Stand Alone Access ControlAlarm LockStand Alone Cylindrical Access Control Grade 1 Durability – BHMA Grade 1Lockset with rugged clutch mechanism for exceptional strength andreliability. Standard Interchangeable Core (IC)models are prepped to accept, Best,Falcon, Arrow and KSP IC core cylinders. Multi-level user capability, up to 100different group or individual codes. 1master, 10 managers, 90 basic users,3 one time entry codes Individual, group or total user lockoutcodes Non-handed for easy installation andversatility 2 Wire remote override or key bypasscapability Passage Mode Visual and audible entry indicators Programmable relay functions Flex-Drive motor operates latchmechanismAlarm LockDL2700 FeaturesSupplied with SC1 keywaynot I/C Core as shown.DL2700ICPrepped for small format I/C coresuch as Arrow, Best, Falcon, KSP,and Kaba Peaks. InterchangeableCore not included.“WP” Weatherproof Model Dual water-sealed keypad, with silicone outer seal and mylar inner sealfor extra protection. Waterproof battery holder. Completely encapsulated circuitboard hermetically sealed againstthe elements. Comprehensively tested to be ratedfor direct water exposure, with anoperating temperature range of 66C to -35C.Part #DescriptionEZ #DL2800 26DTrilogy Lock with Audit071123DL2700 26DT2 Lever Lock062860DL2700WP26D*T2 Lever Lock068444DL2700IC26DT2 I/C core Lever Lock062864DL2800 Features Rugged clutch mechanism insures long life & durability 150 scheduled events 200 User Codes: Master, Manager, Supervisor and Basic Users. Also onetime entry code 1000 Event Log All IC Core models include a large format key in knob cylinder, supporting Best, Falcon, Arrow and KSP. “Special Order Interchangeable CorePreps: Yale, Medeco, Sargent, Corbin/Russwin, Schlage “WP” Weatherproof Models -31 F to 151 F Timed entry allowance from 5-15 seconds Greater security with “Temporary Keypad Lockout” after 3 unsuccessfulcode-entry attempts Audit Trail with Time/Date Stamp for a printable record of all electronicactivity Real Time Clock 4 Quick Schedules of the most common routines Battery operated; uses 5 AA batteries Available in standard key override and interchangeable core models accepting 6 or 7 pin cores fromArrow, Best, Falcon, or KSP. Other IC core preps available.*Weatherized for extreme weather in outdoor use.

Alarm LockStand Alone Keypad & Proximity AccessAlarm LockDL3000 With Audit Trail Features: 1600 Event log. Up to 150 scheduled eventsmay be programmed tounlock/lock, disable/enableusers, disable/enableauxiliary input. Four quick schedules allowprogramming of the fourmost common time schedulesall in one step. Print out event log and usercode list. Extensive keypad programming error checking. 300 user codes provided. 3, 4, 5, or 6 digit user codes. Up to four one-time onlyschedules allow a user toenable other users or tounlock the lock for a certaintime period, without havingto return to the lock.DL3000 26DMfg #UsersEZ #DL3000 26D300068180DL3200 26D2000100409Supplied with SC1 keywaynot I/C Core as shown.Stand Alone Keypad and/or Proximity Access A ccepts most HID Proximity cards andkeyfobs including 26 - 48 bit formats. 2000 User Codes: Master; manager; supervisor; basic users. Users are individually programmed to usea card only, code only, or for the highestsecurity; both card and code. Card data can be added to software via thelock, card reader module or PC. Batch enroll feature allows many cards to bequickly added to the software via the lock without the use of a PC. Weatherproof operates from -29º C to 66º C. Program data transferred to lock via AL-PCI(PC interface) or AL-DTM (data transfermodule). Real time clock enables up to 500 scheduledevents and holiday schedules. Up to 40,000 event Audit Trail with printedtime/date-stamped log of all electronicactivity can be extracted from the lockby using the AL-IRI (infrared printer), theAL-DTM (data transfer module) or AL-PCI (PCinterface). 5 AA batteries furnished; 60,000 cyclestypical. Audible low battery alert. “Quick Passage” Mode enabled with anauthorized user code and function code(does not require lock to be in programmode). Standard SC1 key overrideMfg. #PDL3000 26DEZ#074032ADVANCED “SMART” APPLICATIONS S cheduled Events: Program to lock/unlock;disable/enable users; 4 built-in time schedules. A udit Trail with Time/Date Stamp:Provides a printable record of all electronic activity, including Unlock/lock events, program modechanges, user entry, keypad lockout, remoterelease events, unauthorized code attempts, etc. 4 Programming levels. 4 User groups. 3 to 6 digit codes. O ne-time service code. Total user lockout code. “First-Manager-In” controls three (3) differentfeatures:Passage mode, group of users and relay options. Tri-colored LED indicator shows code acceptanceor denial (green or red, respectively),Or low battery condition (yellow). N on-volatile memory of both programming andAudit Trail activity. K eypad lockout after numerous attempts to“guess” codes. P rogrammable Form C Relay functions forschedules on manual control of CCTV, lighting,ambush function, alarm system, etc.

Narrow Stile & Exit Device AccessAlarm LockStand Alone Exit Device Access ControlETDLS1G 26D V99of standard RIM Cylinders Battery operated; uses 5 AAbatteriesMfg #ETPDLS1G26DV99Proximity Model: Includes all of the features aboveplus: Accepts most HID Proximity cardsand keyfobs Users are individually programmed to use a cardonly, code, only, or for highestsecurity – both card and code Prox card data can be added tosoftware by uploading fromlock, by using AL-PRE or enteringdirectly from computer usingDL-WINDOWS software.CredentialETDLS1G 26D V99 KeypadAlarm Lock For Von Duprin 99 & 98 ExitDevices. Clutch Mechanism insures longlife and durability Fingertip and/or WindowsProgrammable 2000 User Codes: Master, manager,supervisor and users Real TimeClock for up to 40,000 EventTime/Date-Stamped Audit Trail Up to 500 Lock/Unlock Schedules(with Time Zone Support) Rugged 12 Button Metal Keypad Non-Handed; Fully FieldReversible Adaptable to most major vendorsEZ #076586ETPDLS1G26DV99 Keypad & Proximity 080924Stand Alone Narrow Stile Access Control for Adams Rite TypeLocks & Narrow Stile Exit DevicesDL1300 Aluminum door retrofit outside trim for Adams Rite 1850,1950, 4710, 4070, 4730, 4900 Series and MS1850S andMS1950S series locks All metal, vandal-resistant 12 button keypad with automatic timed scheduled locking/unlocking and audit trail DL1300 supports 2000 users, PC programming/reportingand features 40,000 event audit trail by user with 500event schedule/real time clock. Weatherproof -35 to 66 C Long-life, battery- operation for 80,000 cycles on supplied2 lithium 3V batteries Low battery alert Compact styling 14-3/8”H x 1-5/8”D x 1-3/4”W Key override 1-1/4” mortise cylinder supplied. Can use 11/8”, 1-1/4” and 1-3/8”)PDL1300 26DPDL1300ET 26DMfg # For backsets 31/32”, 1-1/8” and 1-1/2” with stile thicknessof 1-3/4” Non-handed; fully field-reversible Stocked in satin chrome finish.PDL1300 Includes all of the features of the DL1300 but also has builtin HID prox reader Easy Tap & Add batch prox ID card enrollment mode allowsmany cards to be quickly added without PC but is alsodownloadable from PC or prox enroller tool Supplied lithium battery for PDL1300 will operate for65,000 cycles.PDL1300ETFeatures of the PDL1300 but for Arrow S1200/S1250, DCI1200/1300, Von Duprin 22, Corbin ED8200 & Von Duprin 33panic devicesTypeCredentialEZ #DL1300 26D1Adams Rite Latch & BoltKeypad087463PDL1300 26DAdams Rite Latch & BoltKeypad & Proximity090072PDL1300ET 26DNarrow Stile Exit DevicesKeypad & Proximity091453

Alarm LockKeypad/Proximity Access, AccessoriesAlarm LockKeypad & ProximityAccess ControlPDK3000DK3000Mfg #CredentialKeypadPDK3000 26DKeypad & Proximity 077222PDK3000 Includes all of the features of the DK3000 but also has built-in HIDproximity reader Easy Tap & Add batch prox ID card enrollment mode allows manycards to be quickly added without PC but is also downloadable fromPC or prox enroller toolEZ #DK3000 26DDK3000 For use with 12V or 24V (AC or DC) electric strikes, magnetic locks orother devices. For wall mount or single gang box Timed egress input allows door to open for 5, 10 or 15 seconds. 2 high-current Rated 8A Relays for device control Weatherproof, rugged all-metal 12 button keypad 2,000 user codes DK3000 supports 2000 users, PC programming/reporting and features 40,000 event audit trail by user with 500 event schedule/realtime clock. Tamper alarm when attempts are made to vandalize or removeDK3000 Remote-Release Feature/Request-to-Exit Input077220PC12Program & Audit Trail Accessories For programming locks with laptopwith Windows software Serial computer interface cable. Includes DL Windows softwareDTM Data Transfer Module Transfers program data from a PCto the Stand Alone unit Receives audit trails from StandAlone units. Can send program data for up to200 units. Includes DL Windows software.Mfg #Program TypeAL PC12 USB USB version includes USB to serialconversion cable.DL Windows (Included with DTM &PCI) Windows format software used to create programming, manager, users and schedules, &receive audit trail from locks, Requires Microsoft Windows 98, 2000, XP, Vista.Vista requires installing Alarm Lock patch andrunning program in XP mode.EZ #DTMData Transfer Module068231PCI2Laptop Serial Programming068230AL PC12 USBLaptop USB Programming091452Proximity Cards & Fobs ProxKey II proximity key fob incorporates Proximity Cards & Fobs are Alarm Lock Proproximity technology into a convenientprietary 37 Bit.device approximately the size of an auto- Cards are sold as noted by the packagemotive key (HID1346).Mfg. #10Credential TypePkg Qty,EZ#HID1326Clamshell Card with Slot 100074039HID1326PK10Clamshell Card with Slot 10086296HID1346Key Fob08066610HID1346HID1326

Pilfergard Door & Exit AlarmsAlarm LockPG21MS Piezo sounder. Always armed mode: When key isturned counter clockwise to thedisarm position, the key cannot beremoved. To remove key, turn backto arm mode which keeps the unitalways armed. Standard arming mode: Disarm byturning key counter clockwise. Turning key clockwise arms unit. Max-Flex Terminals allow for eithercontinuous power with an externalpower supply or to monitor multiple doors with one unit. Multiple door monitoring permittedwith built-in external reed switches Status Indicator :LED indicated REDwhen armed.PG10 Pilfergard Model PG10 exitdard mortise cylinder notdoor alarm designed tosupplied.)deter the use of the se- Tamper supervised withcured door by soundingtwo separate tampera twin action alarm whenswitches.opened by unauthorized Test button verifies battery.personnel. Replacement battery is Can be bypassed from inBP6side or outside by the useof a key. (Requires stan- 3 Security levels for: (A)PG30High security, (B) Unat Keypad controlled nartended applications, (C)row stile door alarm,Flexible control for desimilar to PG21livery doors, etc. Digital codes for mas Audible low batteryter, management andwarningpassage (used for autoarming) 3 Programmable 95dbsiren styles: Sweep,Pulsed, & SteadyMfg Entry Delay Time Options: 15 seconds,75 seconds, or 205 seconds. For standard or narrow stile doors Can be set for continuous alarm, minute shutdown with auto reset, andexit/entry delay Uses standard mortise cylinder (notsupplied Tamper switch supervised For exterior key control, optional RIMcylinder may be used Uses 9V alkaline battery (not supplied).Alarm LockPilfergard Door AlarmsPG21E MS Like PG21 but includes additionalterminal strip for remote monitoring and additional door monitoring.TypeFinishEZ #PG10LegacyAluminum009517PG21MSNarrow StileMetallic Silver009762PG21E MSEnhanced Narrow StileMetallic Silver080340PG30Keypad Narrow StileMetallic Silver031253Panic Exit AlarmsMfg #250EZ # Deadbolt and deadlatch meet UL re-latching requirements 95db Dual tone siren Selectable 2 minute alarm cutoff or constant alarm withmanual reset. Powered with 9V battery with audible low battery warning Non-handed surface installations on single or double doors02789511

Alarm LockExit Alarm, Electric Deadbolt, Door LoopAlarm LockExit Alarm & 15 Second Delayed Egress Alarm700 [ALAR]700 [ALAR]Mfg #TypeEZ #700 [ALAR]Standard Exit Alarm027897715Delayed Egress Exit Alarm 000550Electric Deadbolts Deadbolt and deadlatch meet UL re-latching requirements 95db Dual tone siren Changeable 2 minute auto reset or constant alarmwith manual reset Powered with 9V battery with audible low battery warning Non-handed surface installations on single ordouble doors 33” length for doors up to 36”Armoured Door Loop271 [ALAR]715 15 Second Delayed Egress 15 second delayed egress with instant 95db DualPiezo alarm which meets UL specifications. Instant alarmed exit in case of actual emergencyor fire which meets life safety codes. Surface mount unit in a standard panic bar deadbolt/deadlatch design Monitoring output for simultaneous use of CCTVcamera, secondary siren, remote monitoringconsole, etc. Smoke detector input can be used to power existing system or standalone smoke detectors) Includes armored door cord and cables for hardwiring 9V battery back-up powers in event of power failureBattery Pack Long life sealed replacement9V battery pack for 11A,PG10, & LL1103104RA Projects the bolt only while power is applied (103). Retracts the bolt when power is interrupted (104RA). Lock or unlock by remote switch, key switch, timer orother electrical contact. Size: 1-3/4”W x 6-3/4” L (including keeper) Bolt diameter is 5/8” and projects 5/8”. Keepers included.Mfg #12TypeEZ#103Fail Safe 24VAC009758104RAFail Secure 24VAC 009759 For use with electrified locks. Brings electric current from the hinge side ofa door frame across to the door. 18” Flexible armored cable. End brackets are deep drawn anodized aluminum to conceal wire connections.Mfg #EZ #271 [ALAR]035045BP6Mfg #BP6EZ #000532

DL2800 26D Trilogy Lock with Audit 071123 DL2700 26D T2 Lever Lock 062860 DL2700WP26D* T2 Lever Lock 068444 DL2700IC26D T2 I/C core Lever Lock 062864 Supplied with SC1 keyway not I/C Core as shown. 8 Alarm Lock Alarm Lock Stand Alone K

Related Documents:

Alarm 1 is a ‘Sound Once’ alarm, and Alarm 2 is an ‘Everyday’ alarm. Alarm 1 Setting/Alarm 2 Setting Press the ‘Alarm 1’ button (Ref.4) or ‘Alarm 2’ button (Ref.5) to activate alarm settings. ‘OFF’ will begin lashing on the screen. Select Alarm 1 or 2 b

Run Card Requirements Continued Structure Fire goes to 7th Alarm and all 7 Alarm and all 7 Alarms are required. Brush Fire goes to 7th Alarm and all 7 Alarm and all 7 alarms are required. All other incident types can go to 4th Alarm Alarm and minimum of 2nd alarm is required.alarm is required. When a Compan

2. Open the alarm test valve. Verify that the sprinkler alarm bell and/or the pressure alarm switch/ electric alarm properly actuate. Close the alarm test valve and verify that water has ceased to flow from the alarm line drain. 3. Clean the 20 NB (3/4”) strainer provided on the sprinkler alarm bell line. 4. Clean the strainer of restriction .

Setting the Alarm 1. Press knob to turn ON alarm 2. Alarm time will begin to flash, adjust by rotating knob, press knob to select. (Alarm will automatically set to last selected alarm time after 6 seconds) 3. Press knob to turn OFF alarm In Single Day Alarm On Mode: alarm time will reset to 6:

DETECTION ZONE 11 DETECTION ZONE 12 ALARM ZONE 1 ALARM ZONE 2 ALARM ZONE 3 ALARM ZONE 4 Alarm Zones An alarm zone is clearly defined within the standard but generally is an area of the building coinciding with the fire compartment boundaries. There must be a clear break between these alarm zones to ensure alert and evacuation messages are not .

NFS2-640 Intelligent Addressable Fire Alarm System Intelligent Fire Alarm Control Panels dn-7111:b † A-13 NFS2-640 7111pho2.jpg General The NFS2-640 intelligent Fire Alarm Control Panel is part of the ONYX Series of Fire Alarm Controls from NOTIFIER. As a stand-alone small-to-large system, or as a File Size: 710KBPage Count: 10

addressable fire alarm control panel 2 loop addressable fire alarm control panel 4 loop addressable fire alarm control panel 6 loop addressable fire alarm control panel 8 loop addressable fire alarm control panel product code: m.u.yan.00016 product code: m.u.yan.00018 battery included product code: m.u.yan.00020 product code: m.u.yan.00022

How Alarms Fit into Process Operating Situation 6 Alarm Management 8 Benefi ts 8 imo-rothenberg-00fm.indd ix 7/31/09 1:07 PM. x Contents † Chapter 1 1.4 A Brief History of Alarm Management 10 1.5 The “Management” in Alarm Management 11 1.6 Alarm Design Roadmap 12 1.7 Audience for this Book 13 1.8 Importance of Alarm Management 13 1.9 Fundamentals of Alarm Management 15 Bottom Line of .