o Pharma & Biotech Battery Cells Photovoltaics Flat Panel Display SemiconductorFood & NutritionRETURN AIRSILENT ECO2 LIGHT oCOMPACT oRETURN AIR * ) PIFF * )oooCWIC FFU-Types* ) only turbulent airflow well suited suitedCOMPACTPIFFCWICStandard SizesMotor Types and Control SystemsIndividual dimensionsare available upon requestStandard fan motor ECFeetControl terminal CT31200 mm x 1200 mm4 x 4 Ultra display1200 mm x 900 mm4 x 3 CRiSxt1200 mm x 600 mm4 x 2 Metrico restricted-use– not applicableFilter Fan Unit COMPACT with cooling coil and prefilterMore than half of the products of the world‘s leading wafer fabs are manufactured in environments created by Exyte TechnologyFilter Fan Units with AMC-filter (V-shape)

Filter Fan Units SILENT/ECO2/LIGHTFilter Fan Units RETURN AIR/COMPACTFilter Fan Unit SILENT*FFU-S-EC-1212-T-AUFilter Fan Unit RETURN AIR*FFU-RA-EC-1212-T-AUFFU optimized regarding sound power level and air flow.Particularly suited for: uni-directional airflow (laminar) cleanroom areas advanced requirements on the uniformity of the uni-directional air flow advanced sound pressure level requirements in the room cleanroom classes 1 – 8 according to ISO 14644-1Exclusively suitable for the application in turbulent cleanrooms.Return-flow areas (raised floor, return-air ducts) in the buildingcan be significantly reduced through the integrated return-airducts. Local hot-spots can be avoided by closing of individualintegrated return-air ducts. Particularly suited for turbulent cleanrooms with a maximum of 50% filter coverage cleanroom areas with large scale dimensions cleanroom classes 5 – 8 according to ISO 14644-1Applications- Electronics, Microelectronics- Life Sciences- High Tech Industries- New Technologies- Food Industry- LaboratoriesApplications- Electronics, Microelectronics- High Tech Industries- New TechnologieFilter Fan Unit ECO2*FFU-E-EC-1212-T-AUEffective construction – excellent compromise in terms ofpower consumption, uniformity of the unidirectional air flow,sound power and price. Particularly suited for: non-unidirectional airflow (turbulent) cleanroom areas cleanroom classes 3 – 8 according to ISO 14644-1Applications- Electronics, Microelectronics- Life Sciences- High Tech IndustriesFilter Fan Unit COMPACTFFU-C-EC-1206-T-AUFilter Fan Unit for the equipment of individual workstationsor entire cleanroom ceilings. Especially suited for cleanroom areas with a low installation room clearance cleanroom areas with moderate sound pressure levelrequirements cleanroom classes 1 – 8 according to ISO 14644-1- New Technologies- Food IndustryApplications- Electronics, Microelectronics- Life Sciences- High Tech IndustriesFilter Fan Unit LIGHTFFU-L-EC-1212-T-AUPracticable solution for a low budget.Especially suited for cleanroom areas with high background sound level due to production noises in which sound levels are of secondary importance with a less dense filter coverage cleanroom classes 5 – 8 according to ISO 14644-1Applications- Electronics, Microelectronics- High Tech Industries* These products are protected by patents- New Technologies- Food Industry- New Technologies- Food Industry- Laboratories

PIFF Plenum Integrated Filter Fan/CWIC SystemsCWIC Systems*CWIC – 1010 / 1020 / 1030 / 1040The CWIC System is a versatile system: Individual Filter FanUnits (CWIC modules) can be connected to form different sizecleanroom ceilings, e. g. for machine enclosures, clean benchesor clean work cabins. The modular design enables fast and lowcost cleanroom construction that can be suspended from theceiling or supported from the floor by pedestals. Depending onthe load of additional components, a range of 4.800 mm withoutsupport pedestals or suspensions is possible.PIFF DesignLocal Air Handling Unit (PIFF) Modular concept with low effort for design and installationof the equipment maintenance of function elements from cleanroom side(if there is no possibility for a walkable ceiling with plenum) individual control and monitoring of the every unit byhand terminal or BMS Less pressure drop (1/2 x conventional system) Lower operation costs easy upgrade, increase of the air change rate or cleanroomclass, by installing additional units (e.g. Class D to C) cleanroom classes 1 – 8 according to ISO 14644-1 /class: A, B, C or D according to EC Guide (GMP)Applications- Pharma & Biotech- Food & Nutrition- Science & ResearchFresh airRecirculation airCooling coilPlenum Integrated Filter Fan Units*PIFF 3 - EC-H14Designed as self-sustaining return air unit with integrated FilterFan Unit, H14 filter, cooling coil and air grill. No raised floors andreturn air shafts are needed. Connectable to make-up air orexhaust air in order to pressurize the cleanroom. Especially suitedfor pharmaceutical laboratories with turbulent airflow. cleanroom classes 5 – 8 according to ISO 14644-1 /class B, C and D according EC Guide (GMP)Applications- Pharma & Biotech labs- Food & Nutrition*These products are protected by patentsVentilator unitPrefilter G4HEPA filterExhaust airAir outlet / inlet grillSupply airSupply airReturn air

Customized Filter Fan UnitsControl SystemsApplications (Examples)Control System DC (CSD)Customized FFUApplication: Nanotechnology Stainless steel casingIntegrated five-stage speed controllerModular system in a choice of three standard sizesIntegrated lighting and process air ionization on the air purification sideSlot for AMC filterCE verifiedIn line with SEMI and UL standardsThe control electronics is plug-and-play integrated into theFilter Fan Unit. The individual speed control of each FilterFan Unit allows the adjustment of the air-speed to the localrequirements. Automatic monitoring and fast notificationof any deviations guarantee a safe operation. The network isclearly structured and completely pre-assembled. Dependingon project size, a Control System DC contains the followingcomponents: Control Terminal UltraDisplay CRiSxt – Software with PC-workstationCustomized FFUApplication: Optical Industry Natural aluminum casingSmooth, integrated speed controllerExtremely high reserve capacity with the smallest possible footprintAir purification side laminating unit for optimum flow distributionClient interface to allow total monitoring of the Filter Fan UnitWide-range power supply motors of 110 – 230 V and 50 – 60 HzCE verifiedIn line with SEMI and UL standardsCustomized FFUApplication: Semiconductor Industry Natural aluminum casingSmooth, integrated speed controller featuring LON bus operationSpecial design (L-shape)Integrated lighting and process air ionization on the air purification sideAir purification side laminating unit for optimum flow distributionSlot for AMC filterWide-range power supply motors of 100 – 230 V and 50 – 60 HzCE verifiedIn line with SEMI and UL standardsDC control systems can be operated through a standard interface (LON, Exyte Bus). Auto-installation, an interface to AutoCAD for visualization in actual cleanroom layouts and the abilityto handle up to 75,000 units make CRiSxt an unique softwaresolution for uncompromised FFU administration.Our Filter Fan Units can be operated as a simple power on / offsystem at a pre-configured speed or air volume. Equipmentlayouts, process requirements and work shift models oftenresult in the need for a more sophisticated control of the FFUsystem to ensure energy efficient and process aligned operation.Exyte Technology offers a wide range of control systems forFFUs, starting with budget oriented solutions for small scaleinstallations and ending with the high-end control softwareCRiSxt.

Local SupportWherever You Need UsExyte Technology GmbHRosine-Starz-Str. 2-471272 RenningenGermanyPhone 49 711 8804-8000Email info@exyte-technology.netExyte Technology ShanghaiM W (Shanghai) Co., LtdNo. 139 Beimin Road, Che dunSongjiang Area201611 Shanghai, ChinaPhone 86 21 37838360exyte-technology.net

iso 14644 iso 1 iso 2 iso 3 iso 4 iso 5 iso 6 iso 7 iso 8 fed.std.209 e 1 10 100 1.000 10.0

Related Documents:

7. In front of the mirror, make sure cleanroom garments are tuck in properly. 8. Put on the cleanroom gloves. 9. Step on the sticky mat to remove any contaminants adhering to soles of booties. 10. Enter cleanroom through air shower. B. Degowning procedure (Removing cleanroom garments) 1. Exit from the cleanroom to changing room through air .

Along with safety, particle control is a fundamental part of the cleanroom environment. The cleanroom is a combination of class 100 and class 10,000 cleanroom space. To maintain cleanliness all garments will conform to a class 100 requirements. Particle counter is used for routine cleanliness check throughout the whole area in the cleanroom.

The Cleanroom Design Guidelines describe a number of successful and efficient design practices specifically appropriate for cleanroom facilities. Based on actual measurement of operating cleanroom facilities and input from cleanroom designers, owners and operators, the Cleanroom Design Guidelines offer many successful

tracks. All joints must be sealed with cleanroom compatible neutral grade silicone sealant. All cutouts must be covered with a suitable track. II.1.3. Ceiling: The cleanroom ceiling must be at a height of 2700 mm or higher from the floor of the cleanroom. The ceiling height of the lab space housing the Class-1000 cleanroom is 5250 mm.

calculation. FAN SPEED 0000 RPM Displays fan real time speed based on the fan frequency reading. FAN OUTPUT FREQUENCY 000.0 Hz Displays the output frequency of the fan inverter. FAN OUTPUT CURRENT 000.0 A Displays the output current of the fan inverter. FAN OUTPUT VOLTAGE 000.0 V Displays output voltage of the fan inverter. FAN OUTPUT POWER

TopTherm fan-and-filter unit 6 Rittal – TopTherm fan-and-filter unit Air throughput 550 – 770 m3/h Conversion table old/new Model No. SK fan-and-filter unit 3243.100 3243.110 3244.100 3244.110 3244.140

Cook Medical Bird’s Nest Filter: C. Vena Tech LP FIlter: D. Bard Simon Nitinol Filter: E. Bard Recovery G2 Filter: F. Cook Medical Günther Tulip Filter: G. Cook Celect Filter: H. Cordis OPTEASE Filter: I. Argon Option Elite Filter: J. Crux VCF: K. ALN Optional Filter: Many other IVC f

Filter Gallery dialog box A. Preview B. Filter category C. Thumbnail of selected filter D. Show/Hide filter thumbnails E. Filters pop‑up menu F. Options for selected filter G. List of filter effects to apply or arrange H. Filter effect selected but not applied I. Filter effects applied cumulatively but not selected J. Hidden filter effect Display the Filter Gallery