OPC Server v5.xInstallation and SetupQuick Start ManualPC-KEP-MSoftware User Manual, 1st Edition, Rev. B

KEPDirect OPC ServeriiSoftware User Manual, 1st Edition, Rev. B

KEPDirect OPC Server WARNING Thank you for purchasing automation equipment from Automationdirect.com doing business as,AutomationDirect. We want your new automation equipment to operate safely. Anyone whoinstalls or uses this equipment should read this publication (and any other relevant publications)before installing or operating the equipment.To minimize the risk of potential safety problems, you should follow all applicable local and nationalcodes that regulate the installation and operation of your equipment. These codes vary from area toarea and usually change with time. It is your responsibility to determine which codes should befollowed, and to verify that the equipment, installation, and operation is in compliance with the latestrevision of these codes.At a minimum, you should follow all applicable sections of the National Fire Code, NationalElectrical Code, and the codes of the National Electrical Manufacturer’s Association (NEMA). Theremay be local regulatory or government offices that can also help determine which codes and standardsare necessary for safe installation and operation.Equipment damage or serious injury to personnel can result from the failure to follow all applicablecodes and standards. We do not guarantee the products described in this publication are suitable foryour particular application, nor do we assume any responsibility for your product design,installation, or operation.Our products are not fault-tolerant and are not designed, manufactured or intended for use or resaleas on-line control equipment in hazardous environments requiring fail-safe performance, such as inthe operation of nuclear facilities, aircraft navigation or communication systems, air traffic control,direct life support machines, or weapons systems, in which the failure of the product could leaddirectly to death, personal injury, or severe physical or environmental damage (“High Risk Activities”).AutomationDirect specifically disclaims any expressed or implied warranty of fitness for High RiskActivities.For additional warranty and safety information, see the Terms and Conditions section of our catalog.If you have any questions concerning the installation or operation of this equipment, or if you needadditional information, please call us at 770-844-4200.This publication is based on information that was available at the time it was printed. AtAutomationDirect we constantly strive to improve our products and services, so we reserve theright to make changes to the products and/or publications at any time without notice and without anyobligation. This publication may also discuss features that may not be available in certain revisions ofthe product.TrademarksThis publication may contain references to products produced and/or offered by other companies.The product and company names may be trademarked and are the sole property of their respectiveowners. AutomationDirect disclaims any proprietary interest in the marks and names of others.Copyright 2019, Automationdirect.com Incorporated, All Rights ReservedNo part of this manual shall be copied, reproduced, or transmitted in any way without the prior,written consent of Automationdirect.com , Incorporated. AutomationDirect retains theexclusive rights to all information included in this document.Software User Manual, 1st Edition, Rev. Biii

KEPDirect OPC Server AVERTISSEMENT Nous vous remercions d’avoir acheté l’équipement d’automatisation de Automationdirect.comMC, enfaisant des affaires comme, AutomationDirect. Nous tenons à ce que votre nouvel équipementd’automatisation fonctionne en toute sécurité. Toute personne qui installe ou utilise cet équipement doit lirela présente publication (et toutes les autres publications pertinentes) avant de l’installer ou de l’utiliser.Afin de réduire au minimum le risque d’éventuels problèmes de sécurité, vous devez respecter tous les codeslocaux et nationaux applicables régissant l’installation et le fonctionnement de votre équipement. Ces codesdiffèrent d’une région à l’autre et, habituellement, évoluent au fil du temps. Il vous incombe de déterminerles codes à respecter et de vous assurer que l’équipement, l’installation et le fonctionnement sont conformesaux exigences de la version la plus récente de ces codes.Vous devez, à tout le moins, respecter toutes les sections applicables du Code national de prévention desincendies, du Code national de l’électricité et des codes de la National Electrical Manufacturer’s Association(NEMA). Des organismes de réglementation ou des services gouvernementaux locaux peuvent égalementvous aider à déterminer les codes ainsi que les normes à respecter pour assurer une installation et unfonctionnement sûrs.L’omission de respecter la totalité des codes et des normes applicables peut entraîner des dommages àl’équipement ou causer de graves blessures au personnel. Nous ne garantissons pas que les produits décritsdans cette publication conviennent à votre application particulière et nous n’assumons aucune responsabilitéà l’égard de la conception, de l’installation ou du fonctionnement de votre produit.Nos produits ne sont pas insensibles aux défaillances et ne sont ni conçus ni fabriqués pour l’utilisation ou larevente en tant qu’équipement de commande en ligne dans des environnements dangereux nécessitant unesécurité absolue, par exemple, l’exploitation d’installations nucléaires, les systèmes de navigation aérienne oude communication, le contrôle de la circulation aérienne, les équipements de survie ou les systèmes d’armes,pour lesquels la défaillance du produit peut provoquer la mort, des blessures corporelles ou de gravesdommages matériels ou environnementaux («activités à risque élevé»). La société AutomationDirect nietoute garantie expresse ou implicite d’aptitude à l’emploi en ce qui a trait aux activités à risque élevé.Pour des renseignements additionnels touchant la garantie et la sécurité, veuillez consulter la sectionModalités et conditions de notre documentation. Si vous avez des questions au sujet de l’installation ou dufonctionnement de cet équipement, ou encore si vous avez besoin de renseignements supplémentaires,n’hésitez pas à nous téléphoner au 770-844-4200.Cette publication s’appuie sur l’information qui était disponible au moment de l’impression. À la sociétéAutomationDirect, nous nous efforçons constamment d’améliorer nos produits et services. C’estpourquoi nous nous réservons le droit d’apporter des modifications aux produits ou aux publications en touttemps, sans préavis ni quelque obligation que ce soit. La présente publication peut aussi porter sur descaractéristiques susceptibles de ne pas être offertes dans certaines versions révisées du produit.Marques de commerceLa présente publication peut contenir des références à des produits fabriqués ou offerts par d’autresentreprises. Les désignations des produits et des entreprises peuvent être des marques de commerce etappartiennent exclusivement à leurs propriétaires respectifs. AutomationDirect nie tout intérêt dans lesautres marques et désignations.Copyright 2019, Automationdirect.comMC Incorporated, Tous droits réservésNulle partie de ce manuel ne doit être copiée, reproduite ou transmise de quelque façon que ce soit sans leconsentement préalable écrit de la société Automationdirect.comMC Incorporated. AutomationDirectconserve les droits exclusifs à l’égard de tous les renseignements contenus dans le présent document.ivSoftware User Manual, 1st Edition, Rev. B

KEPDirect OPC ServerOPC Server Installation andSetup Quick Start ManualPlease include the manual number and the manual issue, bothshown below, when communicating with Technical Supportregarding this publication.Manual Number:Issue:Issue Date:PC-KEP-M1st Edition, Rev. B01/19Publication HistoryIssueDateDescription of Changes1st Edition02/11OriginalRevision A12/11Removed Windows 2000 SP4 references,no longer supported.Revision B01/19Corrected Step 10 page 89Software User Manual, 1st Edition, Rev. Bv

KEPDirect OPC ServerAUTOMATIONDIRECT.COM END USER LICENSEAGREEMENT AND LIMITED WARRANTYThe software accompanying this license agreement (the Software) is theproperty of AutomationDirect, or its suppliers, and is protected byUnited States and International Copyright laws and International treatyprovisions. No ownership rights are granted by this Agreement orpossession of the Software. Therefore, you must treat the licensedSoftware like any other copyrighted material (e.g., a book or musicalrecording), except that you may make a single copy for backup orarchival purposes. Your rights and obligations in its use are describedas follows:1. You may use and display this software on a single computer.2. You may make one copy of the Software for archival purposes oryou may copy the software onto your hard disk and hold theoriginal for archival purposes.3. You may not modify or attempt to reverse engineer the software,or make any attempt to change or even examine the source code ofthe Software.4. You may transfer the software to another computer using theutilities provided; however, the Software must be used on only asingle computer at one time.5. You may not give or distribute copies of the Software orwritten materials associated with the Software to others.6. You may not sub-license, sell, or lease the Software to anyperson or business.Return PolicyThe original licensee of the Software can return it within thirty (30) daysof purchase. Please call us for a Return Material AuthorizationNumber.Limited WarrantyAutomationDirect does not warrant that the Software will be error free,that it will satisfy your planned applications or that all defects in theSoftware can be corrected. If AutomationDirect provides informationor assistance regarding the use of the Software or otherwise,AutomationDirect is not assuming the role of engineering consultant.viSoftware User Manual, 1st Edition, Rev. B

KEPDirect OPC ServerAutomationDirect disclaims responsibility for any errors or omissionsarising in connection with engineering in which its software or suchinformation or assistance is used.The foregoing is the sole and exclusive warranty offered byAutomationDirect. AutomationDirect disclaims all other warranties,express or implied, including but not limited to the implied warrantiesof merchantability and fitness for a particular purpose, with regard tothe licensed Software and all accompanying materials.In no event shall AutomationDirect be liable for incidental orconsequential damages, including lost profit, lost savings, lostopportunities, or other incidental or consequential damages arising outof the use or inability to use the licensed Software, even ifAutomationDirect has been advised of the possibility of such damages.AutomationDirect’s entire liability shall be, at AutomationDirect’soption, either (a) return of the price paid for the Software (orcomponent), or (b) repair or replacement of the Software (orcomponent) that does not meet AutomationDirect’s Limited Warrantyand which is returned to AutomationDirect within the warranty period.This shall be the sole and exclusive obligation of AutomationDirectand your sole and exclusive remedy with respect to any such failure.The Limited Warranty is void if failure of the Software (or component)has resulted from accident, abuse or misapplication.TrademarksMicrosoft and Microsoft Excel are registered trademarks,Windows is a trademark of Microsoft Corporation.Software User Manual, 1st Edition, Rev. Bvii

KEPDirect OPC ServerviiiSoftware User Manual, 1st Edition, Rev. B

KEPDirect OPC ServerTable of ContentsIntroduction1Preparing for Installation3Installation of KEPDirect OPC Server8KEPDirect OPC Server Setup Summary21Create a New Project for Serial Devices22Using OPC Quick Client to Test a Serial Device Setup39Create a New Project for ECOM Modules42Using OPC Quick Client to Test an ECOM Module Setup58Create a New Project for EBC Modules61Using OPC Quick Client to Test an EBC Module Setup79Create a New Project for Productivity300083Using OPC Quick Client to Test a Productivity3000 Setup93Creating Tags . . .94Glossary110Appendix AA-1Project Example Using LookoutDirect as an OPC ClientAppendix BAnalog I/O Setup and DiagnosticsAppendix CGS Drives Parameter and Status AddressingSoftware User Manual, 1st Edition, Rev. BA-1B-1B-1C-1C-1ix

KEPDirect OPC ServerxSoftware User Manual, 1st Edition, Rev. B

KEPDirect OPC ServerIntroductionThe Purpose of this Supplementary ManualThis KEPDirect Setup manual provides enough of the basics to installthe OPC* server* software without having to read the complete onlinehelp documentation that covers all the details of KEPDirect. Exercisecaution: This is not intended to replace reading the online helpdocumentation. This is intended only as a supplement. This is only aquick start guide.Who Can and Should Use KEPDirect?KEPDirect is a software based server that is designed for accuratecommunication, quick setup and unmatched interoperability betweenclient applications, industrial devices and systems. This server providesa wide range of plug-in device drivers and components that suit mostcommunication needs. KEPDirect can interface your favorite Windowsclient with most AutomationDirect control systems. Compatibleproducts are listed in the “Supported Devices” and “Supported I/OModules” sections of this chapter.Using KEPDirect with your AutomationDirect I/O system provides thefollowing advantages: V ersatility: Connect your favorite HMI/SCADA* software to avariety of AutomationDirect I/O products. C ost Savings: Design a low-cost data acquisition/monitoringsystem using affordable AutomationDirect controllers and I/Omodules. C onvenience: Remotely control AutomationDirect systems fromany client PC. For instance, connect to one of our DURApulse orGS series AC drives via a GS-EDRV module and have the abilityto control start/ stop, speed and many other drive functionsremotely. C ustom Interfacing: Interface your custom VisualBASIC or VisualC application to AutomationDirect I/O systems and eliminatetime-consuming driver development.*See GlossarySoftware User Manual, 1st Edition, Rev. B1

KEPDirect OPC ServerDiagram Showing the Basic System CompatibilityYour computer withKEPDirect installedand your favoriteWindows client.Industrial DIN Rail MountEthernet Switch(SE-SW5U) (Optional)DL05 Controllerand I/ODL06 Controllerand I/ODL205 Controllerand I/ODL405 Controllerand I/OProductivity3000Controller and I/O2Software User Manual, 1st Edition, Rev. B

KEPDirect OPC ServerPreparing for InstallationCheck your PC Hardware RequirementsThe OPC server has minimum system requirements for both softwareand hardware. These requirements must be met in order for theapplication to operate as designed.Minimum System RequirementsThe OPC server requires the following hardware at a minimum: 2.0 GHz Processor 1 GB installed RAM 180 MB available disk space Ethernet Card (required for Ethernet drivers or serial drivers that utilizeEthernet encapsulation) Super VGA (800 x 600) or higher resolution video adapter andmonitor K eyboard and Microsoft mouse or compatiblepointing deviceSupported Operating SystemsThis application supports the following MicrosoftWindows operating systems: Windows 10* Windows 7 Pro and Ultimate* Windows XP* SP2 (strongly recommended for industrial settings) W indows Server 2003* SP2 (strongly recommended for industrialsettings) Vista Business/Ultimate* Windows Server 2008* (strongly recommended for industrial settings)* Includes support for 64 bit operating systems.Software User Manual, 1st Edition, Rev. B3

KEPDirect OPC ServerSupported DeviceswKEPDirect Compatible DL05/06/105 Series Controllers,Ports and Communications ModulesCPUCPU Port 1D0-05(*)D0-06(*)F1-130(*)CPU Port EPDirect Compatible DL205 Series Controllers,Ports and Communications ModulesCPUCPU Port 0CPU Port 1D2-230D2-240D2-250-1D2-260H2-EBC(*)CPU Port S-232/422EthernetEthernetEthernetKEPDirect Compatible DL305 Series Controllers,Ports and Communications ModulesCPUCPU Port 1CPU Port 232/422KEPDirect Compatible DL405 Series Controllers,Ports and Communications ModulesCPUCPU Port 0CPU Port 1CPU Port 2CPU Port ernetRS-232/422EthernetRS-232/422EthernetKEPDirect Compatible Productivity Series Controllers,Ports and Communications ModulesCPUCPU PortCPU PortCPU 3-RSRS-232/485P3-ESCMRS-422/485, EthernetKEPDirect Compatible GS Series Drives,Ports and Communications ModulesDriveDrive An asterisk suffix (*) means there are multiple part numbers. Example: part numbers H2-ECOM, H2-ECOM100, H2-ECOM-Fare collectively referred to as H2-ECOM(*) in the chart.4Software User Manual, 1st Edition, Rev. B

KEPDirect OPC ServerSupported I/O ModulesH2- EBC(-F), H2-EBC100 and -02DA-2F2-02DA-1L8 Pt 12–21 VDC Input16 Pt 24VDC Input32 Pt 24VDC Input32 Pt 5–15 VDC Input8 Pt 110VAC Input8 Pt 170–265 VAC Input, 2 Commons16 Pt 110VAC Input8 Pt Switch Slide Simulator4 Pt 12–24 VDC Sink Output8 Pt 12–24 VDC Sink Output16 Pt 12–24 VDC Sink (2 Terminals)8 Pt 12–24 VDC Source Output32 Pt 24VDC Source output16 Pt 12–24 VDC Output (2 Terminals)32 Pt 24VDC Output8 Pt 18–220 VAC Output12 Pt 18–110 VAC Output4 Pt Isolated Relay5–30 VDC or 5–250 VAC Output8 Pt Relay Output 12–28 VDC / 12–250 VAC8 Pt 24–140 VAC Output, 1.5 A/Pt.8 Pt Relay Output, 10A/Common12–28 VDC / 12–250 VAC8 Pt Relay Output12–28 VDC or 12–250 VAC12 Pt Relay Output 5–30 VDC or 5–250 VACCombo 4 Pt 24VDC Input and4 Pt Relay Output4 CH Analog In 4–20 mA 12-Bit Res4 Pt Analog Input 4–20 mA 12-Bit12 VDC Power Needed4 CH Analog Input Volt 12-Bit Res4 Pt Analog Input Volt 12-Bit12 VDC Power Needed8 CH Analog Input 4–20 mA 12-Bit8 CH Analog Input Voltage 12-Bit4 CH RTD, 0.1 Deg C Resolution4 CH Thermocouple or 16-bit V Input2 CH Analog Output 4–20 mA 12-Bit2 CH Analog Output Voltage 12-Bit2 CH Analog Output 12-BitUse with 12VDC Power Supply2 CH Analog Output 12-BitUse with 12VDC Power Supply8 CH Analog Output 4–20 mA 12-Bit8 CH 0–5 VDC or 0–10 VDCF2-08DA-212-Bit Analog OutputF2-02DAS-12 CH Isolated 4–20 mA 16-Bit Analog OutputF2-02DAS-22 CH Isolated 4–20 mA 16-Bit Analog OutputF2-4AD2DA4 CH In & 2 CH Out Analog 4–20 mA 12-BitF2-8AD4DA-1 8 CH Analog Input 0–20 mA 12-,14- or 16-Bit4 CH Analog Output 4–20 mA 16-BitF2-8AD4DA-2 8 CH Analog In 0–5 VDC or0–10 VDC 12-, 14- or 16-Bit.4 CH Analog Output 0–5 VDC or0–10 VDC 15- or 16-Bit.SoftwareManual,1st Edition,BH2-CTRIO UserHighSpeed C(-F) and DL405Description8 Pt 24–48 VDC Source Input16 Pt 12–24 VDC Source Input16 Pt 12–24 VDC In Fast Response16 Pt Switch Slide Simulator32 Pt 24 VDC Sink Source Input32 Pt 5–12 VDC Sink Source Input64 Pt 20–28 VDC Source Input8 Pt 110–220 VAC Input16 Pt 110VAC Input16 Pt 220VAC Input Module16 Pt 12–24 VAC/VDC Sink Input8 Pt 90–150 VAC/DC Sink Iso. Input8 Pt 12–24 VDC Sink Output8 Pt 24–150 VDC SinkSource Isolated Output16 Pt 5–24 VDC Sink Output16 Pt 12–24 VDC Source Output32 Pt 5–24 VDC Sink Output32 Pt 5–24 VDC Sink Output32 Pt 12–24 VDC Source Output64 Pt 5–24 VDC Sink Output8 Pt 18–220 VAC Output16 Pt 18–220 VAC Output8 Pt Relay 5–30 VDC or 5–250 VAC Output8 Pt Relay 12–30 VDC or 12–250 VAC Output8 Pt Relay 12–30 VDC or 12–250 VAC Output16 Pt Relay 5–30 VDC or 5–250 VAC Output4 CH Analog Input Voltage/Current4 CH Iso. Analog In Voltage/Current8 CH Analog Input Voltage/Current2 CH Analog Output Voltage/Current4 CH Analog Output Voltage/Current4 CH Analog Output Current4 CH Analog Output Voltage4 CH Isolated. 4–20mA 16-Bit Analog Output4 CH Isolated 16-Bit Analog Voltage OutputF4-08DA-18 CH Analog Output Current8 CH 0–5 VDC or 0–10 VDC 12-Bit AnalogOutputF4-16DA-116 CH Analog Output Current16 CH 0–5 VDC or 0–10 VDC 12-Bit AnalogF4-16DA-2Output8 CH Thermo Module For TypeF4-08THM(J,E,K,R,S,T,B,N,C)8 CH Thermo Module For TypeF4-08THM-n(J,E,K,R,S,T,B,C,P)F4-08RTD8 CH RTD ModuleH4-CTRIOHigh Speed Counter/Pulse Output ModuleF4-08DA-25

KEPDirect OPC ServerSupported I/O Modules 4DA-1T1F-8AD4DA-2T1H-CTRIO6Terminator I/ODescriptionModule8 Pt 12–24 VDC Sink Source Input16 Pt 12–24 VDC Sink Source Input8 Pt 110VAC Input16 Pt 110VAC Input8 Pt 12–24 VDC Sink Output8 Pt 12–24 VDC Source Output16 Pt 12–24 VDC Sink Output16 Pt 12–24 VDC Source Output8 Pt 110–240 VAC Output16 Pt 110–240 VAC Output8 Pt 110–240 VAC OutputIsolated Commons8 Pt Relay Output 5–30 VDC or5–240 VAC16 Pt Relay Output 5–30 VDC or5–240 VAC8 Pt Isolated Relay Output5–30 VDC or 5–240 VAC8 CH Analog Input 4–20 mA14-Bit Resolution8 CH Analog Input 14-Bit Resolution16 CH Analog Input 4–20 mA14-Bit Resolution16 CH Analog Input Voltage14-Bit Resolution8 CH Analog Output 4–20 mA12-Bit Resolution8 CH Analog Output Voltage12-Bit Resolution16 CH Analog Output 4–20 mA12-Bit Resolution16 CH Analog Output Voltage12-Bit Resolution16 CH. TD1D0-16TD1D0-10TD2D0-16TD2D0-07CDRD0-08TR14 CH Thermocouple 16 Bit ResolutionTerminator I/O 8 CH Analog Input 4 CHAnalog Output CurrentTerminator I/O 8 CH Analog Input 4 CHAnalog Output VoltageHigh Speed Counter/Pulse Output ModuleF0-2AD2DA-2DL05/ DL06DescriptionF0-04RTDF0-04THM8 Pt Input Simulator10 Pt 12–24 VDC Sink Source Input10 Pt Fast 12–24 VDC Sink Source Input16 Pt 20–28 VDC Sink Source Input8 Pt 110VAC Input10 Pt 12–24 VDC Sink Output16 Pt 6–27 VDC Sink Output10 Pt 12–24 VDC Source Output16 Pt 12–24 VDC Source Output4 Pt 12–24 VDC Input, 3 Pt Relay Output8 Pt Relay Output 6–27 VDC or 6–240 VAC4 Pt 12–24 VDC Input, 4 Pt 12–24 VDC SinkOutput4 Pt High Current Relay Output 5–30 VDC or5–125 VAC4 CH Analog Input 0–20 mA or 4–20 mA12 Bit Resolution8 CH Analog Input 0–20 mA16 Bit Resolution4 CH Analog Input 0–5 V or 0–10 V12 Bit Resolution8 CH Analog Input 0–5 V or 0–10 V16 Bit Resolution4 CH Analog Output 4–20 mA16 Bit Resolution8 CH Analog Output 4–10 mA16 Bit Resolution4 CH Analog Output 0–10 VDC16 Bit Resolution8 CH Analog Output 0–10 VDC16 Bit Resolution4 CH Input/2–CH Output Analog Combination0–20 mA or 4–20 mA 12 Bit Resolution2 CH Input/2–CH Output Analog Combination0–5 VDC or 0–10 VDC 12 Bit Resolution4 CH Input/2–CH Output Analog Combination0–5 VDC or 0–10 VDC 12 Bit Resolution4 CH RTD4 CH Thermocouple 16 Bit ResolutionH0-CTRIOHigh Speed Counter/Pulse Output 2F0-4AD2DA-1F0-4AD2DA-2Software User Manual, 1st Edition, Rev. B

KEPDirect OPC ServerSupported I/O Modules A-1D3-08NA-2D3-16NAD3-08NE3D3-16NE3DL-305 D3-04TASF3-08TASF3-08TAS-1D3-08TA-1D3-08TA-28 Pt 18–36 VDC Source Input16 Pt 18–36 VDC Source Input16 Pt Fast 18–36 VDC Source Input8 Pt 85–132 VAC Input8 Pt 220VAC Input16 Pt 110VAC Input8 Pt 20–28 VAC/ VDC Sink Source Input16 Pt 14–30 VAC/ VDC Sink Source Input4 CH Analog Input 0–5 VDC, 0–10 VDC, –5– 5VDC, –10– 10 VDC, 1–5 VDC, 0–20 mA,4–20mA 12-Bit Resolution8 CH Analog Input 4–20mA12-Bit Resolution16 CH Analog Input –5– 5 VDC, –10– 10 VDC,0–10 VDC, 0–20 mA 12-Bit Resolution8 Pt Input Simulator8 Pt 5–24 VDC Sink Output16 Pt 5VDC (TTL & CMOS) or 12–24 VDCSink Source Input8 Pt 5–24 VDC Source Output16 Pt 5–24 VDC Sink Output16 Pt 5–24 VDC Sink Output16 Pt 5–24 VDC Source Output4 Pt 80–265 VAC Output8 Pt 12–250 VAC Output8 Pt 20–125 VAC Output8 Pt 80–265 VAC Output8 Pt 80–265 VAC OutputF3-16TA-216 Pt 20–125 VAC OutputD3-16TA-216 Pt 15–265 VAC Output4 CH Analog Output 0–5 VDC, 0–10 VDC,–5 – 5 VDC, –10– 10 VDC, 0–20 mA, 4–20 mA12-Bit Resolution4 Ch Analog Output 0–5 VDC, 0–10 VDC,4–12 mA, 4–20 mA 12-Bit 1P3-16AD-2P3-08RTDP3-08THMD3-08TR8 Pt Relay Output 5–30 VDC / 5–265 VACF3-08TRS-18 Pt Relay Output 12–30 VDC or 12–250 -16DA-1P3-16DA-2F3-08TRS-28 Pt Relay Output 12–30 VDC or 12–125 VACP3-8AD4DA-1D3-16TR16 Pt Relay Output 5–30 VDC / 5–265 VACF3-08THM-x8 CH ty3000Description16 Pt Input Simulator8 Pt 12–24 VDC Sink Source Input16 Pt 12–24 VDC Sink Source Input32 Pt 24VDC Sink Source Input64 Pt 24VDC Sink Source Input8 Pt 110–240 VAC Input16 Pt 110–240 VAC Input8 Pt 6–27 VDC Sink Output8 Pt 6–27 VDC Source Output16 Pt 6–27 VDC Sink Output16 Pt 6–27 VDC Source Output32 Pt 6–27 VDC Sink Output32 Pt 6–27 VDC Source Output64 Pt 6–27 VDC Sink Output64 Pt 6–27 VDC Source Output8 Pt 110–240 VAC Output16 Pt 110–240 VAC Output8 Pt Isolated Relay Output6–27 VDC or 6–240 VAC16 Pt Relay Output6–27 VDC or 6–240 VAC8 Pt Isolated Relay Output5–30 VDC or 5–240 VAC4 CH Iso. Analog In Voltage/Current8 CH Analog Input Voltage/Current16 CH Analog Input Current16 CH Analog Input Voltage8 CH RTD Module8 CH Thermo Module For Type(J,E,K,R,S,T,B,N,C)4 CH Analog Output Voltage/Current8 CH Analog Output Current8 CH Analog Output Voltage6 CH Isolated Analog Output Currentw6 CH Isolated Analog Output Voltage16 CH Isolated Analog Output Current16 CH Isolated Analog Output VoltageCombo 8 CH Analog Input Current and4 CH Analog Output CurrentCombo 8 CH Analog Input Voltage and4 CH Analog Output VoltageGo to the Automationdirect.com website for information on anydevice introduced after publication of this manual.Software User Manual, 1st Edition, Rev. B7

KEPDirect OPC ServerInstallation of KEPDirect OPC ServerThe KEPDirect software installs as a demo package with fulldevelopment capabilities, but with a restricted Runtime application.The Runtime application in the demo version is restricted to two hoursof operation. However, with the purchase of a software license, thisrestriction is removed. Download the demo of the software direct.com/demos.html)The following section outlines the step by step instructions for theinstall.Step 1: Welcome WindowThe KEPDirect install wizard starts and opens the Welcome windowshown below. This window issues a reminder to exit all other Windowapplications. If you are unsure of the programs that may be running,open the Task Manager by pressing the Ctrl-ALT-Delete keys at thesame time. Close any opened applications by selecting them andclicking on the End Task button of the Task Manager. Click on the Nextbutton to proceed with the installation.8Software User Manual, 1st Edition, Rev. B

KEPDirect OPC ServerStep 2: License AgreementThe wizard displays the License Agreement shown below. Read theagreement and select I accept the license agreement if you agreewith the terms and conditions.Select Next to continue with the installation.Step 3: Select the Installation DirectoryThe Destination Folder window displays the folder (or directory)where the KEPDirect program files will be installed. You may choosea different folder by clicking on the Browse button and selecting apreferred directory.Software User Manual, 1st Edition, Rev. B9

KEPDirect OPC ServerIf you accept the displayed folder or select a preferred directory, clickon the Next button to continue with the KEPDirect installation.Step 4: Select the Application DirectoryThe Specify Application Data Folder window displays the folder (ordirectory) where the KEPDirect application files will be installed.Application files such as security files and certifications, will be storedin this folder. Although it is not recommended, you may choose adifferent folder by clicking on the Browse button and selecting apreferred directory. If you accept the displayed folder or select apreferred directory, click on the Next button to continue with theKEPDirect installation.Step 5: Select the Shortcuts Directory10Software User Manual, 1st Edition, Rev. B

KEPDirect OPC ServerThe Shortcuts Folder window displays the folder (or directory) wherethe KEPDirect shortcuts will be stored. You may choose a differentfolder by clicking on the Browse button and selecting a preferreddirectory. If you accept the displayed folder or select a preferreddirectory, click on the Next button to continue with the KEPDirectinstallation.Step 6: Select FeaturesThe wizard now displays the Select Features window. This windowallows

Using OPC Quick Client to Test an ECOM Module Setup 58 Create a New Project for EBC Modules 61 Using OPC Quick Client to Test an EBC Module Setup 79 Create a New Project for Productivity3000 83. x KEPDir

Related Documents:

D. OPC UA using LabVIEW (OPC UA Server OPC UA Clients) E. OPC with Visual Studio, MATLAB or Python. Select one of the following I. Trend OPC DA Data using Visual Studio Measurement Studio II. Get Temperature Data into MATLAB using MATLAB OPC Toolbox III. Get Temperature Data into Python F. OPC Network: Send OPC data between different .

OMRON Guide to Using CX-Server OPC in Microsoft .Net Page 4 About this Manual This manual describes the CX-Server OPC client application and its ability to interface with OPC servers. It does not provide detailed information concerning OPC itself, or the CX-Server OPC server.The main CX-Server OPC user

2.2 OPC Scout V10 2.2.1 OPC client for test purposes SIMATIC Net OPC Scout V10 OPC Scout V10 is a standard OPC client that is supplied with SIMATIC NET. OPC Scout V10 can be used as a test tool when commissioning and checking an OPC system. Note For more information about

The OPC Quick Client allows you to perform operations on an OPC server at the Server, Group and Item level. This allows a user to test out the functionality of an OPC server prior to configuring the HMI programs2 that will ultimately interface with the OPC server. The OPC Quick Client also allows the user to

This section explains the main features of the Cyberlogic OPC Server as they relate to the Data Logger feature. Refer to the Cyberlogic OPC Server Help for a full discussion of the common features of the Cyberlogic OPC Server. If you are new to OPC or the Cyberlogic OPC Server, we strongly recommend that you read the OPC Tutorial first.

1.1 About BACnet OPC Server The BACnet OPC Server is a software gateway which translates the BACnet protocol on one side (typically BACnet/IP) to an OPC data format so that data can be exchanged between a Building Automation network and a SCADA system. The BACnet OPC Server software must be loaded on the same physical computer as the OPC Client .

The OPC Quick Client allows you to perform operations on an OPC server at the Server, Group and Item level. This allows a user to test out the functionality of an OPC server prior to configuring the HMI programs2 that will ultimately interface with the OPC server. The OPC Quick Client also allows the user to

The DeltaV OPC Data Access Server provides real-time, read/ write data communications to OPC client applications. For OPC data communications where you can’t afford interruptions, the DeltaV system offers OPC server redundancy to minimize the risk of interruptions. You can add a standby OPC ser