Packaged Terminal Air Conditioner (PTAC)FFRP152HT3Air Conditioner /Heat Pump /Backup Electric HeaterProduct DimensionsHeight16"Width42"Depth21-3/4"More Easy-To-Use FeaturesComfort Control DesignSimple controls allow guests tocustomize their settings, while quiet,uniform air movement keeps roomscomfortable.Smart Self-CheckProvides nine diagnostic points for selfcheck and correction of fault conditions.Eco-FriendlyFrigidaire uses R-410A refrigerant that’snot harmful to the earth’s ozone layerand meets U.S. Environmental ProtectionAgency requirements.Effortless OperationSimple, intuitive room controls are easyfor guests to operate — ensuring arelaxing, more comfortable stay. Featureslike Effortless Restart and Ready-Select controls reduce maintenance calls.PerformanceBTUsCool14,500 /14,200Backup Electric Heater11,700 / 9,600Heat Pump13,300 / 13,000Signature FeaturesCorrosion GuardDry ModeA corrosion-resistant fin coating extendsoperation life and your investment,plus it is easier to maintain in coastalenvironments.Dry Mode feature will help manage andreduce the humidity content within theliving space, making it more comfortable.Effortless MaintenanceSilentDesign With Frigidaire’s reputation for durability,easy maintenance, availability of reliableparts and service you can count on,you can be sure that you’re getting thehighest-quality performance.Sound reduction package.frigidaire.com

Packaged Terminal Air Conditioner (PTAC)FFRP152HT3PerformanceBTU (Cool)14,500 /14,200BTU (Backup Electric Heater)11,700 / 9,600BTU (Heat Pump)13,300 / 13,000Dehumidification (Pints / Hour)3.5Cool Area (Sq. Ft.)830Energy Efficiency Ratio10.4Air Conditioner / Heat Pump / Backup Electric HeaterPTAC NomenclatureFFRP07Amps (Cool)Amps (Backup Electric Heater)Amps (Heat Pump)Watts (Cool)RAC P-TAC ModelsFrigidaire N YEART 2017230 / 2086.2 / 6.715.0 / 13.66.2 / 6.71,390 / 1,365Watts (Backup Electric Heater)3,450 / 2,820Watts (Heat Pump)1,255 / 1,225Cable IncludedYesLength of Power Cord5.5'Circuit Breaker20APlug Type (NEMA)LCDI (6-20P)BTU OUTPUT07 7,200 / 7,00009 9,400 / 9,20012 11,800 / 11,60015 14,500 / 14,200HEATL ElectricH Heat Pump230/208V2 15A3 20A4 30A265V5 15A6 20A7 30AFeaturesFin CoatingCorrosion GuardDry ModeYesElectronic ControlsReady-Select ControlsFront Desk Control ReadyYesFan Speeds (Dry / Cool / Fan / Heat)1/2/2/2Noise Level Indoors (High / Low)54 / 51Quiet Start-UpYesLow Voltage Start-UpYesRandom Restart ProtectionYesEffortless Auto Freeze ProtectionYesEnergy SaveYes24-Hour On / Off TimerYesAir CFM (High / Low)341 / 306Air Direction ControlAuxiliary 2-WayAir IntakeFresh or RecycledFilter TypeNylon MeshFilter AccessSlide-OutSlide-Out ChassisYesCommercial Grade Warranty1YesDACertificationsSafety CertificationUL, CUL & CSAPerformanceAHRI & CECCBSpecificationsRefrigerantR410aCharge38.8 oz.Shipping Weight (Approx.)144 Lbs. Warranty 5 year sealed system / 2 year full parts and labor.1NOTE: For planning purposes only. Always consultlocal and national electric codes. Refer to ProductInstallation Guide for detailed installation instructionson the web at frigidaire.com.Plug Type (NEMA)6-20PProduct Dimensions2Wall Cutout DimensionsA - Height16"Height16-1/4"B - Width42"Width42-1/4"C - Depth (Overall Unit)21-3/4"D - Depth (Inside Sleeve)13-3/4"Max. Wall Thickness13-1/2"2 Unless the PTAC unit is installed with a wall sleeve.Accessories information availableon the web at frigidaire.comUSA 10200 David Taylor Drive Charlotte, NC 28262 1-800-FRIGIDAIRE frigidaire.comCANADA 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-800-265-8352 frigidaire.caFFRP152HT3 01/17 2017 Electrolux Home Products, Inc.Specificationssubject to change.

Packaged Terminal Air Conditioner (PTAC)Air Conditioner / Heat Pump / Backup Electric HeaterFFRP152HT3RearwardRearward SlopeSlopeWall SleeveWall SleeveAdapterAdapter1/4" Slope1/4" SlopeAccessoryAccessoryOutdoor GrilleOutdoor GrilleAccessory OutdoorGrilleFront PanelFront PanelAccessory Wall SleeveAccessoryAccessoryWall SleeveWall SleeveOutsideOutside WallWall InsideInside WallWallChassisFront PanelChassisChassisPlug Type (NEMA)6-20PProduct DimensionsWall Cutout 4"Depth (Overall Unit)21-3/4"Depth (Inside Sleeve)13-3/4"Max. Wall Thickness13-1/2"PTAC SpecificationsReplacement Installation Product Shipping Weight (approx.) – 144 Lbs. An electrical supply with grounded three-prong receptacle is required. When replacing existing PTAC with new unit, refer to ProductThe power supply circuit must be installed in accordance with currentedition of National Electrical Code (ANSI/NFPA 70)and local codes & ordinances. Voltage Rating – 230V / 208V / 60 Hz Amps @ 230/208V Volts (Cool) 6.2 / 6.7 Amps /(Backup Electric Heater) 15.0 / 13.6 Amps / (Heat Pump) 6.2 / 6.7 Amps Always consult local and national electric codes. Recommended Circuit Breaker – 20 Amps Unit equipped with 230/208V 3-wire power supply cord, NEMA plugtype 6-20P, approximately 66" long. In order for condensate water to drain properly inside the unit, thesleeve must be installed properly: Level from right to left with a slight1/4" rearward pitch from the indoor side to the outdoor side as shown inthe illustration above. Refer to the Installation Instructions on the web. The drain kit listed on the Frigidaire PTAC Accessories page canbe used for an internal or external drain. This applies to new andreplacement installation.Installation Guide on web to identify existing wall-sleeve manufacturerand size compatibility. If proper installation and slope are suspect,then correct installation of Frigidaire PTAC Sleeve optionsrecommended. For any sleeve retrofit application, be sure that the foam seals(factory-installed on the tube sheets) provide a good seal betweenthe grille and the outdoor coil tube sheets. These foam seals providea barrier that stops air from the inside mixing with air on the outside(known as air recirculation). Using Frigidaire wall sleeve with Non-Frigidaire grille requiresinstallation of an Accessory Baffle Kit, which ensures a good sealbetween the unit and exterior grille to prevent air recirculation. Airrecirculation is a large contributor to performance loss and prematuredamage to major components.Note: For planning purposes only. Refer to Product Installation Guideon the web at frigidaire.com for detailed instructions.*See Frigidaire PTAC accessories pages attached for optional accessories.New Installation For new installation, Frigidaire PTAC Sleeves are available andrecommended for proper installation. See accessories pages forsleeve options.* Standard PTAC installation requires 13-1/2" maximum wall thickness,unless a wall sleeve is used. If the PTAC unit protrudes more than 4", then it is suggested that it beinstalled with a subbase. See accessories pages for subbase options.USA 10200 David Taylor Drive Charlotte, NC 28262 1-800-FRIGIDAIRE frigidaire.comCANADA 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-800-265-8352 frigidaire.caFFRP152HT3 01/17 2017 Electrolux Home Products, Inc.Specificationssubject to change.

Packaged TerminalAir Conditioner (PTAC)ACCESSORIESWall Sleeves and Drain KitMetal Wall Sleeve & Accessories5304482701 Steel Sleeve – Insulated5304483759 16" Extended Sleeve – Insulated5308815304 18" Extended Sleeve – Insulated5308815305 24" Extended Sleeve – Insulated5304483760 3" Sleeve AdapterMetalWall SleeveThese fully insulated sleeves are made of electro-galvanizedsteel that resists corrosion, and welded areas are sealed witha rust preventive. White powder coating matches PTAC units.Sliding keyhole grille attachments enable easy, one-personinstallation from the inside.PolymerWall SleevePolymer Wall Sleeve5308815302 InsulatedUtilizes fiberglass-reinforced polyester compound to producea durable, noncorrosive wall case that provides superior soundabsorption, reduces heat loss and prevents sleeve sweating.(Requires use of a Polymer Architectural Grille.)Condensation Universal Drain Kit5304480570 1-PackControls condensate from the PTAC unit and can be used forexterior or interior drain systems. Includes 1/2" O.D. copper draintubes with a short right angle tube and a 6" straight tube to suitthe application. (Recommended for all new sleeve installations.)Condensation Universal Drain KitOutdoor GrillesStampedAluminumGrilleStamped Aluminum Outdoor Grille5304480557 Clear Anodized Aluminum FinishCost-effective, one-piece stamped grille is made from durableanodized aluminum. The grille is lightweight, has a clear finishand is easy to install from inside the room.Architectural Aluminum Outdoor Grilles5304480558 Clear Anodized Aluminum Finish5308815313 Dark Brown530448055X Customized ColorEnhances the appearance of any building. Made of a durable,anodized aluminum that offers weather resistance. Slidingkeyhole attachment enables easy installation onto Frigidaire metal wall sleeve.ArchitecturalAluminumGrillePolymer Architectural Outdoor GrillesPolymerArchitecturalGrilleFR PTAC ACC 01/175308815310 Brown5308815312 Alpine BeigeBlends with most building exteriors. Its durable design offersprotection, has an enhanced appearance and provides superiorweather resistance. (Requires use of a Polymer Wall Sleeve.)

Packaged TerminalAir Conditioner (PTAC)ACCESSORIESSubbases and Leveling LegsDecorative SubbaseDecorativeSubbase5308815315 BlackMade of heavy-gauge steel to provide support for the wall sleeve,the subbase mounts directly to the wall sleeve and has adjustableleveling legs.Black Electrical Subbases5304482886 230V/15A5304482891 265V / 30A5304482888 230V / 30A5304482890 265V / 20A5304482887 230V / 20AElectricalSubbase5304482698265V Subbase Disconnect Switch5304490211Hardwire Kit, Conduit and Plate(For 230V and 265V)Offers the same features as the decorative subbase, plus afactory-installed electrical junction box containing a receptaclefor corded PTAC units.Leveling LegsLeveling Legs5304480575Attach easily to the wall sleeve and offer accurate leveling andsupport for units without a subbase. Adjustable from 3-1/4" to 5-1/2".Air FiltersAir Filters5304482892 10-PackChanging filters periodically ensures a healthy room environment,proper airflow, temperature control and energy efficiency.Air FiltersWall ThermostatsWireless Digital Wall ThermostatFFTSTATWL Non-Programmable (Includes Wireless Receiver)Wall ThermostatsAllows control without having to worry about wiring. Easy to installand use. Large intuitive LCD screen improves user interaction.Wired Digital Wall Thermostats5304482700 Programmable5304483050 Non-ProgrammableOffers auto-changeover, 2-stage heating and cooling, as well asemergency heating mode for heat pump.Laminated InsertFPTAC0511FFTSTATWL5304483050Informs guests that unit is controlled by wall thermostat.MiscellaneousLateral Duct Kit5304490206Lateral Duct KitAllows one PTAC unit to heat or cool two rooms. Kit mounts towall sleeve and can be installed for either right- or left-side ductapplications.Baffle Kit5304484585FR PTAC ACC 01/17Baffle Kit for use on non-standard grilles.

USA 10200 David Taylor Drive Charlotte, NC 28262 1-800-FRIGIDAIRE frigidaire.com CANADA 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-800-265-8352 frigidaire.ca 2Unless the PTAC unit is installed with a wall sleeve. Performance BTU (Cool) BTU (Backup Electric Heater) BTU (Heat Pump) Dehumidi cation (Pints / Hour) Cool Area (Sq. Ft.)

Related Documents:

to the room side of the sleeve to allow for the installation of a 13³ ₄ in. (35 cm) PTAC/ PTHP into an 11¹ ₂ in. (29.2 cm) wall sleeve. 4396600 Lateral duct adapter - attaches to the PTAC/PTHP and provides a transition to direct up to 35% of the total airflow to a secondary room, either left or right of the PTAC/PTHP. Kit

6 www.amana-ptac.com Nomenclature 1,2,3 4,5 6 7 8,9 14,15 Basic Model Type Engineering PTC Standard Cooler PTAC Major & Minor Revisions PTH Standard Heat Pump PTHP HEH High- ‐Efficiency Heat Pump Features Code * 32C High-Efficiency R32 Cooler PTAC A Standard Model PMC DigiAIR Cooler PTAC C Corrosion Protection (Seacoast)

6 www.amana-ptac.com Nomenclature. 1,2,3 4,5 6 7 8,9 14,15 Basic Model Type Engineering PTC Standard Cooler PTAC Major & Minor Revisions PTH Standard Heat Pump PTHP HEH High- ‐Efficiency Heat Pump Features Code * A PMC DigiAIR Cooler PTAC C PMH DigiAIR Heat Pump PTAC D Nominal Cooling Capacity* L 07 7,000 BTU/h 60 Hz H

6 www.amana-ptac.com Nomenclature. 1,2,3 4,5 6 7 8,9 14,15 Basic Model Type Engineering PTC Standard Cooler PTAC Major & Minor Revisions PTH Standard Heat Pump PTHP HEH High- ‐Efficiency Heat Pump Features Code * A PMC DigiAIR Cooler PTAC C PMH DigiAIR Heat Pump PTAC D Nominal Cooling Capacity* L 07 7,000 BTU/h 60 Hz H

6 www.amana-ptac.com Nomenclature 1,2,3 4,5 6 7 8,9 14,15 Basic Model Type Engineering PTC Standard Cooler PTAC Major & Minor Revisions PTH Standard Heat Pump PTHP HEH High- ‐Efficiency Heat Pump Features Code * DRY Dehumid Cooler PTAC A Standard Model PMC DigiAIR Cooler PTAC C Corrosion Protection (Seacoast)

Table 2. Wiring terminal references for non-Excel 10/12 devices signal T7460A terminal T7460B terminal T7460C terminal Excel 800 XF82x terminal (example) Excel 500 XF52xB terminal (example) Excel 500 XFL52x terminal (example) Excel 100 terminal (example) Excel 50 terminal (example) Excel 20 terminal (example) CPO-FB22344R terminal (example)

2 www.amana-ptac.com MC-DPTAC Energy Efficiencies: With EERs up to 11.7 and COPs up to 3.4, our unit's high efficiencies may qualify you for many of the rebates offered by electrical power companies. Quiet Operation: Our PTAC has been redesigned to be the quietest PTAC we've ever built. The unit's state-of-the-art design and construction provide a quiet environment, allowing .

all ptac units ship complete with the standard power cord for that model (7K, 9K and 12K 3.0 kW and 15K 5.0 kW). If you want to adjust the heater size on any PTAC unit simply unplug the attached power cord and connect the desired size. It is important to ensure that all wiring and building connections are sized properly for the