Pump StartTraining Booklet

You have been given this resource because your healthcare professional haschosen this product as a suitable treatment option for you.Always read the label and use only as directed. Read the warnings available onwww.amsldiabetes.com.au/resources before purchasing.

Table of ContentsWelcome to Pumping with Tandem1My t:slim X2 Insulin Pump Settings2Personal Profiles2Pump Alert Settings3Quick Reference Guides4View Status4Personal Profiles5Instructions for Drawing Insulin from Cartridge into Syringe6Instructions for Filling the Cartridge6Load a CartridgeTandem AutoSoft 90 Infusion Set t:lock78Tandem AutoSoft 30 Infusion Set t:lock9Tandem VariSoft Infusion Set t:lock10Tandem TruSteel Infusion Set t:lock11Bolus12Extended Bolus13Setting a Temp Basal Rate14Stop and Resume Insulin Delivery15diasend Personal Uploader - Getting Started Guide16Flying with your t:slim X2 Insulin Pump19t:slim X2 System Specifications20t:slim X2 System Options and Settings21t:lock Infusion Sets & Cartridges23

Welcome toPumping with TandemHi there!Thank you for choosing the t:slim X2 Insulin Pump to help manage your diabetes.This booklet will provide you with some helpful resources to get you started. For moreinformation, please refer to your t:slim X2 Insulin Pump User Guide.If you have any concerns about your dosage, Blood Glucose (BG) levels or testpositive for ketones, please contact your healthcare professional or emergencydepartment, as we are unable to advise on these issues or any clinical aspect of yourdiabetes management.If you need technical assistance with your insulin pump, we have adedicated 24/7 Australian-based Customer Care Team available on1300 851 056.The Tandem t:simulator app can help your family/support team get familiar with yournew pump! Search for the t:simulator on the App Store or Google Play.10:20100%B5 Mar 2017400223501830014250200101506100502INSULIN ON BOARD:OPTIONS1235 u10.5mmol/L3HRS1.1 u 1:09 hrsBOLUS

Let’s Get Started!

My t:slim X2 Insulin PumpSettingsYou have now received your new t:slim X2 Insulin Pump. This document will assistyou with entering all of your settings provided by your healthcare professional intoyour new t:slim X2 Insulin Pump.Personal ProfilesTo begin, select:Options My Pump Personal Profiles NewProgram No 1. ‘Weekday’Bolus SettingsTimed arbRatioTargetBGIOBDurationhrsMaxBolusCarbsooOnOff

Program No 2.Bolus SettingsTimed ump Alert SettingsSelect:Options My Pump Alert Settings Pump AlertsLow InsulinAuto-On/OffunitsoOffoOn*Set to Auto-On by defaultIn order to begin using your new t:slim X2 Insulin Pump, you must manually enter the settings discussed withyour healthcare professional (or directly from your previous insulin pump if applicable) into your new t:slim X2Insulin Pump using the information you have recorded on the previous pages.Contact your healthcare professional team if you have any questions about the settings you are entering.Failure to use settings determined by your healthcare professional team will likely result in incorrect insulindelivery.If you require technical assistance with your insulin pump, please call our AMSL Diabetes Customer CareTeam on 1300 851 056.IMPORTANT: These instructions are simplified to supplement training by your healthcare professional. Beforeyou begin, you should carefully read the t:slim X2 Insulin Pump User Guide and any inserts that come with yoursystem.3

View Statuson the t:slim X2 Insulin PumpThe instructions below are provided as a reference tool for those who are already familiar with the use of an insulin pump and with insulin therapy in general.Not all screens are shown.5.53Tap the Insulin Gauge in theupper right corner of the HomeScreen.Your t:slim Insulin Pump willdisplay the name of your activeprofile, your current basal rate, thetime and amount of your last bolus,and your current insulin-to-carbratio.If you have an active ExtendedBolus, this screen will show howmuch insulin has been deliveredout of the total amount requested.Scroll down by tapping theDOWN ARROW to display yourcurrent Correction Factor, BloodGlucose (BG) Target, InsulinDuration, and whether or not youare entering boluses based onCarbohydrates.Explanation of IconsThe following icons may appear in the areas to the leftor right of the time and date on your pump’s Home Screen.10:20 AMApril 6, 2015100%235 uBOLUSOPTIONSA system reminder, alert, error, or alarm is active. Unlockscreen to view.A bolus is being delivered.All insulin deliveriesare stopped.Basal insulin is programmedand being delivered.A basal rate of 0 u/hris active.A temporary basalrate is active.A temporary basal rateof 0 u/hr is active.INSULIN ON BOARD (IOB)Units41.1 uTime Remaining1:09 hrs

Personal Profileson the t:slim X2 Insulin PumpThe instructions below are provided as a reference tool for those who are already familiar with the use of an insulin pump and with insulin therapy in general.Not all screens are shown.1.10:20 AMBApril 6, 2015100%235 u2.BOLUSOPTIONSINSULIN ON BOARD (IOB)Units1.1 uTime RemainingBACKMyPumpProfile1BACKSTOP INSULINEditPersonalProfilesEditMy PumpActivateAlert SettingsAlerts& RemindersActivateLoadDuplicateMy CGMPumpSettingsDuplicateTemp RateDeletePump InfoDelete1:09 hrsTap OPTIONS.4.3.Options1ProfileBACKTap My Pump.Personal ProfilesNEW5.BACKProfile 1ONProfile 2OFFActivateProfile 3OFFDuplicateProfile 4OFFDeleteTap Personal Profiles.6.Profile 1Profile 1BACKTimed Settings 9:00a12:00 - TCARB1206.7TARGET BGBGBolus SettingsDuplicate65 hrsDURATIONDeleteTap Edit to edit or viewyour settings.Tap the name of the Personal Profileto View/Edit.1:101210 uMAX BOLUSONCARBSTap your current settings to seethe other segments of your day.Turn ON to activate bolus calculator.7.BACKEditADD12:00 ess0.75to Setu/hrUpCARB TARGET BG3:00 AM1:31:508.1:156.0140CARB TARGET BG9.Confirm Settings?BasalCorrection FactorCorrection FactorActivatePressto SetUp1u:50mg/dLCarb RatioCarb RatioDuplicatePress toSet Up1u:10gTarget BGTarget BGDeletePressto SetUp120mg/dLNO0.75 u/hr1u:2.850 mg/dLmmol/L1u: 10g6.7 mmol/L120mg/dL7:007:30 AM1:3.51:45CORRECT1:9.41:136.5110YESCARB TARGET BGTap the time segment you wishto edit.If not all segments are visible,tap the arrow to scroll down.Tap Basal, Correction Factor, CarbRatio, or Target BG to set up, thentap DONE.When you are finished, tap SAVE.Confirm settings. Recent changesappear in orange.Tap YES to confirm.5

Instructions for Drawing Insulin from Cartridge into SyringeUse proper clean technique while performing the following:1.2.3.4.5.6.7.8.Inspect the needle and syringe package for any signs of damage.Discard any damaged product.Wash your hands thoroughly.Remove the needle and syringe from their packaging. Securely twist needleonto syringe. Safely remove protective cap from needle by pulling outward.Insert needle into the prefilled insulin container (insulin penfill or vial).Slowly pull back the plunger to the desired amount of insulin.Once filled, Remove syringe from the prefilled insulin container.Tap the syringe so that any air bubbles rise to the top. Then slowly push theplunger upwards, forcing any air bubbles out of the filling syringe.Check the syringe for air bubbles and do one of the following:» If there are air bubbles present, repeat step 7 onwards.» If no air bubbles are present, you are ready to move on to the next step.Instructions for Filling the CartridgeIf instructed to load a filled cartridge,perform the following before loadingthe cartridge onto the pump.Refer to the User Guidethat came with yoursystem for detailedinstallation instructions.1.Inspect the cartridge package for any signs of damage. Discard anydamaged product.2.Open the package and remove the cartridge.3.Hold the cartridge upright and gently insert the needle into the white insulinfill port on the cartridge (see image E). The needle is not intended to go allthe way in, so do not force it.4.Keeping the syringe vertically aligned with the cartridge, and the needleinside the fill port, pull back on the plunger until it is fully retracted(see image F). This will remove any residual air from the cartridge.Bubbles will rise toward the plunger.5.Make sure the needle is still in the fill port and release the plunger. Pressurewill pull the plunger to its neutral position but it will NOT push any air backinside the cartridge (see image G).6.Withdraw the needle from the fill port.7.Turn the syringe upright and pull down on the plunger (see image H).Flick the barrel to make sure that any air bubbles rise to the top.8.Gently press on the plunger to remove air bubbles until insulin fills the needlehub and you see a drop of insulin at the tip of the needle (see image I).9.Re-insert the needle in the fill port and slowly fill the cartridge with insulin(see image J). It is normal to feel some back pressure as you slowlypress on the plunger.10. Maintain pressure on the plunger while you remove the needle from thecartridge. Check the cartridge for leaks. If you detect insulin leaking,discard the cartridge and repeat entire process with a new cartridge.11. Always dispose of used needles, syringes, cartridges, and infusion setsfollowing your community’s regulation.6

Load a Cartridgeon the t:slim X2 Insulin PumpThe instructions below are provided as a reference tool for those who are already familiar with the use of an insulin pump and with insulin therapy in general.Not all screens are shown.2.1.OptionsBACK3.LoadBACKLoadChange CartridgePump HistoryFill TubingCGM HistoryFill CannulaOnSite ReminderFrom the Options menu, tapthe Down Arrow, then tapLOAD.4.DONEFrom the Load menu, tapChange Cartridge. Screen willdisplay that all insulin deliverieswill be stopped.Disconnect the infusion setfrom your body and tap NEXTto continue.Tap NEXT to continue.Tap YES to continue.5.6.8.7.Fill TubingInsert a new set and connect tothe filled tubing.STARTFill TubingRemove the used cartridge.Install filled cartridge. TapUNLOCK icon when completedPress NEXT to fill the cannula withinsulin.0uAmount FilledCLOSEVerify that the infusion set isdisconnected from your body.Connect the infusion set tubingto the tubing connector on thecartridge. Tap NEXT.9.BACKFill CannulaEdit Fill AmountFill CannulaAmount FilledHold the pump vertically toensure any air in the cartridgewill be dispelled first.Tap STOP after 3 drops ofinsulin are seen at the end ofthe infusion set tubing.Tap START. The pump willbeep and vibrate regularly whilethe tubing is being filled.Verify that drops are seen andtap DONE.10.11.BACK0.7 uSTARTSite ReminderSite ReminderScheduled Day0uScheduled TimeOFFSAVEONSelect amount needed forcannula fill. Refer to yourinfusion set instructions for usefor proper cannula fill amount.Tap START.Tap Fill Cannula.Insert a new infusion set andconnect filled tubing to site,then tap NEXT.NOTE: If you are using a steel needleinfusion set, there is no cannula fill.Skip to 10.12.Resume Insulin now?RESUMING INSULINThis will resume your basal andthe active personal profile.Friday5:00 PMEdit ReminderTap Edit Fill Amount.NEXTAfter the cannula fill iscomplete, you can set a SiteChange reminder.Tap SAVE if correct. Tap EditReminder if settings need to bechanged.CLOSERESUMELoad screen is displayed.Tap DONE. A reminder to testBG in 1 to 2 hours will display.RESUMING INSULIN screen istemporarily displayed.Tap RESUME.7

Tandem AutoSoft 90 Infusion Set t:lockQuick Reference GuideAutoSoft 90 combines the insertion device and infusion set into a single sterile, portable unit. Ensureyou wash and dry your hands thoroughly and clean the area with a disinfectant wipe before followingthe steps below.1Check the tamper-proof sealand sterile paper. Do notuse device if the seal or paperhas been broken. Pull thered tape to remove the seal.5Connect AutoSoft 90 to a reservoir/cartridge and the pump. Prime theinfusion set according to the pumpmanufacturer’s instructions for use.Ensure there are no air bubbles inthe tubing of AutoSoft 90. 9Place AutoSoft 90 on your clean,dry insertion site and press theround indentations on each sideof the insertion mechanism atthe same time.CAUTION: before positioningAutoSoft 90 over clean insertionsite, place the tubing in the slotto ensure that the tubing is notcaught underneath the deviceduring insertion.82Pull off the sterile paper.Do not touch the spring.6Pull up gently to remove theadhesive backing paper, whichwill come off in a single piece.10Push in gently on the centre ofthe insertion mechanism tosecure adhesive on the skin.3Firmly press the three raised dotson each side of the lid with onehand and pull with the other hand.*CAUTION: be careful not to bendthe introducer needle of theAutoSoft 90 when removing the lid.7Place fingers on linedindentations when loading theinsertion mechanism. Pullspring up until you hear a“click.”11Grasp centre of insertionmechanism. Pull back gentlyand slowly. Fill the empty space inthe cannula with the followingprime:U-100 insulin6 mm: 0.3 units (0.003 mL)9 mm: 0.5 units (0.005 mL)4Carefully unwind tubing and placea finger on the adhesive backingpaper when fully unwinding thetubing. 8Carefully remove the needleguard by gently twisting andthen pulling it. Secure tubing inslot.12Put lid securely in place untilyou hear a “click.” With lidproperly connected, AutoSoft90 can be disposed of safely.* IMPORTANT NOTE: if the infusion set is not securely placed in insertion device with needle pointing straight ahead prior to insertion, pain or minor injury may occur. To avoid this, please ensure that the steps are donegently, in order not to loosen/remove the infusion set by accident. Please note: this guide only illustrates some of the steps to follow when inserting AutoSoft 90 and it is not a substitute for reading the instructions foruse and cautions, which come with the product. When initially trying a new infusion set, we recommend this to be done under the supervision of a healthcare professional. Do not touch the AutoSoft 90 introducer needle when unwinding the tubing. Be careful not to pull too hard when the tubing is fully released. You could accidentally remove the infusion set from the introducer needle. When priming the infusion set, hold AutoSoft 90 with the needle pointing down to ensure that the insulin does not come into contact with the adhesive backing paper.

Tandem AutoSoft 30 Infusion Set t:lockQuick Reference GuideAutoSoft 30 combines the insertion device and infusion set into a single sterile, portable unit. Ensureyou wash and dry your hands thoroughly and clean the area with a disinfectant wipe before followingthe steps below.1Check the tamper-proof sealand sterile paper. Do notuse device if the seal or paperhas been broken. Pull thered tape to remove the seal.523Pull off the sterile paper.Do not touch the spring.6Hold on the lined indentationswith one hand and pull the lidoff with the other.*CAUTION: be careful not tobend or touch the AutoSoft 30introducer needle.74Place your fingers on the linedindentations on each side. Pullback the spring softly until youhear a “click”. The needleprotector will lift up or peel off. Donot touch or bend the needle.8 30 Immediately before insertion,carefully bend back theneedle protector and remove it.This will remove part of theadhesive backing paper. Besure the tape is not stuck on theintroducer needle.9Remove the backing paperunder the front end. Massagethe adhesive thoroughly on tothe skin.IMPORTANT: do not attemptto straighten the adhesive ifcurled.I NSERTION: place your indexfinger on the top release buttonand your thumb on the bottomrelease button. Position AutoSoft30 with its legs level (flat) on theskin to ensure an insertion angleof 30 . Maintain a 30 angle whileinserting and gently squeezeonce to insert in AutoSoft 30.10 Putthe lid back on fordisposal.Make sure that the cannulastays in place: put your fingergently on the clear windowwhile removing the insertiondevice and introducer needle.Pull it gently straight back.Secure the cannula with onefinger on the clear window.Carefully remove the backingpaper under the cannulahousing as shown.11Remove the circular protective cap. Prime infusion set until insulindispenses from the tip. Ensure there are no air bubbles in the tubing orAutoSoft 30. Consult your pump manufacturer’s instructions for use forproper priming procedures. Place a finger in front of the cannula housing andinsert the connector needle. Make sure the connector locks with a “click.”Fill the empty space in the cannula with the following prime:U-100 insulin:0.7 units (0.007 mL)* IMPORTANT NOTE: If the infusion set is not securely placed in the insertion device with the needle pointing straight ahead, pain or minor injury may occur during insertion. Please note: this guide only illustrates someof the steps to follow when inserting AutoSoft 30 and it is not a substitute for reading the instructions for use and cautions, which come with the AutoSoft 30 product. When initially trying a new infusion set, werecommend this to be done under the supervision of a healthcare professional.9

Tandem VariSoft Infusion Set t:lockQuick Reference GuideThis guide is a summary only and intended as a quick reference guide. Always refer to package insertfor full instructions and precautions.1Wash and dry your handsthoroughly. Likewise, clean theinsertion site and allow to dry.Use of adhesive wipes willclean the site and help theinfusion set to stay in place.5Secure the infusion set withone finger in front of the clearwindow. Squeeze releasesection of insertion set bypressing on ridged areas eitherside of the set. Remove theinsertion needle and dispose ofin a sharps container .102Hold the infusion set with onehand. Gently remove theadhesive backing paper withthe other hand.6Place one finger in front of theclear window. Gently removethe backing tape from theother half of the site. Hold skintight and gently press outsideof adhesive tape to secureedges.3Remove protective sleeve frominsertion needle.7Connect the line to thecartridge in the pump andprime the line. Ensure thereare no air bubbles.4Pinch skin tightly and insertneedle on 30 - 45 angle.8Connect the line to the siteand make sure an audible clickis heard and fill the cannula.NOTE: fill the empty space in thecannula with the following prime:U-100 insulin:0.7 units (0.007 mL)* IMPORTANT NOTE: if the infusion set is not securely placed in the insertion device with the needle pointing straight ahead, pain or minor injury may occur during insertion. Please note: this guide only illustrates someof the steps to follow when inserting VariSoft and it is not a substitute for reading the instructions for use and cautions, which come with the VariSoft product. When initially trying a new infusion set, we recommendthis to be done under the supervision of a healthcare professional.

Tandem TruSteel Infusion Set t:lockQuick Reference GuideThis guide is a summary only and intended as a quick reference guide. Always refer to package insertfor full instructions and precautions.1Wash and dry your handsthoroughly. Likewise, clean theinsertion site and allow to dry.Use of adhesive wipes willclean the site and help theninfusion set to stay in place.2Connect the line to thecartridge in the pump. Connectthe needle part of the infusionset to the line. Prime theinsulin through the line untilyou maintain a steady flow ofinsulin for six seconds. Ensurethere are no air bubbles.3Remove the tape and needleprotector from the infusion set.4Hold the infusion set just abovethe needle with one hand. Pinchthe skin at the injection site withthe other hand. Insert theinfusion set to its full length at a90º angle (straight in).5Ensure the fixation material isproperly placed andadequately covers the injectionsite.* IMPORTANT NOTE: if the infusion set is not securely placed in the insertion device with the needle pointing straight ahead, pain or minor injury may occur during insertion. Please note: this guide only illustrates someof the steps to follow when inserting TruSteel and it is not a substitute for reading the instructions for use and cautions, which come with the TruSteel product. When initially trying a new infusion set, we recommendthis to be done under the supervision of a healthcare professional.11

Boluson the t:slim X2 Insulin PumpThe instructions below are provided as a reference tool for those who are already familiar with the use of an insulin pump and with insulin therapy in general.Not all screens are shown.1.0BACKNEXTunitsCARBS2.BG0gramsAdd BGView CalculationTap 0 Grams to enter the carbs foryour bolus.Confirm Request?Your BG is Below TargetReduceReduce BolusBolus Calculation?Correction?Carbs38 gCurrentIOBBGCurrentUnits To BGDeliver5.EXTENDEDAdjusted FoodBACK56789 / 0CARBSBG38Add BGgramsView CalculationProfile3.83.580 1Tap Add BG to enter your bloodglucose. Be sure “mmol/L” isdisplayed above keypad whenentering BG values.NEXT6.Confirm Request?gramsDuplicate38 gCarbsBG3803.58 uUnits To Delivermg/dLNOView CalculationBOLUS INITIATED3.58 u4.7 mmol/L110mg/dLBG110Add BGTap NEXT to continue. Tapunits field to manually adjustrecommended dose.8.YESVerify the dose and tap YESto confirm.9.10:20 AMApril 6, 201580%B235 uBOLUSRequesting 3.58 u Bolus .ONOPTIONS3.58 uINSULIN ON BOARD (IOB)DELIVERTap DELIVER to deliver the foodbolus immediately.124Delete0uOFF3ActivateYESAdjusted mg/dLuDeliver 3.58 u Bolus?3.8BACKunitsIf a BG is entered that is below thetarget, but above 3.9 mmol/L, youwill be offered the option to reducethe bolus amount. To accept thatreduction tap YES otherwise tap NO.7.3.Tap DONE to continue.0u110 mg/dLNODONEgramsEnter desired value. Be sure“grams” is displayed above keypadfor food boluses.NOTE: If this button reads “units”, the Carbfeature is turned off in the active profile.4.Enter CarbsBACKUnitsThe Splash Screen confirmsdelivery has started.1.1 uTime Remaining1:09 hrsTo cancel the undelivered portionof the bolus, tap the Red “X” onthe BOLUS button on the HomeScreen, then tap YES to confirmcancelled bolus.

Extended Boluson the t:slim X2 Insulin PumpThe instructions below are provided as a reference tool for those who are already familiar with the use of an insulin pump and with insulin therapy in general.Not all screens are shown.1.0BACKNEXT2.BACKEnter CarbsunitsCARBSBG0Add BGgrams3.8BACK23456789CARBS38CorrectionNATap NEXT to continue, then tapYES to confirm.NOTE: If an above-target BG is entered,the correction bolus will not be extended.3.8NEXT6.Confirm Request?units60%3.8 uFoodBACKDELIVER NOWONOFFView CalculationTap DONE to continue.5.Extend Food Bolus?Add BGgramsEnter desired value. Be sure“grams” is displayed above keypadfor food boluses.NOTE: If this button reads “units”, the Carbfeature is turned off in the active profile.NEXTBG0Tap 0 Grams to enter the carbs foryour bolus.EXTENDED3.units1View Calculation4.DONEgramsDELIVER LATER40%Deliver Now60%Deliver Later40%3:30 hrsDurationDURATIONBACK3:30 hrsNEXTTap ON to extend the bolus.Deliver 3.8 u Bolus?Now2.28 uLater1.52 uDurationNONOTap NEXT to use default settingsor tap the DELIVER NOW andDURATION buttons and set yourdesired values, then tap NEXTto continue.Tap NEXT to continue.7.View Units8.BOLUS INITIATED2.28 u Now 1.52 u LaterTap YES to confirm.9.10:20 AMApril 6, 201580%B235 uBOLUSRequesting 2.28 u Bolus .OPTIONS3:30 hrsINSULIN ON BOARD (IOB)DELIVERThe Delivery Screen will confirmhow much insulin will be deliveredup front, how much will be deliveredover time, and the delivery duration.Tap DELIVER to start the bolus.YESUnitsThe Splash Screen confirmsdelivery has started.1.1 uTime Remaining1:09 hrsTo cancel the undelivered portionof the bolus, tap the Red “X” onthe BOLUS button on the HomeScreen, then tap YES to confirmcancelled bolus.13

Setting a Temp Basal Rateon the t:slim X2 Insulin PumpThe instructions below are provided as a reference tool for those who are already familiar with the use of an insulin pump and with insulin therapy in general.Not all screens are shown.1.10:20 AMAugust 28, 2017100%B235 u2.BOLUSOPTIONSINSULIN ON BOARD (IOB)Units1.1 uTime RemainingBACK3.BACKSTOP INSULINTemp RateMy PumpDurationLoadView UnitsTemp RateSAVE100%15 minTemp Rate1:09 hrsTap OPTIONS.4.OptionsBACKTap Temp Rate.80DONE5.Tap Temp Rate.Temp RateBACKSAVE6.BACKTemp RateSTART%123Temp Rate456Duration789View Units80%80%Temp Rate15 min6:30 hrsDurationView Units0Tap Duration. Using the onscreenkeypad, enter the desired length oftime for Temp Rate. Tap DONE.Using the onscreen keypad enterthe desired percentage. Tap DONE.NOTE: Current rate is 100%. An increaseis greater than 100% and a decrease isless than 100%. For example; 80% is 20%less than your normal basal rate.7.TEMP RATE STARTED80% / 6:30 hrsVerify settings and tap START.NOTE: To see the actual units to bedelivered tap View Units.8.10:20 AMTAugust 28, 2017100%235 u9.BACKOptionsSTOP INSULIN123My PumpLoadTemp RateINSULIN ON BOARD (IOB)UnitsThe TEMP RATE STARTED splashscreen is displayed.1.1 uTime Remaining1:09 hrsThe Screen Lock screen will bedisplayed with the orange “T” iconindicating a Temp Rate is active.NOTE: If a Temp Rate of 0% is currentlyactive, the status of insulin deliverydisplays a red “T”.14Time Remaining80%6:30 hrsNOTE: To stop Temp Rate at any time, tapOPTIONS, tap X. A confirmation screen willbe displayed. Tap STOP.

Stop and Resume Insulin Deliveryon the t:slim X2 Insulin PumpThe instructions below are provided as a reference tool for those who are already familiar with the use of an insulin pump and with insulin therapy in general.Not all screens are shown.Stop Insulin Delivery1.10:20 AMApril 6, 2015100%B235 u2.BACKOptions3.STOP INSULINBOLUSStop all deliveries now?My PumpOPTIONSLoadINSULIN ON BOARD (IOB)Units1.1 uTime RemainingThis will stop all insulin deliveries,including basal and any activebolus or temp rate.BACKTemp Rate1:09 hrsTap STOP INSULIN.Tap OPTIONS.STOPTap STOP.Resume Insulin Delivery4.10:20 AM100%April 6, 2015!235 uALL DELIVERIES STOPPEDTime Remaining6.Resume Insulin now?This will resume your basal andthe active personal profile.My CGMINSULIN ON BOARD (IOB)Tap OPTIONS.OptionsMy PumpOPTIONS1.1 uBACKRESUME INSULINBOLUSUnits5.Temp Rate1:09 hrsTap RESUME INSULIN.CLOSERESUMEConfirm by tapping RESUME.NOTE: Any temp rates or boluses activebefore you stopped delivery will not resume.It will resume your active personal profile.15

Glooko diasend PersonalUploader for t:slim X2Getting Started Guide1Log in or start a new account at www.diasend.comLog in with your user detailsor create an account if youare new to diasend.Username:Password:Note: Choose the2icon for your country of residence.Download the diasend Uploader softwareComplete the registration for a newaccount and download the diasend Uploader software in the final step ofthe registration process.Note: If you would like to install thediasend Uploader, you can accessthe installation file from your account.To do so, log into your account andgo to Tools.16

3Locate the installation file and run the fileDepending on your web browser, you may need to search forthe downloaded installation file, or you may just get a pop upwindow to run the file.If you are a PC user: look in your recent downloads folder.If you are a Mac user: look in the downloads folder inFinder.Note: Compatible operating systems:Windows 7, 8 and 10, macOS X 10.6-10.13Visit https://goo.gl/YdGju1 to stay up to date withany compatibility changes.4Start diasend UploaderOnce installed, double click on the diasend Uploader iconon your desktop to start the program.Note: Make sure you have restarted your computer beforestarting up diasend Uploader for the first time.5Connect your diabetes device cable to the computerConnect the microUSB cable to the computer. Once thecable is connected, wait a few seconds for the cabledrivers to be recognised, then connect to the t:slim X2Insulin Pump.Note: Make sure to use the cable that came with yourt:slim X2 Insulin Pump.17

6Log in at www.diasend.com to view your dataAll your uploaded data is presented in easy-to-readtables and graphs.The reports are divided into the following tabs:Glucose CGM Insulin Comparison Compilation7Share your data with a clinicYou can share your data with your healthcare provider by enteringtheir clinic ID, under the tabs Account admin and Share data.Don’t forget to click Update.8View your uploaded data in the diasend Mobile appDownload the app from Google Play or the App Store.Log in with your personal diasend ccount details or create a newaccount.With the diasend Mobile app you get: 18A summary of the latest uploaded dataEasy to grasp reports on your insulin intake and glucose levelsover time

Flying with yourt:slim X2 Insulin PumpIf you plan to travel by aeroplane with your insulin pump, some pre-planning may makeyour security screening go smoother. Your device is safe for use during air travel andcomplies with FAA wireless transmission standards. It is also designed to withstandcommon electromagnetic interference and can be safely carried through metaldetectors.However, your t:slim X2 Insulin Pump should NOT be put through machines thatuse X-rays, including airline luggage X-ray machines and full-body scanners.We recommend disconnecting at the infusion site and asking the security agent for analternative screening method. If you prefer to stay connected, you can notify the agentabout your pump and request to go through a standard metal detector wearing yourpump.It may be helpful to provide a letter from your healthcare professional, advising thatyour Insulin Pump should not be exposed to X-ray machines

Stop and Resume Insulin Delivery 15 diasend Personal Uploader - Getting Started Guide 16 Flying with your t:slim X2 Insulin Pump 19 t:slim X2 System Specifications 20 t:slim X2 System Options and

Related Documents:

3042f012 dpa pump 3042f022 dpa pump 3042f050 dpa pump 3042f052 dpa pump 3042f062 dpa pump 3042f080 dpa pump 3042f101 dpa pump 3042f102 dpa pump 12 volt 3042f110 dpa pump 3042f150 dpa pump 3042f152 dpa pump 3042f152-r dpa pump 3042f170 dpa pump 3042f171 dpa pump 3042f172 dpa pump 3042f210 dpa pump 3042f212 dpa pump 3042f213 dpa pump 3042f213-r .

Bruce W. Bode, MD, FACE Atlanta Diabetes Associates Atlanta, Georgia American Diabetes Association. Facts and Figures. Available at: http://www.diabetes.org/ada/facts.asp. Accessed January 18, 2000. Diagnosed Type 1 Diabetes 0.5 - 1.0 Million Diagnosed Type 2 Diabetes 10.3 Million Undiagnosed Diabetes 5.4 Million Prevalence of Diabetes in the US 3

9w9310 776c, 776d, 777b, 777d 9t6577 pump g gear 9t6813 pump g 9t7414 pump gr 9t7465 pump g 9t7468 pump g 9t8919 pump gp 9t9839 pump g 9t9909 pump g 9w1723 pump g 9w1724 pump g 9w4704 pump g 9w9310 pump g part no. application 07430-72203 d65a, d65e, d65p, d65s, d75a 07436-72202 d135a, d80a, d80e, d80p, d85a, d85c, d85e, d85p, d95s

a. The Diabetes Centre Calgary for pump assessment. b. An Alberta IPT Program approved diabetes specialist physician. 2. Work with your diabetes team to complete criteria. 3. Meet with a Certified Pump Trainer for a. Pump Prep & Review of Safety b. Pump Start c. Advanced training if required 4.

Start residual heat removal pump (No. 2) and energize motor control center to supply power to-valves. If residual heat removal pump No. 2 did not start, start residual heat removal pump No. 1. Start service water pump No. 4. If service water pump No. 4 did not start, start service water pump No. 5. Start fourth containment ventilation fan.

Diabetes in the United States More than 29 million people in the U.S. have diabetes 8.1 million people with diabetes are undiagnosed 9.3% of the U.S. population 1.7 million Americans aged 20 years or older were newly diagnosed with diabetes in 2010 Every 19 seconds, someone is diagnosed with diabetes

Clinical Diabetes. 2017 Jan; 35(1)51-54. Speight J, Conn J, Dunning T, Skinner TC, Diabetes Australia. Diabetes Australia position statement. A new language for diabetes: improving communications with and about people with diabetes. Diabetes Res Clin Pract 2012 Sep; 97(3): 425- 31.

Type 2 Diabetes Type 2 diabetes, which used to be called adult-onset diabetes, can affect people at any age, even children. However, type 2 diabetes develops most often in middle-aged and older people. People who are overweight and inactive are also more likely to develop type 2 diabetes. Type 2 diabetes usually begins with insulin resistance—a