MAKE YOUR WALKWAYS, DRIVEWAYSAND RAMPS WINTER SAFE!Prevent snow and ice accumulation

Does This Happen to Your Surfaces?SNOW AND ICE HINDERS SAFE ACCESSWhen snow and ice accumulates onsurfaces, safe access to and around abuilding becomes a risk. Can you risksafe and easy access to: Footpaths, walkways and stairs forhomes, public buildings, train stations Fire escape routes for apartmentbuildings, office buildings Driveways for homes Car park/garage ramps or access waysfor residential highrises, schools, officebuildings, airports Loading docks Emergency entrances for hospitalsRisk for damage, inconvenience andsafety hazard: Snow accumulation prevents safeaccess in and out of buildings, leading todelays and inconvenience. Personal injury from slipping or vehicleaccidents create liability risks for abuilding owner. Manual snow removal is physicallystrenuous, slow, costly, and impractical. Salting surfaces is not environmentallyideal, and salt being tracked into abuilding can cause structural and interiordamage.Our SolutionsPROTECT YOUR WALKWAYS, DRIVEWAYS, OR RAMPS WITH NVENT RAYCHEMHEATING SYSTEMS. PREVENT SNOW AND ICE FROM CAUSING ACCIDENTS,DELAYS OR COSTLY DAMAGE.MAKE YOUR SURFACES WINTER SAFE!ElectroMeltnVent RAYCHEM’S cut-to-length self-regulating heating cable solution reducesheat output automatically as the pavement warms, and is ideal for theseconditions/desired features: Small to moderate-sized concrete and paver surface areas Voltage: 208 V; 240 V; 277 V; 347 V Jacket: Rugged heating cables are protected by a tinned-copper braidencased in a 70-mil modified polyolefin outer jacket Control and sensor options: PD-Pro, GF-Pro, LCD-8, and SIT-6E. Advancedoptions include: Single or multi-circuit, integrated power distribution,energy monitoring, BMS communications Components: EMK heat shrinkable fittingsMIRAYCHEM’S MI pre-terminated heating cable solution provides higher voltages,higher output, 3-phase power option, and is ideal for these conditions/desiredfeatures: Large concrete, paver, and asphalt surface areas Voltage: 120 V to 600 V; Single or 3-Phase design Jacket: Rugged heating cables contain a copper sheath and a high-densitypolyethylene (HDPE) jacket Control and sensor options: PD-Pro, GF-Pro, LCD-8, and SIT-6E. Advancedoptions include: Single or multi-circuit, integrated power distribution,energy monitoring, BMS communications Components: n/a2 nVent.com

Surface Snow Melting System Estimate Form 2019 nVent. All nVent marks and logos are owned or licensed by nVent Services GmbH or its affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without notice. . H59871 1905Email completed form to your nVent Sales Rep for a complete Bill of Materials and quote!CHECK OUT SNOCALC, OUR ONLINE SURFACE SNOW MELTING DESIGN TOOL at www.nVentthermal.com by selecting the Commercial or Residential segment - Resources and clicking on the SnoCalc design tool.1. Building Type: House Small shop / strip mall High-rise residential /multi-use bldg. Commercial building 120 V 208 V 240 V 277 V 120 V 208 V 240 V 277 V 120 V 208 V 240 V 277 V 120 V 208 V 240 V 277 V2. Project City, State:3. Area Name:4. Voltage: 347 V 480 V 600 V 347 V 480 V 600 V 347 V 480 V 600 V 347 V 480 V 600 V5. Voltage Configuration: 1 Phase 1 Phase 1 Phase6. Breaker Size: 20 A 30 A 40 A 50 A 20 A 30 A 40 A 50 A 20 A 30 A 40 A 50 A 20 A 30 A 40 A 50 A 60 A 80 A 100 A 60 A 80 A 100 A 60 A 80 A 100 A 60 A 80 A 100 A Concrete Concrete Concrete Concrete Asphalt Asphalt Asphalt Asphalt Pavers Pavers Pavers Pavers Stairs (on grade) Stairs (on grade) Stairs (on grade) Stairs (on grade) Stairs (elevated) Stairs (elevated) Stairs (elevated) Stairs (elevated) Wheel Tracks (concrete) Wheel Tracks (concrete) Wheel Tracks (concrete) Wheel Tracks (concrete) Wheel Tracks (asphalt) Wheel Tracks (asphalt) Wheel Tracks (asphalt) Wheel Tracks (asphalt)9. Stair Width:ftftftft10. Stair Depth:inininin11. Riser Height:inininin12. Landing Area:sq ftsq ftsq ftsq ft13. Total Area(not including landing):sq ftsq ftsq ftsq ft15. F eet from Junction Boxto Slab:ftftftft16. J unction Box HeightAbove Grade:ftftftft17. I f Wheel Track Design,Length of Tracks:ftftftft18. Control: Control Only Control Only Control Only Control Only Control w/ Power Dist Control w/ Power Dist Control w/ Power Dist Control w/ Power Dist Yes Yes Yes Yes7. Area Type: 3 Phase 3 Phase 1 Phase 3 Phase 3 Phase8. Number of Steps:14. Number of ExpansionJoints:19. Controls Provide GFPD? No No No No20. Notes:21. Customer name:Company:BUSINESS CARDPhone:Email:Project name:nVent.com 3

PMPH & SMH System Estimate Form 2019 nVent. All nVent marks and logos are owned or licensed by nVent Services GmbH or its affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without notice. . H560675 1905Email completed form to your nVent Sales Rep for a complete Bill of Materials and quote!Need Quote For: PMPH SMHCHECK OUT SNOCALC, OUR ONLINE SURFACE SNOW MELTING DESIGN TOOL at www.nVentthermal.com by selecting the Commercial or Residential segment - Resources and clicking on the SnoCalc design tool.1. Building Type& Conditions:(check allthat apply) House Small shop / strip mall High-rise residential /multi-use Commercial building New Construction RetrofitAnnual Snow Fall less than 100 inches more than 100 inchesLength: InchesLength: InchesLength: InchesLength: InchesWidth: InchesWidth: InchesWidth: InchesWidth: InchesHeight: InchesHeight: InchesHeight: InchesHeight: Inches Dimensioned sketch Dimensioned sketch of Dimensioned sketch of Dimensioned sketch ofLength: ftLength: ftLength: ftLength: ftNumber of stairsNumber of stairsNumber of stairsNumber of stairsWidth: ftWidth: ftWidth: ftWidth: ftbldg.2. Area Name:3. Pavers:4. Paved Area:of heated area or EstimatedWidth: ft5. Stairs orPlatforms:heated area or EstimatedWidth: ftheated area or EstimatedWidth: ftheated area or EstimatedWidth: ftLength: ftLength: ftLength: ftLength: ft6. Voltage: 120 V 208 V 240 V 277 V 120 V 208 V 240 V 277 V 120 V 208 V 240 V 277 V 120 V 208 V 240 V 277 V7. Circuit BreakerSize: 15 A 20 A 30 A 15 A 20 A 30 A 15 A 20 A 30 A 15 A 20 A 30 A8. Controllers: Ambient Temperature Only Ambient Temperature Only Ambient Temperature Only Ambient Temperature Only Snow and ice melting controller Snow and ice melting controller Snow and ice melting controller Snow and ice melting controller Snow Sensor Snow Sensor Snow Sensor Snow Sensor9. Notes:10. Customer name:Company:Phone:Email:Project name:Project location:4 nVent.comBUSINESS CARD

North AmericaTel 1.800.545.6258Fax 1.800.527.5703thermal.info@nvent.comOur powerful portfolio of com/RAYCHEM 2019 nVent. All nVent marks and logos are owned or licensed by nVent Services GmbH or its affiliates. All other trademarks are the property of their respective owners. nVent reserves the right tochange specifications without Worksheet-EN-1905

SNOW AND ICE HINDERS SAFE ACCESS ElectroMelt nVent RAYCHEM’S cut-to-length self-regulating heating cable solution reduces heat output automatically as the pavement warms, and is ideal for these conditions/desired features: Small to moderate-sized concrete and paver surface areas Voltage: 208 V; 240 V; 277 V; 347 V

Related Documents:

This is a request for three driveway curb cuts. There are two existing driveways. This site is 790’ long allowing two driveways. A third driveway needs to be added to serve the proposed new building. There is not a connection from one of the existing driveways to the new building location

Belden Aqua-Bric Simplifies maintenance in climates with ice and snow Are used as : walkways, driveways, parking lots, commercial vehicular entry ways and any number of vehicular and pedestrian uses Belden Brick Aqua-Bric pavers serve as the wearing surface for the pavement. These are brick units fired in a kiln to develop necessary strength, absorption and durability properties.

There should be lines of clear sight from driver’s eye height to driver’s eye height, i.e. 1.15 metres above ground level, along the lines detailed below and shown in Figure 2. Lines AC and BD - All driveways, all roads. Lines EC and ED (no permanent obstructions, exclude parked vehicles which may obstruct these sight lines .

Driveway construction 39 Dimensions of driveways 39 Levels and grades of driveways 39 Driveway pavement composition 40 Low impact paving 40 . to the Engineering Development Design Guidelines include: Advocate for increased stormwater harvesting and greywater re-use by households and businesses.

Pothole Patch Easy-to-apply SealBest Pothole Patch is an All-Weather Pothole Patch designed for filling potholes and depressions in driveways, parking lots, roads, and other pavement surfaces. It can be used in both wet and dry conditions. For Driveways, Parking Lots, Roads, & other Pavement Surfaces. Features Works in Wet or Dry Conditions

10 Year Buildmark Warranty. External Specification External walls of traditional construction in natural stone and ‘colour-through’ render. Roof tiles from the forticrete range in grey. Tarmacadam to private driveways. Shared driveways to be block paved (Plots 2 & 3 only). Windows and external glazed frames to be low maintenance PVCu in white.

Access Management Guidelines 6 Driveway Control s the title suggests, some of the most important techniques in access management relate to control of driveways. Tools are available to eliminate, minimize, restrict, design and locate. Limit Driveway Connections Private individual residential driveways should only intersect with local streets and

dispenser control, car wash control, and fast food transactions. Like the Ruby SuperSystem and the Topaz, the Ruby2 accepts and processes all payment options, including cash, checks, credit and debit cards, coupons, and various prepaid cards. The Ruby2 has a 15-inch touch screen and a color display. Online help is