WELLMATECOMPOSITEPRESSURE TANKSWATER QUALITY SYSTEMS

PENTAIR WELLMATE OFFERS DEALERSMORE ADVANTAGES, MORE SOLUTIONS,FOR MORE APPLICATIONSA GROWING CUSTOMER BASEIn the residential, commercial, andagricultural markets of the world,Pentair† Wellmate† composite tankshave long been the tank of choicefor their unmatched performanceover steel. As the recognized leaderin composite pressure tank design,Pentair Wellmate water systems giveyou more to sell.With unique features that translateinto real benefits for your customers,Wellmate by Pentair sets you apartfrom the competition.A MATERIAL DIFFERENCEFrom the high-density polyethyleneinner liner, to the fiberglass-woundand epoxy resin-sealed outer shell,Pentair Wellmate tanks do notcontain steel, so they will not rust.What they can do is make everythingeasier. Wellmate by Pentair tanksrequire little or no maintenancebecause they won’t dent and they donot have paint to scratch and touchW E LLM AT Eup. Their light weight – half that ofsteel tanks – makes them easier andfaster to install. In fact, most can behandled by a single installer, keepingcosts down. Pentair Wellmate tanksare certified to NSF/ANSI std. 61section 8 and Annex G and are 100%lead-free. In addition, they will notintroduce undesirable chemicals orelements into the water.A PRODUCT THAT’SWORTH MOREInnovative Pentair Wellmatesolutions for water storage andpressure boosting applicationsoffer you a world class productthat’s worth more. From initialdesign through promised delivery,quality is a hallmark of Wellmateby Pentair tanks. State-of-the-artequipment, the best materialsand an ISO-9001 certifiedmanufacturing facility guaranteethat our one-piece compositeconstruction is second to none.ONGOING DEALER SUPPORTAs a Pentair Wellmate dealer,you’ll enjoy total dealer support.Wellmate by Pentair tanks are onlysold through a network of selectprofessional dealers, giving youa real opportunity to make yourmark. In addition, Pentair Wellmatedealers enjoy the benefits of salestraining programs, seminarsand technical support, as wellas marketing support and dealerincentive programs. Want to knowmore about Wellmate by Pentair andthe edge it gives its dealers? Callyour Pentair Wellmate distributoror visit www.wellmate.com for moreinformation.

RESIDENTIALCOMMERCIALAGRICULTURALFor well systems, water storage,and pressure boosting.TABLE OFCONTENTS2-3LOW-PROFILE SERIES4-5WM-SERIES6-7 UT-QUICK CONNECT SERIES8-9HP-QUICK CONNECT SERIES10-11E-SERIES12 UNIVERSAL/HP AERATIONTANKS13 RESIDENTIAL TANKREPLACEMENT GUIDECO M PO S I TE W ATE R S Y STE M P RE S S U RE TANKS1

LP-SERIES (QUICK CONNECT AND CLASSIC MODELS)LOW-PROFILE CAPTIVE AIR TANKSBIG ON PERFORMANCE, SMALL ON SPACEDesigned for height-restrictedapplications such as mobile homes,crawl spaces and closets, ourcompact LP-Series pressure tanksgive you added flexibility in smallspace residential applications.Plus they offer you these distinctadvantages: Available in two styles:– QUICK CONNECT drainassembly, heavy gauge polymeraircell– CLASSIC PVC drain assembly,heavy gauge polymer aircellAPPLICATIONS H ighest drawdown in the Industryfor its Profile– Mobile Homes A ircell, – easier to service inthe field– Closets– Crawl Spaces Q uick Change Connection –easier to install L ightweight – easier tomaneuverTested and Certified by theWater Quality Association(WQA) to NSF/ANSI-61,Section 8 and NSF/ANSI 372.2W E LLM AT E

CLASSICQUICK CONNECTCLASSIC1122345A345BHERE ARE THE FEATURES THAT SET US APART1 urable, heavy gauge polymerDaircell is fully replaceable2 ne-piece seamless inner shellOis molded of high-densitypolyethylene3 uter shell is composed ofOcontinuous fiberglass strandssealed with high-grade epoxy resin5A uick connect, bottom inlet/Qoutlet assembly is custom moldedof high-impact engineered polymer4 turdy, molded polymeric baseSis corrosion and impact proof5B ottom inlet/outlet assemblyBis custom molded of highimpact PVCSPECIFICATIONS – CLASSIC QUICK CONNECTMODELCAPACITYGAL / LITERMAXIMUMOPERATINGPRESSUREPSI / kPa / BARWM-6LP / WM-LP-075 QC19.3 / 73125 / 862 / 8.66.0 / 22.7WM-10LP / WM-LP-130 QC34.5 / 131125 / 862 / 8.610.7 / 40.5OVERALLHEIGHT*INCH / CMHEIGHT*INLET/OUTLETTO FLOORINCH / CMSYSTEMCONNECTIONASSEMBLYWEIGHT*LB / KG24 / 6120 / 512.25 / 5.71" male NPT25.2 / 11.424 / 6128 / 712.25 / 5.71" male NPT32.85 / 14.9OVERALLHEIGHT*INCH / CMHEIGHT*INLET/OUTLETTO FLOORINCH / CMSYSTEMCONNECTIONASSEMBLYWEIGHT*LB / KGDRAWDOWNDIAMETER*30/50 SETTING**INCH / CMGAL/LITERSPECIFICATIONS – CLASSICMODELCAPACITYGAL / LITERMAXIMUMOPERATINGPRESSUREPSI / kPa / BARDRAWDOWNDIAMETER*30/50 SETTING**INCH / CMGAL/LITERWM-6LP / WM-LP-075 C19.3 / 73125 / 862 / 8.65.8 / 21.924 / 6120 / 512.25 / 5.71" male NPT22.75 / 10.3WM-10LP / WM-LP-130 C34.5 / 131125 / 862 / 8.610.4 / 39.224 / 6128 / 712.25 / 5.71" male NPT29.5 / 13.4NOTE: Maximum external operating temperature 120 F (49 C). Maximum internal operating temperature 100 F (38 C). Minimum operatingtemperature 40 F (4 C).* Diameter, height and weight may vary slightly without notice.** In keeping with current industry standards, drawdown factors are based on Boyle’s law. Actual drawdowns will vary depending upon systemvariables, including the accuracy and operation of the pressure switch and gauge and operating temperature of the system.CO M PO S I TE W ATE R S Y STE M P RE S S U RE TANKS3

WM-SERIES (CLASSIC & CLASSIC QUICK CONNECT MODELS)CAPTIVE AIR TANKSEASY TO INSTALL, MAINTAIN, AND SERVICEOur WM-Series offers featuresand benefits that steel tanks can’tmatch. From their corrosion-proofcomposite construction to theirlighter weight, easier maintenanceand less expensive installation,WM-Series pressure tanks are thepreferred choice of professionals,especially when the followingadvantages are added to the mix: Available in two styles:– QUICK CONNECT drainassembly, heavy gauge polymeraircell– CLASSIC drain assembly, heavygauge polymer aircell Easy to carry E asy and Less Costly to Install –usually requiring only one personand fewer man-hours G reater Drawdown thanComparably-Sized Steel Tanks –for greater efficiencyAPPLICATIONS– Residential– Light Commercial– Pressure Boosting Won’t Rust in CorrosiveEnvironments – particularlyimportant in agricultural andlivestock applications, andcoastal regions Replaceable Aircell – for easierfield servicingTested and Certified by theWater Quality Association(WQA) to NSF/ANSI-61,Section 8 and NSF/ANSI 372.SPECIFICATIONS – CLASSIC QUICK CONNECTMODELCAPACITYGAL / LITERMAXIMUMOPERATINGPRESSUREPSI / kPa / BARWM-4 / WM0060 QC14.5 / 55125 / 862 / 8.64.5 / 17.016 / 41WM-6 / WM0075 QC19.8 / 75125 / 862 / 8.66.1 / 23.1WM-9 / WM0120 QC29.5 / 112125 / 862 / 8.69.1 / 34.4OVERALLHEIGHT*INCH / CMHEIGHT*INLET/OUTLETTO FLOORINCH / CMSYSTEMCONNECTIONASSEMBLYWEIGHT*LB / KG26 / 661.75 / 4.41" male NPT16.9 / 7.616 / 4132 / 811.75 / 4.41" male NPT20.85 / 9.516 / 4144 / 1121.75/ 4.41" male NPT28.80 / 13.0DRAWDOWNDIAMETER*30/50 SETTING**INCH / CMGAL/LITERWM-12 / WM0150 QC40.3 / 153125 / 862 / 8.612.5 / 47.316 / 4157 / 1451.75/ 4.41" male NPT35.05 / 15.9WM-14WB / WM0180 QC47.1 / 178125 / 862 / 8.614.6 / 55.321 / 5341.3 / 1052.25 / 5.71-1/4" male NPT46.27 / 21.0WM-20WB / WM0235 QC60.0 / 227125 / 862 / 8.618.5 / 70.024 / 6141.5 / 1052.25 / 5.71-1/4" male NPT52.87 / 24.0WM-23 / WM0300 QC79.6 / 301125 / 862 / 8.624.6 / 93.121 / 5362 / 1572.25 / 5.71-1/4" male NPT71.07 / 32.3WM-25WB / WM0330 QC86.7 / 328125 / 862 / 8.626.8 / 101.524 / 6155.25 / 1402.25 / 5.71-1/4" male NPT77.22 / 35.0WM-35WB / WM0450 QC119.7 / 453125 / 862 / 8.637.0 / 140.124 / 6174.25 / 1892.25/ 5.71-1/4" male NPT102 / 46.4NOTE: Maximum external operating temperature 120 F (49 C). Maximum internal operating temperature 100 F (38 C). Minimum operating temperature 40 F (4 C).* Diameter, height and weight may vary slightly without notice.** In keeping with current industry standards, drawdown factors are based on Boyle’s law. Actual drawdowns will vary depending upon system variables, includingthe accuracy and operation of the pressure switch and gauge and operating temperature of the system.4W E LLM AT E

CLASSICQUICK CONNECTHERE ARE THE FEATURESTHAT SET US APART Heavy-gauge, polymeraircell is chlorine-resistantand fully replaceable11 ne-piece seamless innerOshell is molded of highdensity polyethylene23 uter shell is composed ofOcontinuous fiberglassstrands sealed with highgrade epoxy resin4 turdy, molded polymericSbase is corrosion- andimpact-proof5A5BCLASSIC1223 uick connect, bottom inlet/Qoutlet assembly is custommolded of high-impactengineered polymer35A ottom inlet/outlet oneBpiece drain is custommolded of high-impact PVC5B44SPECIFICATIONS – CLASSICMODELCAPACITYGAL / LITERMAXIMUMOPERATINGPRESSUREPSI / kPa / BARWM-4 / WM0060 C14.5 / 55125 / 862 / 8.6DRAWDOWNDIAMETER*30/50 SETTING**INCH / CMGAL/LITER4.5 / 17.016 / 41OVERALLHEIGHT*INCH / CMHEIGHT*INLET/OUTLETTO FLOORINCH / CMSYSTEMCONNECTIONASSEMBLYWEIGHT*LB / KG26 / 661.75 / 4.41" male NPT14.5 / 6.6WM-6 / WM0075 C19.8 / 75125 / 862 / 8.66.1 / 23.116 / 4132 / 811.75 / 4.41" male NPT17.75 / 8.1WM-9 / WM0120 C29.5 / 112125 / 862 / 8.69.1 / 34.416 / 4144 / 1121.75/ 4.41" male NPT24.75 / 11.265.7 / 29.8WM-12 / WM0150 C40.3 / 153125 / 862 / 8.612.5 / 47.321 / 5357 / 1452.25 / 5.71-1/4" male NPTWM-14WB / WM0180 C47.1 / 178125 / 862 / 8.614.6 / 55.324 / 6141.3 / 1052.25 / 5.71-1/4" male NPT50 / 22.7WM-20WB / WM0235 C60.0 / 227125 / 862 / 8.618.5 / 70.024 / 6141.5 / 1052.25 / 5.71-1/4" male NPT72.75 / 33.0WM-23 / WM0300 C79.6 / 301125 / 862 / 8.624.6 / 93.121 / 5362 / 1572.25 / 5.71-1/4" male NPT43 / 19.5WM-25WB / WM0180 C86.7 / 328125 / 862 / 8.626.8 / 101.524 / 6155.25 / 1402.25 / 5.71-1/4" male NPT72.75 / 33.0WM-35WB / WM0450 C119.7 / 453125 / 862 / 8.637 / 140.124 / 6174.25 / 1892.25 / 5.71-1/4" male NPT95 / 43.1NOTE: Maximum external operating temperature 120 F (49 C). Maximum internal operating temperature 100 F (38 C). Minimum operating temperature 40 F (4 C).* Diameter, height and weight may vary slightly without notice.** In keeping with current industry standards, drawdown factors are based on Boyle’s law. Actual drawdowns will vary depending upon system variables, including the accuracy and operation of the pressure switch and gauge and operating temperature of the system.CO M PO S I TE W ATE R S Y STE M P RE S S U RE TANKS5

UT-SERIESUNIVERSAL RETENTION TANKSDO YOU HAVE CONTACT WITH CHEMICALS, CHLORINE &HYDROGEN SULFIDE? GO WITH THE PROS AND CHOOSE UTThere’s no better tank choicefor water treatment than ourUT-Quick Connect Series.Composite construction makesthe entire line impervious to thechemicals found in aggressivewater. Plus the following advantagesgive our UT-Quick Connect Seriesthe kind of application versatilitydealers want:6W E LLM AT E Inlet/Outlet PVC Pipe Connections –allow straight through T connectionon bottom of tank for ease of piping B lowdown Valve – for easy removalof sludge from bottom of tank H ydropneumatic Convertible –optional air volume controlassembly and micronizer allow forquick and easy tank conversion.Dealers no longer need to stockmore than one kind of air-overwater pressure tankAPPLICATIONS– Contact Tank forWater Treatment– Hydropneumatic(with purchased accessories)

HERE ARE THE FEATURESTHAT SET US APART1 Standard 1" ID / 1-1 4" QuickConnect Socket2 ne piece, seamless innerOshell molded of premiumhigh-density polyethylenewhich provides impact andcorrosion resistance2 iles of fiberglass filamentMcovered with epoxy resinproduce superior strength ina light-weight design4 Additional drain port5 urved bottom dome designCmaximizes contact time andfacilitates sludge removal.3CHEMICAL TANK -1 4" socket inlet/outlet1PVC pipe connectionsoffer maximum applicationflexibility5PUMP31Note: Vacuum breaker required.4WATER INTO BLOWDOWN VALVESPECIFICATIONSQUICK CONNECTMODELCAPACITYGAL / LITERMAXIMUMOPERATINGPRESSUREPSI / kPa / BARDIAMETER*INCH / CMOVERALLHEIGHT*INCH / CMHEIGHT*INLET/OUTLETTO FLOORINCH / CMUT-30 / WM-UT-110 / CE30 / 11475 / 500 / 5.016 / 4144.5 / 1131.5 / 3.8SYSTEM CONNECTIONTOPBOTTOMASSEMBLYWEIGHT*LB / KG1-1/4" Socket Q.C.1-1/4" Socket25 / 11.3UT-40 / WM-UT-150 / CE40 / 15175 / 500 / 5.016 / 4157.25 / 1451.5 / 3.81-1/4" Socket Q.C.1-1/4" Socket28 / 12.7UT-40SQ / WM-UT-150-SQ / CE40 / 15175 / 500 / 5.021 / 5336 / 912 / 5.11-1/4" Socket Q.C.1-1/4" Socket33 / 15.0UT-80 / WM-UT-300 / CE80 / 30375 / 500 / 5.021 / 5362.75 / 1592 / 5.11-1/4" Socket Q.C.1-1/4" Socket43 / 19.5UT-120 / WM-UT-450 / CE120 / 45475 / 500 / 5.024 / 6172.25 / 1862 / 5.11-1/4" Socket Q.C.1-1/4" Socket63 / 28.6NOTE: Maximum external operating temperature 120 F (49 C).Maximum internal operating temperature 100 F (38 C).Minimum operating temperature 40 F (4 C).Tested and Certified by theWater Quality Association(WQA) to NSF/ANSI-61,Section 8 and NSF/ANSI 372.*Diameter, height and weight may vary slightly without notice.ACCESSORIES(For hydropneumatic conversion)(Consult factory for correct size)Air Volume Control AssemblyPart #CH3929-5MicronizerPart #CH19426Vacuum Breaker 1/4" NPTAir Volume Control AssemblyMicronizerVacuum BreakerNOTE: Flexible connectors must be installed between hard piping and tank openings. These pressure vessels are rated for an internal negativepressure of 5" HG (17 Pa) vacuum below atmospheric.If negative pressure could ever exceed 5" Hg (17 Pa), an adequate vacuum breaker must alsobe properly installed. Failure to install flex connection properly, or improper installation of a vacuum breaker when required, may void the warranty.CO M PO S I TE W ATE R S Y STE M P RE S S U RE TANKS7

HP-SERIESHYDROPNEUMATIC AIR/WATER TANKSTHE TOUGHEST TANKS FOR YOUR MOST DIFFICULT INSTALLSIron and sulfur removal? Methaneand other undesirable well gases?You need our HP-Quick ConnectSeries of hydropneumatic tanks.These high performance tankscan be used for aggressive water,or as an open system where air isintroduced to oxidize and aerate.All this, plus these other keyadvantages: Large Drawdown Ratio – forincreased efficiency.8W E LLM AT E Adapter and UT Drain Assembly –(sold separately) – allows you toadd a 1" riser pipe to increaseaeration of water (See page 12.) Self-Adjusting Air Volume Control –for system flexibility and ease ofinstallation.Tested and Certified by theWater Quality Association(WQA) to NSF/ANSI-61,Section 8 and NSF/ANSI 372.APPLICATIONS– Sulfur and Iron Water Treatment– Hypochloride Environments– Release of Methane or OtherWell Gases

1HERE ARE THE FEATURESTHAT SET US APART12345678 4" vent line. 360 rotating1threadless connection Top-mounted air volumecontrol provides 50% or moredrawdown than similar sizedconventional tanks Miles of fiberglass filamentcovered with epoxy resinproduce superior strength in alight-weight design Self-adjusting air volumecontrol – a Pentair Wellmateexclusive One piece, seamless innershell molded of premiumhigh-density polyethylene whichprovides impact and corrosionresistance Convex bottom design withtop-mounted air volume controlmaximizes drawdown 1-1 4" socket inlet/outletPVC pipe connections offermaximum application flexibility Blowdown port with 1 2" NPTconnection23456MICRONIZER7INLET8TO SERVICESPECIFICATIONSQUICK CONNECTMODELCAPACITYGAL / LITERMAXIMUMOPERATINGPRESSUREPSI / kPa / BARDRAWDOWNDIAMETER*30/50 SETTING**INCH / CMGAL/LITEROVERALLHEIGHT*INCH / CMHEIGHT*INLET/OUTLETTO FLOORINCH / CMSYSTEM CONNECTIONTOPBOTTOMASSEMBLYWEIGHT*LB / KGHP-7/WM-HP-11030 / 11475 / 500 / 5.06.6 / 25.016 / 4143.75 / 1111.5 / 3.81/4" vent line 1-1/4" Socket26 / 11.8HP-9/WM-HP-15040 / 15175 / 500 / 5.09.0 / 34.116 / 4156.5 / 1441.5 / 3.81/4" vent line 1-1/4" Socket29 / 13.2HP-8SQ/WM-HP-150SQ40 / 15175 / 500 / 5.08.0 / 30.321 / 5335.25 / 902 / 5.11/4" vent line 1-1/4" Socket34 / 15.4HP-18/WM-HP-30080 / 30375 / 500 / 5.017.8 / 67.421 / 5362 / 1572 / 5.11/4" vent line 1-1/4" Socket44 / 20.0HP-26/WM-HP-450120 / 45475 / 500 / 5.025.5 / 96.524 / 6172.5 / 1842 / 5.11/4" vent line 1-1/4" Socket64 / 29.0NOTE: Maximum external operating temperature 120oF (49oC). Maximum internal operating temperature 100oF (38oC). Minimum operatingtemperature 40oF (4oC).* Diameter, height and weight may vary slightly without notice.** In keeping with current industry standards, drawdown factors are based on Boyle’s law. Actual drawdowns will vary depending upon systemvariables, including the accuracy and operation of the pressure switch and gauge and operating temperature of the system.ACCESSORIESPart #CH3929-5MicronizerPart #CH19426Vacuum Breaker 1/4" NPTMicronizerVacuum BreakerNOTE: Flexible connectors must be installed between hard piping and tank openings. These pressure vessels are rated for an internal negativepressure of 5" HG (17 Pa) vacuum below atmospheric. If negative pressure could ever exceed 5" Hg (17 Pa), an adequate vacuum breaker must alsobe properly installed. Failure to install flex connection properly, or improper installation of a vacuum breaker when required, may void the warranty.CO M PO S I TE W ATE R S Y STE M P RE S S U RE TANKS9

E-SERIESCAPTIVE AIR AND RETENTION TANKSMAXIMUM STORAGE, MINIMUM HEADACHESWider pressure switch settingson our E-Series tanks allow formaximum water storage duringperiods of peak demand. As acaptive air tank, the E-Seriescan handle up to 125 psi/8.6 baroperating pressure. Plus the highvolume, high-pressure tanks offerthese benefits: Retention Tank Capability –without the aircell, can function asa high capacity retention tank forwater storage and treatment10W E L L M AT E H eavy Gauge Polymer Aircell –offers a longer life than bladdersor diaphragms Wider Range of Pressure Settings –for greater application versatility Pre-Installed Inlet/OutletAssembly – with systemconnections to save timeand moneyTested and Certified by theWater Quality Association(WQA) to NSF/ANSI-61,Section 8 and NSF/ANSI 372.APPLICATIONS– High Volume Water Storage– Water Storage Treatment

HERE ARE THE FEATURESTHAT SET US APART1 ircell – heavy gauge polymer;Acaptive air tank only2 essel – fiberglass and epoxyVfilament wound onto a onepiece molded liner3 ase – glass filled sheetBmolding compoundCAPTIVE AIR TANKRETENTION TANK12233Our E-Series tanks are also available as a retention tank for water storage/treatment.SPECIFICATIONSCAPACITYGAL / LITERMAXIMUMOPERATINGPRESSUREPSI / kPa / BARWM-60187 / 707125 / 862 / 8.655.2 /209WM-80264 / 999125 / 862 / 8.678.0 / 295RT-200187 / 707125 / 862 / 8.6N/A30 / 7679 / 2017.5 / 192" NPSM2" MNPT234 / 106.14RT-270264 / 999125 / 862 / 8.6N/A36 / 9181 / 2068.0 / 202" NPSM2" MNPT292 / 132.45MODELOVERALLHEIGHT*INCH / CMHEIGHT*INLET/OUTLETTO FLOORINCH / CM30 / 7679 / 20136 / 9181 / 206DRAWDOWNDIAMETER*30/50 SETTING**INCH / CMGAL/LITERSYSTEM CONNECTIONTOPBOTTOMASSEMBLYWEIGHT*LB / KG7.5 / 19N/A2" FNPT234 / 106.148.0 / 20N/A2" FNPT292 / 132.45CAPTIVE AIR TANKRETENTION TANKNOTE: Maximum external operating temperature 120 F (49 C). Maximum internal operating temperature 100 F (38 C). Minimum operatingtemperature 40 F (4 C).* Diameter, height and weight may vary slightly without notice.** In keeping with current industry standards, drawdown factors are based on Boyle’s law. Actual drawdowns will vary depending upon systemvariables, including the accuracy and operation of the pressure switch and gauge and operating temperature of the system.CO M PO S I TE W ATE R S Y STE M P RE S S U RE TANKS11

1UT/HPAERATIONTANKS1HOW TO AIR OUTUNDESIRABLE GASESGot a problem with undesirablewell gases? These tanks have beendesigned to introduce air to oxidizeand aerate, minimizing or eveneliminating both methane gas andhydrogen sulfide gas which isdetectable by its rotten egg odor.These tough-performing tanks alsooffer the following: Large Drawdown Ratio – forincreased efficiency Self Adjusting Air Volume ControlSystem – for flexibility and ease ofinstallation /4" vent line. 360 1rotating threadlessconnection. Vacuumbreaker required* (Referto “note” below)2Water level3 ap and pipe withC1/4" drilled holes todistribute flow. Minimum12-17 holes required.(not supplied w/tank)23744 iser tube of 1" pipeR(not supplied w/tank)5 Adapter P/N CH110686 acuum breaker requiredVfor HP applications7 Air volume control system8 Micronizer5Adjustment knobIndicator68INLETAir Inlet Composite Construction – forincreased tank lifeTO SERVICEWARNING: To avoid health or environmental hazardsfrom gas accumulation, plumb the top fitting to ventoff gas to a safe area.* Pentair Wellmate does not guarantee sizingrequirements or the successful removal ofodors and gases. It is the responsibility ofthe contractor or water treatment specialistto assess the many variables involved andselect the proper tank.SPECIFICATIONSACCESSORIESQUICK CONNECTMODELCAPACITYGAL / LITER1" RISER TUBELENGTH(INCHES)1/2 AVC(TUBE ONLY)(INCHES)AVC OVERALLLENGTH(INCHES)UT-30 / HP-730 / 11424.0023.2534.88UT-40SQ / HP-8SQ40 / 15116.0014.5026.15UT-40 / HP-940 / 15137.5035.5047.12UT-80 / HP-1880 / 30342.7540.0051.62UT-120 / HP-26120 / 45453.0046.5058.12Part # CH3929-5MicronizerPart # CH19426Vacuum Breaker 1/4" NPTPart # CH11068AdapterMicronizerVacuum BreakerNOTE: Maximum external operating temperature 120 F (49 C). Maximum internal operating temperature 100 F (38 C). Minimum operatingtemperature 40 F (4 C).Diameter, height and weight may vary slightly without notice.I n keeping with current industry standards, drawdown factors are based on Boyle’s law. Actual drawdowns will vary depending upon systemvariables, including the accuracy and operation of the pressure switch and gauge and operating temperature of the system.NOTE: Flexible connectors must be installed between hard piping and tank openings. These pressure vessels are rated for an internal negativepressure of 5" HG (17 Pa) vacuum below atmospheric. If negative pressure could ever exceed 5" Hg (17 Pa), an adequate vacuum breaker must alsobe properly installed. Failure to install flex connection properly, or improper installation of a vacuum breaker when required, may void the warranty.Tested and Certified by theWater Quality Association(WQA) to NSF/ANSI-61,Section 8 and NSF/ANSI 372.12W E L L M AT E

RESIDENTIAL TANKREPLACEMENT 1CM1001 CM1002ClaytonMarkWM-4/WM-6LP/WM0060 QC WM-LP-075 QCWM-6/WM0075 QCWM-9/WM-10LP/WM-11/WM0120 QC WM-LP-130 QC WM0130 QCWM-12WM0150 QCWM-14WBWM0180 QCWM-20WBWM0235 QCWM-23WM0300 QCWM-25WBWM0330 QCWM-35WBWM0450 L-17FL-22FL-28FL-30FL-40Aqua an/an/an/aCA-120n/an/aCA-220n/aPro aVertical SteelSta-Rite SRn/an/aPS30-T01n/aPSP42T-T02 /aPS35-T05PS50-T50PS62-T51n/aVertical SteelPS2-S01 PS5-S02ProSourcePSC-35-10 PSC-40-12PSC-48-14PSC-60-20 PSC-80-23 PSC-85-25PSP120-T50 PSP200-T51n/aVertical SP32-T03n/an/aPSP35-T05PSP50-T50PSP62-T51n/aPerma 52n/an/aPSC-119-35PSP220-T52 PSP320-TR50PS85-T52PS119-TR50PSP85-T52 PSP119-TR50PAD-86CO M PO S I TE W ATE R S Y STE M P RE S S U RE TANKSPAD-11913

TWO OF THE MOST COMMONHYDROPNEUMATIC APPLICATIONSTank Sizing InformationThere are three factors to consider when selecting the proper size PentairWellmate tank for your water system:Shallow Well orPressure BoostingSystemWATERQUALITY SYSTEMS The pump delivery rate in gallons/liters per minute (GPM/LPM)5730GLENminimumPARK ROAD,MILWAUKEE,WI 53209 The NORTHrecommendedrunningtime of the pumpP:262.238.4400 WATERPURIFICATION.PENTAIR.COMCUSTOMER CARE: 800.279.9404 tech-support@pentair.com Theminimum (cut-in)and maximum (cut-out) system pressure parametersOncethese factorsare known,the followingcalculationswill determine,mostAllPentairtrademarksand logosare ownedby Pentair,Inc. or itsinaffiliates.All other registered and unregistered trademarks and logos are the property of theircases, the correctmodelto s.*continuously improving our products and services, Pentair reserves the right to change specifications without prior notice.Pentair is an equal opportunity employer.CALCULATING DRAWDOWN1) Pump delivery rate.2) Desired minimum pump running time in minutes(1 minute, 45 seconds 1.75 minutes).3) Multiply line #1 by line #2.This is the minimum drawdown oravailable water volume required.*CALCULATING TANK SIZE4) Minimum system pressure (cut-in).5) Maximum system pressure (cut-out).6) Using table #2, find the drawdownfactor applicable to lines #4 and #5.7) Divide line #3 by line #6 todetermine the minimum totalWellmate volume required.8) Refer to the design data and selectthe Wellmate model with the lowesttotal capacity that is greater thanor equal to line a/barFactorDeep Well SystemGallons/LitersModelEXAMPLE: An application using an 8 GPM pump with a minimum run time of1 minute and a 30-50 PSIG system pressure range;8 GPM x 1minute.30 (factor) 26.7 gallon minimumtank capacity*If the volume of water needed is greater than the amount calculated on line #3,enter that amount on line #3 in place of the calculated volume.TABLE #2 – DRAWDOWN /7.92120/(828)/8.27125/(863)/8.62MINIMUM SYSTEM PRESSURE (CUT-IN) – .12.15.18.21.08.11.15.18.08.11.14.07.11In keeping with current industry standards, drawdown factors are based on Boyle’s law. Actual drawdowns will vary depending upon system variables,including the accuracy and operation of the pressure switch and gauge, actual precharge pressure, and operating temperature of the system.WATER QUALITY SYSTEMS5730 NORTH GLEN PARK ROAD, MILWAUKEE, WI 53209P: 262.238.4400 F: 262.238.4404WELLMATE.COMCUSTOMER CARE: 800.279.9404 tech-support@pentair.com 2015 Pentair Residential Filtration, LLC. All rights reserved.†For a detailed list of where Pentair trademarks are registered, please visit waterpurification.pentair.com.Pentair trademarks and logos are owned by Pentair, Inc. or its affiliates. Third party registered and unregisteredtrademarks and logos are the property of their respective owners.WM308 REV D JE15

NOTE: Maximum external operating temperature 120 F (49 C). Maximum internal operating temperature 100 F (38 C). Minimum operating temperature 40 F (4 C). . Section 8 and NSF/ANSI 372. COMPOSITE WATER

Related Documents:

TANK & EQUIPMENT CO. Stationary Tanks Farm Tanks UL 142 Horizontal & Vertical Tanks API 650 Tanks UL 142 Double Wall Tanks UL 2085 “Protected“ Tanks UL 2245 At/Below Grade Tanks Insulated & Jacketed Storage Tanks Chemical Storage & Blending Tanks P.O. Box 2014 Tyler,

premier tank manufacturers. Double Wall Tanks, Round Bottom Tanks, Frac Tanks, Wier Tanks, Gas Buster Tanks, Mini Tanks and Mixer Tanks are just a few of the standard product lines along with custom tanks for specific configurations. Oil and Gas, Construction and Waste Water

unified approach for seismic design of tanks is highlighted. DOI: 10.1193/1.2428341 INTRODUCTION Liquid-containing tanks are used in water distribution systems and in industries for storing toxic and flammable liquids. These tanks are mainly of two types: ground-supported tanks and elevated tanks. Ground-supported tanks are generally of .

Small, AWWA D-100 constructed welded steel tanks V/S Light gauge welded steel tanks. There are too many manufacturers to name here. Small, AWWA D-103 constructed tanks V/S light gauge, riveted, corrugated steel tanks manufactured by American Tank, or older tanks by B.H. Tank Works/BlueScope Water, and flat panel tanks by Tim

for designing the composite pressure vessels shapes of pressure vessels [27]. During the past two decades, several authors have performed detailed analyses of composite pressure vessels by using the theory of orthotropic plates. Composite pressure vessels tend to fail in their composite pressure vessels parts; the design of these parts is the .

Annex L : API Standard 650 Storage Tank Data Sheet Annex M : Requirements for Tanks Operating at Elevated Temperatures Annex P : Allowable External Loads on Tank Shell Openings Annex S : Austenitic Stainless Steel Storage Tanks Annex V : Design of Storage Tanks for External Pressure Hossein Sadeghi WELDED TANKS FOR OIL STORAGE (Rev. 0) 12 STANDARD INTRODUCTION. Hossein Sadeghi WELDED TANKS FOR .

Types of composite: A) Based on curing mechanism: 1- Chemically activated composite 2- Light activated composite B) Based on size of filler particles: 1 - Conventional composite 2- Small particles composite 3-Micro filled composite 4- Hybrid composite 1- Chemically activated, composite resins: This is two - paste system:

English language and the varieties of dialects/ differences within. The final segment of this course will explore the description and transcription of disordered speech. Required Textbook (Rental): Small, L. H. (2015). Fundamentals of phonetics: A practical guide for students, Fourth edition. Pearson. Audio CDs that accompany the textbook.