501170 Thermo7/3/073:41 PMPage 2Thermo Scientific Forma Series IIWater Jacketed CO2 IncubatorsProven water jackettechnologyPart of Thermo Fisher Scientific

501170 Thermo7/3/073:41 PMPage 3Thermo Scientific Forma Series II Water Jacketed CO2 Incubators –# 1 Selling incubators worldwideThermo Scientific Forma Series II WaterJacketed CO2 Incubators combine preciseCO2 control with a choice of TC or IR sensors,unsurpassed temperature stability, andsuperior parameter recovery characteristics,with innovative continuous contaminationcontrol technology. No wonder they are thefirst choice of researchers in academic,clinical, biotech and R&D labs around theworld! Security of Proven Water Jacket Technology– maximum thermal stability and quickrecovery are assured with our unique triplewall construction, providing superiorprotection against temperature loss in theevent of an unexpected power outage. Total Contamination Control minimizes therisk of airborne contaminants entering theincubator upon door openings, with avalidatable in-chamber HEPA air filtrationsystem, maintaining your cultures incleanroom-like Class 100 air qualityconditions. Adaptable to Your Specific Requirementsconfigure the roomy 6.5 cu.ft capacitySeries II, to your specific needs and workenvironment, with a choice of CO2 sensors,reversible door swings and a host ofoptions including available oxygen control,relative humidity monitoring, antimicrobialcopper interiors, datalogging and IQ/OQdocumentation kits.2The Series II Water Jacketed Incubators arereadily stackable to preserve floor space(hardware included as standard)U.S. Patents 5,792,427 and 6,117,687; U.S. Patent Des. 387,164*Third party tested/independently verified. Test results and testing protocol are availableupon request.

501170 Thermo7/3/073:41 PMPage 4Complete Contamination Control –Minimized Risk of Product Loss and DowntimeDesigned for Easy Cleaning Polished stainless steel interiorwith 100% coved corners is easyto clean, saving time and reducingcontamination risk. Sturdy stainless steel shelves andsupports can be readily removedwithout tools for easy cleaning,autoclaving or adjustment Patented inner door gasket isremovable and cleanable, andadjusts continually to ensure atight seal. Snap fit in-chamber HEPA filtercan be easily removed withouttools, as needed. The Series IImessaging center display informsyou when the HEPA should bereplaced.100 % HEPA filtration for rapidresponse class 100 air quality The patented in-chamber HEPA airfiltration system, continuouslyfilters the entire chamber volumeevery 60 seconds, reducingparticulates to Class 100 cleanroomlevels, to preserve your asepticculturing environment. The HEPA filter entraps particulateair contaminants and preventstheir escape. Airborne contaminantsare the primary source ofcontamination in most cell culturelab settings. Efficiency and longterm effectiveness of the HEPAfilter Airflow System protect yourcultures and minimize downtime. Optimized air flow system designwill not interfere with samples orincubator function. Class 100 air quality conditionsare achieved within 5 minutesfollowing a routine door opening. Volatile Organic Compounds(VOC) filtration systemAn optional built-in VOC filtrationsystem removes volatile organicvapors which could pose risk tosensitive cultures. Its molecularsieve technology capturespotentially toxic chemicalscommonly found in products suchas lab solvents, cleaning agentsand plastics, which may find theirway into the incubator. This easily installed, lowmaintenance filtration system ismore effective and longer lastingthan activated charcoal systems inhigh humidity conditions, such asin a CO2 incubator. Examples of chemicals/vaporsfiltered include alcohols (ethanoland methanol), alkanes (decanes,heptanes, hexanes), aromatics(toluene, xylene, benzene, styrene),and olefins (cyclohexane).3Sturdy stainless steel shelves and supports canbe removed without tools for easy cleaning oradjustment100000The patented HEPA Filter Airflow Systemcontinuously filters the entire chamber volumeevery minute to provide an aseptic culturingatmosphereAir ClassificationParticles 0.5 micronAIR QUALITY DEFINEDFederal Standard 209E and InternationalStandard ISO 14644-1 define air qualityclassifications (e.g., Class 1, 10, 100 and ISOClass 1, 2, etc.).100001000The Federal class number is the maximumallowable number of particles 0.5 micronsand larger per cubic foot of air.ISO Class 2 correlates most closely toFederal Standard Class 100.1001010510Time (minutes) after Door Closing152025To find out more about the performance ofour Class 100 HEPA contamination controlsystem, please visit us atwww.thermo.com/incubators

501170 Thermo7/3/073:41 PMPage 5Thermo Scientific Forma Series II WaterJacketed CO2 IncubatorsProven Water Jacket TechnologyTemperature retention and quickrecovery are especially importantfor researchers working with criticalcell cultures. Our water jacketedincubator provides maximumthermal protection and quickrecovery from swings in ambienttemperature and power variations. Durable triple wall cabinetconstruction ensures optimaltemperature uniformity. The SeriesII water jacketed holdstemperature longer and recoversto a uniform interior value morequickly than any other technologyavailable today. Patented, heated dual pane innerglass door minimizes bothersomecondensation with improvedresponsiveness and fastertemperature recovery.Do You Trust Your Power Supply?Power outages can be detrimentalto your cultures. If you aren’tcompletely confident in your powersupply, consider the security of aSeries II Incubator. Product testing during a powerfailure in an 18 C (64.4F) ambientresulted in the water jacketedincubator’s temperature graduallydropping only 1 C – from 37 C to36 C (98.6F to 96.8F) – in 1 hourand approximately 7.6 C in 10hours. The air jacketed incubator’stemperature dropped 3 C – from37 C to 34 C (98.6F to 93.2F) – in1 hour and 17 C in 10 hours.Easy to Configure and UseQuality construction. Reliableperformance. Intuitive controlsshared by other products with theForma name. The Series II Incubatoris designed for long life and ease ofuse.Control O2 Within the CultureEnvironment researchers seeking toexperiment with the effect ofsuppressed oxygen concentrationupon their cultures can select aSeries II model with both CO2 andO2 control capabilities. Individual O2display facilitates set point andmonitoring of desired O2 levels in arange of 0 – 20% for hypoxicstudies.4383736Power Failure Water Jacketed Temperature vs.Air Jacket Temperature with 18 C 62524Temperature ( C)Security of proven water jackettechnology.Should the power go out or the ambienttemperature swing, the Series II’s triple wallconstruction holds the temperature betterthan an air jacket or double wall waterjacket design.2322AirJacketed2120060Time (minutes)120180240300360420480540600

501170 Thermo7/3/073:42 PMPage 6Thermo Scientific Forma Series II WaterJacketed CO2 IncubatorsThermo ScientificEnviro-Scan MicroprocessorMessage CenterRecessed Power SwitchSample PortAccessory OutletAlarm Contacts (NO, NC,COM )Front Fill PortSmooth Front FasciaBlower Wheel/Scroll(directed airflow)CO2 /O2 Sensors (in chamber)Dual Temp Probes(in chamber)Chamber Thru-WallAccess Port with FilterHEPA FilterNon-CFC Foam Insulated OuterDoor (field reversible)Triple-Wall ConstructionWater JacketSturdy Stainless SteelShelvesFiberglass InsulationPolished Stainless Steel Interiorwith 100% Coved CornersRemovable, CleanableGasketStainless SteelHumidity PanMagnetic Outer Door GasketHeated Inner Door with SealedDoor TrimWater Jacket DrainAdjustable FeetNot shown: Inner Door Switch,Ergonomically Designed Inner Door Knob,and Optional Lock for Inner DoorRun – CLASS 100 timing reminder appearsafter door is closed for five minutes, messagechanges to describe alarm conditions5Setpoint – Set Temp,Overtemp, CO2 , O2Calibration – CalibrateTemp, CO2 , O2 , RHProgramming ButtonsAudible/Visual AlarmAlarm SilenceOptional Built-In Gas Guard SystemMode SelectScroll for Program ParametersTemperature DisplaySystem Configuration – Configure Audible On/Off,Access Code, HEPA Filter Change Reminder, RS-485Interface, Automatic Tank Selector, Audible/VisualAlarms, Display Temp/RH (selectable), DisplayCO2 /O2 (selectable)CO2 DisplayGas Inject IndicatorHeater On Indicator

501170 Thermo7/3/073:42 PMPage 7AccessoriesThermo Scientific Forma Series II Water Jacketed CO2 IncubatorsDescriptionCat. No.DAccessories are customer installed unless indicated otherwise. In addition to providing a standard line of equipment and accessories,we will manufacture custom accessories to meet your specific requirements. Contact us for details.RH DisplayHumidity (RH) Display, readable in 1% increments, includes low RH programmable alarm (alerts you of need to add water to humidity pan),factory installedShelving, Ductwork, and Humidity PanStainless Steel Shelf and ChannelsSolid Copper Components –Solid Copper Interior Ductwork (in place of stainless steel components); includes copper interior ductwork, four shelves, and humidity pan;factory installed at time of orderCopper Interior DuctworkCopper Perforated Shelf with ChannelsCopper Humidity Pan (Fig. 01)61906431908841906561900057190879237020Filters* and Decontamination KitReplacement HEPA Filter (Fig. 04)HEPA Value Pack (4 filters)10 Disposable Polypropylene In-Line FiltersHEPA Filter Replacement Kit, includes HEPA, inline, and access port filtersReplacement HEPA2 VOC FilterHEPA2 VOC Filter Replacement Kit, includes HEPA2, in-line and access port filtersHEPA2 VOC Filtration System (kit), converts HEPA Filter Airflow System to HEPA2 Filtration System, includes HEPA2 filter and two silicone plugsDecontamination Kit, includes sample port, HEPA filters, sensor gasket, wheel, and miscellaneous 0199190651Door Kit, Lock, and Right Hand Door SwingIndependent Inner Glass Door Kit (eight glass doors with latches), mounts inside heated inner glass door, is removable and can be autoclaved (Fig. 02)Door Lock for Heated Inner Glass DoorRight Hand Door Swing, factory installed at time of order190650190646190666CO2 and N2 AccessoriesBuilt-In Gas Guards to monitor CO2 or N2, automatically switch from one cylinder to the other when supply is exhausted, factory installed –CO2 Gas GuardN2 Gas GuardRegulators with barbed connection and shut off valve –Two-Stage CO2 Gas Regulator (Fig. 03)Two-Stage N2 Gas RegulatorWall Clamp for a CO2 Bottle, includes cylinder holder with web strapRoller Base and StandRoller Base (heavy-duty steel) with dual-wheel, swivel locking casters and leveling feet; pre-drilled for easy attachment;raises unit 2.8" (7.1cm) off the floor (Fig. 06)Stand (heavy-duty steel) with leveling feet, raises unit 6.5" (16.5cm) off the floorData Outputs (select one), factory installedRS-485 interface4-20 milliamp0-5V analog0-1V analog(continued)*HEPA and HEPA2 filters are rated a minimum 99.97% efficient at 0.3 microns. Filters are easily replaced without 0523190512190543190544

501170 Thermo7/3/073:42 PMPage 8AccessoriesThermo Scientific Forma Series II Water Jacketed CO2 IncubatorsDescriptionCat. No.DMonitoring and Alarm SystemsMonitor/Alarm System, interfaces with as many as 24 products (channels) to monitor and display equipment conditions up to 2,000 ft. awaySensaphone Telephone Dialing Systems, interface with standard touch-tone phone system –For up to four input channelsFor up to eight input channelsDatalogger, -50 C to 140 C (-58F to 284F), meets U.S. FDA guidelines: cGLP 21 CFR Part 58, Software Validation 21 CFR Part 820,and Electronic Records 21 CFR Part 11; evaluation software with cable (No. 201910) is available6", 7 Day Circular Chart Recorders –Single pen, 120VSingle pen, 220VDual pen, 120V, 2 probes, temp/temp (for stacked incubators)Dual pen, 220V, 2 probes, temp/temp (for stacked incubators)Dual pen, 120V, 1 probe, temp/RHDual pen, 220V, 1 probe, 158201159201160Miscellaneous AccessoriesSealed Modular Incubator Chamber, purge with any gas mixture to create a “mini-incubator” inside your incubator for unusual gas and temperature (Fig. 05)controlled experiments, dimensions: 12.0" (30.5cm) circular chamber, 4.7" (11.9cm) highChamber Cooling Coil, use with refrigerated water bath/circulator to operate incubator at lower than ambient temperatures, factory installedReplacement O2 SensorIQ/OQ, MS Windows -compatible document disk for process customization and detailed checklists to qualify unit setup and operation19004319064529008360131107Fig. 03 Two-Stage CO2Gas RegulatorFig. 01 Copper Humidity PanFig. 02 Inner Glass Door KitFig. 04 HEPA Air-Filter (VOC)Fig. 05 Sealed Modular IncubatorChamberFig. 06 Roller Dolly

507120 Thermo:36371 8pg A5/20/084:55 PMPage 1Specifications and order informationThermo Scientific Forma Series II Water Jacketed CO2 formityTracking AlarmTemperature SafetySensorControllerSetabilityCO2/O2CO2/O2 ControlCO2 RangeO2 RangeInlet PressureCO2 SensorO2 SensorReadability & SetabilityTracking AlarmHumidityRHHumidity PanDisplay (opt.)FittingsFill PortDrain PortAccess PortCO2 InletUnit Heat Load115V/230V 0.1 C5 C above ambient to 55 C (131F)* 0.2 C @ 37 C (98.6F)User-programmable high/lowPrecision thermistorIndependent analog electronic0.1 CBetter than 0.1%0-20%1-20%15 PSIG (1.0 bar)T/C or IRFuel cell0.1%User-programmable high/lowAmbient to 95% @ 37 C (98.6F)3.2 qt. (3.0 liters) standardIn 1% increments3/8" hose (barbed)1/4" hose (barbed)1.3" (3.3cm) with removable silicone plug with filter1/4" hose (barbed)ShelvesDimensionsConstructionSurface AreaMax. per ChamberStandard, MaximumConstructionWater Jacket VolumeInterior VolumeInteriorExteriorOuter Door GasketInner Door 3141Circuit Breaker/Power SwitchConvenience ReceptaclePlugAlarm ContactsData Outputs (opt.)DimensionsExteriorInterior344 BTUH (100 Watt)WeightNetNet OperationalShipping (Motor)18.5" x 18.5" (47.0cm x 47.0cm)Stainless steel, perforated2.4 sq. ft. (0.2 sq. m)40.8 sq. ft. (3.8 sq. m)4, 1711.7 gal. (43.5 liters)6.5 cu. ft. (184.1 liters)Type 304, mirror finish, stainless steel18 gauge, cold-rolled steel, powder coatedFour-sided, molded, magnetic vinylRemovable, cleanable, feather-edged, silicone115V, 50/60 Hz, 3.6 FLA (Operating range 90-125V)230V, 50/60 Hz, 2.0 FLA (Operating range 180-250V)6 Amps/2 Pole75 Watts max. (one per chamber)115V: NEMA 5-15P Plug230V: CEE 7/7 PlugPower interruption; deviation of temp, CO2, O2,RH; customer connections through jack on back of unitRS-485, 0-1V, 0-5V, 4-20 milliamp (select one)26.0"W x 39.5"H x 25.0"F-B(66.0cm x 100.3cm x 63.5cm)21.3"W x 26.8"H x 20.0"F-B(54.1cm x 68.1cm x 50.8cm)265 lbs. (120.2 kg)365 lbs. (165.6 kg)324 lbs. (147.0 kg)Orderimg InformationCat. CT/CIRIRChoice of T/C or IR SensorSelect a T/C sensor when chamber temp and RH are relatively constant.Typically, a T/C sensor has a longer life than an IR sensor.Select an IR sensor when temp and RH levels are changed frequently.With either sensor, elevated RH is critical to prevent 230115230115230All units are UL Listed to United States and Canadian requirements and bear the CE Mark.*50 C (122F) on Model 3120 (3121), 45 C (113F) on Models 3130 (3131) and 3140 (3141)CUL 2008 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change.Not all products are available in all countries. Please consult your local sales representative for details.North America: USA/Canada 1 866 984 3766Europe: Austria 43 1 801 40 0, Belgium 32 2 482 30 30, France 33 2 2803 2000,Germany national toll free 08001-536 376, Germany international 49 6184 90 6940,Italy 39 02 02 95059 434-254, Netherlands 31 76 571 4440, Nordic countries 358 9 329 100,Russia/CIS 7 (812) 703 42 15, Spain/Portugal 34 93 223 09 18,Switzerland 41 44 454 12 12, UK/Ireland 44 870 609 9203Asia: China 86 21 6865 4588 or 86 10 8419 3588, India 91 22 6716 2200,Japan 81 45 453 9220, Other Asian countries 852 2885 4613Countries not listed: 49 6184 90 6940 or 33 2 2803 2000BRO-LECO2FWJ-0508www.thermo.com/incubatorsUS

Federal Standard 209E and International Standard ISO 14644-1 define air quality classifications (e.g., Class 1, 10, 100 and ISO Class 1, 2, etc.). The Federal class number is the maximum allowable number of particles 0.5 microns and larger per cubic foot of air. ISO Class 2 correlates mos

Related Documents:

The details for Jacket Pipe and Jacket Bend are given below. Jacket Pipe A Jacketed pipe is input by typing "JP" under Type or selecting "Jacketed pipe" from the Element types dialog. The material, section and load specified in the Jacketed Pipe dialog apply to the jacket pipe, while the corresponding ones mentioned on the layout row .

Water Jacketed Incubator LIWJ-200 Series Application Features Labocon Water Jacketed Incubator LIWJ-200 Series is designed to provide precisely controlled, uniform temperatures and a pure environment for cell culture applications. Labocon Water Jacketed Incubator is ideal for p

less. Third, when a test round's Year 1989 Average 1992 Average b Table 2 10mm Cartridge (Comparison of 1989 and 1992 test results) Ammunition Wounding Average Type Value Expansion (in inches Norma 170 grain 2.63 0.562 Jacketed HP Federal 180 grain 2.08 0.536 Jacketed HP Winchester 180 grain 1.78 0.526 Jacketed HP 2.16 0.541 CCI

Insulated, and Pre-Insulated Tubing Installation Instructions These instructions provide the user with information for the installation of Swagelok single-jacketed tubing, multijacketed tubing, insulated tubing, and pre-insulated trace tubing bundles. For additional information, see the Swagelok Multijacketed Tubing, Jacketed Tubing and

PROFAX NO. DESCRIPTION I.D. O.D. PROFAX NO. DESCRIPTION TF-180 Flexible barrel TFX-180 Flexible barrel for extreme heat PROFAX NO. DESCRIPTION 180-45J Jacketed conductor tube 45 180-60J Jacketed conductor tube 60 180-180J Jacketed conductor tube 180 PROFAX NO. DESCRIPTION 180-45 Conductor tube 45 180-60 Conductor tube 60 180-180 .

PLATECOIL JACKETED PIPE SECTIONS. 36 JACKETED VESSELS . 41 JACKETED TANK BOTTOMS . Details on dimen-sions, configuration and types are presented on pages 5 through 23. . Strict quality control standards govern the fabrication of all PLATE-COIL products to assure structural integrity and durability. Since

the installation of Swagelok single-jacketed tubing, multijacketed tubing, insulated tubing, and pre-insulated trace tubing bundles. For additional information, see the Swagelok Multijacketed Tubing, Jacketed Tubing and Insulated Tubing catalog, MS-02-188 and Swagelok Pre-Insulated Tubing Bundles catalog, MS-02-316. Caution

3.2.2 Vacuum-jacketed piping specifier Individual or organization that has responsibility for defining technical and/or procurement requirements for vacuum-jacketed piping systems. 3.2.3 Getter Reactive material that removes trace contaminants from a gas. 3.2.4 Annular space