LINOVECTOR II - Mestek

2y ago
5 Views
2 Downloads
655.82 KB
6 Pages
Last View : 2y ago
Last Download : 3m ago
Upload by : Jewel Payne
Transcription

LINOVECTOR IISubmittalSpecificationBare Element “3”ELEMENT:TYPE:LENGTHS:Cu/AL (Mechanically Expanded)2'0" thru 12'6" in 1" Incrementsfor 1" & 1-1/4" Cu.2'0" to 8'0" in 1" Incrementsfor ¾" Cu.See Catalog for WorkingPressuresWall Mtd B.B. HngrELEMENT:TYPE:IPS Steel (Mechanically Expanded)LENGTHS: 2'0" to 12'6" in 1" IncrementsNPT Thread both Ends (Std)Beveled Ends for Field Weld (Opt’l)See Catalog for WorkingPressuresOne End Flared (Std)BRACKETS:Bare Element “3”Copper/Aluminum andSteel Element RatingsBRACKETS:Wall Mtd B.B. HngrBare Element “3” 3-1/4" Wide Fin B.B. Hanger Wall “3”PROJECT: DATE:LOCATION:1/20260 North Elm St., Westfield, MA 01085(413) 568-9571 Fax: (413) CTOR:PO NUMBER:

STYLE “3” BARE ELEMENTCOPPER/ALUMINUM ELEMENTSTUBE CATALOGSIZE DESIGNATIONHEIGHT X WIDTHFIN SIZEFINSPERFT.3/4"VC3/4-333-1/4" SQ.323/4"VC3/4-343-1/4" SQ.403/4"VC3/4-353-1/4" SQ.501"VC333-1/4" SQ.321"VC343-1/4" SQ.401"VC353-1/4" SQ.501-1/4"VC1333-1/4" SQ.321-1/4"VC1343-1/4" SQ.401-1/4"VC1353-1/4" SQ.50ALL RATINGS ARE IN BTU/HR/LIN FT AND BASED ON 3 FPS VELOCITY, 65 EATSTEAMTIERSFINANDMOUNTING 215 FACTORTHICKNESS CENTERS HEIGHT1.00IN INCHESIN INCHESIN INCHES18-7/8970.0202-6 CL14-7/817203-6 CL20-7/8241018-7/81140.0202-6 CL14-7/818803-6 CL20-7/8257018-7/81260.0202-6 CL14-7/820103-6 CL20-7/8269018-7/8970.0202-6 CL14-7/817203-6 CL20-7/8237018-7/81080.0202-6 CL14-7/818503-6 CL20-7/8249018-7/81210.0202-6 CL14-7/819403-6 CL20-7/8260018-7/8970.0202-6 CL14-7/816803-6 CL20-7/8236018-7/81060.0202-6 CL14-7/818403-6 CL20-7/8245018-7/81170.0202-6 CL14-7/819003-6 CL20-7/82550HOT WATER (AVG.)200 190 180 170 160 150 140 130 120 CORRECTION FACTORS FOR AVERAGE WATER 06705905104403903202501480 1340 1190 10509107706905704502070 1880 1660 1470 1280 10809608006309808907907006005104603803001620 1470 1300 1150 10008507506204902210 2000 1770 1570 1360 1160 103085067010809808707706705705004203301730 1570 1390 1230 10709008006605202310 2100 1860 1640 1430 1210 10808907008307606705905104403903202501480 1340 1190 10509107706905704502040 1850 1640 1450 1260 10709507806209308407506605704904303602801590 1440 1280 11309808307406104802140 1940 1720 1520 1320 1120 100082065010409408307406405404804003101670 1510 1340 1180 10308707806405002240 2030 1790 1590 1380 1170 10408606808307606705905104403903202501440 1310 1160 10208907606705504402030 1840 1630 1440 1250 10609407806109108307306505604804203502801580 1440 1270 11209808307406104802110 1910 1690 1490 1300 110098081064010109108107106205304703903001630 1480 1310 1160 10108607606304902190 1990 1760 1560 1350 1150 1020840660Note: Copper tube furnished flared one end standard.STEEL ELEMENTSTUBESIZE1"1"1"1-1/4"1-1/4"1-1/4"Notes:uALL RATINGS ARE IN BTU/HR/LIN FT AND BASED ON 3 FPS VELOCITY, 65 EATSTEAMTIERSFINANDMOUNTING 215 FACTORCATALOGFIN SIZETHICKNESS CENTERS HEIGHT1.00DESIGNATIONHEIGHT X WIDTHIN INCHESIN INCHESIN INCHES18-7/8910VS333-1/4" SQ.32.0322-6 CL14-7/815803-6 CL20-7/8220018-7/8990VS343-1/4" SQ.40.0322-6 CL14-7/817003-6 CL20-7/8235018-7/81060VS353-1/4" SQ.50.0322-6 CL14-7/817903-6 CL20-7/8245018-7/8900VS1333-1/4" SQ.32.0322-6 CL14-7/816203-6 CL20-7/8224018-7/81000VS1343-1/4" SQ.40.0322-6 CL14-7/817003-6 CL20-7/8225018-7/81030VS1353-1/4" SQ.50.0322-6 CL14-7/817503-6 CL20-7/822801) Steel fins furnished as .032 thick, painted black.2) NPT threads furnished on steel elements. Please use domestic fittings for proper installation.3) The ends can be provided chamfered for field welded fittings when specified.FINSPERFT.Bold, italicized units areratedtHOT WATER (AVG.)200 190 180 170 160 150 140 130 120 CORRECTION FACTORS FOR AVERAGE WATER 06305604804103603002401360 1230 10909608407106305204101890 1720 1520 1340 11709908807305708507706806005204504003302601460 1330 1170 10409007706805604402020 1830 1620 1430 1250 10609407806109108307306505604804203502801540 1400 1240 10909508107205904702110 1910 1690 1490 1300 11009808106407707006205504804103603002301390 1260 11209908607306505304201930 1750 1550 1370 1190 10109007405808607806906105304504003302601460 1330 1170 10409007706805604401940 1760 1550 1370 1190 10109007405908908007106305504604103402701510 1370 1210 10709307907005804601960 1780 1570 1390 1210 1030910750590

Design DataCorrection Factor Chart for Non-Standard Mounting HeightsMOUNTINGHEIGHT(Inches)40or more3836343230292827262524232221201918or lessENCLOSURE STYLEFT (FRONT & TOP)3 1/ 4"4 1/ 4"2 3/ 4"FINSFINSFINSBARE PE3 1/ 4"FINS4 1/ 01.1001.100TOP OUTLET “T” IS NOT AFFECTED.The AHRI Ratings cataloged include the factor shown for the recommended mounting height.If the unit is to be installed at a different height than that recommended, the AHRI Rating(except for Top Outlet) must be adjusted as follows: AHRI Rating multiplied byFactor from Table Abovefor actual mounting heightFactor from Table Abovefor recommended mounting heightFORMULA:Factor at 30" Height1.039Catalog Rating x —————————–SOLUTION: 1950 x ——– 1760 BTU/Hr.1.150Factor at 18" HeightDYNAMIC FORMULASBTU GPM x 500 x TD( )BTUGPM --------500TD ( )BTU--------500 TD GPM

Design DataCOMMERCIAL FINNED TUBE RATING CORRECTION CHARTSCATALOG FINNED TUBE RATINGS ARE BASED UPON THE FOLLOWING CONDITIONS: 215 F AVERAGE WATER OR STEAM TEMPERATURE 65 F ENTERING AIR TEMPERATURE 3 FEET PER SECOND WATER FLOW RATE CATALOG MOUNTING HEIGHTUSE THE FOLLOWING CALCULATION WITH CORRECTION FACTORS FOR JOB CONDITIONS TO DETERMINECORRECTED RATING:CORRECTION FACTOR FORCORRECTED RATING (215 F CATALOG RATING) X STEAM OR WATER ANDAVERAGE AIR TEMP.(() ())X CORRECTION FACTOR X CORRECTION FOR MOUNTINGFOR FLOW RATE HTG.-SEE CATALOG RATINGUSE THE FOLLOWING CHARTS TO SELECT CORRECTION FACTORS

Design DataINLET AIR CORRECTION FACTORGUARANTEED WORKING PRESSURES1" IPS — 780 AT TEMPERATURES UP TO 650 F.11 /4" IPS — 660 AT TEMPERATURES UP TO 650 F.2" IPS — 405 AT TEMPERATURES UP TO 650 F.11/4" CU — 194 AT TEMPERATURES UP TO 300 F.1" CU — 204 AT TEMPERATURES UP TO 300 F.3/4" CU — 218 PSI AT TEMPERATURES UP TO 300 F.MAXIMUM PRESSURES AT OTHER TEMPERATURESARE AVAILABLE UPON REQUEST.RATE OF PITCH FOR STEAM 1/2" DROP OVER 20 FT. RUN.PIPE WATER CAPACITIES AND QUANTITIESCIRCULATED AT VELOCITY OF 3* FEET PER SECONDGals. PerGals./Min. @ 3′Lbs./Hr. @ 3′Pipe SizeLinear Ft.Sec. Vel.*Sec. Vel.*1/ 2 .0162.8814403/ 4 .0234.1420701 .0407.20360011/4 .06311.34566011/2 .10218.3691602 .17030.601530012 / 2 .27549.50248503 .39070.2035000*3 Ft./Sec. Velocity is Basic for Hot Water Rating Factors Shown on this Page.LBS. PER HOURVELOCITY FT./SEC. ————————————–(GALS. PER FT.) (3600) (8.3)GLYCOL CORRECTION FACTORSFluid Temperature 200 FEthylenePropylene% 50.852.912Fluid Temperature 180 FEthylenePropylene% 50.842.902Fluid Temperature 140 FEthylenePropylene% 0.821.881ALTITUDE FACTORSApproximate factors for convective heatvalue at varying altitudesAltitudeFerrous Units Copper Alum. UnitsSea Level1.0001.0001,000 ft.984.9692,000 ft.968.9383,000 ft.952.9084,000 ft.936.8785,000 ft.920.8506,000 ft.904.8227,000 ft.889.7958,000 ft.874.7689,000 ft.859.74310,000 ft.844.71815,000 ft.771.60320,000 ft.703.502

Design DataCORRECTION FACTORS FOR STEAM PRESSURESAND AIR TEMPERATURES OTHER THAN STANDARD ENTERING AIR TEMPERATURE, FSTEAMPressureGauge (Vac) 15″ Hg(Vac) 10″(Vac) 5″(Vac) 0 STDAbs. Psi .780.870.951.031.101.171.231.381.511.631.75From Keenan and Keyes — Linear Interpolation.Note: Gauge pressure should be corrected for altitude.CORRECTION FACTORS FOR WATER TEMPERATURESAND AIR TEMPERATURES OTHER THAN STANDARD AVERAGE WATERTEMP. FENTERING AIR TEMPERATURE, FSTD4555657090.19.13.11.067580 9.41.34.28215 01.551.501.391.291.191.091.00

Bare Element “3” . 1 8-7/8 900 770 700 620 550 480 410 360 300 230 2-6 CL 14-7/8 1620 1390 1260 1120 990 860 730 650 530 420 3-6 CL 20-7/8 2240 1930 1750 1550 1370 1190 1010 900 740 580 1-1/4" VS134 3-1/4" SQ.

Related Documents:

INSTALLATION INSTRUCTIONS HVIOM-5 KICKSPACE HEATER 260 NORTH ELM ST., WESTFIELD, MA 01085 TEL: (413) 568-9571 www.mestek.com . If using the "Easy Connect" Flexible Hose Connection Kit, see those installation instructions. 7. Next, prepare the heating element for pipe connections (this procedure will also pertain to floor and wall models). .

The product described in this catalog are warranted by Beacon-Morris, A Mestek Co. to be free from defects in material and workmanship for a period of one (1) year from the date of shipment from Beacon-Morris' plant. Beacon-Morris will repair or replace, at its option, any components which, upon inspection, it findsto be defective,

n1 / l1 natural / propane single stage gas valve - single stage input n2 / l2 natural / propane two stage gas valve - modulating input - high/low fire gas type burner pressure supply pressure voltage amps ignition type flue connection outside combustion air connection min max natural 3.5" w.

5 Heat Transfer (MBH) Delta T (Degrees F) Heat Transfer (MBH) Delta T (Degrees F) Static Pressure Loss (Inc

Hydronic Unit Heaters 8 9. TD Series Tubular Duct Furnace The TD duct furnace is designed with ease of service in mind, and provides the efficiency and durability of Sterling’s tubular heat exchanger. The TD offers left s

Unit Heaters. FOR STEAM AND HOT WATER. 2. The Sterling Cabinet Unit Heater is the industry’s most recent design. Years of manufacturing and engineering experi-ence combined with a concern

application, the TD Series duct furnace is the latest addition to the tubular product line. Coupled with Sterling's "In-Shot" burner technology, TD units are built for superior durability, reliability and performance. Units are available in 7 sizes (100-400 MBH) and offer industry leading efficiencies with a limited 10 year heat exchanger warranty.

23. Sharma, P. D. [1991] : The Fungi (Rastogi & Co. Meerut) 24. Vasishta, B. R. [1990] : Fungi (S. Chand & Co. New Delhi) 25. Sharma, O. P. : Fungi (TMH)