Wall-mounted single drives, ACS880-01Our wall-mounted drives are designed on ABB’s commondrives architecture. They are customized to the precise needsof industries such as oil and gas, mining, metals, chemicals,cement, power plants, material handling, pulp and paper,sawmills and marine. They are designed to control a widerange of applications including cranes, extruders, winches,winders, conveyors, mixers, compressors, pumps and fans.The drive comes in nine different frame sizes (R1 to R9) foreasy installation and commissioning.At the heart of the drive is direct torque control (DTC), ABB’spremier motor control technology. The extensive range ofoptions include EMC filters, encoder and resolver interfaces,du/dt filters, sine filters, chokes and brake resistors, as wellas application specific software. Built-in safety featuresreduce the need for external safety components. Multipledrives can be daisy-chained for synchronized drive-to-drivecommunication.The drives offering includes enclosure classes IP20, IP21 andIP55 for dusty and wet environments. Our offering also coversan option for flange mounting with IP55 back side protection.In flange mounting the control electronics are separated fromthe cooling airflow for better thermal management.ABB provides an extensive selection of support documentationfor planning including dimension drawings in different formats,EPLAN P8 macros and line apparatus selection tool forselecting external components on the line side and motor sideof the drive.Main features Enclosure classes IP20, IP21 and IP55 for differentenvironments Compact design for easy installation, commissioning andmaintenance Integrated safety including safe torque off (STO) asstandard and the optional safety functions module,(TÜV Nord certified) Supports various motor types including synchronousreluctance motors Intuitive control panel with USB connection Removable memory unit for easy maintenance Drive composer PC tool for commissioning and configuration Primary control program - common software usedthroughout the ACS880 drive series Control unit supporting a wide range of fieldbuses,feedback devices and input/output options Coated boards as standard Controllable cooling fan Incoming air temperature measurement for protecting thedrive from different temperature related failure mechanisms Built-in braking chopper, option for frame sizes R5 to R9 EMC filter option du/dt filter option for motor protection Built-in choke Supporting optimized cabinet mounting with option(P940, P944) Flange mounting optionThe type approved ACS880-01 marine drive, providesadvanced reliability and availability at sea. The drive fulfillsmarine and offshore requirements and the design andoperations have been tested according to marine typeapproval requirements. ACS880-01 comes with marine typeapproval from various key classification bodies.ACS880-01,frame sizes R1 to R9, IP21ACS880-01,frame sizes R1, R8 and R5, IP20ACS880-01,frame sizes R1, R8 and R5, IP55

Ratings, types and voltagesWall-mounted drives, ACS880-01U N 230 V (range 208 to 240 V). The power ratings are valid at nominal voltage 230 V (0.75 to 100 Hp).Nominal ratingsLight-duty use(10% overload for 1 min)Heavy-duty use(50% overload for 1 min)PLdI LdI 2HdNoiselevelHeatdissipationAir flowType 2626525279791651651652562562652653243U N 500 V (range 380 to 500 V). The power ratings are valid at nominal voltage 480 V (0.75 to 350 Hp).Nominal ratingsLight-duty use(10% overload for 1 min)Heavy-duty use(50% overload for 1 min)PLdI LdI 240302361414 156180260302361 2)NoiselevelHeatdissipationAir flowType 1-180A-5ACS880-01-240A-5 4ACS880-01-302A-5 3ACS880-01-361A-5 6ACS880-01-414A-5 97979165165165256256265265324677677677Light-duty useILdContinuous rms output current allowing 10% overload for1 minute every 5 minutes.PLdTypical motor power in light-overload use.1)2)3)Heavy-duty useI2HDContinuous rms output current allowing 50% overload for1 minute every 5 minutes.PHdTypical motor power in heavy-duty use.4)5)Ratings apply at an ambient temperature of 40 C (104 F) unless otherwise noted.6)To achieve the rated motor power given in the table, the rated current of the drivemust be higher than or equal to the rated motor current.For drives with enclosure class UL type 1 (IP21), the ratings apply at 30 C (86 F)ambient temperature. At ambient temperature 40 C (104oF), rating is 393A125% overload for 1 minute, every 5 minutes.For drives with enclosure class UL type 12 (IP55), the ratings apply at 40 Cambient temperature. At higher temperature the derating is 1%/1 C from 40 to45 C and 2.5%/1 C from 45 to 55 C.For drives with enclosure class UL type 12 (IP55), the ratings apply at 40 Cambient temperature. At higher temperature the derating is 1%/1 C from 40 to50 C and 2.5%/1 C from 50 to 55 C.For drives with enclosure class UL type 12 (IP55), the maximum ambienttemperature is 35 C (95 F).For drives with enclosure class UL type 12 (IP55), the ratings apply at 40 Cambient temperature. At higher temperature the derating is 1%/1 C from 40 to45 C, 2.5%/1 C from 45 to 50 C, and 5%/1 C from 50 to 55 C.

Ratings, types and voltagesWall-mounted drives, ACS880-01UN 690 V (range 525 to 690 V). The power ratings are valid at nominal voltage 575 V (5 to 250 Hp)Nominal ratingsLight-duty use(10% overload for 1 min)PLdI LdHeavy-duty use(50% overload for 1 min)I 2HdNoiselevelHeatdissipationAir 677677Height (H1)Height (H2)UL type 4A-7 3ACS880-01-210A-7 7ACS880-01-271A-7 pe designationWidthUL type 1openIP20Depth( P940)UL type 1IP21Depth( P944)UL type 1openIP20UL typeopenWeightIP21UL type .038016.341316.341321698H1 Height with cable entry boxH2 Height without cable entry box8)Comes with main power clamp (Note: IP20 variant only)FramesizeILdP LdI HdPHdHeight (H)Width (W)Depth (D)WeightUL type 12IP55UL type 12IP55UL type 12IP55UL type 5972R946.8118817.043118.8477220100Light-overload useContinuous current allowing 10% ILd for 1 min/5 min at 40 C.Typical motor power in light-overload use.Heavy-duty useContinuous current allowing 50% IHd for 1 min/5 min at 40 C.Typical motor power in heavy-duty use.3)4)5)6)The ratings apply at 40 C ambient temperature. At higher temperatures (up to 55 C)the derating is 1%/1 C.7)For drives with enclosure class IP55 the ratings apply at 40 C ambient temperature.At higher temperature the derating is from 40 to 45 C 1%/1 C and 45 to 55 C2.5%/1 C.For drives with enclosure class IP55 the ratings apply at 40 C ambient temperature.At higher temperature the derating is from 40 to 50 C 1%/1 C and 50 to 55 C2.5%/1 C.For drives with enclosure class IP55 the maximum ambient temperature is 35 C.For drives with enclosure class IP55 the ratings apply at 40 C ambient temperature.At higher temperatures the derating is from 40 to 45 C 1%/1 C and 45 to 50 C2.5%/1 C and 50 to 55 C 5%/1 C.For drives with IP55 enclosure class the ratings apply at 40 C ambient temperature.At higher temperatures the derating is from 40 to 45 C 3.5%/1 C. Note: Maximumambient temperature is 45 C.

How to select a driveMany of the features for the ACS880 single drives are built-inas standard, making selection easy. A wide range of optionsare available to optimize the drive for different requirements.To choose the right drive for your application, please refer tothe rating tables or use ABB’s DriveSize dimensioning tool(page 47). The selected driveType designation:ACS880–XX–XXXX–X has a unique type designation, which identifies the drive byconstruction, power and voltage range. The options are addedto the type designation with a “plus” code. Build up your ownordering code using the type designation key or contact yourlocal ABB drives sales office and let them know your needs/requirements.XXXXProduct seriesTypes and constructionRatingsVoltagesOptionsTechnical dataMains connectionVoltage and3-phase, UN2 208 to 240 V, 10/-15% (-01)3-phase, U N5 380 to 500 V, 10/-15% (-01),power range 10% (-07,-17,-37)3-phase, U N7 525 to 690 V, 10/-15% (-01), 10% (-07,-17,-37)0.75 to 350 hp (0.55 to 250 kW) (-01)50 to 3000 hp (45 to 2800 kW) (-07)250 to 4250 hp (250 to 3200 kW) (-17, -37)Frequency50/60 Hz 5%Power factor(ACS880-01, -07) cosϕ 1 0.98 (fundamental)cosϕ 0.93 to 0.95 (total)Power factor(ACS880-17, -37) cosϕ1 1 (fundamental)Efficiency (at98% (-01,-07)nominal power)97% (-17,-37)Motor connectionVoltage3-phase output voltage 0 to UN2 /UN3 /UN5 /UN71) 2)Frequency0 to 500 HzMotor controlDirect torque control (DTC)Torque control:Open loopClosed loopTorque step rise time: 5 ms with nominal torque 5 ms with nominal torqueNon-linearity: 4% with nominal torque 3% with nominal torqueStatic accuracy:10% of motor slip0.01% of nominal speedDynamic accuracy:0.3 to 0.4% seconds with 100% torque step0.1 to 0.2% seconds with 100% torque stepOpen loopClosed loopSpeed control:Open loopClosed loopOpen loopClosed loopProduct compliance- CE- Low Voltage Directive 2006/95/EC- Machinery Directive 2006/42/EC- EMC Directive 2004/108/EC- Quality assurance system ISO 9001 and Environmental system ISO 14001- RoHS- UL, cUL 508A or cUL 508C and CSA C22.2 NO.14-10, C-Tick, EAC 4)- Functional safety: STO TÜV Nord certificate- ATEX-certified Safe Disconnection Function, Ex II (2) GD 5)- Marine type approvals for -01EMC according to EN 61800-3:2004 A1:2012Categories C3 and C2 with internal optionEnvironmental limitsAmbienttemperatureTransportStorageOperation (air-cooled)-40 to 70 C-40 to 70 C-15 to 55 C, no frost allowed (-01)0 to 50 C, no frost allowed (-07, -17, -37) 40 to 55 C with derating (-01) 3) 40 to 50 C with derating of 1%/1 C (-07,-17,-37)Cooling methodAir-cooledDry clean airAltitude0 to 1,000 m1,000 to 4,000 mWithout deratingWith derating of 1%/100 m6)Relative humidityDegree of protectionIP20IP21IP22IP42, IP54IP55Paint colorContamination levelsStorage5 to 95%, no condensation allowedTransportationIEC 60721-3-2, Class 2C2 (chemical gases),Class 2S2 (solid particles)OperationIEC 60721-3-3, Class 3C2 (chemicalgases), Class 3S2 (solid particles)Functional safetyStandardOption (-01)Standard (-01)Standard (-07, -17, -37)Option (-07, -17, -37)Option (-01)RAL 9017/9002 (-01), RAL 9017/7035 (-07, -17, -37)No conductive dust allowedIEC 60721-3-1, Class 1C2 (chemical gases),Class 1S2 (solid particles)Safe torque off (STO according EN/IEC 61800-5-2)IEC 61508 ed2: SIL 3, IEC 61511: SIL 3,EN/IEC 62061: SIL CL 3, EN ISO 13849-1: PL eWith internal safetySafe stop 1 (SS1), safely-limited speed (SLS), safeoption safety functions stop emergency (SSE), safe brake control, (SBC)moduleand safe maximum speed (SMS), prevention ofunexpected startup (POUS), Safe direction (SDI),Safe speed monitor (SSM), EN/IEC 61800-5-2,IEC 61508 ed2: SIL 3, IEC 61511: SIL 3,EN/IEC 62061: SIL CL 3, EN ISO 13849-1: PL eTÜV Nord certifiedFieldbuscommunicationPROFIsafe over profinet, certifiedC Chemically active substancesS Mechanically active substances1)For higher operational output frequencies please contact your local ABB office2)Operation above 120 Hz might require type specific derating, please contact yourlocal ABB office3)Please see pages 12 to 13 for further details4)EAC has replaced GOST R5)Codes L513/ L514, Q971 for -07, -17,- 376)Derating reduced by lower than 40 oC ambient temperature

Contact usFor more information please contact yourlocal ABB representative or visit: Copyright 2016 ABB. All rights reserved.Specifications subject to change without notice.www.abb.com/drivesACS880 singledrives web page

ABB provides an extensive selection of support documentation for planning including dimension drawings in different formats, EPLAN P8 macros and line apparatus selection tool for selecting external components on the line side and motor side of the drive. The type approved ACS880-01 marine dri

Related Documents:

*ACS880-01 drives hardware manual 3AUA0000078093 *ACS880-04 drive modules (200 to 710 kW, 300 to 700 hp) hardware manual 3AUA0000128301 ACS880-04 single drive module packages hardware manual 3AUA0000138495 *ACS880-07 drives (45 to 630 kW, 50 to 700 hp) hardware manual 3AUA0000105718 *ACS880-07 drives (560 to 2800 kW) hardware manual 3AUA0000143261

8 ABB INDUSTRIAL DRIVES, ACS880, SINGLE DRIVES, CATALOG — Easy to use All-compatible user interface saves commissioning and learning time The ACS880 is part of ABB’s all-compatible drives portfolio. Other drives in this portfolio are the ACS380, ACS480 and ACS580. These drives share the same easy-to-use PC tools and multilingual control panels.

Catalog ABB industrial drives ACS880 single drives 3 The ACS880 series drives are part of ABB’s all-compatible drives portfolio. Compatible with virtually all types of processes, automation systems, users and business requirements they are designed to tackle any motor-driven application, in any industry, whatever the power range. The

Catalog ABB industrial drives ACS880 single drives 3 The ACS880 series drives are part of ABB's all-compatible drives portfolio. Compatible with virtually all types of processes, automation systems, users and business requirements they are designed to tackle any motor-driven application, in any industry, whatever the power range. The

Drive application programming manual (IEC 61131-3) 3AUA0000127808 ACS880 diode supply control program firmware manual 3AUA0000103295 ACS880 IGBT supply control program firmware manual 3AUA0000131562 ACS880 distributed I/O bus supplement 3AXD50000126880 Option manuals and guides ACX-AP-x assistant con

ABB-Vertretung. *In der Dokumenten-Bibliothek vorhanden. *Hyperlink-Listen zu den Produkthandbüchern Code (Englisch) Code (Deutsch) ACS880-01 Frequenzumrichter 9AKK105408A7004 ACS880-04 drive modules (200 to 710 kW, 300 to 700 hp) 9AKK105713A4819 ACS8

Cross Reference Application Information Input Reactors Resistors Powerohm ACS Drives ACB Drives Baldor DC Drives Analog AC Drives AC Vector Drives AC Inverter Drives AC Micro Drives ACB Part Numbers Baldor ACB & ACS Drives ACB 530 - U1 - 07A5 - 2 Voltage: 2 230V 4 460V 6 600V Rating: 07A5 7.5A Type: U1 ACB530 - Wall Mount PC ACB530 .

Health in Care Homes Version 2 March 2020 . page 1 The framework for Enhanced Health in Care Homes 2020/21 - Version 2 Publishing approval number: 001681 Version number: 2 First published: 31 March 2020 Prepared by: Community Services and Ageing Well Team This information can be made available in alternative formats, such as easy read or large print, and may be available in alternative .