1 Of 18 DIALux The Basics - Hochiki

3y ago
59 Views
5 Downloads
3.00 MB
18 Pages
Last View : 4d ago
Last Download : 3m ago
Upload by : Nixon Dill
Transcription

1 of 18DIALux The Basics

2 of 18DIALux The BasicsStart the Program by Double Clicking the screen IconClose the Welcome Window by clicking the.Click File,Settings,General Options.

3 of 18DIALux The BasicsThese parameters will be used by DIALuxeach time a new project or room is started.Enter the Length,Width & Height of theRoom.Room Reflectances, Working Plane Heightand Wall Zone.Illumination Level.Click thetab.Enter Your / Company Details.Importing Elumdat & IES FilesClick ‘Luminaire Selection’ along the topMenu Bar.My Database.

4 of 18DIALux The BasicsClick the file Import icon.Navigate to the Photimetric Files location.Click on the File and then Open.Click OK in the Window.Your File is now Imported.

5 of 18DIALux The BasicsClick on the Manufacturer drop down.Select the Manufacturer to show theElumdat Files Imported from theManufacturer.Select the Desired file to use within ProjectClick Apply

6 of 18DIALux The BasicsDIALux 4.9Start the Program by Double Clicking the screen IconClickNavigate to File where file DIALux Lite file isstored, select andNavigate to File where file DIALux file isstored, select file and click Open.

7 of 18DIALux The BasicsHover the Mouse over the end of theMenu and right Click.Select the menus required.The Menus can be moved around to thedesired position.The View Tool Bar is used to select therequired view of the design.From Left to Right are, 3D Standard View,Floor Plan, Side View and Front View.

8 of 18DIALux The BasicsAlternatively all menus can be accessed byclicking on the tabs at the top of theWindow.

9 of 18DIALux The BasicsNew ProjectFill in the length, width &height of the room.Click OKThe room can be edited later.

10 of 18DIALux The BasicsEmergency Lighting CalculationsRight Click on Room1 (or the room youwish to add an emergency scheme to.Follow the menu to Insert Light Scene andLeft Click.Rename as ‘Emergency Lighting’.

11 of 18DIALux The BasicsTick the box for Emergency LightingRight Click on Emergency LightingLight Scene.Run across Insert Control Group,select New Control Group.Expand the Control Group Folder.Rename the Control Group to EmergencyLighting

12 of 18DIALux The BasicsSelect your Emergency LuminaireSelect New Field Arrangement ButtonCheck the Average Illuminance Levelrequired, and the number of Luminairesper row.Select Insert

13 of 18DIALux The BasicsSelect the Luminaire GroupUse the arrows at the top to Scroll (right),to show the Emergency Lighting Tab.Tick the box, Use For Emergency Lightingand Only for Emergency Lighting.To Calculate the Light Levels.Select Output, Start CalculationOr Select the Calculator Icon from themenu BarSelect the output Tab.Open the Project Tree to show the LightScene Control Group Surfaces and Doubleclick The Floor Isolines.

14 of 18DIALux The BasicsSelect Print Preview to Display the pagesto print.These are selected on the previous step byticking or un-ticking the box.The report can be printed or converted toPDF depending on your requirement.Importing Drawing files DWGStart DIALux and select New Project.Click OK on the Room Editor.Left click on File, pass your mouse over,Import & then select DWG or DXF file.

15 of 18DIALux The BasicsClick Next in the CAD Import Window.Browse to the location of the file you wishto import.Select the file you wish to Import and clickOpen.

16 of 18DIALux The BasicsOnce the Import Status bar is totally green,click Next.Select the units of the drawing.Click NextFollow through the following windows untilthe drawing importsClick Edit, Edit Room Geometry.

17 of 18DIALux The BasicsLeft Click, hold and drag the corners of theroom to the Corners of the room on thedrawing.Adjust the room Height if required.Select New Room.Click and drag the corners of the NewRoom to the desired room on the DWG.To insert extra points, Right Click on theanywhere on the line where the Extra pointis required.Click and drag the new point to the desiredlocation on the DWG.Once all the points have been added, clickok on the Room Editor.

18 of 18DIALux The Basics

DIALux The Basics DIALux 4.9 Start the Program by Double Clicking the screen Icon . 11 of 18 DIALux The Basics Right Click on Emergency Lighting Light Scene. . PDF depending on your requirement. 15 of 18 DIALux The Basics Click Next in the CAD Import Window.

Related Documents:

May 02, 2018 · D. Program Evaluation ͟The organization has provided a description of the framework for how each program will be evaluated. The framework should include all the elements below: ͟The evaluation methods are cost-effective for the organization ͟Quantitative and qualitative data is being collected (at Basics tier, data collection must have begun)

Silat is a combative art of self-defense and survival rooted from Matay archipelago. It was traced at thé early of Langkasuka Kingdom (2nd century CE) till thé reign of Melaka (Malaysia) Sultanate era (13th century). Silat has now evolved to become part of social culture and tradition with thé appearance of a fine physical and spiritual .

On an exceptional basis, Member States may request UNESCO to provide thé candidates with access to thé platform so they can complète thé form by themselves. Thèse requests must be addressed to esd rize unesco. or by 15 A ril 2021 UNESCO will provide thé nomineewith accessto thé platform via their émail address.

̶The leading indicator of employee engagement is based on the quality of the relationship between employee and supervisor Empower your managers! ̶Help them understand the impact on the organization ̶Share important changes, plan options, tasks, and deadlines ̶Provide key messages and talking points ̶Prepare them to answer employee questions

Dr. Sunita Bharatwal** Dr. Pawan Garga*** Abstract Customer satisfaction is derived from thè functionalities and values, a product or Service can provide. The current study aims to segregate thè dimensions of ordine Service quality and gather insights on its impact on web shopping. The trends of purchases have

SS2013 – based on Dialux V.4.11.0.0. SS2014 – based on Dialux 4.12.0.0. This is a draft document. No unauthorized reproduction or publication is allowed. Aim of this Tutorial:

MANUAL EN DIALux PARA ILUMINACION GENERAL . Figura 11. Selecci on de material y color para paredes y piso. . Figura 18. Generaci on del PDF. 1Manual en DIALux para iluminaci on general realizado por Juliana G alvez Ram rez y Yara Luc a Arango Mar n. 13. 17. Al terminar de generar el PDF, aparece una ventana donde solicita la ubicaci on .

ANSI A300 Purpose: To provide performance standards for developing written specifications for tree management. Currently nine individual parts . ANSI Z60 American Nurseryman and Landscape Association began developing this standard back in 1929 Became an ANSI document in 1949 Current version is 2004 . ANSI A300 The Tree Care Industry Association convened a consensus body .