Texas Deregulated Utilities - Milbank

2y ago
27 Views
2 Downloads
1.05 MB
6 Pages
Last View : 14d ago
Last Download : 6m ago
Upload by : Aarya Seiber
Transcription

Meter Mounting EquipmentTexas Deregulated UtilitiesTexas/New Mexico Power - TNP & CVEC Area125-320 Amps 4-7 Terminals Single PositionCatalog 25U8100-ZL*200-320 Amps 7 Terminals Single Position Medium & Heavy DutyCatalog XL2005OHU1079-R3204OHU2448-X3204OH/UG*Lever operates bypass only, not jaw clamping.*Includes a 1 /2" hub.†Side wireway included.1150 Amps per Position 4 Terminals Multi-Position Horizontal GangsCatalog 5045OH/UGU1236-RXL15046OH/UGU1980-O200 Amps per Position 4 & 7 Terminals Multi-Position Horizontal GangsCatalog /UGU7423-XLPlease consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval.All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes inspecifications and features shown without notice or obligation.Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO 64120 877.483.5314 milbankworks.comTX 08/20

Meter Mounting EquipmentTexas Deregulated UtilitiesCoServ Area200-320 Amps 4 Terminals Single Position200-320 Amps 7 Terminals Single Position Medium & Heavy DutyCatalog NumberAmpsTerminalsServiceCatalog 2/K6320‡*Lugs er*Includes a 2" hub.†Lever operates bypass only, not jaw clamping.‡Lugs included.Pedernales Electric Cooperative (PEC)200-320 Amps 4 Terminals Single PositionCatalog 3204UGAEP—West AreaU7021-DL-TG200 Amps per Position 4 Terminals Multi-Position Horizontal Gang Lugs IncludedCatalog OH/UG400 Amps 4 & 7 Terminals Meter Mains with Breaker Lugs IncludedCatalog 1-BLG-SLVG*Has a 400 Amps main breaker.†Includes two 200 Amps main breakers.Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval.All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes inspecifications and features shown without notice or obligation.Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO 64120 877.483.5314 milbankworks.comTX 08/20

Meter Mounting EquipmentTexas Deregulated UtilitiesAEP—West Area (cont.)125-200 Amps 4 Terminals Single PositionCatalog -QG-BLG-AEP*2004OH/UG*UAP for coastal area (aluminum).200 Amps 5 & 7 Terminals Single Position Heavy Duty 3ØCatalog G-BLG-AEP*UAP for coastal area (aluminum).320 Amps 4-7 Terminals Single Position Lugs IncludedCatalog Ø4W††U4342-R-K7-K6*UAP for coastal area (aluminum).†Side wireway included.Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval.All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes inspecifications and features shown without notice or obligation.Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO 64120 877.483.5314 milbankworks.comTX 08/20

Meter Mounting EquipmentTexas Deregulated UtilitiesXCEL Energy200-320 Amps 5 & 7 Terminals Single Position Heavy DutyCatalog 1-XL-5T9200 Amps per Position 5 Terminals Multi-Position Horizontal Gangs Heavy DutyCatalog 2876-XT-5T920056OH/UGLeverU2872-XT-5T9CenterPoint Energy*125-200 Amps 4-7 Terminals Single Position Ring TypeCatalog 205OH/UG3207OH/UGU1973-EL*U3328-RXL-LR†*Includes 2 /2" hub and is phase 3Ø3W.†Includes lever bypass that supplies clamping action on meter spades and also operates bypass device.1U8878-O-LR320 Amps 4-7 Terminals Single Position Heavy DutyCatalog Gang sockets are approvedby CenterPoint Energy on acase-by-case basisPlease consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval.All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes inspecifications and features shown without notice or obligation.Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO 64120 877.483.5314 milbankworks.comTX 08/20

Meter Mounting EquipmentTexas Deregulated UtilitiesEntergy125-200 Amps 4-7 Terminals Single PositionCatalog RL-TG2004OHU1980-O2004UG200-320 Amps 4-7 Terminals Single Position Heavy DutyCatalog ‡U7487-RL-TG*Lugs included.†This product has a center disconnect.‡Includes a side wireway.U4419-X200 Amps per Position 4 Terminals Multi-Position Horizontal GangsCatalog 45OH/UGU1256-X20046OH/UG*Lugs included.Current Transformer CabinetsCatalog 403214-TC3R-SP1Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval.All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes inspecifications and features shown without notice or obligation.Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO 64120 877.483.5314 milbankworks.comTX 08/20

Meter Mounting EquipmentTexas Deregulated UtilitiesTXU/Oncor Area150-320 Amps 4-7 Terminals Single PositionCatalog o BypassU7040-XL-TG2004OH/UGNo 701-RXL2007OH/UGHDU4362-R3204OH (w/o lugs)HDU1797-O-K3L-K2L*3204UG (w/ lugs)LeverU4013-X*3207OH/UG (w/o lugs)LeverU1797-O-K3L-K2L*Includes side wireway.150-200 Amps 4 Terminals Multi-Position Horizontal GangCatalog -X2004OH/UGCatalog U9701-RXL200 Amps 4 Terminals Mobile Home PedestalAccessoriesHubs forStandard"RL" r-RRLS8324Lug KitsSuffixCatalog Number350 kcmil1Ø(3 per set)Single-K1K1539Twin-K2K13501 /4"-YLA751511/2"-ZLA7516Twin (non-rotating)-K2LK1350L2"-DLA7517600 kcmil1Ø(3 per set)2 /2"-ELA751811Hubs forStandard "R"OpeningSuffixCatalogNumber3"-FA811013 /2"-G4"-HSingle-K3K1540Single (non-rotating)-K3LK1540LTwin-K4K1541Fifth TerminalsCatalogNumberSquare HoleK5T350 kcmil3Ø(4 per set)5T8K2Single-K5K3082A8111Twin-K6K3442A8112600 kcmil3Ø(4 per set)Single-K7K3441Twin-K8K3083Round HolePlease consult serving utility for their requirements prior to ordering or installing, asspecifications and approvals vary by utility, and may require local electrical inspector approval.All installations must be installed by a licensed electrician and must comply with all nationaland local codes, laws and regulations. Milbank reserves the right to make changes inspecifications and features shown without notice or obligation.Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO 64120 877.483.5314 milbankworks.comTX 08/20

Meter Mounting Equipment Texas Deregulated Utilities U4342-R-K7-K6 U9581-RL-QG-BLG-AEP Catalog Number Amps Terminals Service U7040-RL-TG-KK-BLG-AEP 200 4 OH U7021-RL-TG-KK-BLG 200 4 OH U1980-O-KK-BLG-AEP 200 4 UG UAP7040-RL-TG-KK-BLG-AEP* 200 4 OH UAP1980-O-KK-BLG-AEP* 200 4 UG U9801-R

Related Documents:

Charles A. Milbank 1879-1966 Bill Martin 1916-1998 Robert F. Waldrop 1922-2002 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman Milbank–Quality Metering Products for 80 Years ilbank Manufacturing Company was estab-lished in 1927 by Charles A. Milbank. Ori

Charles A. Milbank 1879-1966 Bill Martin 1916-1998 Robert F. Waldrop 1922-2002 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman Milbank–Quality Metering Products for 80 Years ilbank Manufacturing Company was estab-lished in 1927 by Charles A. Milbank. Originally, the com

GL Garrad Hassan Chris Elkinton chris.elkinton@gl-garradhassan.com China renewable energy policy Milbank, Tweed, Hadley & McCloy Shepard Liu shepard.liu@milbank.com China renewable energy investment Covington & Burling Tim Stratford, Chris Angell, Ellen Eliasoph eeliasoph@cov.com

Introduction About Milbank Key Contacts To discuss our capabilities, please visit our website at www.milbank.com or contact any of the attorneys listed. The following is an excerpt of chapters 6-11 from PEI's publication Understanding High-Yield Bonds: A complete guide for investors, issuers, banks and advisers. Authored by

20 Texas Co-op Power Bryan Texas UTiliTies June 2013 www.btutilities.com William D. Ballard, Jr. joined the Bryan Texas Utilities (BTU) Board of Directors in November 2012 and . The Bryan & College Station Public Library System has brought back a classic summer activity that is part of a Texas State Library outreach to every child in Texas .

Oracle Utilities Work and Asset Management 22 Oracle Utilities Mobile Workforce Management 24 Oracle Utilities Other Sessions (ODM, Opower, Etc.) 26 Oracle Utilities Technical Sessions 28 . 4 2017 ORACLE UTILITIES EDGE CUSTOMER

airline industry in 1978. The Airline Deregulation Act of 1978 deregulated the aviation industry while keeping the Federal Aviation Administration from the CAB era to control aviation safety for all airlines in the United States (Button, 2017; Williams, 1994). When the airline industry was deregulated, private companies had to figure out how to

Literary Studies. London: Longman, 1993. INTRODUCTION While most of you have already had experience of essay writing, it is important to realise that essay writing at University level may be different from the practices you have so far encountered. The aim of this tutorial is to discuss what is required of an English Literature essay at University level, including: 1. information on the .