreading by DataLINE.3. Carrier *DataReader hand held retriever. The data can be transferred from the DataReader to a PC.All data retrieved from a DataCorder is automatically converted to a DCX file, which is a Carrier Transicold proprietary file format.As new versions of the DataLINE software are released, updates to the software will be available on the CarrierTransicold web site. These updates are called a “Service Pack”. In order to protect software ownership, a ServicePack can only be loaded onto a PC that already has DataLINE software installed.Table 2–1 DataLINE SoftwarePART NUMBERDESCRIPTIONAPPLICATION07-00421-00CD DataLINE SoftwarePC/Windows* The legacy DataReader device is still supported through DataLINE but no longer available for purchase.2–162-10629

2.1PC REQUIREMENTSTable 2–2 PC RequirementsProcessorMinimum PC System ConfigurationRecommended PC System ConfigurationPentiumPentium V or equivalentOperating SystemWindows 7 - All (32 bit and 64 bit)(support both 32 bitWindows 8and 64 bit)Windows 10Windows 7 - Enterprise (32 bit), WindowsEnterprise (64 bit).Windows 8Windows 10RAM2GB4GBHard Disk120 MB free disk space120 MB free disk spaceDisk Drive DCD-ROM (installation support)CD-ROM (installation support)VideoVGAVGA Video Resolution800 x 600800 x 600 Serial Port1 RS-232 port (COM 1)1 RS-232 port (COM 1) or any other COMport if user has added additional serial ports.USB Port1 USBMore than 1 USBPrinter Port1 standard printer port (LPT 1) or 1 USB port 1 standard printer port (LPT 1) or 1 USB portModemNot requiredOption (Internet installation support)PCMCIA CardPCMCIA Type I slotPCMCIA Type I slot or adapter.NetworkConnectionNot requiredYes (remote printer support & networkinstallation)Pre-Requisites.Net Framework 4.5.Net Framework 4.5 with administratorprivileges2.1.1.NET Framework Pre-Requisite RequirementTo install DataLINE, the target PC must have .NET Framework 4.5 installed.2.1.2Microsoft Office Pre-Requisite RequirementTo work with DataLINE Text reports in .XLS format, the target PC must have Microsoft office 2010 or greater.2.2INSTALLATION & START UP PROCEDURES2.2.1Windows 7/8/10 Full InstallationThe DataLINE application is delivered to users on a CDROM.Procedure for All Users:1. Place the CD in the CD drive. The installation may automatically start and will display the Welcome screen.2. The primary method for loading the program is to access the appropriate drive and double click on the“DataLINE Setup.exe” file. The application installation screen is automatically launched.An alternative method for loading the program is to click on the Windows “Start” button and then click on“Run” to display the Run screen.62-106292–2

Enter the path name for the appropriate drive as instructed, e.g. D:\ DataLINE Setup.exe, with D representing the drive. Then, click “OK” to launch the Application Installation screen.NOTEIf the user does not have administrator rights on the machine that DataLINE is being installed, installation can not proceed further.3. The Welcome screen is displayed to begin the setup process. Click “Next” to bring up the License screen.If “Cancel” is clicked, a screen appears asking to cancel the DataLINE installation. Click “Yes” to exit theinstallation. Click “No” to resume the setup process and return to the initial Welcome screen.2–362-10629

4. On the License Agreement screen, the default option selected is “I do not accept the terms in Licenseagreement”. Change the selection to “I accept the terms in the license agreement”.5. Click “Next” to display the Destination Folder screen.6. At the Destination Folder screen, specify into which directory the system should store the application. Thedefault directory is C:\Program Files (x86)\Carrier\DataLINE\. Click the “Change” button to choose analternate directory.7. Click “Next” to display the Destination Folder screen to select the folder for data files.62-106292–4

8. At the Destination Folder screen, specify the directory for storing Downloaded data from the system. Thedefault directory is C:\Carrier\AppData\DataLINE. Click the “Change” button to choose an alternate directory.9. Click “Next” to display the Ready To Install screen.10. Click “Install” to start the application installation. Or, click “Cancel” to exit the installation.2–562-10629

11. Once the Installation has completed, a screen appears stating that DataLINE was installed successfully.12. Click “Finish” to finish the installation of the application.2.2.2Service Pack InstallationIn order to install the service pack, the target computer must already have DataLINE 2.1 or 2.2 installed.If DataLINE 2.0 or older is installed, follow the additional instructions for DataLINE 2.2 and then upgrade toDataLINE 2.2 prior to upgrading to DataLINE 3.1.Procedure for All Users:1. Download the service pack from the container public website under Product/DataLINE or place the CD inthe CD drive.2. The method for loading the program is to access the appropriate drive and double click on the“DataLINE Setup.exe” file.If the user does not have administrator rights on the machine to install DataLINE, installation cannot proceed further.If no existing installation of DataLINE was detected, a screen will be displayed to confirm this. Click “OK”and the installation will abort.62-106292–6

3. If DataLINE version 2.1 or 2.2 is installed, a Welcome screen is displayed to begin application setup.4. Click “Next” to proceed to the License screen.NOTEIf the user clicks “Cancel” on the Welcome screen, a screen appears asking to cancel the DataLINEinstallation. Click “Yes” to cancel the installation or click “No” to resume setup and return to the initialWelcome screen.2–762-10629

5. At the License Agreement screen, the default option selected is “I do not accept the terms in license agreement”. Change the selection to “I accept the terms in the license agreement”.6. Click “Next” to display the Destination Folder screen.7. At the Destination Folder screen, specify the directory to store the application. The default directory isC:\Program Files (x86)\Carrier\DataLINE\. Click the “Change” button to choose an alternate directory.!WARNINGIt is recommended that DataLINE 3.1 is installed into its own directory and not into the samedirectory as a previous version.8. Click “Next” to display the Destination Folder screen to select the folder for data files.62-106292–8

9. At the Destination Folder screen, specify into which directory the system should store Downloaded data. Thedefault directory is C:\Carrier\AppData\DataLINE. Click the “Change” button to choose an alternate directory.10. Click “Next” to display the Ready to Install screen.11. Click “Install” to start the application installation.2–962-10629

12. When installation has completed, a screen appears stating that DataLINE was installed successfully.13. Click “Finish” to the complete the service pack installation.14. After installation is complete, follow the procedure in Section 2.2.3 to uninstall earlier versions of DataLINE.2.2.3Uninstall Earlier Versions of DataLINEUsers must utilize the “Uninstall” utility found in Windows when uninstalling the DataLINE application. Deleting filesvia Windows Explorer should not be attempted as this can result in system instability.Procedure for Windows 7 and Windows 8:1. Click on the “Start” button.2. Click on “Control Panel”.3. Under the Programs category, click on “Uninstall a program”.4. Look for earlier versions of DataLINE program and click on it to select.5. Click on the “Uninstall” button.6. The DataLINE uninstall screen will start, which completes the uninstall procedure.Procedure for Windows 10:1. Click on the “Start” button.2. Click on “Settings”.3. Click on “Systems”.4. Click on “Apps & features”.5. Look for earlier versions of DataLINE program and click on it to select.6. Click on the “Uninstall” button.7. The DataLINE uninstall screen will start, which completes the uninstall procedure.!WARNINGUninstalling earlier versions of DataLINE (2.1 or 2.2) will result in loss of Custom Controller andDataCorder configurations, hence the user needs to recreate those custom configurations inthe latest version of DataLINE 3.1.62-106292–10

!WARNINGUninstalling earlier versions of DataLINE (2.1 or 2.2) will result in loss of online communication, requiring the installation to be repaired. Follow instructions in Section 2.2.4 for procedure.2.2.4Repair the Installation1. Double click on the “DataLINE Setup.exe” file to open a Welcome screen.2. Click “Next” to bring up the Program Maintenance screen.3. On the Program Maintenance screen, the default option selected is “Modify”. Change the selection to“Repair”.2–1162-10629

4. Click “Next” to bring up the Ready to Repair screen.5. Click “Install” to repair the installation. The InstallShield Wizard Completed screen appears.6. Click “Finish” to complete the Installation.2.2.5Start-Up Procedure1. Click on the “Windows” button.2. Navigate to “All Programs”.3. Click on the “Carrier” folder.4. Click on “Launch Pad”.2.3USER ACCESS RIGHTSFor All Users on Windows 7/8/10In order to access the complete functionality of DataLINE, users should have administrator access rights on themachine that DataLINE is installed.62-106292–12

SECTION 3LAUNCH PAD SCREEN3.1INTRODUCTIONThis section describes the features available on the Launch Pad screen. The screen contains the ApplicationLaunch Pad, which is the entry point into the DataLINE program. The Application Launch Pad provides a centrallaunching mechanism in order to launch the utilities built into the DataLINE program.3.2LAUNCH PAD SCREENThe Launch Pad screen (Figure 3.1) is displayed when the DataLINE application is started.Figure 3.1 Launch Pad Screen with Application Launch PadThe Application Launch Pad utilities are described below and can be launched by clicking on the designated buttonfor the utility. The Interrogator utility provides the capability to interrogate and download data from the DataCorder portion of the container refrigeration unit. Refer to the Interrogator Screen chapter for detail. The System Tools utility provides the capability to modify Controller information, update the DataCorderclock and start a new trip. It also allows the user to view/modify the DataCorder and Controller configuration,modify Controller parameters and modify the ISO trip header. Refer to the System Tools Screen chapter fordetail. The Probe Calibration utility provides the capability to calibrate USDA and Cargo probes for Cold treatment cargos, as well as Supply and Return probes where cargo requires it. Refer to the Probe and SensorCalibration Screen chapter for detail. The Monitor utility provides an interface to monitor the status of the refrigeration unit's analog inputs/outputs and discrete inputs/outputs for diagnostic purposes. Refer to the Monitor Screen chapter for detail. The DataReader File utility provides the capability to download raw files from the DataReader*, which arethen converted to DCX format by DataLINE. Refer to the DataReader File Utility Screen chapter for detail.3–162-10629

The Container Configuration utility provides the capability to create/modify/copy/delete container configurations from the PC and the DataReader*. Refer to the Container Configuration Utilit

3. Carrier *DataReader hand held retriever. The data can be transferred from the DataReader to a PC. All data retrieved from a DataCorder is automatically converted to a DCX file, which is a Carrier Transicold propri-etary file format. As new versions of the DataLINE software are released, updates to the s

Related Documents:

Carrier Aggregation LTE-Advanced maximum bandwidth Carrier 1 Carrier 2 Carrier 3 Carrier 4 Carrier 5 Rel'8 BW Rel'8 BW Rel'8 BW Rel'8 BW Rel'8 BW Release Max No of Carriers Peak DL Rate 2x2 MIMO 8x8 MIMO LTE-A 5 (up to 100 MHz) 1 Gbps 3.9 Gbps LTE-A Pro 32 (up to 640 MHz) 6.3 Gbps 25.1 Gbps

carrier reefer parts part number wrench crowfoot 07-00411-00 bit, torx driver 07-00418-00 dataline software 07-00421-00 pk12- oil mobil 32st 07-00427-00 tester- ml2i/ml3 07-00428-00sv analyzer ml2i - ml3 rep 07-00428-00svrb omni pc card drive- parl. port 07-00438-00 omni pc card drive usb port 07-00439-00 charger- card 220v for omni dr 07-00446-01

Morphy Richards Fastbake Breadmaker 48280 User Manual Honda GCV160 User Manual Canon Powershot A95 User Manual HP Pocket PC IPAQ 3650 User Manual Navman FISH 4200 User Manual - Instruction Guide Jensen VM9021TS Multimedia Receiver User Manual Sanyo SCP-3100 User Manual Honda GC160 User Manual Canon AE-1 Camera User Manual Spektrum DX7 User Manual

Carrier reserves the right to refuse to transport any shipment for any reason it deems reasonable, before consignment. After consignment, however, Carrier agrees to assume all liabilities for delivery of ca rgo intact. Broker agrees to pay Carrier as carrier's agent for services rendered with Carrier's invoice & legible, clean

Ademco Passpoint Plus User Manual Morphy Richards Fastbake Breadmaker 48280 User Manual Honda GCV160 User Manual Canon Powershot A95 User Manual HP Pocket PC IPAQ 3650 User Manual Navman FISH 4200 User Manual - Instruction Guide Jensen VM9021TS Multimedia Receiver User Manual Sanyo SCP-3100 User Manual Honda GC160 User Manual Canon AE-1 Camera .

E-816 DLL Manual, PZ120E E-621.CR User Manual, PZ160E E-816 LabVIEW Software Manual, PZ121E E-621.SR, .LR User Manual, PZ115E Analog GCS LabVIEW Software Manual, PZ181E E-625.CR User Manual, PZ166E PIMikromove User Manual, SM148E E-625.SR, .LR User Manual, PZ167E E-665 User Manual, PZ127E E-801 User Manual

Example: A nursing home may transport their ownclients as a private carrier. Example: An excavation company may transport their ownequipment to a job site as a private carrier. A private carrier does not need to apply for a Federal Motor Carrier Number (MC Number), but does need to regi

This manual is the basic textbook for anyone writing an ASTM standard. A study of Parts A, B, C, or E will show the proper form for the principal types of standards including a detailed explanation of how to write each section, from the title to the appendixes. Within Parts A, B, C, and E, the first section lists the preferred sequence of headings and indicates whether these sections are .