CONTROLLING SERIAL TEMPERATURE CONTROLLERS FROM

2y ago
4 Views
2 Downloads
1.51 MB
8 Pages
Last View : 1m ago
Last Download : 3m ago
Upload by : Adele Mcdaniel
Transcription

is connected to the receiver of the other device.GPIB to MODBUS CONTROLLER SOLUTIONICS has three GPIB-to-Modbus Controller products that simplifythe Modbus temperature control program by generating the ModbusRTU Packets and automatically handling the response packets. Theseproducts are the Model 4899A which is a stand-alone small boxproduct for bench top use, and two board products, Models 4809Aand 4819A, which are designed to be mounted inside the temperaturechamber. All three interfaces are IEEE-488.2 compatible.RS-422SW23RS-422 differential signals have better common mode noise rejection and can be used over longer distances than can RS-232 signals.RS-422 connections have two pairs of wires to connect. RS-422signal names are confusing as they vary from full names like SendData to abbreviations such as TX and RX. They often end in (A),(B) or and -. (A signals are positive true and normally mate to signals). Figure 6 shows how the 4814 is connected to a Watlow942 Controller with RS-422 signals. The dotted ground wire isoptional and is not needed for the serial signals. Use a cable withtwo twisted pairs of wires. Use one pair of wires for each pair ofsignals. For long runs, use a shielded cable and connect the shieldto ground at one end of the cable.02/14

4814 Switch Setting ReferenceThe 4814 has three on-card rocker switches that must be set to match the serial device which in this case is the temperature controller.Figure 5 on the prior page shows the switch locations and reference designations. Logic 1 is on, logic 0 is off. Use the silkscreenlegends for rocker identiļ¬cation.Switch 1 - Character Format SwitchSets serial character data bits, stop bits and parity. Also forces DTR and RTS lines on. Normally set for 8 data bits, 1 stop bit and noparity. Some temperature controller applications set the 4814 to 7 data bits, odd parity and 1 stop bit.12345678The Character Format Switch rocker functions are self explanatory. Switchis shown set for 8 data bits, 1 stop bit and no parity. Tenny factory settingsare 1200 baud, 7 data bits, 1 stop bit and odd parity.10XONFDTR8BITSECHOPARITYEVENFRTSECHO causes the received data to be echoed back to the serial device. SetEcho off for use with a Temperature Controller.2STPSwitch 2 - Baud Rate SwitchSets serial baud rate, 4814 response terminator and inhibits SRQ generation. The FTP rocker is for factory test and must be set off.Baud Rate QINHFTPSwitch 3 - GPIB Address 1111Baud Rate57.6K5075110134.51503006001200240048009600 Factory Setting1920038400Sets GPIB Bus Address, selects the active serial port and enables the ANSI Protocol Option. TM is a test mode rocker that echos serialdata back to the serial device. Logic 1 is away from the edge of the PC board.12345678GPIB Address is set by rockers 5 to 1. From left to right, bit weightsare 16, 8, 4, 2, and 1. Rocker 5 is the MSB. Switch is shown at address 4.1054321422OPT422 rocker must be Off to use the RS-232 port and On to use the RS422 port.TMOPT rocker is Off for normal serial data but must be On to enable theANSI Protocol Option used with the Tenny and Watlow TemperatureControllers.402/14

Figure 62322212019Signal GroundRR TT J4Shield 1TxD 2Rxd 3RTS 4CTS 5DSR 6Gnd 7DCD 8DTR 20Figure 7J1GPIB1W2W31J2J34814 to Watlow 942 RS-422 ConnectionsJ3256 51211RS-232 connections are recommended with the Versatenn and theWatlow 942 controllers as they can be successfully used at rates of9600 baud or faster. RS-422 connections with these controllers havenot been reliable above 1200 baud. Figure 7 shows the RS-232 toVersatenn connections.4814 -W1W4126485937W5ShieldSendData SendD

Watlow 942, 988 and F4 series controllers. BACKGROUND Most temperature controllers used in temperature and environmental chambers have the ability to be remotely controlled over a RS-232 and RS-422 or RS-485 serial link. In many manufacturing and test applicati

Related Documents:

Temperature Controllers PHY3128 (Electronics for Measurement Systems) Temperature Controllers 1 Temperature Controllers Introduction This handout examines the performance of several systems for controlling the temperature of an oven by adjusting the heater power - a much harder task than it might first appear.

1 TXD O (1) Serial port (Transmitted Data) 2 DTR_N O (1) Serial port (Data Terminal Ready) 3 RTS_N O (1) Serial port (Request To Send) 4 VDD_325 P RS232 VDD. The power pins for the serial port signals. When the serial port is 3.3V, this should be 3.3V. When the serial port is 2.5V, this should be 2.5V. 5 RXD I (2) Serial port (Received Data)

Procedures Programming Manual, publication 1756-PM001. The term Logix5000 controller refers to any controller that is based on the Logix5000 operating system, such as: CompactLogix controllers ControlLogix controllers DriveLogix controllers FlexLogix controllers SoftLogix5800 controllers

Common Procedures Programming Manual, publication 1756-PM001. The term Logix5000 controller refers to any controller that is based on the Logix5000 operating system, such as: CompactLogix controllers ControlLogix controllers DriveLogix controllers FlexLogix controllers SoftLogix5800 controllers

Logix5000 Controllers Common Procedures Programming Manual, publication 1756-PM001. The term Logix5000 controller refers to any controller that is based on the Logix5000 operating system, such as: CompactLogix and Compact GuardLogix controllers ControlLogix and GuardLogix controllers DriveLogix controllers. FlexLogix controllers.

Wired Controllers - Net2 plus 6-7 Wireless Controllers - Net2 nano 8-9 Wireless Controllers - Net2 PaxLock 10-11 Net2 Software 12-13 Video Intercom - Net2 Entry 14-15 Paxton Readers 16-17. Paxton Catalog. Wired Controllers - Net2 plus 18 Wireless Controllers - Net2 nano 19 Wireless Controllers - Net2

www.LearnSAP.com Controlling - - 3 Step - 1 Setup Controlling Area - Basic Data The controlling area is the central organizational unit within the CO module. There are four rules concerning the controlling area that you must know. If you utilize CO you must configure at least one controlling area.

Tank plumb reading within API 650 tolerances easily achievable Less involvement of high capacity cranes Scaffolding costs held at minimum Hydraulic jacks connected to load by a failsafe friction grip system , saves tank if pump/ hose fails Tanks erected with jacks , less susceptible to collapse due to high winds Wind girder/roof in place, as the top shell is erected first .