PULSECO CABLE ASSEMBLIES FOR CONNECTION TO

2y ago
65 Views
3 Downloads
212.62 KB
7 Pages
Last View : 8d ago
Last Download : 3m ago
Upload by : Sutton Moon
Transcription

USB ADC CABLE ASSEMBLIES FOR CONNECTION TO BLOOD PRESSURE MONITORSNOTE: The analogue invasive blood pressure signal from the patient monitor must be the industry standard 1Volt/100mmHg and 0V 0mmHg to be compatible with LiDCO Monitors.Patient monitors that scale differently or have an offset are not compatible with LiDCO Monitors. In this situation the HM 38-01 LiDCO Blood Pressure Module or the HM 38-02 LiDCOCNAP Module might provide a solution.Incompatible monitors are shown in italicsB.P. MonitorManufacturerModel No.ConnectorType on CableAssemblyLiDCO ItemNumber &UDI/GTINLiDCODescriptionDräger (formerlySiemens)Infinity Delta,Infinity Delta XLInfinity Kappa XLT14-way MDRPlug, X10Li1106805060110522286CableAnalogue output must be configured toAssembly, USB ART (not P1): click Pressure parameterADC to Dräger box on display (only displays if apressure transducer is connected), openPressure control menu, select ART.YDrägerInfinity Acute Care System –Infinity M540 (Analog/SyncMcable MS20662 required)14-way MDRPlug, X10Li1106805060110522286CableThe Li11068 must connect to theAssembly, USB M540 through an Analog/Sync McableADC to Dräger MS20662. This MS20662 can eitherplug directly into the Temp/Aux porton the M540, or through a MainStream& Analog/Sync cable MS22259 intothe CO2 port on the M540.YDrawing of the Socket on thePatient MonitorCommentsStockItemAnalogue output must be configured toART (not P1): click Pressure parameterbox on display (only displays if apressure transducer is connected)(it iseasier to do this on the large C500 orC700 display rather than on the smallM540), open Pressure control menu,select ART.DrägerZeus14-way MDRPlug, X10Li1106805060110522286CableRemoving one of the side panels fromAssembly, USB this anaesthesia machine will reveal aADC to Dräger Dräger Delta XL patient monitor,which has the X10 analogue outputsocket. Analogue output must beconfigured to ART (not P1): clickPressure parameter box on display(only displays if a pressure transduceris connected), open Pressure controlmenu, select ART.YFile: USB ADC Cable Assemblies for connection to Patient Monitors 01Feb18.docPage 1 of 7Printed: 16:27 01/02/18

B.P. MonitorManufacturerModel No.ConnectorType on CableAssemblyLiDCO ItemNumber &UDI/GTINLiDCODescriptionFukuda DenshiDS7000 with HU71 module3.5mm StereoJack PlugLi1106305060110522231CableAssembly, USBADC to Philips#C01 BPModuleFukuda DenshiDS7100 with IBP optionDS7200DS7300¼” Jack PlugLi1106305060110522231CableAssembly, USBADC to Philips#C01 BPModuleFukuda DenshiDS85006-way specialPlugLi1113905060110522545CableAssembly, USBADC toDukuda DenshiDS8500Drawing of the Socket on thePatient MonitorCommentsStockItemYBP1 must be set to ART (default) notCVP.There are 2 transducer sockets on thefront of the monitor and the left handone must be used.YNGEDatex Datex / GE patient monitors can be configured in several different ways. From the model number alone one can not foretell with certainty which type of connector will be presentNOTE:for the analogue IBP signal. The only certain method is to look for the Defib/Sync connector and match it to a drawing below.GE DatexAS/3 & 5 Anesthesia MonitorsCS/3 & 5 Critical CareMonitors, Cardiocap/54-way LEMOPlugLi1106505060110522255CableAssembly, USBADC to DatexS/5 with BUPI4Some B-UPI4NET boards are fittedwith a 4-way LEMO socket and othersare fitted with a 7-way MiniDIN socketmarked X7 for the SynchronisationConnector. Model numbers do notidentify which type of socket is fitted,the only way is to look. If it is a 7-wayMiniDIN an Li11066 is required.Pressure P1 must be zeroed beforeconnecting the cable.YFile: USB ADC Cable Assemblies for connection to Patient Monitors 01Feb18.docPage 2 of 7Printed: 16:27 01/02/18

B.P. MonitorManufacturerModel No.ConnectorType on CableAssemblyGE DatexS/5 fitted with a B-UPI4NETboard which has a 7-wayMiniDIN socket.7-wayMiniDINPlugDrawing of the Socket on thePatient MonitorLiDCO ItemNumber 5060110522262CableAssembly, USBADC to GEMarquetteTRAM 451Some B-UPI4NET boards are fittedwith a 4-way LEMO socket and othersare fitted with a 7-way MiniDIN socketmarked X7 for the SynchronisationConnector. Model numbers do notidentify which type of socket is fitted,the only way is to look. If it is a 4-wayLEMO, an Li11065 is required.Pressure P1 must be zeroed beforeconnecting the cable.YThis Li11066 is also suitable for theMarquette TRAM 451 andCARESCAPE B650 & B850 without aPDM, see below.GE Marquette6000 Series6-way LEMO7000 SeriesPlugwith TRAM 250 or TRAM 450unitsLi1114005060110522552CableAssembly, USBADC to GE6/7000GE MarquetteCARESCAPE B450, B650 and 7-wayB850 without a PDM (Patient MiniDINPlugData Module) attached.Li1106605060110522262CableAssembly, USBADC to GEMarquetteTRAM 451YIf a PDM is attached to aCARESCAPE B450, B650 or B850monitor the Defib/Sync connector onthe frame is disabled. In this situationan Li11064 Cable Assembly, PulseCOto GE Marquette PDM Port is required.YThis Li11066 is also suitable for theMarquette TRAM 451and Datex S/5fitted with a B-UPI4NET board.GE MarquetteMonitors with PDM Port, e.g.Solar 8000,CARESCAPE B450,CARESCAPE B650,CARESCAPE B8509-way PDMPort (special)PlugLi1106405060110522248CableAssembly, USBADC to GEPDM PortNote: When the PDM module isplugged into the CARESCAPE 450,650 or 850 the Defib/Sync socket onthe frame of the monitor becomesinactive.YFile: USB ADC Cable Assemblies for connection to Patient Monitors 01Feb18.docPage 3 of 7Printed: 16:27 01/02/18

B.P. MonitorManufacturerModel No.ConnectorType on CableAssemblyLiDCO ItemNumber &UDI/GTINLiDCODescriptionCommentsGE MarquetteTRAM 451Dash 3000Dash 4000Dash 50007-way MiniDIN Plug, nonlatching,polarising lugLi1106605060110522262CableAssembly, USBADC to GEMarquetteTRAM 451This cable also suits the Datex S/5fitted with a B-UPI4NET board, andCARESCAPE B450, B650 & B850without a PDM.GE MarquetteTram Rac 4A for Solar 800015-way D PlugLi1118805060110522897CableAssembly, USBADC to GETramRac 4AYGeneral PurposeN.A.BNC PlugLi1107005060110522309CableAssembly, USBADC to BNCYMindrayIn Europe the monitors are9-way Micro-Dcalled BeneView T5 & T8 and plugin North America the samemonitors are called DPM 6 andDPM 7. These modelsmanufactured after Nov’09 andfitted with a Mirco-Dconnector are supported.Li1113805060110522538CableAssembly, USBADC toMindray T5 toT9MindrayBeneview T1,either stand aloneor docked in a T5 or T8 as anMPM12-way CircularLi1113605060110522514CableIBP1 must be arterial pressure.Assembly, USBADC toMindray MPMYMindrayiPM range of monitors.Also iMEC range of monitorsthat have invasive pressuremonitoring fitted.20-way MDRplugLi1113705060110522514CableAssembly, USBADC toMindray iPMYDrawing of the Socket on thePatient MonitorStockItemThe 9-way Micro-D socket on the rearof the T5 and T8 is disabled when theT1 (the MPM that has the integralscreen) is docked in the chassis. In thissituation use Li11136.YYFile: USB ADC Cable Assemblies for connection to Patient Monitors 01Feb18.docPage 4 of 7Printed: 16:27 01/02/18

B.P. MonitorManufacturerModel No.Nihon KohdenConnectorType on CableAssemblyLiDCO ItemNumber &UDI/GTINLiDCODescriptionCommentsLifeScope VS BSM-30005-way SpecialSeries:PlugECG/BP OUT is only availableon the following models if theQI-372P optional interface isinstalled at the factory:BSM-3532, BSM-3552, BSM3562, BSM-3733, BSM-3753and BSM-3763Li1106705060110522279CableAssembly, USBADC to NihonKhoden 5-wayECG/BP OUTMust have QI-372P interface installed.To output a blood pressure waveformfrom the ECG/BP OUT socket, youmust connect the IBP cable to theMULTI 1 or Multi-parameter 1 socket.If the IBP Cable is connected to anyother socket, the expected bloodpressure waveform is not output fromthe ECG/BP OUT socket.YNihon KohdenLifescope BSM-5100A, BSM5100K, BSM-5105K, BSM5106A, etc. BSM-6000 series5-way SpecialPlugLi1106705060110522279CableAssembly, USBADC to NihonKhoden 5-wayECG/BP OUTTo output a blood pressure waveformfrom the ECG/BP OUT socket, youmust connect the IBP cable to theMULTI 1 or Multi-parameter 1 socket.If the IBP Cable is connected to anyother socket, the expected bloodpressure waveform is not output fromthe ECG/BP OUT socket.YNihon KohdenLifescope 9,Lifescope 14¼” Stereo JackPlugLi1106305060110522231CableAssembly, USBADC to Philips#C01 BPModulePhilips (formerly IntelliVue MP40 and above,Agilent, formerly i.e. those with a rack to acceptHewlett Packard) the M1006B with Option #C01Pressure Module3.5mm StereoJack Plug or ¼”Stereo JackPlugLi1106305060110522231CableAssembly, USBADC to Philips#C01 BPModuleDrawing of the Socket on thePatient MonitororStockItemYThe Philips monitor must be fitted witha M1006B Option #C01 PressureModule with Analog Pressure Output.YThis module should work with allchassis systems, i.e. MP40 and above.This cable assembly is also suitable forSpacelabs 90601A & 90603Amonitors.Siemens (seeDraeger)SC7000, SC8000, SC9000,SC9000XL Patient Monitors14-way MDRPlug, X10Li1106805060110522286CableAnalogue output must be configured toAssembly, USB ART (not P1).ADC to DrägerYFile: USB ADC Cable Assemblies for connection to Patient Monitors 01Feb18.docPage 5 of 7Printed: 16:27 01/02/18

B.P. MonitorManufacturerModel No.ConnectorType on CableAssemblySpacelabs90470 Pressure & ECGModule90402 Pressure Module90305 Main FrameSpacelabs90601A & 90603A MonitorsSpacelabsCommand Modules 90496 &91496These command modulesinterface with the SL2400(91369), SL2600 (91370),SL2700 and SL2800 monitorsand the previous rangeSL1030/SL1050, UV1500,UV1600, UV1700LiDCO ItemNumber &UDI/GTINLiDCODescriptionCommentsSwitchcraftTT253 .173” 3pole PlugLi1106905060110522293CableAssembly, USBADC toSpacelabsObsolete command modules andmonitors.The 90470 module has 2 High LevelOutput sockets (HLO1 & HLO2)situated in the top right hand corner ofthe front panel. The factory defaultsettings for these outlets is HLO1 ECG and HLO2 P1 and these can bechanged through jumper settings on thefront of the CPU board.Y3.5mm StereoJack Plug or ¼”Stereo JackPlugLi1106305060110522231CableObsolete monitors.Assembly, USB This cable assembly is also suitable forADC to Philips Philips monitors.#C01 BPModuleYLi1106905060110522293CableAssembly, USBADC toSpacelabsYDrawing of the Socket on thePatient MonitororSwitchcraftTT253 .173” 3pole PlugStockItemThe Ultraview Command Modules thatsupport invasive blood pressure are:90496-B, -C, -J , -K, -L, -N, and -O (allbut -A)91496-A, -B, and -C (all but -I)These modules have 2 High LevelOutput sockets (HLO1 & HLO2)situated in the top right hand corner ofthe front panel. The factory defaultsettings for these outlets is HLO1 ECG and HLO2 P1 and these can bechanged through the ModuleConfiguration Manager should there bea requirement to do so.File: USB ADC Cable Assemblies for connection to Patient Monitors 01Feb18.docPage 6 of 7Printed: 16:27 01/02/18

B.P. MonitorManufacturerModel No.ConnectorType on CableAssemblySpacelabsXprezzonSwitchcraftTT253 .173” 3pole PlugDrawing of the Socket on thePatient MonitorLiDCO ItemNumber 5060110522293CableAssembly, USBADC toSpacelabsLi11069 must be plugged into theHLO1/2 port on the Spacelabs monitor,and the monitor must be configuredthus:1. Select ECG on main screen2. Select ‘setup’ along the bottom barmenu3. Select ‘config’ along the bottom barmenu4. Select the hidden key. Press alongthe bottom bar until you hear a click,then press this same spot THREEtimes.5. This will bring up a new bottommenu bar, select ‘user settings’6. Select ECG7. Press ‘next page’ until you reachHLO parameters. Once you see it,press the down cursor to select.8. This needs to be set on P1/P2, not onany of the other settings.The arterial pressure transducer mustbe connected to P1.YLiDCO Ltd16 Orsman Road London N1 5QJ UKTel: 44 (0)20 7749 1500Fax: 44 (0)02 7749 1501File: USB ADC Cable Assemblies for connection to Patient Monitors 01Feb18.docPage 7 of 7Printed: 16:27 01/02/18

GE Marquette Monitors with PDM Port, e.g. Solar 8000, CARESCAPE B450, CARESCAPE B650, CARESCAPE B850 9 -way PDM Port (special) Plug Li11064 05060110522248 Cable Assembly, USB ADC to GE PDM Port Note: When the PDM module is plugged into the CARESCAPE 450, 650 or 850 th

Related Documents:

GE Datex Cardiocap II 25-way D Plug : Li10252 Cable Assembly, PulseCO to GE Datex Cardiocap II This monitor produces a non-standard analogue blood pressure waveform. Consequently we do not support this monitor. N NOTE: Datex / GE patient monitors can be configured in several different ways. From the model number alone one can not foretell with .

Bruksanvisning för bilstereo . Bruksanvisning for bilstereo . Instrukcja obsługi samochodowego odtwarzacza stereo . Operating Instructions for Car Stereo . 610-104 . SV . Bruksanvisning i original

Catalogue 2020-21 Life Line Plus S3 (HRFR) Cable Life Guard (FR-LSH) Cable Life Shield (HFFR) Cable Multicore Round Cable Shielded Cables Flat Submersible Cable Telephone Switch Board Cable LAN Cable CCTV Cable Co-Axial TV Cable Speaker Cable Presenting Domestic Cable Range for Safer, Securer Homes.

instrumentation tray cable 10 general purpose cable 12 instrumentation tray exposed run direct burial cable 14 power tray exposed run direct burial cable 16 industrial ethernet cable 18 fieldbus technology cable 20 extremelife cable 22 flexlife cable 24 weldlife cable 26 armorfast instrumentation cable 28 flexible service cable

10 tips och tricks för att lyckas med ert sap-projekt 20 SAPSANYTT 2/2015 De flesta projektledare känner säkert till Cobb’s paradox. Martin Cobb verkade som CIO för sekretariatet för Treasury Board of Canada 1995 då han ställde frågan

service i Norge och Finland drivs inom ramen för ett enskilt företag (NRK. 1 och Yleisradio), fin ns det i Sverige tre: Ett för tv (Sveriges Television , SVT ), ett för radio (Sveriges Radio , SR ) och ett för utbildnings program (Sveriges Utbildningsradio, UR, vilket till följd av sin begränsade storlek inte återfinns bland de 25 största

Hotell För hotell anges de tre klasserna A/B, C och D. Det betyder att den "normala" standarden C är acceptabel men att motiven för en högre standard är starka. Ljudklass C motsvarar de tidigare normkraven för hotell, ljudklass A/B motsvarar kraven för moderna hotell med hög standard och ljudklass D kan användas vid

LÄS NOGGRANT FÖLJANDE VILLKOR FÖR APPLE DEVELOPER PROGRAM LICENCE . Apple Developer Program License Agreement Syfte Du vill använda Apple-mjukvara (enligt definitionen nedan) för att utveckla en eller flera Applikationer (enligt definitionen nedan) för Apple-märkta produkter. . Applikationer som utvecklas för iOS-produkter, Apple .