Fluke 1730Three-Phase ElectricalEnergy LoggerTechnical DataEnergy logging is now within your reach—discover where you’re wasting energy, optimizeyour facility’s energy use and reduce your bill.The new Fluke 1730 Three-Phase Electrical Energy loggerintroduces a new simplicity to discovering sources ofelectrical energy waste. Discover when and whereenergy in your facility is being consumed; from theservice entrance to individual circuits. Profiling energyusage across your facility helps you identify opportunitiesfor energy savings, and provides you with the data youneed to act on them. The new Energy Analyze softwarepackage allows you to compare multiple data points overtime to build a complete picture of energy usage, whichis the first step to reduce the cost of your energy bill. Key measurements: voltage, current, power,power factor and associated values enableenergy saving strategies to be implemented. Bright, color touch screen: perform convenient in-the-field analysis and data checkswith full graphical display. Comprehensive logging: all measured valuesare automatically logged and can be reviewedduring logging and before downloading for onthe-go analysis. More than 20 separate loggingsessions can be stored on the instrument. Optimized user interface: quick, guided,graphical setup ensures you’re capturing theright data every time, and the intelligent verification function indicates correct connectionshave been made, reducing user uncertainty. Complete ‘in-the-field’ setup through thefront panel: no need to return to the workshopfor download and setup or to take a computerto the electrical panel. Wide range power: power instrument directlyfrom the measured circuit eliminating theneed to find a power outlet while allowing theinstrument to be secured safely inside electrical panels. Two USB ports: one for PC connection andanother for fast, simple download to standardUSB thumb drives, or other USB devices. Compact size: designed to fit in tight spacesand panels. Highest safety rating in the industry: 600 VCAT IV/1000 V CAT III rated for use at the service entrance and downstream. Optimized measurement accessories: flatvoltage cable and thin flexible current probesensure easy installation even in tight spaces. Battery life: four-hour operating time (backuptime) per charge on lithium-ion battery. Security: safeguard against theft with aKensington lock. All new, Energy Analyze application software: download, analyze and automatedreporting for a complete picture of energysaving potential.

ApplicationsPower and energy loggingWhen a piece of equipment is operated it instantaneously consumes a specific amount of power inwatts (W) or kilowatts (kW). This power is accuDiscover how much energy individual pieces ofmulated over the operating time and expressed asequipment are consuming when they are operatenergy consumed in kilowatt hours (kWh). Energying at minimum and maximum capacity. Checkis what your electric utility charges for; there willcapacity of circuits prior to adding additionalbe a standard charge from the utility per kilowattloads (various standards exist for this process;hour. Utilities may have other additional charges,in the US the NEC 220-87 is the recommendedstandard). Load studies can also identify situations such as peak demand, which is the maximumpower demand over a defined period of time,where you may be exceeding the allowable loadoften 15 or 30 minutes. There may also be poweron the circuit or when an agreed peak demandfactor charges, which are based on the effects ofapplies from the utility. For convenience, someload studies simply measure current which makes the inductive or capacitive loads in the facility.installation of the measuring equipment quick and Optimizing peak demand and power factor oftenresults in lower monthly electricity bills. Theeasy. It is often recommended that load surveys1730 Three Phase Electrical Energy logger hasbe performed for 30 days so that all typical loadthe capability to measure and characterize theseconditions are encountered during the test.effects enabling you to analyze the results andsave money.Energy surveysUsers often ask where measurements should beSimplified load studiestaken for an energy survey. The answer is mulFor situations where it’s either difficult or impractiple points within the facility. Start at the maintical to make a voltage connection the simple loadservice feeders; compare the power and energystudy feature allows users to perform a simplifiedmeasured here with the readings from the utilload study by measuring current only. The userity meter to ensure you’re receiving the correctcan enter the nominal expected voltage to createcharges. Then move downstream to the largerloads; these should be easy to identify by the cur- a simulated power study. For accurate powerrent rating of the electrical panels downstream of and energy studies it is required to monitor bothvoltage and current but this simplified method isthe service entrances. Measuring at many pointsuseful in certain circumstances.will allow a full picture of energy usage acrossthe facility to be developed. The next question users typically have is how long an energysurvey should last. This of course depends on thefacility, but it is recommended that you measurefor a period that matches a typical facility activity period. If the facility operates over a five daywork week with down time on the weekend, aseven day survey will most likely capture typicalconditions. If the facility operates at a constantlevel for 24 hours a day, 365 days a year, a singleday could be reasonably representative as long asyou avoid a period where there may be plannedmaintenance.To capture a full picture of the facilities energyusage it is not necessarily required to havemeasurements made simultaneously at everyconsumption point in the facility. To get a comprehensive picture, spot measurements can be madeand then compared on a sliding time timescale.For example, you could compare the serviceentrance results from a typical Tuesday between6:00 am and 12:00 pm with those of a larger loadin the facility. Typically there will be some correlation between these profiles.Load studies2 Fluke CorporationFluke 1730 Three-Phase Electrical Energy Logger

Current:Direct inputiFlex3000-24iFlex6000-36i40s-EL clampFrequencyAux inputVoltage Min/MaxCurrent Min/MaxCosϕ/DPFPower factorTHD on voltageTHD on currentRangeResolution1000 V150 A1500 A300 A3000 A600 A6000 A4A40 A42.5 Hz to 69 Hz 10 V dc1000 Vdefined byaccessory0 Cosϕ 10 PF 11000 %1000 %0.1 V0.1 A1A1A10 A1A10 A1 mA10 mA0.01 Hz0.1 mV0.1 Vdefined byaccessory0.010.010.1 %0.1 %Intrinsic Accuracy at Reference Conditions(% of Reading % of Full Scale) (0.2 % 0.01 %) (1 % 0.02 %) (1 % 0.02 %) (1 % 0.02 %) (1 % 0.02 %) (1.5 % 0.03 %) (1.5 % 0.03 %) (0.7 % 0.02 %) (0.7 % 0.02 %) (0.1 %) (0.2 % 0.02 %) (1 % 0.1 %) (5 % 0.2 %) 0.0250.025(2.5 % 0.05 %)(2.5 % 0.05 %)Intrinsic uncertainty (% of reading % of uantity150A/1500A300A/3000AActive power PPF 0.991.2 % 1.2 % 0.005 %0.0075 %0.5 PF 0.991.2 % 7 x1.2 % 7 x(1-PF)(1-PF) 0.005 % 0.0075 %Apparent power S, S fund.0 PF 11.2 % 1.2 % 0.005 %0.0075 %Reactive power N, Q fund.0 PF 12.5 % of measured apparent powerAdditional uncertainty in %U 250 V0.015 %0.0225 %of range11iFlex6000-36600/6000A1.7 % 0.0075 %1.7 % 7 x(1-PF) 0.0075 %1.7 % 0.0075 %i40s-EL4A/40A1.2 % 0.005 %1.2 % 10 x(1-PF) 0.005 %1.2 % 0.005%0.0225 %0.015 %Range 1000 V x IrangeReference conditions:Environmental: 23 C 5 C, instrument operating for at least 30 minutes, no external electrical/magnetic field, RH 65 %Input conditions: Cosϕ/PF 1, Sinusoidal signal f 50 Hz/60 Hz, power supply 120 V/230 V 10 %.Current and power specifications: Input voltage 1 ph: 120 V/230 V or 3 ph wye/delta: 230 V/400 VInput current: I 10 % of IrangePrimary conductor of clamps or Rogowski coil in center positionTemperature coefficient: Add 0.1 x specified accuracy for each degree C above 28 C or below 18 C3 Fluke CorporationFluke 1730 Three-Phase Electrical Energy Logger

Electrical specificationsPower supplyVoltage rangePower consumptionEfficiencyMaximum no-load consumptionMains power frequencyBatteryOn-battery runtimeCharging timeData acquisitionResolutionSampling frequencyInput signal frequencyCircuit typesTHDAveraging periodDemand intervalData storageMemory sizeLogging period100 V to 500 V using safety plug input when powering from the measurementcircuit100 V to 240 V using standard power cord (IEC 60320 C7)Maximum 50 VA (max. 15 VA when powered using IEC 60320 input) 68.2 % (in accordance with energy efficiency regulations) 0.3 W only when powered using IEC 60320 input50/60 Hz 15 %Li-ion 3.7 V, 9.25 Wh, customer-replaceableFour hours in standard operating mode, up to 5.5 hours in power saving mode 6 hours16-bit synchronous sampling5120 Hz50/60 Hz (42.5 to 69 Hz)1-ϕ, 1-ϕ IT, Split phase, 3-ϕ delta, 3-ϕ wye, 3-ϕ wye IT, 3-ϕ wye balanced, 3-ϕAron/Blondel (2-element delta), 3-ϕ delta open leg, Currents only (load studies)THD for voltage and current is calculated using 25 harmonicsUser selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 minUser selectable: 5 min, 10 min, 15 min, 20 min, 30 minInternal flash memory (not user replaceable)Typical 20 logging sessions of 10 weeks with 10-minute intervals1Averaging period1 second5 seconds10 seconds30 seconds1 minute5 minutes10 minutes15 minutes30 minutesInterfacesUSB-AUSB-miniExtension portVoltage inputsNumber of inputsMaximum input voltageInput impedanceBandwidth (-3 dB)ScalingMeasurement categoryCurrent inputsNumber of inputsInput voltageRogowski coil inputRangeBandwidth (-3 dB)ScalingRecommendedfor 20 sessions3 hours15 hours28 hours3.5 days7 days5 weeks10 weeks3.5 months7 monthsFile transfer via USB flash drive, firmware updatesMax. current: 120 mAData download device to PCAccessories4 (3 phases and neutral)1000 Vrms, CF 1.710 MΩ2.5 kHz1:1, 10:1, 100:1, 1000:1 and variable1000 V CAT III/600 V CAT IV3, mode selected automatically for attached sensorClamp input: 500 mVrms/50 mVrms; CF 2.8150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominalprobe range1 A to 150 A/10 A to 1500 A with thin iFlex flexible current probe, 12 inches3 A to 300 A/30 A to 3000 A with thin Flex flexible current probe, 24 inches6 A to 600 A/60 A to 6000 A with thin iFlex flexible current probe, 36 inches40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL1.5 kHz1:1 and variable1The number of possible logging sessions and logging period depends on user requirements.4 Fluke CorporationLogging Periodfor 1 session2.5 days12 days24 days10 weeks20 weeks2 years 2 years 2 years 2 years1Fluke 1730 Three-Phase Electrical Energy Logger

Auxiliary inputsNumber of inputsInput rangeScale factor (available 2014)Displayed units (available 2014)Environmental specificationsOperating temperatureStorage temperatureOperating humidityOperating altitudeStorage altitudeEnclosureVibrationSafetyEMI, RFI, EMCElectromagnetic compatibilityRadio frequency emissionsTemperature coefficientGeneral specificationsColor LCD displayWarrantyDimensionsWeightExternal protection5 Fluke Corporation20 to 10 V dc, 1 reading/sFormat: kx d user configurableUser configurable (7 characters, for example, C, psi, or m/s)-10 C to 50 C (14 F to 122 F)-20 C to 60 C ( 4 F to 140 F)10 C to 30 C (50 F to 86 F) max. 95 % RH30 C to 40 C (86 F to 104 F) max. 75 % RH40 C to 50 C (104 F to 122 F) max. 45 % RH2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV)12,000 mIP50 in accordance with EN60529MIL 28800E, Type 3, Class III, Style BIEC 61010-1: Overvoltage CAT IV, Measurement 1000 V CAT III/600 V CAT IV,Pollution Degree 2EN 61326-1: IndustrialApplies to use in Korea only. Class A Equipment (Industrial Broadcasting andCommunication Equipment)IEC CISPR 11: Group 1, Class A0.1 x accuracy specification/ C4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch panel1730 and power supply: Two-years (battery not included)Accessories: One-yearCalibration cycle: Two-years1730: 19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in)Power supply: 13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in)1730 with power supply attached: 19.8 cm x 16.7 cm x 9 cm(7.8 in x 6.6 in x 3.5 in)1730: 1.1 kg (2.5 lb)Power supply: 400 g (0.9 lb)Holster, Kensington lock slotFluke 1730 Three-Phase Electrical Energy Logger

1500-12 iFlex Flexible Current Probe specificationsMeasuring rangeNondestructive currentIntrinsic error at reference condition*Accuracy 1730 iFlexTemperature coefficient over operating temperature rangeWorking voltageProbe cable lengthProbe cable diameterMinimum bending radiusOutput cable lengthWeightTransducer cable materialCoupling materialOutput cableOperating temperatureTemperature, non-operatingRelative humidity, operatingIP ratingWarranty1 to 150 A ac / 10 to 1500 A ac100 kA (50/60 Hz) 0.7 % of reading (1 % of reading 0.02 % of range)0.05 % of reading/ C 0.09 % of reading/ F1000 V CAT III, 600 V CAT IV305 mm (12 in)7.5 mm (0.3 in)38 mm (1.5 in)2 m (6.6 ft)115 gTPRPOM ABS/PCTPR/PVC-20 C to 70 C (-4 F to 158 F) temperature of conductorunder test shall not exceed 80 C (176 F)-40 C to 80 C (-40 F to 176 F)15 % to 85 % non-condensingIEC 60529:IP50One-year*Reference condition: Environmental: 23 C 5 C, no external electrical/magnetic field, RH 65 % Primary conductor in center positionOrdering information1730/BASIC Three-Phase Electrical Energy logger (excludes current probes).1730/US Portable Energy Logger US version1730/EU Portable Energy Logger EU version1730/INTL Portable Energy Logger INTL versionAccessoriesi1730-flex1500 iFlex flexible current probe 1500A 12 inchi1730-flex3000 iFlex flexible current probe 3000A 24 inchi1730-flex6000 iFlex flexible current probe 6000A 36 inchi40s-EL i40s-EL Clamp-on Current Transformeri1730-flex1500/3pk iFlex flexible current probe 1500A 12 inch, 3 packi1730-flex3000/3pk iFlex flexible current probe 3000A 24 inch, 3 packi1730-flex6000/3pk iFlex flexible current probe 6000A 36 inch, 3 packi40s-EL/3pk i40s-EL Clamp-on Current Transformer, 3 pack1730-TL0.1M Test Lead Set; 1000 V CAT III, straight plug; 0.1 m; silicone; red/black1730-TL2M Test Lead Set, 1000 V CAT III; straight plug; 2 m; PVC red/black3PHVL-1730 Cable Assembly, Voltage Test Lead 3-Phase NC1730 1730 Soft CaseWC100 Color Localization Set1730-Hanger Hanging strap1730-Cable AUX input cableFluke. The Most Trusted Toolsin the World.Fluke CorporationPO Box 9090, Everett, WA 98206 U.S.A.Fluke Europe B.V.PO Box 1186, 5602 BDEindhoven, The NetherlandsFor more information call:In the U.S.A. (800) 443-5853 orFax (425) 446-5116In Europe/M-East/Africa 31 (0) 40 2675 200 orFax 31 (0) 40 2675 222In Canada (800)-36-FLUKE orFax (905) 890-6866From other countries 1 (425) 446-5500 orFax 1 (425) 446-5116Web access: http://www.fluke.com 2013 Fluke Corporation.Specifications subject to change without notice.Printed in U.S.A. 8/2013 4314073B ENPub ID: 12028-eng Rev. 01Modification of this document is not permittedwithout written permission from Fluke Corporation.6 Fluke CorporationFluke 1730 Three-Phase Electrical Energy Logger

Fluke 1730 Three-Phase Electrical Energy Logger The new Fluke 1730 Three-Phase Electrical Energy logger introduces a new simplicity to discovering sources of electrical energy waste. Discover when and where . in th

Related Documents:

FLUKE 86 367 FLUKE 88 423 FLUKE 8062A . FLUKE 8060A . FLUKE 8010A . FLUKE 8012A . FLUKE 8050A . FLUKE 37 FLUKE 45 E SCOPES 329 395 329 359 439 249 579 20 MHz SCOPE 345 Dual Trace 2 Yr Warranty-Parts & Labor SCOPE PROBES 60 MHz, X1 & X10 SPECIAL 700072 18.95 150 MHz, X10 700073 39." Duracell / Eveready 9V Alkaline Battery .

1228556 fluke 1663 / fvf au installation tester fluke 1365408 fluke 64 max ir thermometer 20:1 d:s fluke 1758013 fluke high resolution diagnostic videosc fluke 1758015 8.5mm scope with a 3m probe, dual view c fluke 2524570 c12a soft carrying case fluke 2921230 t5-100

3 Phase Power Quality Analyzer Fluke 1730 3 Phase Electrical Energy Logger Fluke 1735 3 Phase Power Logger with 3000 A Flexi-CTs Fluke 1750 3 Phase Power Quality Recorder . . VIBRATION TESTERS Fluke 805 Portable Vibration Meter Pen Fluke 810 Portable Vibration Tester . Juneau Manitoba Saska

5 Fluke Corporation Tester per batterie Fluke Serie 500 Fluke Italia S.r.l. Viale Lombardia 218 20861 Brugherio (MB) Tel: (39) 02 3600 2000 Fax: (39) 02 3600 2001 E-mail: fluke.it.cs@fluke.com Web: www.fluke.it Fluke (Switzerland) GmbH Industrial Division Hardstrasse 20 CH-8303 Bassersdorf Telefon: 044 580 75 00 Telefax: 044 580 75 01

FLUKE-117/323 EUR 4296034 Fluke Electrician’s Multimeter Combo Kit 435 FLUKE-117/PRV240 4636971 Prüfeinheit, Fluke 117 DMM Kit 437 Multimeter Serie 170 . FLK-TRUTEST-ADV 5265319 Fluke TruTest Software-Lizenzcode – Erweitert 429 FLK-TRUTEST-CD 5265337 Fluke Tru

FLUKE-289/FVF/EUR 3947812 Combinatiekit van Fluke 289 en FlukeView Forms-software 845 FLUKE-289/IMSK 3449156 Serviceset industriële multimeter 720 20 Series Multimeters C25 681114 Soepele draagtas geschikt voor Fluke 25/27/8025A 66 FLUKE-27II/EUR 3947770 Industriële Multimeter (IP67) 586 FLUKE

See your Fluke distributor, or call 1- 800 -87 -FLUKE for a catalog and the name of the distributor nearest you. in the industry. Make the choice that gives you the most choices. Fluke 12 Auto -function Multimeter S95.00 FLUKE 12 FLUKE 77 FLUKE 83 The Fluke

2 For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards volume information, refer to the standard’s Document Summary page on the ASTM website. 1