TESTIDEAL RANGEADJUSTMENT REQUIREDFree Chlorine1.0 - 3.0 ppmTurn output dial up to increase,down to decrease -OR- increaseor decrease pump filtration time.pH7.2 - 7.6Alkalinity80 - 120 ppmSaltAquaLogicAutomation and ChlorinationToo high - add muriatic acidToo low - add soda ash.Add baking soda to increase.Add acid as required to decrease.2700 - 3400 ppm Add salt as required to increase.Stabilizer60 - 80 ppmAdd cyanuric acid to increase.Calcium200 - 400 ppmAdd calcium to increase.Drain and add water to decrease.Electrolytic Cell inspect & cleanRefer to section in manual.(actuator, cell & remote display not included - order separately)Operation Manualfor modelAQL-P-4GLDLINEGC ON TROLSNorth Kingstown, RI 02852 USA092032KCopyright 2008 Goldine ControlsLDLINEC ON TROLSwww.goldlinecontrols.com888-921-7665

LIMITED WARRANTY Goldline warrants its Aqua Rite, Aqua Rite Pro, Aqua Trol, Aqua Logic and Pro Logic products(products with Goldline part numbers starting with AQ-RITE-, AQ-RT-PRO, AQ-TROL-, AQ-LOGIC-, AQL-P-, AQL-PS-,AQL-CL-, PL-P-, PL-PS-, and HPC-2) to be free from defects in material or workmanship, under normal use and service:IMPORTANT SAFETY INSTRUCTIONSWhen using this electrical equipment, basic safety precautions should alwaysbe followed, including the following: READ AND FOLLOW ALL INSTRUCTIONS!WARNING: Disconnect all AC power during installation.!WARNING: Water in excess of 100 degrees Fahrenheit may behazardous to your health.!WARNING: To reduce the risk of injury, do not permit children touse this product unless they are closely supervised at all times.A green colored terminal marked “Earth Ground” is located inside the wiringcompartment. To reduce the risk of electric shock, this terminal must beconnected to the grounding means provided in the electric supply servicepanel with a continuous copper wire equivalent in size to the circuitconductors supplying the equipment. One bonding lug for US models (two for Canadian models) is provided on theexternal surface. To reduce the risk of electric shock, connect the localcommon bonding grid in the area of the swimming pool, spa, or hot tub tothese terminals with an insulated or bare copper conductor not smaller than 8AWG US / 6 AWG Canada. All field installed metal components such as rails, ladders, drains, or othersimilar hardware within 3 meters of the pool, spa or hot tub shall be bondedto the equipment grounding bus with copper conductors not smaller than8 AWG US / 6 AWG Canada. SAVE THESE INSTRUCTIONSFor three years from the date of the initial system installation on private, residential swimming pools within the USA or Canadaand one year from the date of initial system installation on commercial installations, installations outside of the USA or Canadaand for any replacement parts or accessory products, provided they are installed in accordance with the Goldline installationinstructions and specifications provided with the product. If written proof of the date of the initial system installation is notprovided to Goldline, the manufacturing datecode on the Aqua Rite, Aqua Rite Pro, Aqua Trol, Aqua Logic and Pro Logicelectronics unit will be the sole determinant of the date of the initial system installation.For residential installations in USA or Canada: If a product is defective in workmanship or materials and is removed and returnedfreight prepaid within three (3) years after the date of the initial system installation, Goldline will, at its option, either repair orreplace the defective product and return it freight prepaid.For commercial installations, installations outside the USA and Canada, and accessory products and replacement parts: If aproduct is defective in workmanship or materials and is removed and returned freight prepaid within one (1) year after the dateof the initial system installation, Goldline will, at its option, either repair or replace the defective product and return it freightprepaid.Contact any Goldline dealer or contact Goldline at 61 Whitecap Drive, North Kingstown, RI 02852 for warranty service. Thecosts incurred in removal and/or reinstallation of the product are NOT covered under this warranty. Some states do not allowlimitations on how long an implied warranty lasts, so the above limitation may not apply to you.WARRANTY EXCLUSIONS:1.Material supplied or workmanship performed by others in process of installation.2.Damage resulting from improper installation including installation on pools larger than the product rating.3.Problems resulting from failure to operate the product(s) in accordance with the recommended instructions containedin product’s owners manual(s).4.Problems resulting from failure to maintain pool water chemistry in accordance with the recommendations in theowners manual(s).5.Problems resulting from tampering, accident, abuse, negligence, unauthorized repairs or alternations, fire, flood,lightning, freezing, external water, degradation of natural stone used in or immediately adjacent to a pool or spa, waror acts of God.DISCLAIMER. THE EXPRESS LIMITED WARRANTY ABOVE CONSTITUTES THE ENTIRE WARRANTY OFGOLDLINE WITH RESPECT TO ITS POOL AUTOMATION AND CHLORINATION PRODUCTS AND IS IN LIEUOF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITYOR FITNESS FOR A PARTICULAR PURPOSE. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, ANDYOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE. IN NO EVENT SHALL GOLDLINEBE RESPONSIBLE FOR ANY CONSEQUENTIAL, SPECIAL OR INCIDENTAL DAMAGES OF ANY NATUREWHATSOEVER, INCLUDING, BUT NOT LIMITED TO, PERSONAL INJURY, PROPERTY DAMAGE, DAMAGE TOOR LOSS OF EQUIPMENT, LOST PROFITS OR REVENUE, COSTS OF RENTING REPLACEMENTS, AND OTHERADDITIONAL EXPENSES, EVEN IF THE SELLER HAD BEEN ADVISED OF THE POSSIBILITY OF SUCHDAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OF LIMITATION OF INCIDENTAL ORCONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.NO WHOLESALER, AGENT, DEALER, CONTRACTOR OR OTHER PERSON IS AUTHORIZED TO GIVE ANYWARRANTY ON BEHALF OF GOLDLINE.THIS WARRANTY IS VOID IF THE PRODUCT HAS BEEN ALTERED IN ANY WAY AFTER LEAVING THE FACTORY.36

Table of Contents35System OverviewBlock Diagram.Automation.Chlorination.Default Display.1122Manual SystemOperationFilter Pump.Lights and Aux Outputs.Pool/Spa Valves.Service.3444Automatic SystemOperation(Programming)Using the Programming Buttons.Programming Menu Flow Chart.Settings Menu.Timers Menu.Configuration Menu.5671013Quick “How To”GuideOperate the Spa - Manually.Operate the Spa - Automatically.Set the Heater Temperature.Set the Chlorinator Output .Start/Stop Superchlorination.Program a Timeclock.Program a Countdown Timer.Enter/Exit Service Mode.2222222223232324Chlorinator Operation/Water ChemistrySaturation Index.Salt Level.Type of Salt.How to Add or Remove Salt.25262626System MaintenanceServicing and Cleaning the Turbo Cell. 29Winterizing. 29Spring Startup. 29Troubleshooting &Diagnostic InformationService Mode .Check System Indicator.Diagnostic Menu.Chlorinator Diagnostics.Instant Salt.Flow Switch.Cell, Water, Air, Solar Temperature.Software Revision.WarrantyAqua Logic Warranty. 363031323232323333

System OverviewThe following statement is applicable if any of the wireless accessories are connected to the Aqua Logicsystem.The Aqua Logic is a multifunction pool controller used to fully manage your pool/spa system. The AquaLogic can control pumps, valves, lighting, heaters, and chlorination. Although the Aqua Logic is easy touse, it is important to completely read through this operating manual before attempting to operate thecontrol.FCC Statement(Compliance Statement, Part 15.19): This device complies with Part 15 of the FCC Rules. Operation issubject to the following two conditions: (1) This device may not cause harmful interference, and (2) thisdevice must accept any interference received, including interference that may cause undesired operation.WARNING (Part 15.21): Changes or modifications not expressly approved by the party responsible forcompliance could void the user’s authority to operate this equipment.OptionalWireless BaseReceiverIndustry Canada StatementOptionalRemote DisplayKeypadThe term “IC” before the certification/registration number only signifies that the Industry Canada technicalspecifications were met.Main DisplayKeypadInterference(maximum of three)Filter PumpLightsAux 1WaterTemperatureSensors120/240VRelaysAux 2Pool/Spa Suction &Return ValvesAirSolar24V ValveActuatorsValve 3This equipment has been tested and found to comply with the limits for a Class B digital device, pursuantto Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmfulinterference in a residential installation. This equipment generates, uses, and can radiate radio frequencyenergy and, if not installed and used in accordance with the instructions, may cause harmful interference toradio communications. However, there is no guarantee that interference will not occur in a particularinstallation. If this equipment does cause harmful interference to radio or television reception, which can bedetermined by turning the equipment off and on, then the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna.Increase the separation between the equipment and the receiver.Connect the equipment into a power source on different circuit than the receiver.Consult the dealer or an experienced radio/TV technician for help.HeaterOptionalFlow SwitchOptionalChlorinator Cell240 VACPowerCircuit BreakerSubpanelNOTE: This manual assumes that the Aqua Logic has been wired and configured according to the Installation Manual. Aspects of the Aqua Logic that pertain to system setup are not covered in this manual.AutomationThe AQL-P-4 can control up to 4 high voltage (120/240V) pieces of equipment, up to 3 automatic valveactuators, and a conventional and solar heater. Both manual and automatic (programmed) operation areavailable. All of the control functions can be programmed at a display/keypad which is part of the main unit(typically located near the pool equipment) or at one or more remote display/keypads.134

Solar SensorShort circuit Air Sensor94ºF Water SensorOpen circuit Cell Temp Sensor77ºF No functionMove to previous/next menu item No functionMove to previous/next menu item No functionMove to previous/next menu item No functionMove to previous/next menu itemAvailable displays depend on configuration. If the sensor appears to operating properly,then the temperature will be displayed. If this temperature is not correct then check theplacement of the sensor. If the problem is not placement related, then the sensor will, mostlikely, require replacement. If the display is “Open Circuit” or “Short Circuit” then check thewiring to the sensor and also make sure that the wires are secure in the terminal block in theAqua Logic main unit. No functionMove to previous/next menu item No functionMove to previous/next menu item No functionMove to previous/next menu item No functionMove to previous/next menu itemAvailable displays depend on configuration. If you call the Goldline Technical ServiceDepartment for assistance, they may ask for the software revisions of both the main unit andeach of the display/keypads or other devices that are attached to the system. Note that it ispossible that different display/keypads have different software revision levels. For thisreason, it is advisable to check this diagnostic menu item on every display.With the use of the optional AQL-CL chlorination kit, the Aqua Logic is also an automatic chlorine generation system for pool and/or spa sanitization. If enabled (see Configuration Menu), this operation requiresa low concentration of salt (sodium chloride) in the pool/spa water. The Aqua Logic automatically converts the salt into free chlorine which kills bacteria and algae in the pool/spa. Chlorine will revert back tosodium chloride after killing bacteria. These reactions will continuously recycle, virtually eliminating theneed to add sanitizing chemicals to your pool/spa. The only time you may need to add more salt to thepool/spa is when water is replenished due to backwashing, draining, or splashing (not evaporation).The Aqua Logic is designed to handle the purification needs of most residential swimming pools up to40,000 gallons (150,000 liters), or the needs of most commercial pools up to 25,000 gallons (95,000liters). Check local codes for other restrictions. The actual amount of chlorination required to properlysanitize a pool varies due to bather load, rainfall, temperature, and the pool’s cleanliness.For pools larger than 40,000 gallons, the Aqua Logic can control one or more Goldline Aqua Rite chlorinators to supplement chlorine production.NOTE: Before installing this product as part of a saline water purification system in a pool or spa usingnatural stone for coping or for immediately adjacent patios/decking, a qualified stone installation specialistshould be consulted regarding the appropriate type, installation, sealant (if any) and maintenance of stoneused around a saline pool with electronic chlorine generator in your particular location and circumstances.Default DisplayTurn power on at the main panel and turn the Aqua Logic control power circuit breaker on. The keypadwill show the default display. The default display alternates between the day/time, air and pool (or spa)temperature, pool/spa sanitizer setting, and salt level. Under certain circumstances, additional displaysmay be added to the default menu to inform you about system operation. Refer to the Programming MenuFlowchart on page 6 to view all possible displays. The Aqua Logic will automatically scroll through all ofthe available default menu displays or you can press “ ” or “ ” to manually scroll.Saturday11:45APool/Spa Service 6B Spa SoftwareRemote A r1.00 RF Base Softwarer1.20 ID:1234 Display Softwareremote-08 r3.10 Main SoftwareRevision 2.40Chlorination33MenuFilterLightsAux 1Aux 2 2

Diagnostic Menu 23.45Set Day and 6.75ATimeWednesday84 F3200PPM10:37P(Pool/Spa/Spillover)Filter PumpFilterCheck SystemIndicatorIf the current (amps) display is 0.00A, then the chlorinator is operating normally but is in theoff part of its normal operating cycle. Simply press either the “ ” or “-“ key to start a newcycle.(On/Off)Pool/SpaLightsThe Aqua Logic periodically reverses the polarity of the voltage applied to the cell in orderto automatically clean off any calcium deposits. It is important that you check the chlorinatoroperation in both polarities. To do this, press either the “ ” or “-“ buttons and the chlorinatorwill turn off, wait for 15 seconds and then turn on in the opposite polarity.(On/Off)LightsServiceAux 1Aux 2Service ButtonAux 1(On/Off)If a conventional or solar heater is operating, it is likely that the temperature of the water atthe cell is higher than the pool/spa water temperature displayed on the Aqua Logic defaultdisplay.Aux 2(On/Off)(main display only)Filter PumpSingle Speed Filter Pump: If the pump is currently off, press the FILTER button to turn on the pump.Pressing the FILTER button again will turn off the pump. However, if there is a heater in the system, andit is operating, and the “Heater Cooldown” feature is enabled (Configuration Menu) then: when you pressthe FILTER button to turn off the filter, only the heater will turn off, the Filter LED will flash and the displaywill indicate “Heater Cooldown”. At this point the filter pump will automatically turn off after 5 minutes ofheater cooldown operation. If you want to override the heater cooldown, simply press the FILTER buttonagain to turn off the filter pump.Two Speed Filter Pump: If the pump is currently off, simply press the FILTER button to turn on highspeed operation of the filter pump. The “Filter” LED will illuminate continuously. Pressing the FILTERbutton again will switch to low speed operation and the “Filter” LED will flash. If you attempt to switch tolow speed shortly after turning on high speed the filter pump will automatically remain in high speed for 3minutes before switching to low speed to allow the pump to prime and establish normal water flow.Freeze Protection: This function protects the pool, plumbing, and equipment against freeze damage. IfFreeze Protection is enabled and the AIR temperature sensor falls below the preset freeze protectiontemperature (see Filter Pump Configuration), the Aqua Logic will turn on the filter pump to circulate thewater.3Instant Salt3200 PPM ( save) Press to load the “Instant salt” into the averaged salt displayMove to previous/next menu itemThis display will be shown only if the chlorinator is enabled. This display shows “InstantSalt” or “Instant Minerals” (if Chlor. Config. is set for “Display Minerals”). The “InstantSalt” is calculated based on the voltage, current (amps), and water temperature at the cell.This is different than the “average salt” value which is displayed as part of the default menu.There are a number of reasons why instant and average salt readings may differ. Some ofthese include salt having just been added to the pool and not yet thoroughly mixed, calciumbuildup on the cell, and the cell aging.Flow SwitchFlow Valve 3IndicatorPress to switch chlorinator operation to opposite polarity (15 second delay)Move to previous/next menu itemThis display will be shown only if the chlorinator is enabled. For the chlorinator to beoperating, several other things must be happening: the filter pump must be running, the flowswitch must be detecting flow, the chlorinator setting must be set greater than 0%, the watertemp

LIMITED WARRANTY Goldline warrants its Aqua Rite, Aqua Rite Pro, Aqua Trol, . This manual assumes that the Aqua Logic has been wired and configured according to the Instal- lation Manual. Aspects of the Aqua Logic that pertain to system setup are not covered in this manual. Automation The AQL-P-4 can control up to 4 high voltage (120/240V) pieces of equipment, up to 3 automatic valve .

Related Documents:

Dawn Roush, Env Mgr 14 Kevin Goodwin, Aqua Bio Spl 13 Bill Keiper, Aqua Bio Spl 13 Sam Noffke, Aqua Bio 12 Lee Schoen, Aqua Bio 11 Elizabeth Stieber, Aqua Bio 11 Kelly Turek, Aqua Bio 12 Chris Vandenberg, EQA 11 Jeff Varricchione, Aqua Bio 12 Matt Wesener, Aqua Bio 11 Marcy Knoll Wilmes, Aqua Bio Spl 13

provided to Goldline, the manufacturing datecode on the Aqua Rite, Aqua Rite Pro, Aqua Trol, Aqua Logic and Pro Logic electronics unit will be the sole determinant of the date of the initial system installation. For residential installations in USA or Canada: If a product is defective

Refer to www.goldlinecontrols.com for latest manual revisions, additional information and helpful service. Aqua Pod Handheld Remote Control for Aqua Logic and Automation and Chlorination Operation Manual Li Ion Batte

LIMITED WARRANTY (effective 04/01/09) Hayward/Goldline warrants its Pro Logic and E-Command pool automation products as well as its Aqua Rite, Aqua Rite Pro, Aqua Plus and SwimPure chlorination products . (Settings Menu / Pool Heater & Spa Heater). The filter pump is running. If the pool has solar heat and the solar priority feature .

Valves (use standard Hayward, Pentair/Compool, or Jandy valves) Additional valve actuators Accessory Products - Order Separately AQL-CL Chlorination kit AQL2-Wx-PS-4 Wired Remote Display (see note 1) AQL2-Wx-PS-8 Wired Remote Display (see note 2) AQL2-Wx-PS-16 Wired Remote Displ

provided to Goldline, the manufacturing datecode on the Aqua Rite, Aqua Rite Pro, Aqua Trol, Aqua Logic and Pro Logic electronics unit will be the sole determinant of the date of the initial system installation. For residential installations in USA or Canada: If a product is defective

The Aqua-Hot System is powered by TribridHot technology and uses one or a combination of the following heat sources: 1. The Burner: This is the Aqua-Hot’s most powerful heat source. The burner must be on for the Aqua-Hot to pro-vide continuous hot water. The burner must also be on for the Aqua-Hot to provide interior heat. 2.

ASTM E1050 standard was updated in 1998 to include changes in the required physical dimensions of the tube. Specifically, the tube length was said to be increased to be sufficiently long to meet the requirement that plane waves be fully developed before reaching the microphones and test specimen. Further, a minimum of three tube diameters was specified between the sound source and the nearest .