Liebert PDXfrom 15 to 165 kWDirect Expansion Solution for Smalland Medium Data Centers 91 8806660084www.prasa-pl.comenquiry@prasa-pl.com

LIEBERT PDX from 15 to 165 kWVertiv Vertiv designs, builds and services mission critical technologies that enable the vital applications fordata centers, communication networks, and commercial and industrial environments. We supporttoday's growing mobile and cloud computing markets with our portfolio of power, thermal, infrastructuremanagement products, software and solutions, all complemented by our global service network.Bringing together global reach and local knowledge, and our decades-long heritage including brandslike Chloride , Liebert and NetSure our team of experts is ready to take on your most complexchallenges, creating solutions that keep your systems running—and your business moving. Together,we’re building the future of a world where critical technologies always work.YOUR VISION, OUR PASSION.VertivCo.euThe Liebert PDX direct expansion cooling unit is equipped with the most advancedindustry technology, guaranteeing precise cooling of data centers and server rooms.The Liebert PDXaddition, Liebert PDX also includes unique Digital Scroll technology, making it the ideal, scalable cooling system able to expand withwith a 50 kW unit (inclusive of Digital Scroll) consuming as little as a 10 kW unit, thus delivering advantageous energy savings.2 91 8806660084www.prasa-pl.comenquiry@prasa-pl.com

91 8806660084www.prasa-pl.comenquiry@prasa-pl.com3

LIEBERT PDX from 15 to 165 kWLiebert PDX Key FeaturesR410A RefrigerantEuropean ErP 2015 DirectiveEurovent CertifiedDesigned for R410A Refrigerant.Precision cooling floor mount productscomply with the European ErP 2015Directive requirements, respectingenvironmental commitments whilereducing operating costs.Eurovent certification guarantees thatLiebert PDX undergoes independenttesting, thus delivering rating accuracyand enhancing the unit's reliability.Copeland Digital Scroll TechnologyThe best solution in terms of variablecooling capacity.23 22 21 20 19 18 17 Precise Temperature ControlDigital Scroll based technology allowsfor close monitoring and control of roomtemperature.www.eurovent-certification.comHeat Load Monitoringthrough the combination of marketleading technologies.Continuous monitoring of heat loadensures that only necessary kilowattsare invested in targeted cooling, thusconserving energy.Ultrasonic Humidifier - TheLiebert EC Fan 2.0The new generation of Liebert EC Fan2.0 is the core of the Liebert PDX,significantly minimizing noise levels andTechnologyLiebert PDX's cutting-edge technologyallows each of its components to saveenergy while delivering the required datacenter cooling performance. Theinfrared and electrode boiler humidifierVertiv supports customers with anavailability and total peace of mind 24/7.Electronic Expansion ValveThis valve is designed to constantlyoptimize the refrigeration circuit'sperformance in order to achieve theThe relevant valve managementsoftware is also embedded in the unit'sVertiv ICOM control function.Freecooling Modes for OptimizingFresh Air/Direct FreecoolingWater/Indirect FreecoolingLiebert EconoPhase PumpedRefrigerant Economizer.LiebertEconoPhaseEconomizerVertiv ICOM Control - WhenLiebert MCMicrochannelCondenserSmart mode is a control algorithmdeveloped for Vertiv SmartAisle containment applications, meeting thecooling and airflow needs of the serverswhile ensuring only necessary kilowattsare invested in targeted cooling.4Liebert PDXFloor-MountUnit 91 8806660084The Liebert EconoPhase pumpedrefrigerant economizer is compatiblewith the Liebert PDX and Liebert MCto improve thermal management andcontrol, while drastically cuttingenergy costs and lowering pPUE.www.prasa-pl.comenquiry@prasa-pl.com

Liebert MC: The New Condensing TechnologyLiebert MC new microchannel condensers are ideally designed to match the outstanding performances of Liebert PDX. ICOM Control,providing significant advantages in terms of condenser management. The Liebert MC can thus be managed through the LiebertPDX Vertiv ICOM control allowing the complete coordination of unit and condenser settings status and alarm conditions. Thepossibility of selecting silent functioning modes at defined times (i.e. during the night or the weekend), through the unit control,further ensures full operating flexibility.2000when compared to a standardcondenser adopting the Variable1500levels are further optimized at partialload where the EC Fans require a lowerpower input, thus reducing energyconsumption and guaranteeing top-tierperformances.Power Input/Fan (Watts)Liebert MC microchannel condensers,equipped with EC fans, deliver a 20%VFDEC Fans10005000100%80%60%40%20%0%Fan Speed (%)For specific environments in which microchannel condenser use is limited,Liebert HCR base condensers are available.Microchannel Condensing Coil:New generation EC Fans:The full aluminum coil ensuresThe new generation EC Fans guarantee the highestthe mechanical cooling mode.extremely silent operations.Microchannel Aluminum Coils 91 8806660084www.prasa-pl.comenquiry@prasa-pl.com5

LIEBERT PDX from 15 to 165 kWThe Vertiv ICOM device features aunique control algorithm designed tomanage the operation of the Liebert PDX units, ensuring top reliability in allconditions. Liebert PDX units with theVertiv ICOM control graphic display, maybe centrally monitored and controlledwith the optional wall mounted display.The display allows access to the unit viathe Network, making coordinationbetween Liebert PDX units within thesame room possible as a result of theintegrated Ethernet connection. The selfmonitoring of redundant units alternatesstandby positions and gives priority topossible hot spots. The high-levelsupervision of multiple units allows themto work together as a single systemoptimizing room temperature andhumidity. This is of particular importancefor EC fans. EC fan power consumption6is exponential. Having five units runningat 80% instead of four at 100% will lowerthe total energy used by the entiregroup by 36%. Vertiv ICOM manages thereduction of fan speed wheneveroperation at full capacity is not required.Liebert PDX digital modulates both fansand compressors thus increasing theturn further increased as a result ofLiebert PDX's ability to share the heatload among installed units, guaranteeingideal cooling levels while minimizingconsumption.Unit to Unit CommunicationVertiv ICOM directly connects with thefacility network (Ethernet) and enablescommunication between multiple LiebertPDX units for synchronized operation,guaranteeing increased reliability andprecision cooling room control. 91 8806660084Smart mode is a control algorithmdeveloped for Vertiv SmartAisle containment applications, meetingthe exact cooling and airflowneeds of the servers, investingonly necessary kilowatts intargeted cooling.www.prasa-pl.comenquiry@prasa-pl.com

Liebert PDX: Remote Diagnostic and Preventive Monitoring ServicesVertiv LIFE Services RemoteDiagnostic and Preventive MonitoringProactive equipment maintenancereduces downtime and extendsequipment life which in turn maximizesreturn on investment and increasessystem availability. Vertiv supports entirecritical infrastructures with an extensiveMonitoring and Control ThroughExisting Network Via your WebBrowserThe Liebert PDX system can be fittedwith a Vertiv IntelliSlot Unity Cardallowing full advantage to be taken ofthe Ethernet network and remotemonitoring from your computer desktop,network operations center or anynetwork access simply utilizing astandard web browser. A standard webbrowser, via HTTP protocol or NetworkManagement System software via SNMPprotocol, can be used to access the unitinformation.Monitoring Integration withExisting Building ManagementSystemIf required, Liebert PDX may beintegrated with an existing BuildingManagement System, while the VertivIntelliSlot Unity Card provides ModbusRTU and Modbus TCP compatibility.SCADA support is completed throughthe Bacnet over IP card.Vertiv Nform Software CentralizedManagementAs business grows, critical equipmentinfrastructure expands, thus the need forcentralized management of anyequipment is key to business success.Connecting to equipment in thedistributed critical space is only part ofthe monitoring challenge. Vertiv Nformleverages the network connectivitycapabilities of Liebert PDX to providecentralized monitoring of the distributedequipment. Utilizing the SNMP and Webavailability and total peace of mind 24/7.Our approach to servicing criticalinfrastructure covers all aspects ofavailability and performance, from singleunits to entire mission critical systems,providing customers with tailoredservices to meet their individualbusiness needs. Vertiv’s service programis designed to ensure that your criticalThermal Management system ismaintained in an optimum state ofreadiness at all times. Vertiv LIFEServices enable 24/7 Remote Diagnosticand Preventive Monitoring providingearly warning of Thermal Managementunits conditions and out of tolerances.This allows proactive maintenance andremote trouble shooting minimizing therisk of downtime and optimizing MeanTime Between Failures and First TimeFix Rate, granting total peace of mind.Basic Web AccessBasic operational information can bemade available through the monitoring Control over Ethernet. A web browser isthe only requirement needed for the unitto communicate directly with the local orremote web interface.Vertiv SiteScan WebControl,Data Capture, EnergyManagement and PlanningLI F E S e r viAdvanced Access withVertiv Intellislot Card 91 8806660084For customers who requireextensive management of criticalsystem equipment spanningmultiple locations in an evermoving global enterprise, VertivSiteScan Web will centrallymanage critical equipment andgive the power to move beyondthe event responsive serviceparadigm.Vertiv SiteScan Web does it allReal-Time Monitoring andControlEvent Management andReportingData Analysis and TrendingBuilding ManagementIntegration.Vertiv SiteScan Web is acomprehensive critical systemmanagement solution dedicatedto ensuring reliability throughgraphics, event management anddata export. The standard webinterface allows users easy accessfrom anywhere, anytime.ceVe rtivVertiv SiteScan WebControl, Data Capture,Energy Management andPlanningsBasic Web Accesstechnologies integrated in the IntelliSlotcommunication card, Vertiv Nformcentrally manages alarm notificationsand provides an intuitive interface toaccess critical status information. VertivNform allows critical system informationto be readily available to supportpersonnel wherever they are, increasingresponsiveness to alarm-eventconditions, thus allowing IT organizationsto maximize their system availability.Monitoring andAlarm Notificationthrough Vertiv Nformwww.prasa-pl.comenquiry@prasa-pl.com7

LIEBERT PDX from 15 to 165 kWLiebert PDX - Scroll SpecificationsSINGLE CIRCUITModelTotal Gross Cooling CapacitykWNet Sensible Cooling CapacitykWSHRNet Sensible 9277527944100001090011200145001580016300Max. ESPPa25025025022018025010080300300300Dimensions (W x D)mm844 x890844 x 890844 x 890844 x 890844 x 8901200 x 8901200 x 8901200 x 8901750 x 8901750 x 8901750 x 890Height 2AirflowNumber of Capacity StepsAiflow DeliveryDown Flow UP - Fans Over the Raised FloorUp FlowFrontalDownflow Down - Fans in Raised FloorCooling Version:Air CooledWater CooledDual fluid (Chilled water DX Air Cooled)Dual fluid - Chilled water DX Water CooledFreecoolingEconoPhaseDOUBLE 094PX104PX120Total Gross Cooling .9Net Sensible Cooling 7SHR0.990.990.950.980.900.820.970.960.920.86Net Sensible m3/hMax. ESPPa30020020030080180250150100100Dimensions (W x D)mm1750 x 8901750 x 8901750 x 8902550 x 8901750 x 8901750 x 8902550 x 8902550 x 8902550 x 8902550 x 890Height tkg6386426808876809869019019019542222222224Number of Capacity StepsAiflow DeliveryDown Flow UP - Fans Over the Raised FloorUp FlowFrontalDownflow Down - Fans in Raised FloorCooling Version:Air CooledWater CooledDual fluid (Chilled water DX Air Cooled)Dual fluid - Chilled water DX Water CooledFreecoolingEconoPhasePerformances at 24 C 50% - 45 C condensing temperature - Nominal ESP 20 Pa8 91 8806660084www.prasa-pl.comenquiry@prasa-pl.com

Liebert PDX - Digital Scroll - Vertiv SmartAisle SINGLE CIRCUITModelTotal Gross Cooling CapacitykWNet Sensible Cooling CapacitykWSHRNet Sensible EERAirflowMax. ions (W x D)mm844 x890844 x 890845 x 890844 x 8901200 x 8901200 x 8901200 x 8901750 x 8901750 x 8901750 x 890Height %25%25%25%25%Minimum Nominal Capacity ModulationAiflow DeliveryDown Flow UP - Fans Over the Raised FloorUp FlowFrontalDownflow Down - Fans in Raised FloorCooling Version:Air CooledWater CooledDual fluid (Chilled water DX Air Cooled)Dual fluid - Chilled water DX Water CooledFreecoolingEconoPhaseDOUBLE 094PX104PX120PX150PX165Total Gross Cooling 153.4199.1228.1Net Sensible Cooling 01.001.001.00SHRNet Sensible EERAirflowm3/hMax. ESPPaDimensions (W x D)mmHeight (H)mmWeightkgMinimum Nominal Capacity 1601750 x 890 1750 x 890 1750 x 890 2550 x 890 1750 x 890 1750 x 890 2550 x 890 2550 x 890 2550 x 890 2550 x 890 3350 x 890 3350 x %10%10%12.5%12.5%12.5%12.5%12.5%12.5%Aiflow DeliveryDown Flow UP - Fans Over the Raised FloorUp FlowFrontalDownflow Down - Fans in Raised FloorCooling Version:Air CooledWater CooledDual fluid (Chilled water DX Air Cooled)Dual fluid - Chilled water DX Water CooledFreecoolingEconoPhasePerformances at 37 C 24% - 45 C condensing temperature - Nominal ESP 20 Pa - Fan over the floor 91 8806660084www.prasa-pl.comenquiry@prasa-pl.com9

LIEBERT PDX from 15 to 165 kWThermal Management Data Center Infrastructure for Small and Large ApplicationsLiebert HPCfrom 40 kW to 1600 kWDesigned specifically for data center applicationsand to work with Vertiv SmartAisle Unique control capabilities with the VertivICOM Control.Liebert PDXLiebert PCWAvailable from 5-220 kWPremium energyEurovent certifiedperformanceUnique controlcapabilities with theVertiv ICOM ControlLiebert EconoPhase available for the directexpansion system.Vertiv Trellis PlatformLiebert EFCIndirect evaporative freecooling unit leveraging on datacenter know-how. Available from 100 to 450 kWUnique control capabilities optimizing water andenergy costsSubstantial reductions and savings in terms ofelectrical infrastructure.10Vertiv’s Trellis TM platform is a real-time infrastructure optimization platform that enables theunified management of data centre IT and facilities infrastructure. The Vertiv Trellis platformsoftware can manage capacity, track inventory, plan changes, visualize configurations, analyzeand calculate energy usage, and optimize cooling and power equipment. The Vertiv Trellisplatform monitors the data center, providing a thorough understanding of system dependenciesto help IT and facilities organizations keep the data center running at peak performance. Thisunified and complete solution, delivers the power to see the real situation in your data center,make the right decision and take action with confidence. 91 8806660084www.prasa-pl.comenquiry@prasa-pl.com

SERVICESVertiv supports entire criticalinfrastructures with the largestglobal service organization and anLiebert AFCThe Adiabatic Freecooling Chiller availablefrom 500-1450 kWIntegrated adiabatic pad systemHigh freecooling capacity100% compressor back up.Vertiv SmartAisle Aisle containmentProvides highest energyWorks with any LiebertThermal Management unit.enhancing network availability andensuring total peace of mind 24/7.Our approach to servicing criticalinfrastructure covers all aspects ofavailability and performance: fromsingle power and thermalmanagement equipment to entiremission-critical systems.The most comprehensiveinsurance for business protectioncan be obtained with a serviceprogram from Vertiv whichincludes access to Vertiv LIFE Services.VERTIV LIFE SERVICESLiebert CRVfrom 10-60 kW in DX and CW versionsFull airflow and cooling capacity modulation tomatch server load and to save energyBest footprint capacity with the highestflexibility.Liebert DCLClosed loop rack coolingClosed LoopHybrid LoopMultiple combinations for up to 4 serverracksVertiv LIFE Services providesRemote Diagnostics andPreventive Monitoring for UPSand thermal managementequipment.Vertiv LIFE Services deliversincreased uptime and operationalmonitoring of your equipment,expert data analysis and fieldengineering expertise.Through the data transferred fromyour equipment via Vertiv LIFEServices, our Remote experts gainthe real-time insight andinformation needed to quicklyidentify, diagnose, and resolve anyirregularities that may arise inoperation, ultimately takingresponsibility for your criticalassets 24/7.Dual CW coil version for redundancy. 91 8806660084www.prasa-pl.comenquiry@prasa-pl.com11

Prasa Infocom & Power Solutions Pvt. Ltd. 91 ivCo.eu Vertiv Infrastructure Limited, George Curl Way, Southampton, SO18 2RY, VAT Number: GB188146827 2018 Vertiv Co. All rights reserved. Vertiv , the Vertiv logo, Liebert PDX, Liebert EC Fan 2.0, Liebert EconoPhase , Liebert MC, Liebert HPC, Liebert PCW, Liebert AFC, Liebert EFC, Liebert CRV, Liebert XD, Vertiv Trellis , Vertiv Intellislot , Vertiv SiteScan ,Vertiv ICOM , Vertiv SmartAisle , Vertiv Nform and Vertiv LIFE Services are trademarks or registered trademarks of Liebert Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. Whileevery precaution has been taken to ensure accuracy and completeness herein, Liebert Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject tochange without notice.MKA4L0UKPDX Rev. 5-04/2018

Liebert PDX Floor-Mount Unit Liebert MC Microchannel Condenser Liebert EconoPhase Economizer The Liebert EconoPhase pumped refrigerant economizer is compatible with the Liebert PDX and Liebert MC to improve thermal management and control, while drastically cutting energy costs and lowering p

Related Documents:

2016 A Stand of Pine in a Tilled Field: 21 Years at PDX, PDX CONTEMPORARY ART, Portland, OR 2013 Nice to Meet You, Atlanta Contemporary Art Center, Atlanta, GA 2011 oomph, PDX CONTEMPORARY ART, Portland, OR 2007 th Drawing(s): 40 artists/200works- A 25 Anniversary Exhibition, The Art Gym, Marylhurst Unive

6 iCOM Control Drives Liebert PDX to the Highest Effi ciency Levels The iCOM device features a unique control algorithm designed to manage the operation of the Liebert PDX units, ensuring top reliability in all conditions. Liebert PDX units with the iCom control graphic display, ma

stimulated insulin secretion (rho 0.41, P 0.005) in the human islets. Ten CpG sites in the distal . PDX-1 gene expression and glycosylated hemoglobin (HbA1c) levels. Luciferase assays were used to examine whether DNA methylation of the human PDX-1 pro-moter and enhancer regions influences its transcriptional

Volume 36, Number 21 July 15, 2019 Publication Pages 483-1092 PLEASE NOTE: This is not the official version of the Oklahoma Administrative Code. . USDOT number required 165:30-10-3. Liability insurance 165:30-10-5. Deleterious Substance Transport Permit 165:30-10-7. Hazardous waste transportation 165:30-10-9. Minimum standards Part 3 .

Liebert PDX andPCW Thermal Management Systems Installer/UserG

Aug 01, 2019 · Liebert EconoPhase pumped refriger-ant economizer) increasing its ability to adapt to diverse application demands. The Liebert EconoPhase pumped refrigerant economizer is compatible with Liebert PDX and Liebert MC to improve thermal management and control,

Liebert PDX Unit Model: PX011 Qty: 1 Liebert MC Condenser Model: MCS028E Qty: 1 Electrical Supply Requirements Evaporator Unit Module: 460 Volt, 3 Phase, 60 Hertz, 10.4 Full Load Amps, 20 Amps Overcurrent Protection Device Condensing Unit Module: 460 Volt, 3 Phase, 60 Hertz,

Ann Sutherland Harris, Professor of Italian Baroque Art Henry Clay Frick Department of the History of Art and Architecture . I am profoundly grateful to my doctoral committee (Ann Sutherland Harris, David Wilkins, Anne Weis, Kathleen Christian, Francesca Savoia and Dennis Looney) for having faith in me, for offering direction when needed, and for their ample doses of .