Product Data SheetJune 201300813-0200-4485, Rev ECRosemount 3051SF DP Flowmeters Direct or remote mount configurations available Up to 0.80% mass flow rate accuracy MultiVariable capabilities allow for real time fully compensated mass and energy flow Advanced diagnostics predict and prevent abnormal process conditions Installation ready wireless flow solution Ultra for Flow measures percent-of-reading performance over 14:1 flow turndown 10-year stability, 12-year warranty

Rosemount DP FlowJune 2013Rosemount 3051SF DP FlowmetersRosemount 3051SF Flowmeters integrate industry leading transmitters with industryleading primary elements. Capabilities include: Flowmeters are factory configured to meet your application needs (Configuration DataSheet required) MultiVariable capabilities allow scalable flow compensation (Measurement Types 1-7)3051SFA HART 4-20, Wireless, and FOUNDATION fieldbus protocols Ultra for Flow for improved flow performance across wider flow ranges Integral temperature measurement (Option Code T)3051SFC3051SFP Advanced Diagnostics (Option Code DA2) Direct or remote mount configurations availableAdditional InformationSpecifications: page 29Dimensional Drawings: page 50ContentsRosemount 3051SF DP Flowmeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2Rosemount 3051SFA Annubar Flowmeter Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3Rosemount 3051SFC Compact Orifice Flowmeter Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 13Rosemount 3051SFP Integral Orifice Flowmeter Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 213051SF Series Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 293051SF Measurement Type 1-7 Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 403051SF Measurement Type D Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 433051SF Wireless Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 48Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 50Installation and Flowmeter Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Click Here2www.rosemount.com

June 2013Rosemount DP FlowRosemount 3051SFA Annubar Flowmeter Annubar flowmeters reduce permanent pressure loss by creating less blockage in the pipe Ideal for large line size installations when cost, size and weight of the flowmeter are concernsTable 1. Rosemount 3051SFA Annubar Flowmeter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.ModelProduct Description3051SFAAnnubar FlowmeterMeasurementTypeD1-7 Available— UnavailableMeasurement TypeStandard1234DStandardFully Compensated Mass & Energy Flow Calculations – Differential & Static Pressuresw/TemperatureCompensated Flow Calculations – Differential & Static PressuresCompensated Flow Calculations – Differential Pressure & TemperatureCompensated Flow Calculations – Differential PressureDifferential Pressure— — — Process Variables Only (No Flow Calculations) – Differential & Static Pressures withTemperatureProcess Variables Only (No Flow Calculations) – Differential & Static PressuresProcess Variables Only (No Flow Calculations)— —— — — Expanded567Fluid TypeStandardLGSStandard D1-72-in. (50 mm) 21/2-in. (63.5 mm)3-in. (80 mm) 3 /2-in. (89 mm)4-in. (100 mm)5-in. (125 mm)6-in. (150 mm)7-in. (175 mm)8-in. (200 mm)10-in. (250 mm)12-in. (300 mm) 14-in. (350 mm)16-in. (400 mm)18-in. (450 mm)20-in. (500 mm)24-in. (600 mm) LiquidGasSteamLine SizeStandard020025030035040050060070080100120 Standard1 Expanded140160180200240www.rosemount.com3

Rosemount DP FlowJune 2013Table 1. Rosemount 3051SFA Annubar Flowmeter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.30036042048060072030-in. (750 mm)36-in. (900 mm)42-in. (1066 mm)48-in. (1210 mm)60-in. (1520 mm)72-in. (1820 mm) 78-in. (1950 mm)84-in. (2100 mm)90-in. (2250 mm)96-in. (2400 mm) Expanded780840900960Pipe I.D. RangeStandardCDStandardRange C from the Pipe I.D. tableRange D from the Pipe I.D. table Range A from the Pipe I.D. tableRange B from the Pipe I.D. tableRange E from the Pipe I.D. tableNon-standard Pipe I.D. Range or Line Sizes greater than 12-in. (300 mm) ExpandedABEZPipe Material / Mounting Assembly MaterialStandardCS0(1)StandardCarbon steel (A105)316 Stainless Steel No Mounting (Customer Supplied) Chrome-Moly Grade F-11Chrome-Moly Grade F-22Chrome-Moly Grade F-91 D1-7Pak-LokFlanged with opposite side support Flange-LokGear-Drive Flo-TapManual Flo-Tap 316 Stainless Steel ExpandedGNJPiping OrientationStandardHDUStandardHorizontal PipingVertical Piping with Downwards FlowVertical Piping with Upwards FlowAnnubar TypeStandardPF Standard ExpandedLGMSensor MaterialStandardS4Standard www.rosemount.com

June 2013Rosemount DP FlowTable 1. Rosemount 3051SFA Annubar Flowmeter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.ExpandedAlloy C-276 Sensor size 1 — Line sizes 2-in. (50 mm) to 8-in. (200 mm)Sensor size 2 — Line sizes 6-in. (150 mm) to 96-in. (2400 mm)Sensor size 3 — Line sizes greater than 12-in. (300 mm) Compression/Threaded Connection150# RF ANSI300# RF ANSI600# RF ANSIDN PN16 FlangeDN PN40 FlangeDN PN100 Flange A9(2)900# RF ANSI AF(2)1500# RF ANSI AT(2)R1R3R62500# RF ANSI 150# RTJ Flange300# RTJ Flange600# RTJ Flange R9900# RTJ Flange RF(2)1500# RTJ Flange RT(2)2500# RTJ Flange HSensor SizeStandard123Standard Mounting TypeStandardT1A1A3A6D1D3D6Standard Expanded(2)Opposite Side Support or Packing GlandStandard0CDStandardNo opposite side support or packing gland (Required for Pak-Lok and Flange-Lokmodels)Opposite Side Support – Required for Flanged ModelsNPT Threaded Opposite Support Assembly – Extended TipWelded Opposite Support Assembly – Extended Tip ExpandedPacking Gland – Required for Flo-Tap ModelsPacking Gland MaterialRod MaterialPacking Material(3)Stainless Steel Packing Gland / Cage NippleCarbon SteelPTFE K(3)Stainless Steel Packing Gland / Cage NippleStainless SteelPTFE JL(3)Stainless Steel Packing Gland / Cage NippleCarbon SteelGraphite N(3)RStainless Steel Packing Gland / Cage NippleStainless SteelGraphite Alloy C-276 Packing Gland / Cage NippleStainless SteelGraphite D1-7 Isolation Valve for Flo-Tap ModelsStandard0(1)StandardNot Applicable or Customer Suppliedwww.rosemount.com 5

Rosemount DP FlowJune 2013Table 1. Rosemount 3051SFA Annubar Flowmeter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.Expanded1256Gate Valve, Carbon SteelGate Valve, Stainless SteelBall Valve, Carbon SteelBall Valve, Stainless Steel Temperature MeasurementStandardT(4)0(5)StandardIntegral RTD – not available with Flanged model greater than class 600# No Temperature Sensor Remote Thermowell and RTD ExpandedR(4)Transmitter Connection PlatformStandardStandardDirect-mount, Integral 3-valve Manifold– not available with Flanged model greaterthan class 600Direct -mount, 5-valve Manifold – not available with Flanged model greater thanclass 600 Remote-mount NPT Connections (1/2-in. FNPT) 6Direct-mount, High Temperature 5-valve Manifold – not available with Flangedmodel greater than class 600 8Remote-mount SW Connections (1/2-in.) 357 ExpandedDifferential Pressure RangeStandardStandard10 to 25 in H2O (0 to 62.3 mbar) 20 to 250 in H2O (0 to 623 mbar) 30 to 1000 in H2O (0 to 2.5 bar) Static Pressure RangeStandardStandardA(6)NoneDAbsolute 0 to 800 psia (0 to 55.2 bar)— E(7)Absolute 0 to 3626 psia (0 to 250 bar)— JGage -14.2 to 800 psig (-0.979 to 55.2 bar)— Gage -14.2 to 3626 psig (-0.979 to 250 bar)— 4–20 mA with digital signal based on HART protocolFOUNDATION fieldbus protocol (requires PlantWeb housing) — Wireless (Requires wireless options and Wireless Plantweb housing) — (7)KTransmitter OutputStandardAFX(8)6Standardwww.rosemount.com

June 2013Rosemount DP FlowTable 1. Rosemount 3051SFA Annubar Flowmeter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.Transmitter Housing StyleMaterialConduit EntrySizeStandard001A1B1J1K2A2B2E2F2J2MStandard —1/2-14 NPT M20 x 1.5 1/2-14 NPTM20 x 1.5 1 — — —D1-7 — — —None (Customer-supplied electricalconnection)PlantWeb HousingPlantWeb HousingPlantWeb HousingPlantWeb HousingJunction Box HousingJunction Box HousingJunction Box housing with output for remotedisplay and interfaceJunction Box housing with output for remotedisplay and interfaceJunction Box HousingJunction Box housing with output for remotedisplay and minum/2-14 NPTM20 x 1.51/2-14 NPTAluminumM20 x 1.5SST1/2-14 NPTSST1/2-14 NPT 5A(9)Wireless PlantWeb housingAluminum1 — 5J(9)Wireless PlantWeb housingSST1 — 7J(8)(10)Quick Connect (A size Mini, 4-pin maletermination) —G1/2/2-14 NPT/2-14 NPT Expanded1CPlantWeb HousingAluminum 1LPlantWeb HousingSST1G /2 AluminumG1/2 — —D1-72C2GJunction Box HousingJunction Box housing with output for remotedisplay and interfaceAluminumG1/2Transmitter Performance ClassStandard35123(11)Standard3051S MultiVariable SuperModule, Measurement Types 1, 2, 5, and 6Ultra for Flow: 0.8% flow rate accuracy, 14:1 flow turndown, 10-year stability, limited12-year warrantyClassic MV: 1.15% flow rate accuracy, 8:1 flow turndown, 5-yr. stability3051S Single Variable SuperModule, Measurement Types 3, 4, 7, and DUltra: up to 0.95% flow rate accuracy, 8:1 flow turndown, 10-year stability, limited12-year warrantyClassic: up to 1.4% flow rate accuracy, 8:1 flow turndown, 5-year stabilityUltra for Flow: 0.8% flow rate accuracy, 14:1 flow turndown, 10-year stability. limited12-year warranty — — — Wireless Options (Requires option code X and wireless PlantWeb housing)Update Rate, Operating Frequency and ProtocolStandardStandardWAUser Configurable Update RateOperating Frequency and Protocol — — Standard32.4 GHz DSSS, IEC 62591 (WirelessHART)www.rosemount.com7

Rosemount DP FlowJune 2013Table 1. Rosemount 3051SFA Annubar Flowmeter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.Omnidirectional Wireless AntennaStandardWKWMExternal AntennaExtended Range, External Antenna — —High-Gain, Remote Antenna —Adapter for Black Power Module (I.S. Power Module Sold Separately) — ExpandedWNSmartPower Standard1(12) Other Options (Include with selected model number)Pressure TestingExpandedP1(13)Hydrostatic Testing with CertificateExtended Hydrostatic TestingPX(13)Special CleaningExpandedP2Cleaning for Special ServicesPACleaning per ASTM G93 level D (section 11.4)Material Testing D1-7 ExpandedV1Dye Penetrant ExamMaterial ExaminationExpandedV2Radiographic ExaminationFlow CalibrationExpandedW1Flow Calibration (Average K)WZSpecial CalibrationSpecial InspectionStandardQC1QC7Surface FinishStandardVisual & Dimensional Inspection with CertificateInspection & Performance Certificate Standard StandardRLSurface finish for Low Pipe Reynolds Number in Gas & SteamRHSurface finish for High Pipe Reynolds Number in LiquidMaterial Traceability CertificationStandard Standard ANSI / ASME B31.1 ANSI / ASME B31.3 Material Traceability Certificate per EN 10204:2004 3.1Q8(14)Code Conformance ExpandedJ2(15)(15)J38www.rosemount.com

June 2013Rosemount DP FlowTable 1. Rosemount 3051SFA Annubar Flowmeter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.Material ConformanceExpandedNACE MR-0175 / ISO 15156J5(16)Country Certification StandardJ6StandardEuropean Pressure Directive (PED) ExpandedJ1Canadian RegistrationInstalled in Flanged Pipe Spool SectionExpandedH3150# Flanged Connection with Rosemount Standard Length and ScheduleH4300# Flanged Connection with Rosemount Standard Length and ScheduleH5600# Flanged Connection with Rosemount Standard Length and ScheduleInstrument Connections for Remote Mount OptionStandardG2G6StandardNeedle Valves, Stainless SteelOS&Y Gate Valve, Stainless Steel Needle Valves, Carbon SteelNeedle Valves, Alloy C-276OS&Y Gate Valve, Carbon SteelOS&Y Gate Valve, Alloy C-276 ExpandedG1G3G5G7Special ShipmentStandardStandardY1Mounting Hardware Shipped SeparatelySpecial Dimensions D1-7 ExpandedVMVariable MountingVTVariable TipVSVariable length Spool SectionTransmitter Calibration CertificationStandardStandardQ4Calibration Certificate for TransmitterQPCalibration Certificate & Tamper Evident SealQuality Certification For Safety StandardQS(19)(25)StandardPrior-use Certificate of FMEDA dataQT(18)(19)(25) Safety certified to IEC 61508 with certificate of FMEDA dataProduct Certifications — — — StandardE1I1IAN1NDK1 StandardATEX FlameproofATEX Intrinsic SafetyATEX FISCO Intrinsic Safety; for FOUNDATION fieldbus protocol onlyATEX Type nATEX DustATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E1, I1, N1, and ND)www.rosemount.com 9

Rosemount DP FlowJune 2013Table 1. Rosemount 3051SFA Annubar Flowmeter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.E4E5I5K5E6(17)TIIS FlameproofFM Explosion-proof, Dust Ignition-proofFM Intrinsically Safe, Division 2FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination ofE5 and I5) CSA Explosion-proof, Dust Ignition-proof, Division 2 Standard StandardI6CSA Intrinsically SafeCSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combinationK6(17)of E6 and I6)E7IECEx Flameproof, Dust Ignition-proofI7IECEx Intrinsic SafetyIECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, Type n (combination of E7, I7,K7and N7)E3China FlameproofI3China Intrinsic SafetyATEX and CSA Explosion-proof, Intrinsically Safe, Division 2 (combination of E1, I1,KA(17)E6, and I6)FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2KB(17)(combination of E5, E6, I5, and I6)FM and ATEX Explosion-proof, Intrinsically Safe, Division 2 (combination of E5, E1, I5,KCand I1)FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of E5, I5, E6, I6,KD(17)E1, and I1)Shipboard ApprovalsStandard Standard Inert Sensor Fill FluidGraphite-Filled (PTFE) O-ringInert Sensor Fill Fluid and Graphite-Filled (PTFE) O-ring PlantWeb LCD display (Requires PlantWeb housing) Remote mount LCD display and interface, PlantWeb housing, no cable; SST bracket D1-7SBSAmerican Bureau of ShippingSensor Fill Fluid and O-ring OptionsStandardL1L2LA Standard Digital Display(18)StandardM5M7(19)(20)(21)StandardRemote mount LCD display and interface, PlantWeb housing, 50 ft. (15 m) cable; SSTM8(19)(20)bracketRemotemount LCD display and interface, PlantWeb housing, 100 ft. (31 m) cable;M9(19)(20)SST bracketTransient ProtectionStandardTransient terminal blockT1Manifold for Remote Mount OptionStandard10 Standard(22)F2F6 Standard3-Valve Manifold, Stainless Steel5-Valve Manifold, Stainless Steel www.rosemount.com

June 2013Rosemount DP FlowTable 1. Rosemount 3051SFA Annubar Flowmeter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.ExpandedF13-Valve Manifold, Carbon SteelF33-Valve Manifold, Alloy C-276F55-Valve Manifold, Carbon SteelF75-Valve Manifold, Alloy C-276PlantWeb Control Functionality —StandardStandardA01FOUNDATION fieldbus Advanced Control Function Block SuitePlantWeb Diagnostic FunctionalityStandard StandardD01(23)FOUNDATION fieldbus Diagnostics Suite — Advanced HART Diagnostic Suite — DA2PlantWeb Enhanced Measurement FunctionalityStandardStandardFOUNDATION fieldbus Fully Compensated Mass Flow BlockH01(24)Cold Temperature —Standard StandardBRR — Hardware Adjustments (zero, span, alarm, security) — External Ground Screw AssemblyHardware Adjustments (zero, span, alarm, security) & External Ground ScrewAssembly — -60 F (-51 C) Cold Temperature Start-up(19)(25)Alarm LimitStandardStandardC4NAMUR Alarm & Saturation Levels, High AlarmC5NAMUR Alarm & Saturation Levels, Low AlarmC6Custom Alarm & Saturation Levels, High AlarmC7Custom Alarm & Saturation Levels, Low AlarmC8Low Alarm (Standard Rosemount Alarm & Saturation Levels)Hardware Adjustments and Ground ScrewStandardD1(19)(25)(26)D4DA(19)(25)(26) Standard Conduit PlugStandardStandardDO316 SST Conduit Plug (standard for all 3051SF Models)Conduit Electrical ConnectorStandard(27)GE Standard M12, 4-pin, Male Connector (eurofast )(27) A size Mini, 4-pin, Male Connector (minifast )GMTypical Model Number: 3051SFA D L 060 D C H P S2 T1 0 0 0 3 2A A 1A 3(1) Provide the “A” dimension for Flanged, Flange-Lok, and Threaded Flo-Tap models. Provide the “B” dimension for Flange Flo-Tap models.(2) Available in remote mount applications only.(3) The cage nipple is constructed of 304SST.(4) Temperature Measurement Option code T or R is required for Measurement Type codes 1, 3, 5, and 7.(5) Required for Measurement Type codes 2, 4, 6, and D.www.rosemount.com11

Rosemount DP FlowJune 2013(6) Required for Measurement Type codes 3, 4, 7, and D.(7) For Measurement Type 1, 2, 5, and 6 with DP range 1, absolute limits are 0.5 to 2000 psi (0,03 to 137,9 bar) and gage limits are -14.2 to 2000 psig (-0,98 to 137,9 bar).(8) Available approvals are FM Intrinsically Safe, Division 2 (option code I5), CSA Intrinsically Safe (option code I6), ATEX Intrinsic Safety (option code I1), and IECEx IntrinsicSafety (option code I7).(9) Only available with output code X.(10) Available with output code A only.(11) Only available with differential pressure ranges 2 and 3, and silicone fill fluid.(12) Long-life Power Module must be shipped separately, order Part No. 00753-9220-0001.(13) Applies to assembled flowmeter only, mounting not tested.(14) Instrument Connections for Remote Mount Options and Isolation Valves for Flo-tap Models are not included in the Material Traceability Certification.(15) Not available with Transmitter Connection Platform 6.(16) Materials of Construction comply with metallurgical requirements within NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits applyto certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.(17) Not available with M20 or G ½ conduit entry size.(18) Not available with housing code 7J.(19) Not available with output code X.(20) Not available with output code F, option code DA2, or option code QT.(21) See the 3051S Reference Manual (document number 00809-0100-4801) for cable requirements. Contact an Emerson Process Management representative for additionalinformation.(22) Not available with Housing code 5A, 5J, or 7J. External ground screw assembly (option code D4) is included with the T1 option. The T1 option is not needed with FISCOProduct Certifications, transient protection is included with the FISCO Product Certification code IA.(23) Includes Hardware Adjustments (option code D1) as standard. Not available with output code X.(24) Requires Rosemount Engineering Assistant version 5.5.1 to configure.(25) Not available with Output Protocol code F.(26) Not available with housing style codes 2E, 2F, 2G, 2M, 5A, 5J, or 7J.(27) Not available with Housing code 5A, 5J, or 7J. Available with Intrinsically Safe approvals only. For FM Intrinsically Safe, Division 2 (option code I5) or FM FISCO IntrinsicallySafe (option code IE), install in accordance with Rosemount drawing 03151-1009 to maintain outdoor rating (NEMA 4X and IP66).12www.rosemount.com

June 2013Rosemount DP FlowRosemount 3051SFC Compact Orifice Flowmeter Compact Conditioning flowmeters reduce straight piping requirements to 2D upstream and 2D downstreamfrom a flow disturbance Simple installation of Compact flowmeters between any existing raised-face flangesTable 2. Rosemount 3051SFC Compact Orifice Flowmeter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.ModelProduct Description3051SFCCompact Orifice FlowmeterMeasurementTypeD1-7 Available— UnavailableTransmitter Feature Board Measurement TypeStandardStandard1234DFully Compensated Mass & Energy Flow Calculations – Differential & Static Pressures w/TemperatureCompensated Flow Calculations – Differential & Static PressuresCompensated Flow Calculations – Differential Pressure & TemperatureCompensated Flow Calculations – Differential PressureDifferential Pressure— — — Process Variables Only (No Flow Calculations) – Differential & Static Pressures withTemperatureProcess Variables Only (No Flow Calculations) – Differential & Static PressuresProcess Variables Only (No Flow Calculations) — —— — — Annubar Averaging Pilot Tube Conditioning Orifice PlateOrifice Plate 316 SST 1 1-in. (25 mm) 1 /2-in. (40 mm)2-in. (50 mm)3-in. (80 mm)4-in. (100 mm)6-in. (150 mm)8-in. (200 mm) 100(2)(3)10-in. (250 mm)(2) (3) (2)(3)12-in. (300 mm)(2) (3) Expanded567Primary Element TechnologyStandardStandardACP Material TypeStandardStandardS Line 080120/2-in. (15 mm)1www.rosemount.com13

Rosemount DP FlowJune 2013Table 2. Rosemount 3051SFC Compact Orifice Flowmeter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.Primary Element TypeStandardN000N040N065(4)StandardAnnubar Sensor Size 10.40 Beta Ratio ( )0.65 Beta Ratio ( ) — Temperature MeasurementStandardTStandard(6)Integral RTD(5)No Temperature Sensor Remote Thermowell and RTD D1-7 0ExpandedR(6)Transmitter Connection , NPT Connections Differential Pressure RangeStandardStandard10 to 25 inH2O (0 to 62.3 mbar) 20 to 250 inH2O (0 to 623 mbar) 30 to 1000 inH2O (0 to 2.5 bar) — — — — 4–20 mA with digital signal based on HART protocolFOUNDATION fieldbus protocol — Wireless — —/2-14 NPTM20 x 1.5 1/2-14 NPTM20 x 1.5 1 — —Static Pressure RangeStandardA(7)DE(8)J(8)KStandardNoneAbsolute 0 to 800 psia (0 to 55.2 bar)Absolute 0 to 3626 psia (0 to 250 bar)Gage -14.2 to 800 psig (-0.979 to 55.2 bar)Gage -14.2 to 3626 psig (-0.979 to 250 bar)Transmitter OutputStandardA(9)FX(10)(11)StandardTransmitter Housing StyleMaterialConduit EntrySizeStandard001A1B1J1K2A2B14StandardNone (Customer-supplied electrical connection)PlantWeb HousingPlantWeb HousingPlantWeb HousingPlantWeb HousingJunction Box HousingJunction Box 4 NPTM20 x 1.5www.rosemount.com

June 2013Rosemount DP FlowTable 2. Rosemount 3051SFC Compact Orifice Flowmeter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.MaterialConduit ndardJunction Box housing with output for remote displayand interfaceJunction Box housing with output for remote displayand interfaceJunction Box HousingJunction Box housing with output for remote displayand interfaceWireless PlantWeb housingWireless PlantWeb housing — — — — Aluminum1/2-14 NPTAluminumM20 x 1.5SST1SST1/2-14 NPTAluminum1/2-14 NPT — SST1/2-14 NPT — — Aluminum G1/2SSTG1/2 Aluminum G1/2 — —D1-7 — — — /2-14 NPTQuick Connect (A size Mini, 4-pin male termination) Expanded1CPlantWeb Housing1LPlantWeb Housing2CJunction Box HousingJunction Box housing with output for remote displayand interface2GAluminum G1/2Transmitter Performance ClassStandardStandard3051S MultiVariable SuperModule, Measurement Types 1, 2, 5, and 6Ultra for Flow: 0.75% flow rate accuracy, 14:1 flow turndown, 10-yr stability, limited312-yr warranty5Classic MV: 1.10% flow rate accuracy, 8:1 flow turndown, 5-yr stability3051S Single Variable SuperModule, Measurement Types 3, 4, 7, and DUltra: 0.90% flow rate accuracy, 8:1 flow turndown, 10-yr stability, limited 12-yr1warranty2Classic: 1.40% flow rate accuracy, 8:1 flow turndown, 5-yr stabilityUltra for Flow: 0.75% flow rate accuracy, 14:1 flow turndown, 10-yr stability, limited3(14)12-yr warranty Wireless Options (Requires option code X and wireless PlantWeb housing)Update Rate, Operating Frequency, and ProtocolStandardStandard — —External AntennaExtended Range, External Antenna — —High-Gain, Remote Antenna —Adapter for Black Power Module (I.S. Power Module Sold Separately) —WAUser Configurable Update RateOperating Frequency and ProtocolStandardStandard32.4 GHz DSSS, IEC 62591 (WirelessHART)Omnidirectional Wireless AntennaStandardWKWM Standard ExpandedWNSmartPower Standard1(15)Standardwww.rosemount.com 15

Rosemount DP FlowJune 2013Table 2. Rosemount 3051SFC Compact Orifice Flowmeter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.Other Options (Include with selected model number)Installation AccessoriesStandardACDGHJStandardANSI Alignment Ring (150#) (Only required for 10-in. (250 mm) and 12-in. (300mm)line sizes)ANSI Alignment Ring (300#) (Only required for 10-in. (250 mm) and 12-in. (300mm)line sizes)ANSI Alignment Ring (600#) (Only required for 10-in. (250 mm) and 12-in. (300mm)line sizes)DIN Alignment Ring (PN 16)DIN Alignment Ring (PN 40)DIN Alignment Ring (PN 100) ExpandedBJIS Alignment Ring (10K)RJIS Alignment Ring (20K)SJIS Alignment Ring (40K)Remote AdaptersStandardStandard1EFlange adapters 316 SST ( /2-in. NPT)High Temperature Applications ExpandedTGraphite Valve Packing (Tmax 850 F)Flow CalibrationExpandedWC(16)WD(17) (18)Flow Calibration, 3 Pt, Conditioning Option C (All Pipe Schedules)Flow Calibration, 10 Pt, Conditioning Option C (All Schedules), Annubar Option A(Schedule 40)Pressure TestingExpandedP1Hydrostatic Testing with CertificateSpecial Cleaning D1-7 ExpandedCleaning for Special ProcessesP2(19)PACleaning per ASTM G93 Level D (section 11.4)Special InspectionStandardStandardQC1Visual & Dimensional Inspection with CertificateQC7Inspection & Performance CertificateTransmitter Calibration Certification StandardStandardQ4Calibration Data Certificate for TransmitterQPCalibration Certificate and Tamper Evident SealQuality Certification for Safety StandardQS(20)(21)QT16(20)(21)(24) StandardPrior-use certificate of FMEDA data — Safety Certified to IEC 61508 with certificate of FMEDA data — www.rosemount.com

June 2013Rosemount DP FlowTable 2. Rosemount 3051SFC Compact Orifice Flowmeter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.Material Traceability CertificationsStandardStandardQ8Material Traceability Certification per EN 10204:2004 3.1Code Conformance ExpandedJ2ANSI / ASME B31.1J3ANSI / ASME B31.3J4ANSI / ASME B31.8Material ConformanceExpandedNACE MR-0175 / ISO 15156J5(22)Country CertificationExpandedJ1Canadian RegistrationProduct K6(23)E7I7K7E3I3StandardATEX FlameproofATEX Intrinsic SafetyATEX FISCO Intrinsic Safety; for FOUNDATION fieldbus protocol onlyATEX Type nATEX DustATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E1, I1, N1, and ND)TIIS FlameproofFM Explosion-proof, Dust Ignition-proofFM Intrinsically Safe, Division 2FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination ofE5 and I5)CSA Explosion-proof, Dust Ignition-proof, Division 2CSA Intrinsically SafeCSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination ofE6 and I6)IECEx Flameproof, Dust Ignition-proofIECEx Intrin

3 June 2013 Rosemount DP Flow www.rosemount.com Rosemount 3051SFA Annubar Flowmeter Annubar flowmeters reduce permanent pressure loss by creating less blockage in the pipe Ideal for large line size installations when cost, size and weight of the flowmeter are concerns Table 1. Rosemount 3051SFA Annubar Flowmeter Ordering

Related Documents:

Rosemount 3051S/3051/2051/3095 Rosemount 1151 D C D Rosemount 3051S/3051/2051/3095 Rosemount 1151 Februari 2019. 8 Snelstartgids 2.6 Montagerichting inline-druktransmitter De drukpoort aan de lage kant (ref. atmosferische druk) op de inline-verschildruktransmitter bevindt zich in de hals van de transmitter, achter

Rosemount 3051S 305 A11 N/A 306 A11 N/A 304 A12 N/A Rosemount 3051/2051 305 N/A S5 306 N/A S5 304 N/A S6 Rosemount 2088 305 N/A N/A 306 N/A S5 304 N/A N/A Rosemount 4088 305 A11 N/A 306 A11 N/A 304 A12 N/A. Procedure. 1. Specify a completed Rosemount transmitter model number by referencing the applica

Rosemount 3051S 305 A11 N/A 306 A11 N/A 304 A12 N/A Rosemount 3051/2051 305 N/A S5 306 N/A S5 304 N/A S6 Rosemount 2088 305 N/A N/A 306 N/A S5 304 N/A N/A Rosemount 4088 305 A11 N/A 306 A11 N/A 304 A12 N/A. Procedure. 1. Specify a completed Rosemount transmitter model number by referencing the applica

A11(12)(13) Assemble to Rosemount 305 Integral Manifold A12(12) Assemble to Rosemount 304 or AMF manifold with 316 SST traditional flange C11(12) Assemble to Rosemount 405C or 405P Primary Element D11(12) Assemble to Rosemount 1195 Integral Orifice and 305 Manifold EA2(12) Assemble to Rosemount 485 or 405A Annubar

A11(5) Assemble to Rosemount 305 Manifold Assemble to Rosemount 306 Manifold A12(5) Assemble to Rosemount 304 or AMF Manifold with SST Traditional Flange N/A B11(5)(6) Assemble to One Rosemount 1199 Remote Diaphragm Seal with SST transmitter flange Assemble to One Rosemount 1199 Remote Diaphragm

Rosemount 644 Smart Temperature Transmitters may be protected by one or more U.S. Patents pending. Other foreign patents pending. Rosemount 644 Hardware Revision . Rosemount 644 Head Transmitter. Rosemount 644. Rosemount 644. Reference Manual 00809-0100-4728, Rev JA. January 2004

Rosemount 3051 www.rosemount.com 00825-0100-4797G Quick Installation Guide 00825-0100-4797, Rev EA June 2010 Rosemount 3051 Pressure Transmitter with Profibus-PA Rosemount 3051CF Series Flowmeter Transmitter with Profibus-PA Start End Step 1: Mount the Transmitter Step 2: Consider Housing Rotation Step 3: Set the Jumpers

of BEC is defined in terms of divisions, groups, subgroups and basic headings of SITC , Rev. 3. The categories of BEC are a rearrangement and aggregation of the basic headings of SITC, Rev. 3; reflecting the end -uses of the commodities covered by each basic heading. Each SITC, Rev. 3 basic heading is allocated entirely to one BEC category .