PRODUCT INFORMATION OTICON ALTA PRO OTICON ALTA

2y ago
31 Views
2 Downloads
1.10 MB
23 Pages
Last View : Today
Last Download : 5m ago
Upload by : Victor Nelms
Transcription

PRODUCT INFORMATIONOTICON ALTA PROOTICON ALTAOticon Alta is built on the Inium platform and is our best performinghearing solution with our most advanced technologies. The audiology inAlta provides its users premium listening performance and allows tofactoring in individual listening preferences and needs of each client.FITTING RANGE-100102030405060708090100110120The Alta family styles range from compact In-the-Ear styles to a broad paletteof Behind-the-Ear styles. The style range include the new wireless Invisible-Inthe-Canal (IIC), Completely-In-the-Canal (CIC) and the new designRITE for userslooking for ultimate discretion. The RITE instruments use Oticon’s miniFitreceivers and the BTE instruments use the new Corda miniFit thin tubes,allowing sharing the miniFit soft domes and custom ear pieces.dB HL125 250 500 1k2k4k8k HzOticon Alta can be fitted to users with mild to severe-to-profound hearing losses.Speech Guard EInium feedback shieldFamily FeaturesSpeech Guard is a signal processingsystem that preserves speech dynamics and speech patterns as these areimportant and essential information tothe auditory system. Speech Guard Eis optimised to better line up with thedynamic range of speech to preservemore of the speech cues.Inium feedback shield is an effectivefeedback protection system implemented on the Oticon Inium platform.Inium feedback shield is a hybrid systemcombining two anti-feedback principlesto both prevent and suppress feedbackwithout superimposing artefacts ontothe signal quality or sacrificing audibility.Speech Guard E maintains audibility,prevents discomfort and safeguardsspeech envelopes by combining theadvantages of both fast and slowacting compression.Based on the environment, the systemdeploys the best combination of real timephase inversion and frequency shift todeliver great sound quality at all times. YouMatic PremiumYouMatic is a personal automatic systemprogrammed to the client’s individualneeds and sound preferences. YouMaticcontrols the sound processing acrossmultiple environments by adjustingthe response, directionality, noisemanagement, transient managementand compression.INIUMWIRELESS Speech Guard ESpatial Sound PremiumYouMatic PremiumBinaural ProcessingBinaural SynchronisationBinaural PB CoordinationSpatial Noise ManagementFitting Bandwidth 10 kHzInium feedback shieldFree Focus PremiumArtificial Intelligence Premium [ ]LearningMemoryT-coilAutoPhone ProgramPower Bass (streaming)Music Widening (streaming)TriState Noise ManagementTransient ManagementMulti-band Adaptive DirectionalityVoice Aligned Compression (VAC)NAL-NL1, NAL-NL2 andDSL v5.0a m[i/o]Flexible miniFit receiver systemConnectLine and Remote ControlDAI input and FM optionIn-situ audiometry (Genie)

PRODUCT OVERVIEWRITE STYLESCUSTOM STYLESBTE STYLES8-100102030405060708090100110120dB HL125 250 500 1k2k4k8k Hz-100102030405060708090100110120dB HL125 250 500 1k2k4k8k Hz-100102030405060708090100110120dB HL125 250 500 1k2k4k8k Hz-100102030405060708090100110120dB HL125 250 500 1k2k4k8k Hz-100102030405060708090100110120dB HL125 250 500 1k2k4k8k Hz-100102030405060708090100110120dB HL125 250 500 1k2k4k8k Hz-100102030405060708090100110120MouldBass & Power domeOSPL90 (peak)Full-on gain (peak)dB HL125 250 500 1k2k4k8k Hz-100102030405060708090100110120dB HL125 250 500 1k2k4k8k Hz-100102030405060708090100110120dB HL125 250 500 1kOpen dome2k4k8k Hz-100102030405060708090100110120Custom moulddB HL125 250 500 1k2k4k8k HzCorda miniFitEar simulator119 dB SPL126 dB SPL130 dB SPL135 dB SPL127 dB SPL115 dB SPL127 dB SPL132 dB SPL131 dB SPL126 dB SPL 135 dB SPL2cc coupler109 dB SPL117 dB SPL121 dB SPL127 dB SPL117 dB SPL105 dB SPL118 dB SPL124 dB SPL121 dB SPL117 dB SPL 126 dB SPLEar simulator49 dB59 dB64 dB71 dB62 dB46 dB65 dB66 dB62 dB61 dB68 dB2cc coupler38 dB50 dB54 dB62 dB53 dB35 dB55 dB57 dB53 dB51 dB60 dBIICCICITCITE - Half ShellITE - Full ShellBattery size1031213Fitting 2138Battery life (h)*10075-135140-25065-7580-11080-110115-14085-190 ** Program control *** Volume control *** Telecoil AutoPhone Connectline compatible FlexConnect MiniFlexConnect MiniWirelessDirectional Cable #3 directlyFlexConnectProgramming shoeCable #3 directlyProgramming shoeFM compatible Programming interface, cable #3FlexConnect MiniCUSTOM STYLESWax protection Receiver in all instrumentsProWaxMicrophone in 10 battery instrumentsT-CapMicrophone in 312 and 13 battery instrumentsO-CapInstruments with 312 battery may be produced with horizontal battery drawerdepending on ear geometry.Oticon optimises fitting level and venting by default according to hearing loss,requested instrument style, and ear geometry. DefaultOption*Real usage battery life is shownas an estimated interval basedon measurements with variableamplification settings andvariable input levels.** IIC is only available in Alta Pro*** Option available for CIC onlyACCESSORIES FITTING LEVELSCustom RITEAccessoriesType/infoUse withTamper resistantbattery drawerAvailable in 7 coloursminiRITE, RITE,miniBTE, BTE13DAI adaptorAP900BTE13 and RITEDedicatedFM receiverAmigo R12BTE13 and RITEFM adaptorFM 9Compatible with Amigo R2and other universal receiversBTE13BTE70 dB890 dB110 dB23

PRODUCT OVERVIEWGENERAL FITTINGOticon Alta instruments are programmed using the Genie 2014.2fitting software or higher compatible with NOAH 3 or higher.Wireless fitting - FittingLINKFittingLINK provides a wireless link (Bluetooth) between the PCand one or two wireless enabled hearing instruments. In additionFittingLINK can be used via a USB cable connected to the PC.Wireless fitting - nEARcomnEARcom provides a wireless link between NOAHlink andone or two wireless enabled hearing instruments. In additionnEARcom provides a pass-through connection to accommodateprogramming cables and replaces the existing NOAHlink neck loop.nEARcom uses TM#1.Cabled fittingUse programming cable #3.miniRITE & RITEReceiver unitMust use miniFit receivers.Receiver wireSelect between three receiver typeswith different output performance,labeled according to fitting capabilities:60, 85 and 100.60, 85100lengths 0–5lengths 1–5Receiver connector Type C1 (marked on packaging).to instrumentProWax miniFitminiFit receivers 60, 85 and 100ProWaxPower Flex mouldMicro mouldLiteTipdesignRITEReceiver unitBTE STYLESMust use miniFIT 80 receiwer availablein lengths 1-5.Receiver connector Type C3 (marked on packaging).to instrumentsProWax miniFitminiFit receiver 80ProWaxMicro mouldLiteTipSeparate wires connect Power Flexmoulds (100) to RITE instruments,available in lengths 1–5.Sound hookInterchangeable standard and child hook.DamperDamping plug available for BTE13 85.Thin tubesCorda miniFit (0.9 mm tube)for miniBTE 85 and BTE13 85.Corda miniFit Power (1.3 mm tube)for BTE13 100.Thin tubes are available in lengths -1–4.Style specific adapters must be usedwhen connecting thin tubes.ProWaxMicro mouldLiteTipRITE & BTE STYLESEar piecesAll miniFit receivers and Corda miniFit tubesmust use miniFit ear pieces.TypeOpen domePower domeBass dome, single ventBass dome, double vent4Sizes6, 8, 10 mm6, 8, 10, 12 mm6, 8, 10, 12 mm6, 8, 10, 12 mmLiteTip and Micro mould (requires taking an impression).

FeaturesOticon Alta ProOticon AltaFitting formulasVAC, NAL, DSLVAC, NAL, DSLSpeech Guard EYesYesSpatial SoundPremiumNoYouMaticPremiumPremiumBinaural Processing (compression)YesNoBinaural Synchronisation (automatics)YesYesBinaural Coordination (PB operations)YesYesSpatial Noise ManagementYesNoTransient ManagementYesYesFitting Bandwidth*Free Focus10 kHz10 kHzPremiumPremiumInium feedback shieldYesYesArtificial IntelligencePremium [ ]Premium [ ]Power BassYesYesMusic WideningYesYesLearningYesYesFitting Bands1010Frequency channels1616*) Bandwidth accessible for gain adjustments during fittingCOLOUR SELECTIONRITE & BTE STYLES90Chroma Beige94Terracotta93Chestnut Brown44Silver919269Silver GreySteel Grey63Diamond BlackADDITIONAL designRITE COLOURS99Pale Lime95Vivid Lilac667368030405Mother of PearlCarbernet RedMidnight BlueSunset OrangeCUSTOM STYLES01Beige02Light BrownMedium BrownDark BrownBlackIIC & CIC onlyPOWER FLEX MOULDS01Beige02Light Brown03Medium Brown04Dark Brown05Black06Transparent5

CUSTOM 75 (IIC ONLY)OTICON ALTA PROEAR SIMULATOR2CC COUPLERMeasured according toANSI S3.22 (2003) and S3.7 (1995),IEC 60118-7 (2005) and IEC 60318-5 (2006).OSPL9012011010090100Hz50010002000 Hz500010000Full-on GaindBHz50010002000 Hz5000100009080701002000 Hz2010100200Hz50010002000 Hz500010000200Hz50010002000 Hz5000100908070100200Hz50010002000 Hz109 dB SPL103 dB SPLAverage109 dB SPL103 dB SPLPeak45 dB35 dB1600 Hz41 dB33 dBAverage40 dB34 dB--100-9600 Hz100-8500 Hz1 mA/m field--10 mA/m field--SPLITS L/R--500 Hz 2 %2%800 Hz 2 % 2 %1600 Hz 2 % 2 %21 dB SPL18 dB SPL--Quiescent0.7 mA0.7 mATypical0.7 mA0.7 mA5000135800/1400/2000 MHz: 16/16/ 9 dB SPL* Based on the standardised battery consumption measurement (IIC 60118-0.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environmentNote: For custom instruments, the maximum gain is customised for optimal size and performance.610000Frequency ResponsedB SPLSize: 10 (IEC PR70)IRIL (IEC 60118-13-2011)1000030111 dB SPLOmni5000Full-on Gain121 dB SPLDirBattery life, calculated, hours*1000PeakFrequency rangeBattery consumption5001600 HzReference test gainEquivalent input noise level (A)HzdBFrequency Response100(Input 70 dB SPL)200P084 Intiga i 10 2cc FOG 02 01 2012 str lo 11:02:23200dB SPLTotal harmonic distortion10010000P084 Intiga i 10 2cc FRESP 02 01 2012 str lo 11:04:5830100Telecoil output (1600 Hz)904010Full-on gain1004020OSPL90110Alta Pro IIC FOG 711 S 14 10 2013 kbn tjn 16:33:32Technical informationAll measurements are made on instrumentswith ProWax receiver and T-Cap microphoneprotection.200120Alta Pro IIC Freq60db 711 S 14 10 2013 kbn tjn 16:32:51Scale 1:1OSPL90dB SPLP084 Intiga i 10 711 OSPL90 17 11 2011 str lo 09:34:08dB SPLP084 Intiga i 10 2cc OSPL90 21 11 2011 str lo 13:25:28Measured according toIEC 60118-0 (1983) and 60711 (1981)and DIN 45605.

CUSTOM 75OTICON ALTA PROOTICON ALTAEAR SIMULATOR2CC COUPLERMeasured according toANSI S3.22 (2003) and S3.7 (1995),IEC 60118-7 (2005) and IEC 60318-5 (2006).10080100Hz50010002000 Hz500010000Full-on GaindB40303020100200Hz50010002000 Hz50001000090200Hz50010002000 HzAcoustic input: 60 dB SPLMagnetic input: 31.6 mA/m2000 Hz200Hz50010002000 Hz100200Hz50010002000 HzAverage110 dB SPL105 dB SPLPeak49 dB38 dB1600 Hz43 dB35 dBAverage41 dB35 dB36 dB27 dB100-9500 Hz100-8500 Hz1 mA/m field73 dB SPL-10 mA/m field93 dB SPL--82/82 dB SPL2.0 % 2 %800 Hz2.0 % 2 %1600 Hz3.0 %2.0 %Omni22 dB SPL20 dB SPLDir31 dB SPL29 dB SPLQuiescent1.0 mA1.0 mATypical1.0 mA1.0 mABattery life, calculated, hours*5000Acoustic input: 60 dB SPLMagnetic input: 31.6 mA/m109 dB SPLEquivalent input noise level (A)1000070104 dB SPL500 Hz500080112 dB SPLSPLITS L/R10000Frequency Response119 dB SPLFrequency range5000Full-on GainPeakReference test gainBattery consumption1000010001600 HzFull-on gain(Input 70 dB SPL)5000500dB SPL100100Total harmonic distortion1009070Hz101008020020Frequency ResponsedB SPLTelecoil output (1600 Hz)1004010OSPL9080dBFOG 711 ITC75 05 10 2012 str lo 13:44:12Technical informationAll measurements are made on instrumentswith ProWax and T-Cap or O-Cap protection.Omnidirectional mode is used unlessotherwise stated.200MT 711 ITC 75 05 10 2012 str lo 11:48:42Scale 1:190MPO 2cc ITC75 05 10 2012 str lo 11:42:45110100MPO 711 ITC75 05 10 2012 str lo 11:43:0811090OSPL90dB SPLFOG 2CC ITC75t 05 10 2012 str lo 11:39:10OSPL90dB SPL10000MT 2cc ITC 75 05 10 2012 str lo 11:49:57Measured according toIEC 60118-0 (1983) and 60711 (1981)and DIN 45605.135/140/260Size: 10 (IEC PR70) / 312 (IEC PR41) / 13 (IEC PR48)IRIL (IEC 60118-13-2011)800/1400/2000 MHz: 28/44/37 dB SPLIRIL (IEC 60118-13-2011) for IIC and CIC800/1400/2000 MHz: 17/33/26 dB SPL* Based on the standardised battery consumption measurement (IIC 60118-0.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environmentNote: For custom instruments, the maximum gain is customised for optimal size and performance.7

CUSTOM 85OTICON ALTA PROOTICON ALTAEAR SIMULATOR2CC COUPLERMeasured according toANSI S3.22 (2003) and S3.7 (1995),IEC 60118-7 (2005) and IEC 60318-5 (2006).11090100Hz50010002000 Hz500010000Full-on GaindB50404030100200Hz50010002000 Hz500010000100200Hz50010002000 HzAcoustic input: 60 dB SPLMagnetic input: 31.6 mA/m2000 Hz200Hz50010002000 Hz100200Hz50010002000 Hz111 dB SPL113 dB SPL117 dB SPLPeak59 dB50 dB1600 Hz51 dB43 dBAverage50 dB45 dB44 dB37 dB100-9600 Hz100-8000 Hz1 mA/m field81 dB SPL-10 mA/m field101 dB SPL--90/90 dB SPL2.0 % 2 %800 Hz2.0 % 2 %1600 Hz3.0 %2.0 %Omni22 dB SPL19 dB SPLDir32 dB SPL29 dB SPLQuiescent1.0 mA1.0 mATypical1.0 mA1.0 mABattery life, calculated, hours*5000Acoustic input: 60 dB SPLMagnetic input: 31.6 mA/m117 dB SPLEquivalent input noise level (A)125/140/260Size: 10 (IEC PR70) / 312 (IEC PR41) / 13 (IEC PR48)81000080Average500 Hz500090119 dB SPLSPLITS L / R10000Frequency Response126 dB SPLFrequency range5000Full-on GainPeakReference test gainBattery consumption1000010001600 HzFull-on gain(Input 70 dB SPL)5000500dB SPL110100Total harmonic distortion10010080Hz201109020030Frequency ResponsedB SPLTelecoil output (1600 Hz)1005020OSPL9090dBFOG 711 ITC 85 05 10 2012 str lo 11:57:25Technical informationAll measurements are made on instrumentswith ProWax and T-Cap or O-Cap protection.Omnidirectional mode is used unlessotherwise stated.200MT 711 ITC 85 05 10 2012 str lo 11:54:52Scale 1:1100MPO 2cc ITC 85 05 10 2012 str lo 11:56:35120110MPO 711 ITC 85 05 10 2012 str lo 11:56:06120100OSPL90dB SPLFOG 2cc ITC 85 05 10 2012 str lo 11:57:54OSPL90dB SPLIRIL (IEC 60118-13-2011)800/1400/2000 MHz: 21/39/ 14 dB SPLIRIL (IEC 60118-13-2011) for IIC and CIC800/1400/2000 MHz: 20/26/29 dB SPL* Based on the standardised battery consumption measurement (IIC 60118-0.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environmentNote: For custom instruments, the maximum gain is customised for optimal size and performance.10000MT 2cc ITC 85 05 10 2012 str lo 11:55:28Measured according toIEC 60118-0 (1983) and 60711 (1981)and DIN 45605.

CUSTOM 90OTICON ALTA PROOTICON ALTAEAR SIMULATOR2CC COUPLERMeasured according toANSI S3.22 (2003) and S3.7 (1995),IEC 60118-7 (2005) and IEC 60318-5 (2006).120100100Hz50010002000 Hz500010000Full-on GaindB505040200Hz50010002000 Hz5000100001001101009080Hz50010002000 HzAcoustic input: 60 dB SPLMagnetic input: 31.6 mA/m500050010002000 Hz10000200Hz50010002000 Hz100200Hz50010002000 Hz123 dB SPL115 dB SPLAverage121 dB SPL116 dB SPL54 dBPeak64 dB56 dB47 dBAverage54 dB49 dB48 dB40 dB100-8500 Hz1 mA/m field85 dB SPL-10 mA/m field105 dB SPL--93/93 dB SPL 2 % 2 %(Input 70 dB SPL)Equivalent input noise level (A)Battery consumptionBattery life, calculated, hours*10000121 dB SPL1600 Hz500 Hz5000Acoustic input: 60 dB SPLMagnetic input: 31.6 mA/m100-8700 HzTotal harmonic distortion1000080130 dB SPLSPLITS L/R500090PeakFrequency range10000Frequency Response1600 HzReference test gain5000Full-on GaindB SPL100200Hz3011010020040Frequency ResponsedB SPLTelecoil output (1600 Hz)FOG 711 ITC 90 05 10 2012 str lo 13:28:3760100Full-on gain1006030OSPL90100dBMT 711 ITC 90 05 10 2012 str lo 13:30:09Technical informationAll measurements are made on instrumentswith ProWax and O-Cap protection.Omnidirectional mode is used unlessotherwise stated.200110MPO 2cc ITC 90 05 10 2012 str lo 13:27:43130120MPO 711 ITC 90 05 10 2012 str lo 13:24:33130110Scale 1:1OSPL90dB SPLFOG 2cc ITC 90 05 10 2012 str lo 13:29:14OSPL90dB SPLMT 2cc ITC 90 05 10 2012 str lo 13:31:01Measured according toIEC 60118-0 (1983) and 60711 (1981)and DIN 45605.800 Hz 2 % 2 %1600 Hz3.0 %2.0 %Omni23 dB SPL19 dB SPLDir34 dB SPL29 dB SPLQuiescent1.0 mA1.0 mATypical1.0 mA1.0 mA140/260Size: 312 (IEC PR41) / 13 (IEC PR48)IRIL (IEC 60118-13-2011)800/1400/2000 MHz: 26/55/41 dB SPL* Based on the standardised battery consumption measurement (IIC 60118-0.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environmentNote: For custom instruments, the maximum gain is customised for optimal size and performance.9

CUSTOM 100OTICON ALTA PROOTICON ALTAEAR SIMULATOR2CC COUPLERMeasured according toIEC 60118-0 (1983) and 60711 (1981)and DIN 45605.Measured according toANSI S3.22 (2003) and S3.7 (1995),IEC 60118-7 (2005) and IEC 60318-5 (2006).OSPL90dB SPL110100100Hz50010002000 Hz500010000Full-on GaindBHz50010002000 Hz50200Hz50010002000 Hz500010000Full-on Gain5040100200Hz50010002000 Hz200Hz50010002000 Hz50001000011010090100200Hz50010002000 HzPeak135 dB SPL1600 Hz135 dB SPL127 dB SPLAverage130 dB SPL123 dB SPL62 dB127 dB SPLPeak71 dB1600 Hz67 dB59 dBAverage65 dB58 dB60 dB48 dB100-8000 Hz1 mA/m field95 dB SPL-10 mA/m field115 dB SPL--105/105 dB SPL 2 % 2 %800 Hz 2 % 2 %1600 Hz2.0 % 2 %Omni17 dB SPL15 dB SPLDir(Input 70 dB SPL)Equivalent input noise level (A)Battery consumptionBattery life, calculated, hours*500 Hz5000Acoustic input: 60 dB SPLMagnetic input: 31.6 mA/m27 dB SPL26 dB SPLQuiescent0.9 mA0.9 mATypical0.9 mA0.9 mA155/290Size: 312 (IEC PR41) / 13 (IEC PR48)IRIL (IEC 60118-13-2011)800/1400/2000 MHz: 15/45/28 dB SPL* Based on the standardised battery consumption measurement (IIC 60118-0.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environmentNote: For custom instruments, the maximum gain is customised for optimal size and performance.1010000Alta ITE 100 MT 2cc 30 08 2013 str lo 14:28:2390Alta ITE 100 MT 711 30 08 2013 str lo 14:27:48100100-8175 HzTotal harmonic distortion10000120110SPLITS L / R5000Frequency ResponsedB SPL120Frequency range1000060Frequency ResponsedB SPLReference test gain5000Alta ITE 100 FOG 2cc 30 08 2013 str lo 14:30:5760Acoustic input: 60 dB SPLMagnetic input: 31.6 mA/mTelecoil output (1600 Hz)20070100Full-on gain10070100OSPL90100dB40Warning to the instrument dispenserThe maximum output capability ofthe hearing instrument may exceed132 dB SPL (IEC 711). Special care shouldbe exercised in selecting and fittingthe instrument as there may be risk ofimpairing the remaining hearing of thehearing instrument user.110ALTA ITE 100 FOG 711 30 08 2013 str lo 14:30:32Technical informationAll measurements are made on instrumentswith ProWax and O-Cap protection.Omnidirectional mode is used unlessotherwise stated.200120Alta ITE 100 MPO 2cc 30 08 2013 str lo 14:26:44130120Alta MPO ITE 100 711 30 08 2013 str lo 14:24:18130Scale 1:1OSPL90dB SPL

designRITE 80OTICON ALTA PROEAR SIMULATOR2CC COUPLERMeasured according toANSI S3.22 (2003) and S3.7 (1995),IEC 60118-7 (2005) and IEC 60318-5 (2006).OSPL90dB SPL12011011090100Hz50010002000 Hz500010000Full-on GaindB90100200Hz50010002000 Hz10000Full-on GaindB60504030200Hz50010002000 Hz5000100004030100Frequency ResponsedB SPL110100908010050200Hz50010002000 Hz500010000200Hz50010002000 Hz500010000Frequency ResponsedB SPLFrequency responce designRITE 711 02 04 2014 kbn tjn 15:27:47100Alta designRITE FOG 711 02 04 2014 kbn tjn 13:53:136050001101009080100Alta FOG 2cc 31 03 2014 kbn tjn 14:41:14Technical informationOmnidirectional mode is used unlessotherwise stated.200100200Hz50010002000 Hz500010000Alta Frequency response 2CC 02 04 2014 kbn tjn 15:28:09Scale 1:1Alta MPO 711 31 03 2014 kbn tjn 14:42:29120100OSPL90dB SPLAlta MPO 2cc 31 03 2014 kbn tjn 14:42:57Measured according toIEC 60118-0 (1983) and 60711 (1981)and DIN 45605.8OSPL90Full-on gainPeak127 dB SPL117 dB SPL1600 Hz120 dB SPL112 dB SPLAverage117 dB SPL111 dB SPLPeak62 dB53 dB1600 Hz53 dB44 dBAverage50 dB47 dBReference test gainFrequency rangeTelecoil output (1600 Hz)Total harmonic distortion(Input 70 dB SPL)Equivalent input noise level (A)Battery consumptionBattery life, calculated, hours*45 dB34 dB100-9300 Hz100-7500 Hz1 mA/m field--10 mA/m field--SPLITS L/R--500 Hz 2 % 2 %800 Hz 2 % 2 %1600 Hz 2 % 2 %Omni21 dB SPL17 dB SPLDir33 dB SPL30 dB SPLQuiescent1.0 mA1.0 mATypical1.3 mA1.3 mA90Size: 10 (IEC PR70)IRIL (IEC 60118-13-2011)800/1400/2000 MHz: 17 dB SPL* Based on the standardised battery consumption measurement (IIC 60118-0.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment11

miniRITE 60OTICON ALTA PROOTICON ALTAEAR SIMULATOR2CC COUPLERMeasured according toANSI S3.22 (2003) and S3.7 (1995),IEC 60118-7 (2005) and IEC 60318-5 (2006).10080100Hz50010002000 Hz500010000Full-on GaindB40303010100200Hz50010002000 Hz50001000080(Input 70 dB SPL)Equivalent input noise level (A)Battery consumptionBattery life, calculated, hours*50010002000 Hz500010000200Hz50010002000 Hz5000500060100200Hz50010002000 Hz115 dB SPL110 dB SPL101 dB SPLAverage108 dB SPL103 dB SPL5000105 dB SPLPeak46 dB35 dB1600 Hz37 dB29 dBAverage34 dB30 dB30 dB26 dB100-9500 Hz100-8300 Hz1 mA/m field--10 mA/m field--SPLITS L/R--500 Hz 2 % 2 %800 Hz 2 % 2 %1600 Hz 2 % 2 %Omni21 dB SPL16 dB SPLDir29 dB SPL24 dB SPLQuiescent1.0 mA1.0 mATypical1.1 mA1.3 mA130800/1400/2000 MHz: 43/26/18 dB SPL* Based on the standardised battery consumption measurement (IIC 60118-0.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment121000070Size 312 (IEC PR41)IRIL (IEC 60118-13-2011)10000Frequency ResponsePeakFrequency rangeTotal harmonic distortionHz2000 Hz1600 HzReference test gainTelecoil output (1600 Hz)2001000Full-on GaindB SPL90100Full-on gain1008060500109070Hz20Frequency ResponsedB SPL200dB4020OSPL90100mRiteS FOG 711 29 08 2012 str lo 16:23:55Technical informationOmnidirectional mode is used unlessotherwise stated.20080mRiteS RTG 711 12 09 2012 str lo 08:31:12Scale 1:190mRiteS MPO 2cc 29 08 2012 str lo 15:46:01110100mRiteS MPO 711 29 08 2012 str lo 15:45:2611090OSPL90dB SPLmRiteS FOG 2cc 29 08 2012 str lo 16:24:26OSPL90dB SPL10000mRiteS RTG 2cc 12 09 2012 str lo 08:31:38Measured according toIEC 60118-0 (1983) and 60711 (1981)and DIN 45605.

miniRITE 85OTICON ALTA PROOTICON ALTAEAR SIMULATOR2CC COUPLERMeasured according toANSI S3.22 (2003) and S3.7 (1995),IEC 60118-7 (2005) and IEC 60318-5 (2006).11090100Hz50010002000 Hz500010000Full-on GaindB60505030100200Hz50010002000 Hz500010000100(Input 70 dB SPL)Equivalent input noise level (A)Battery consumptionBattery life, calculated, hours*50010002000 Hz500010000200Hz50010002000 Hz500010000500010000Frequency Response9080100200Hz50010002000 HzPeak127 dB SPL118 dB SPL123 dB SPL114 dB SPLAverage119 dB SPL114 dB SPLPeak65 dB55 dB1600 Hz51 dB43 dBAverage52 dB47 dBFrequency rangeTotal harmonic distortionHz2000 Hz1600 HzReference test gainTelecoil output (1600 Hz)2001000Full-on GaindB SPL110100Full-on gain100100805003011090Hz40Frequency ResponsedB SPL200dB6040OSPL90100mRiteM FOG 711 29 08 2012 str lo 16:25:51Technical informationOmnidirectional mode is used unlessotherwise stated.20090mRiteM RTG 711 29 08 2012 str lo 16:19:35Scale 1:1100mRiteM MPO 2cc 29 08 2012 str lo 15:40:54120110mRiteM MPO 711 29 08 2012 str lo 15:41:44120100OSPL90dB SPLmRiteM FOG 2cc 29 08 2012 str lo 16:26:43OSPL90dB SPL44 dB38 dB100-9500 Hz100-8700 Hz1 mA/m field--10 mA/m field--SPLITS L/R--500 Hz 2 % 2 %800 Hz2.4 % 2 %1600 Hz 2 % 2 %Omni25 dB SPL18 dB SPLDir33 dB SPL25 dB SPLQuiescent1.0 mA1.0 mATypical1.1 mA1.2 mA500010000mRiteM RTG 2cc 29 08 2012 str lo 16:20:12Measured according toIEC 60118-0 (1983) and 60711 (1981)and DIN 45605.130Size 312 (IEC PR41)IRIL (IEC 60118-13-2011)800/1400/2000 MHz: 45/30/25 dB SPL* Based on the standardised battery consumption measurement (IIC 60118-0.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment13

miniRITE 100OTICON ALTA PROOTICON ALTAEAR SIMULATOR2CC COUPLERMeasured according toANSI S3.22 (2003) and S3.7 (1995),IEC 60118-7 (2005) and IEC 60318-5 (2006).120100100Hz50010002000 Hz500010000Full-on GaindB60505030100200Hz50010002000 Hz500010000100Full-on gain(Input 70 dB SPL)Equivalent input noise level (A)Battery consumptionBattery life, calculated, hours*50010002000 Hz500010000200Hz50010002000 Hz5000500080100200Hz50010002000 Hz132 dB SPL124 dB SPL131 dB SPL124 dB SPLAverage126 dB SPL121 dB SPLPeak66 dB57 dB1600 Hz56 dB49 dBAverage58 dB52 dB50 dB44 dB100-8700 Hz100-8100 Hz1 mA/m field--10 mA/m field--SPLITS L/R--500 Hz2.5 % 2 %800 Hz 2 % 2 %1600 Hz 2 % 2 %Omni22 dB SPL16 dB SPLDir30 dB SPL25 dB SPLQuiescent1.0 mA1.0 mATypical1.1 mA1.3 mA5000130800/1400/2000 MHz: 46/28/23 dB SPL* Based on the standardised battery consumption measurement (IIC 60118-0.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment141000090Size 312 (IEC PR41)IRIL (IEC 60118-13-2011)10000Frequency ResponsePeakFrequency rangeTotal harmonic distortionHz2000 Hz1600 HzReference test gainTelecoil output (1600 Hz)2001000Full-on GaindB SPL110100OSPL90100100805003011090Hz40Frequency ResponsedB SPL200dB6040Warning to the instrument dispenserThe maximum output capability ofthe hearing instrument may exceed132 dB SPL (IEC 711). Special care shouldbe exercised in selecting and fittingthe instrument as there may be risk ofimpairing the remaining hearing of thehearing instrument user.100mRiteP FOG 711 29 08 2012 str lo 16:27:33Technical informationOmnidirectional mode is used unlessotherwise stated.200100mRiteP RTG 711 29 08 2012 str lo 16:21:14Scale 1:1110mRiteP MPO 2cc 29 08 2012 str lo 15:50:28130120mRiteP MPO 711 29 08 2012 str lo 15:49:32130110OSPL90dB SPLmRiteP FOG 2cc 29 08 2012 str lo 16:28:08OSPL90dB SPL10000mRiteP RTG 2cc 29 08 2012 str lo 16:21:53Measured according toIEC 60118-0 (1983) and 60711 (1981)and DIN 45605.

RITE 60OTICON ALTA PROOTICON ALTAEAR SIMULATOR2CC COUPLERMeasured according toANSI S3.22 (2003) and S3.7 (1995),IEC 60118-7 (2005) and IEC 60318-5 (2006).10080100Hz50010002000 Hz500010000Full-on GaindB40303010100200Hz50010002000 Hz50001000080200Hz50010002000 HzAcoustic input: 60 dB SPLMagnetic input: 31.6 mA/mEquivalent input noise level (A)Battery consumptionBattery life, calculated, hours*Hz50010002000 Hz500010000500010000Frequency Response7060100200Hz50010002000 Hz5000Acoustic input: 60 dB SPLMagnetic input: 31.6 mA/m115 dB SPL110 dB SPL101 dB SPLAverage108 dB SPL103 dB SPL10000105 dB SPLPeak46 dB35 dB1600 Hz37 dB29 dBAverage34 dB30 dB30 dB26 dB100-9500 Hz100-8300 Hz1 mA/m field65 dB SPL-10 mA/m field85 dB SPL--82/82 dB SPL500 Hz 2 % 2 %800 Hz 2 % 2 %1600 Hz 2 % 2 %Omni21 dB SPL16 dB SPLDirSPLITS L/R(Input 70 dB SPL)200PeakFrequency rangeTotal harmonic distortion100002000 Hz1600 HzReference test gainTelecoil output (1600 Hz)50001000Full-on GaindB SPL90100Full-on gain1008060500109070Hz20Frequency ResponsedB SPL200dB4020OSPL90100mRiteS FOG 711 29 08 2012 str lo 16:23:55Technical informationOmnidirectional mode is used unlessotherwise stated.20080RiteS MT 711 12 09 2012 str lo 08:35:07Scale 1:190mRiteS MPO 2cc 29 08 2012 str lo 15:46:01110100mRiteS MPO 711 29 08 2012 str lo 15:45:2611090OSPL90dB SPLmRiteS FOG 2cc 29 08 2012 str lo 16:24:26OSPL90dB SPLRiteS MT 2cc 12 09 2012 str lo 08:35:47Measured according toIEC 60118-0 (1983) and 60711 (1981)and DIN 45605.29 dB SPL24 dB SPLQuiescent1.0 mA1.0 mATypical1.1 mA1.3 mA130Size 312 (IEC PR41)IRIL (IEC 60118-13-2011)800/1400/2000 MHz: 27/46/51 dB SPL* Based on the standardised battery consumption measurement (IIC 60118-0.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment15

RITE 85OTICON ALTA PROOTICON ALTAEAR SIMULATOR2CC COUPLERMeasured according toANSI S3.22 (2003) and S3.7 (1995),IEC 60118-7 (2005) and IEC 60318-5 (2006).11090100Hz50010002000 Hz500010000Full-on GaindB60505030100200Hz50010002000 Hz500010000100200Hz50010002000 HzAcoustic input: 60 dB SPLMagnetic input: 31.6 mA/mEquivalent input noise level (A)Battery consumptionBattery life, calculated, hours*Hz50010002000 Hz5000500080100200Hz50010002000 Hz5000Acoustic input: 60 dB SPLMagnetic input: 31.6 mA/m127 dB SPL118 dB SPL114 dB SPLAverage119 dB SPL114 dB SPLPeak65 dB55 dB1600 Hz51 dB43 dBAverage52 dB47 dB44 dB38 dB100-9500 Hz100-8700 Hz1 mA/m field79 dB SPL-10 mA/m field99 dB SPL--95/95 dB SPL500 Hz 2 % 2 %800 Hz2.4 % 2 %1600 Hz 2 % 2 %Omni25 dB SPL18 dB SPLDir33 dB SPL25 dB SPLQuiescent1.0 mA1.0 mATypical1.1 mA1.2 mA130800/1400/2000 MHz: 19/41/36 dB SPL* Based on the standardised battery consumption measurement (IIC 60118-0.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment161000090Size 312 (IEC PR41)IRIL (IEC 60118-13-2011)10000Frequency Response123 dB SPLSPLITS L/R(Input 70 dB SPL)200PeakFrequency rangeTotal harmonic distortion100002000 Hz1600 HzReference test gainTelecoil output (1600 Hz)50001000Full-on GaindB SPL110100Full-on gain100100805003011090Hz40Frequency ResponsedB SPL200dB6040OSPL90100mRiteM FOG 711 29 08 2012 str lo 16:25:51Technical informationOmnidirectional mode is used unlessotherwise stated.20090RiteM MT 711 12 09 2012 str lo 08:16:53Scale 1:1100mRiteM MPO 2cc 29 08 2012 str lo 15:40:54120110mRiteM MPO 711 29 08 2012 str lo 15:41:44120100OSPL90dB SPLmRiteM FOG 2cc 29 08 2012 str lo 16:26:43OSPL90dB SPL10000RiteM MT 2cc 12 09 2012 str lo 08:17:42Measured according toIEC 60118-0 (1983) and 60711 (1981)and DIN 45605.

RITE 100OTICON ALTA PROOTICON ALTAEAR S

hearing solution with our most advanced technologies. The audiology in Alta provides its users premium listening performance and allows to factoring in individual listening preferences and needs of each client. The Alta family styles range from compact In-the-Ear styles to a broad palette of Behind-the-Ear styles.File Size: 1MB

Related Documents:

10 0-10 20 30 40 50 60 70 80 90 100 110 120 125 250 500 1k 2k 4k 8k Hz dB HL INFORMACIÓN DE PRODUCTO OTICON RIA2 PRO OTICON RIA2 BANDA DE ADAPTACIÓN Oticon Ria2 está diseñado a partir de la nueva plataforma Inium Sense.

Oticon Ria2 is built on the Inium Sense platform. Ria2 audiology provides its users with essential listening performance and can be adjusted to the individual's listening preferences. Ria2 has dedicated programs to support difficult listening situations. The Ria2 family styles range from compact in-the-ear styles to a broad palette

Oticon Ria is built on the Inium platform and is our best performing hearing solution in the essential category. The audiology in Ria provides its users essential listening performance and allows to factoring in listening preferences and needs of each client. The Ria family styles range from compact In-the-Ear styles to a broad palette

Oticon is a historical one that relies heavily on the large number of thick descriptions of Oticon that have been produced by a number of mainly Danish academics, . Oticon became a famous and admired instance of rad-ical organizational change. CEO Lars Kolind and his new organizational d

When it comes to the ALTA Best Practices Framework, respondents’ opinions were generally positive, with 54 percent viewing ALTA Best Practices as ALTA’s attempt to provide a mechanism for self-regulation, 49 percent believing that ALTA Best Practices are something every settlement professional should follow and 51 percent seeing ALTA

Read the following documents before using the PHANTOMTM 4 Pro / Pro : 1. In the Box 2. Phantom 4 Pro / Pro User Manual 3. Phantom 4 Pro / Pro Quick Start Guide 4. Phantom 4 Pro / Pro Series Disclaimer and Safety Guidelines 5. Phantom 4 Pro / Pro Series Intelligent Flight Battery Safety Guidelines

Soft Speech Booster Soft Speech Booster is a feature of VAC that provides increased level of soft gain at high frequencies. The feature en-hances the details of soft speech signals and is adapted to client’s individual needs and preferences for soft sounds and soft speech. The new Soft Sound Perception trimmer in Genie adjusts how the soft

The nonlinear springs are defined using API p–y curves at regular depth . intervals, where p represents the lateral soil resistance per unit length of the pile and y is the lateral deflection of the pile (API, 2007). As it was discussed before response of a single pile is different from response of a pile in a pile group due to group effect. One of the most common methods of accounting for .