NORDSTROM POLY-GAS VALVES POLYETHYLENE VALVES

2y ago
28 Views
4 Downloads
523.92 KB
6 Pages
Last View : 3d ago
Last Download : 3m ago
Upload by : Braxton Mach
Transcription

NORDSTROM POLY-GAS VALVESPOLYETHYLENE VALVESFOR NATURAL GAS

Flow ControlNordstrom ValvesWhy use Flowserve Nordstrom Poly-Gas Valves?Nordstrom Poly-Gas valves are everything you’d expect from the company thatinvented polyethylene valves.More than two million Nordstrom Poly-Gas valves have been sold since1976 and are in use throughout the world. Here’s why: Rugged and reliable NordstromPoly-Gas valves are thestrongest part of a polyethylenepiping system. Bubble-tight shutoff fromdual elastomeric seats. Fused body shell removes leakpaths to atmosphere. High-grade polymeric materialseliminate corrosion. Multiple elastomeric stem seals. No metal internal parts. Smooth bore gives excellent flowcharacteristics in both full andreduced port designs.2" – 12" design½" – 2"Polyvalve II (C-style) designNote: Has high-strength stainless steel stem. 2" C-style is reduced bore only.NORDSTROM POLY-GAS VALVES FOR NATURAL GAS

Flow ControlNordstrom ValvesWhy use polyethylene valves?EXPENSIVEWELDED JOINTSBRITTLEIRON PIPEINTERNAL SCALINGDAMAGE FROMFROST HEAVE ANDGROUND MOVEMENTEXTERNALCORROSIONLEAKING FLANGESAll Metal System (Welded or Bolted): Subject to external corrosion, internal scaling and damage from ground movement. Seismic activity, frost heave or settling can rupture brittle iron pipe.EACH VALVENEEDS CATHODICPROTECTIONPOLYETHYLENE TOMETAL ADAPTORSJOINT LEAKSDAMAGE FROMFROST HEAVE ANDGROUND MOVEMENTPolyethylene Pipe-to-Metal Valve Systems: Subject to the inherent weakness of combining incompatible materials. May suffer damage from ground movement. Leaks may occur where the polyethylene and metal meet. Requires cathodic protection for each metal valve to prevent corrosion.FUSIONAll-Polyethylene Systems: Intrinsically safe. Pipe is fused to the valves so there are no leak points. No chance of corrosion. Little chance of rupture because polyethylene systems flex when the ground moves.NORDSTROM POLY-GAS VALVES FOR NATURAL GASFUSION

Flow ControlNordstrom ValvesPoly-Gas Valve AvailabilityMATERIALSMaterials of ConstructionBody Materials Chart½" through 2"Polyvalve II (C-style)2" through leneSeat RetainerAcetalPolypropyleneSeatBuna NBuna NStemStainless SteelAcetalItemStem SealBuna NBuna NGround Water SealNeopreneNeopreneWrench AdapterAcetalPolypropylene*Adapter ScrewStainless SteelAdapter nsityTR-418 (D6500)YellowPE 2406MediumCP ChemTR-480(D6800)BlackPE 3408HighCP ChemH-516(D8100)BlackPE 3408HighFina3407BBlackPE 3408HighResinSupplierMaterial DesignationCP ChemNote: On 8" full bore and 12" full bore only the main body section isavailable in TR-480 material but different pipe ends are fusedon to suit customer’s requirements.*Note: 12" has gear box and cast iron 2" square nut adaptor.8" will have a choice of either gearing or wrench.2" C-style is Reduced Bore only.CODES AND STANDARDS Flowserve Nordstrom Poly-Gas valves meet orexceed the requirements of:U.S. Department of Transportation 49CFR, Part 192ANSI B16.40ASTM D-2513 In addition, as required by customers, certainsizes and materials of valves meet or exceed therequirements of CSA B137.0 and B137.4 Nordstrom Poly-Gas valves have successfullypassed 10,000-hour tests to ISO 4437 Flowserve Nordstrom Valves is an ISO 9001certified company.APPLICATIONSFor use in: Natural gas distribution Natural gas gathering Landfill gas (methane) Hydrocarbon fuel gases Hydrogen Air Other inert gases (helium, argon, neon)12" Poly-Gas valve installationNORDSTROM POLY-GAS VALVES FOR NATURAL GAS

Flow ControlNordstrom ValvesPoly-Gas Valve AvailabilityPoly-Gas Valve Availability Chart (Ball Valves for Natural Gas)Size (Inches) Size (Metric) Body 53Vent PipeSize (IPS)Min MaxBorefull †full †reduced †reduced †fullreduced l½"¾"½"¾"¾"1"1"1¼"1"1¼"End Config.**BF* or 02407004001800900365013507000 ANSI Valve 12.512.6* Butt Fusion** Socket Fusion† Polyvalve II (C-Style) Valves fullfullAvailable SDRs9.39.3, 10, 119.3, 11, 12.59.3, 11, 12.59.3, 119.3, 119.3, 11, 13.59.3, 11, 13.59.3, 11, 13.59.3, 11, 13.59.3, 11, 13.59.3, 11, 13.511, 13.59.3, 11, 13.511, 13.5 812Equiv. Feetof .6Note: CV in US gal/min @ 1 psi PKv in litres/min @ 1 bar PDimension DataSize BoreA½full10.0¾full10.01 reduced 10.01¼ reduced 10.0full14.72reduced 13.0full15.03reduced 12.8full20.04reduced 15.0full25.06reduced 20.0full69.58reduced 978526331946773542CDE4.8 2.8 0.504.8 2.8 0.754.8 2.8 0.904.8 2.8 0.909.1 3.6 1.856.5 3.7 1.3511.4 4.0 2.509.1 3.6 1.8515.0 4.5 3.6211.4 4.0 2.5018.6 5.0 5.2015.0 5.3 3.6219.9 24.0 6.6618.6 5.0 4.78Gear Operated69.5 14.3 22.1 25.7 6.6683.8 17.5 27.7 30.0 9.91Metric Valve 0-110reduced150-160full& 180125-160 3330381325508381B8686868616411520316426420361*635 320 472 127 132.1 168*130*17.2177.810.444.519.3508 263 381 133 91.91765 318 504 610 169.2 196508 320 472 127 121.4Gear Operated1765 363 561 653 169.2 1962129 443 704 762 122 71 12.7122 71 19.1122 71 22.9122 71 22.9231 91 47.0 69*165 94 34.3290 102 63.5231 91 47.0381 114 91.9 127*290 102 63.595*17860.8138.3*Optional vent holes. Contact factory for other vent options.Note: Valves are generally available in these metric sizes and may be available in other metric dimensions. Due to wall thickness considerations, all SDRs in some sizes may not beavailable. Contact your Flowserve representative for exact availability.NORDSTROM POLY-GAS VALVES FOR NATURAL GAS

Flow ControlNordstrom ValvesHow to OrderPlease provide the following information when you order: Valve size Valve body material Bore type (full or reduced) Standard Dimension Ratio (SDR) number End configuration (butt fusion or socket fusion) Special service conditionsFlowserve Nordstrom Poly-Gas ValveFigure Number SystemThe Poly-Gas valve figure number system utilizes a five digit numberwhich describes the valves as shown below.Identifies the valve as a Nordstrom Poly-Gas valvefor natural gas service.Material designation:0. Uponor UAC 2000 (Size 12" ends only)1. No Longer Used2. No Longer Used3. No Longer Used4. CP Chem TR-418 (D6500)5. CP Chem H-516 (D8100)6. CP Chem TR-480 (D6800)7. Not Used8. FINA 3407BFrom the ½" ball valve to the industry’s first 12-inch polyethylene ballvalve, Nordstrom Poly-Gas valves are available in the widest rangeof sizes on the market today. They are shipped in cartons to shieldthem from ultraviolet light and to protect the valve ends from damage.Defines flow passage (full or reduced) and end connection (ANSI or Metric dimension):1. Full opening - American iron pipe size ends2. Reduced opening - American iron pipe size ends3. Full opening - Metric ends4. Reduced opening - Metric ends5. Full opening - CTS ends or other special features6. Reduced opening - CTS ends or special featureendsStandard Dimensions Ratio (SDR)(00 other special feature1)8XXXX1Special feature ends include integral socket ends, stub end SDR, etc.Authorized DistributorsFor detailed information on these and other Nordstrom products, call your customer servicerepresentative for the name and number of the nearest authorized Nordstrom distributor.Flowserve Corporation1-800-225-6989Email: nmkt@flowserve.comor visit www.flowserve.comFlowserve Nordstrom Valves1511 Jefferson StreetSulphur Springs, Texas 75482USAUnited StatesTelephone: 903-885-4691 or 4693FAX: 903-439-3411Latin AmericaTelephone: 903-439-3407FAX: 903-439-3411Other CountriesTelephone: 903-885-4692FAX: 903-439-3404Flowserve Corporation has established industry leadership in the design and manufacture of its products. When properly selected, this Flowserve product is designed to perform its intended function safelyduring its useful life. However, the purchaser or user of Flowserve products should be aware that Flowserve products might be used in numerous applications under a wide variety of industrial serviceconditions. Although Flowserve can (and often does) provide general guidelines, it cannot provide specific data and warnings for all possible applications. The purchaser/user must therefore assume the ultimateresponsibility for the proper sizing and selection, installation, operation, and maintenance of Flowserve products. The purchaser/user should read and understand the Installation Operation Maintenance (IOM)instructions included with the product, and train its employees and contractors in the safe use of Flowserve products in connection with the specific application.While the information and specifications contained in this literature are believed to be accurate, they are supplied for informative purposes only and should not be considered certified or as a guarantee ofsatisfactory results by reliance thereon. Nothing contained herein is to be construed as a warranty or guarantee, express or implied, regarding any matter with respect to this product. Because Flowserve iscontinually improving and upgrading its product design, the specifications, dimensions and information contained herein are subject to change without notice. Should any question arise concerning theseprovisions, the purchaser/user should contact Flowserve Corporation at any one of its worldwide operations or offices. 2005 Flowserve Corporation, Irving, Texas, USA. Flowserve and Nordstrom Valves are registered trademarks of Flowserve Corporation.FCD NVABR1006-01 Printed in USA

NORDSTROM POLY-GAS VALVES FOR NATURAL GAS Flow Control Nordstrom Valves Why use polyethylene valves? Polyethylene Pipe-to-Metal Valve Systems: Subject to the inherent weakness of combining incompatible materials. May suffer damage from ground movement. Leaks may occur where the polyethylene and metal meet.

Related Documents:

Nordstrom Valves SEALANT AND SEALANT EQUIPMENT 3 Why Use Nordstrom Valves Sealants? Manufactured by the world's largest manufacturer of plug valves. Time-tested and proven by actual use in millions of valves. Nordstrom Valves Sealants have been tested to ensure maximum valve performance. Valve operating torque Solvent resistance

Poly(vinylcarbazo1e) Poly(vinylbutyra1) Poly(p-vinylphenol) Polystyrene Ethyl cellulose Poly(capro1actone) GE DC 11 Poly(methy1 methacrylate) Poly(butadieneacry1onitrile) Poly(viny1 chloride) Poly(viny1 isobutyl ether) Poly- 1 -butene 27.7 19.5 14-5 9-6 25-0 18.4 10.4 10-3 3

Nordstrom Bolted Gland-Type Iron Plug Valves 11 Dynamic Balance Plug Valves 12 Nordstrom Screwed Gland-Type Iron Plug Valves 13 Dimensional Tables 14-35 Conformance to Standard Specifications 36 Gas Safety Control Valves Approved by Factory Mutual Laboratories 37

Nordstrom Bolted Gland-Type Iron Plug Valves 11 Dynamic Balance Plug Valves 12 Nordstrom Screwed Gland-Type Iron Plug Valves 13 Dimensional Tables 14-35 Conformance to Standard Specifications 36 Gas Safety Control Valves Approved by Factory Mutual Laboratories 37

When Sven Nordstrom invented the first lubricated plug valves in 1914, people knew he was on to something good. Nordstrom patented his design in 1916 and Nordstrom's valves quickly gained a name for rugged reliability. Rockwell Manufacturing Company acquired the Merco-Nordstrom Valve Company in 1932 and rapidly expan-

Sven Nordstrom’s 1916 patent was the first of more than 90 Nordstrom patents that cover virtually every impro-vement to lubricated plug valves. In 1975, Nordstrom also began a new era for the industry by introducing the world’s first polyethylene valve for

The standard Nordstrom plug valve line includes low-pressure valves (ASME Class 150) in sizes 6, 8 and 12 for a broad range of applications in gas distribution and general industrial services. Nordstrom Valves Steel Lubricated Plug Valves FCD NVENBR1004-01 - 10/05 4

Beginning Reader Stories Level 01 Author: Clark Ness Created Date: 6/9/2015 3:03:34 AM .