ELECTRICAL CONDUITEMT IMC Rigid Aluminum Time-saving Products

QUALITY CONDUIT.FRIENDLY SERVICE.FAST DELIVERY.We know you have a lot of options for electrical conduit.That’s why we work hard to be your first choice.Why more distributorschoose Western Tube:Tested for bendabilityand threadabilityGalvanization and polymercoatings resist corrosionCustom lengths available(10' standard)UL approval label onall conduit and EMTFast turnaroundand on-time deliveryLocal electrical specifications can vary greatly,but at Western Tube & Conduit Corporation, ourgoal is to deliver high-quality product that’s aseasy to use as possible, no matter where you,your customers or your projects are located.Our conduit is approved for use as the equipmentground conductor in a circuit, which helps reducewiring requirements and simplify installationfor any project. Throughout production, wecontinuously monitor factors that can affectinstallation, such as bendability and wirepush / pull capability.Rounded edges help reduce the chance of wireabrasion, and all our conduit is sized or threadedto accommodate standard fittings. Solid,protective coatings inside and out ensure superiordurability, even in the harshest environments.ServiceWe take a proactive approach to meeting our customers’ needs.By working hard to understand your specific applications andrequirements upfront, we’re able to deliver unparalleled serviceand support every step of the way. Whether you need a quickturnaround or custom conduit, you can always trust us to behighly responsive, flexible and prompt in delivering your order.SafetyWhen it comes to electrical raceways, we believe there’sno safer option than metal conduit when you’re looking forthe best physical protection for wiring. Aluminum conduitensures strength and excellent corrosion resistance, andsteel conduit acts as an effective ground shield, minimizingEMI and external RFI.SatisfactionWith Western Tube, quality is never a question. All of ourproducts conform to the appropriate specifications, andour commitment to quality goes beyond that to include ourprocesses and systems — we’re fully compliant withISO 9001:2015, as well. We strive for continual improvementand hold ourselves to the highest standards, with the goalof getting things right, right from the start.Service, Quality & Friendship Since 1964.800.310.8823 westerntube.com

QUALITY CONDUIT.FRIENDLY SERVICE.FAST DELIVERY.We know you have a lot of options for electrical conduit.That’s why we work hard to be your first choice.Why more distributorschoose Western Tube:Tested for bendabilityand threadabilityGalvanization and polymercoatings resist corrosionCustom lengths available(10' standard)UL approval label onall conduit and EMTFast turnaroundand on-time deliveryLocal electrical specifications can vary greatly,but at Western Tube & Conduit Corporation, ourgoal is to deliver high-quality product that’s aseasy to use as possible, no matter where you,your customers or your projects are located.Our conduit is approved for use as the equipmentground conductor in a circuit, which helps reducewiring requirements and simplify installationfor any project. Throughout production, wecontinuously monitor factors that can affectinstallation, such as bendability and wirepush / pull capability.Rounded edges help reduce the chance of wireabrasion, and all our conduit is sized or threadedto accommodate standard fittings. Solid,protective coatings inside and out ensure superiordurability, even in the harshest environments.ServiceWe take a proactive approach to meeting our customers’ needs.By working hard to understand your specific applications andrequirements upfront, we’re able to deliver unparalleled serviceand support every step of the way. Whether you need a quickturnaround or custom conduit, you can always trust us to behighly responsive, flexible and prompt in delivering your order.SafetyWhen it comes to electrical raceways, we believe there’sno safer option than metal conduit when you’re looking forthe best physical protection for wiring. Aluminum conduitensures strength and excellent corrosion resistance, andsteel conduit acts as an effective ground shield, minimizingEMI and external RFI.SatisfactionWith Western Tube, quality is never a question. All of ourproducts conform to the appropriate specifications, andour commitment to quality goes beyond that to include ourprocesses and systems — we’re fully compliant withISO 9001:2015, as well. We strive for continual improvementand hold ourselves to the highest standards, with the goalof getting things right, right from the start.Service, Quality & Friendship Since 1964.800.310.8823 westerntube.com

Electrical MetallicTubing (EMT)IntermediateMetal Conduit (IMC)To manufacture our high-quality EMT, we uselow-carbon strip steel that is electric-resistancewelded into tubing and then in-line galvanized forsuperior rust protection. The conduit is then coatedwith a low-friction organic polymer inside and out toresist corrosion and make feeding wires easier. Beforeleaving our facility, our EMT undergoes testing toensure it bends without kinking, flattening, flakingor cracking.IMC is manufactured as a cross between EMT andrigid metal conduit (RMC). A slightly thinner gaugethan RMC, IMC is light but strong. It has the sameelectric-resistance welded tube-making processas EMT, but it is threaded like RMC, so the samecouplings can be used for both. Like all of ourelectrical conduit, it is protected by zinc and organiccoatings inside and out, and is thoroughly tested forbendability and threadability before being shipped.Our EMT conforms to: UL-797 CSA C22.2 No. 83.1 ANSI C80.3 NEC Article 358 WW-C-563Standard EMT and Color EMT Weights and Specifications (10' Lengths)Trade Size½¾11 ¼1 ½22 ½33 . perFootFeet inSubBundleQty. inMasterBundleFeet inMasterBundleNom. Wt.per 010174017801320134012901180BandingTape ColorTrade er bundle quantities conform to NEMA Standard RN-2. All Western Tube conduit is UL Listed.Standard EMT Weights and Specifications (20' Lengths)Trade Size½¾11 ¼1 ½22 ½33 ½4MetricDesignatorNominalODNominalIDNominalWt. perFootFeet inSubBundleQty. inMasterBundleFeet inMasterBundleNom. Wt.per 09581910011320783Master bundle quantities conform to NEMA Standard RN-2. All Western Tube conduit is UL Listed. UL-1242 ANSI C80.6 NEC Article 342 WW-C-581IMC Weights and Specifications (10' Lengths)MetricDesignatorNominalWallThicknessOur IMC conforms to:BandingTape essNominalWt. perFoot withCouplingFeet inSubBundleQty. inMasterBundleFeet inMasterBundleNom. Wt.per MasterBundleEnd 2023Orange1 ¼351.6381.4480.0951.58-13513502133Green1 .1500.1052.56-808002048Orange2 760.1505.43-303001629Orange3 1660.1507.00-242401680OrangeMaster bundle quantities conform to NEMA Standard RN-2. All Western Tube conduit is UL Listed.

Electrical MetallicTubing (EMT)IntermediateMetal Conduit (IMC)To manufacture our high-quality EMT, we uselow-carbon strip steel that is electric-resistancewelded into tubing and then in-line galvanized forsuperior rust protection. The conduit is then coatedwith a low-friction organic polymer inside and out toresist corrosion and make feeding wires easier. Beforeleaving our facility, our EMT undergoes testing toensure it bends without kinking, flattening, flakingor cracking.IMC is manufactured as a cross between EMT andrigid metal conduit (RMC). A slightly thinner gaugethan RMC, IMC is light but strong. It has the sameelectric-resistance welded tube-making processas EMT, but it is threaded like RMC, so the samecouplings can be used for both. Like all of ourelectrical conduit, it is protected by zinc and organiccoatings inside and out, and is thoroughly tested forbendability and threadability before being shipped.Our EMT conforms to: UL-797 CSA C22.2 No. 83.1 ANSI C80.3 NEC Article 358 WW-C-563Standard EMT and Color EMT Weights and Specifications (10' Lengths)Trade Size½¾11 ¼1 ½22 ½33 . perFootFeet inSubBundleQty. inMasterBundleFeet inMasterBundleNom. Wt.per 010174017801320134012901180BandingTape ColorTrade er bundle quantities conform to NEMA Standard RN-2. All Western Tube conduit is UL Listed.Standard EMT Weights and Specifications (20' Lengths)Trade Size½¾11 ¼1 ½22 ½33 ½4MetricDesignatorNominalODNominalIDNominalWt. perFootFeet inSubBundleQty. inMasterBundleFeet inMasterBundleNom. Wt.per 09581910011320783Master bundle quantities conform to NEMA Standard RN-2. All Western Tube conduit is UL Listed. UL-1242 ANSI C80.6 NEC Article 342 WW-C-581IMC Weights and Specifications (10' Lengths)MetricDesignatorNominalWallThicknessOur IMC conforms to:BandingTape essNominalWt. perFoot withCouplingFeet inSubBundleQty. inMasterBundleFeet inMasterBundleNom. Wt.per MasterBundleEnd 2023Orange1 ¼351.6381.4480.0951.58-13513502133Green1 .1500.1052.56-808002048Orange2 760.1505.43-303001629Orange3 1660.1507.00-242401680OrangeMaster bundle quantities conform to NEMA Standard RN-2. All Western Tube conduit is UL Listed.

Rigid MetalConduit (RMC)Rigid AluminumConduit (RAC)Manufactured as the heaviest-gauge tubing available,RMC stands up to the most challenging physicalenvironments. Our RMC is hot-dip galvanized and thencoated in layers of chromate conversion and organicpolymer for extra protection. This makes it especiallystrong and resistant to environmental and mechanicalcorrosion. A number of rigorous quality verificationsmust be passed — including bend and thread testing —before any RMC is approved to leave our facility.RAC is designed to provide decades of reliable service fordry, wet, exposed, concealed and hazardous locations.Made of a marine-grade alloy, RAC naturally resistscorrosion. Each piece is threaded on both ends, with acoupling on one end and color-coded thread protectoron the other. RAC is easy to cut and bend as needed.Our RMC conforms to: UL-6 CSA C22.2 No. 45.1 ANSI C80.1 NEC Article 344 WW-C-581Trade Size½¾11 ¼1 ½22 ½33 21802200206021001840Feet inSub-BundleQty. inMasterBundleFeet inMasterBundleNom. Wt.per MasterBundleEnd BlueBlueRigid Metal Conduit Weights and Specifications (20' Lengths)Trade Size½¾11 ¼1 ½22 ½33 ½456MetricDesignatorNominalODNominalIDNominal WallThicknessQty. inFeet inMaster Bundle Master BundleNom. Wt.per 9601840Master bundle quantities conform to NEMA Standard RN-2. All Western Tube conduit is UL Listed. CSA 22.2 No. 45.2 ANSI C80.5 NEC Article 344 WW-C-54-cEnd BlueBlueNominalWt. perFoot withCouplingFeet inSubBundleQty. inMasterBundleFeet inMasterBundleNom. Wt.per .1070.374100-2500935RedTrade SizeMaster bundle quantities conform to NEMA Standard RN-2. All Western Tube conduit is UL Listed.NominalWt. per Footwith Coupling UL-6ARigid Aluminum Conduit Weights and Specifications (10' Lengths)Rigid Metal Conduit Weights and Specifications (10' Lengths)NominalWt. per Footwith CouplingOur RAC conforms to:End CapColor1271.3151.0630.1260.545100-20001090Blue1 ¼351.6601.3940.1330.716-1001000716Red1 0830.1461.185-45450533Blue2 00.2052.463-20200493Blue3 r bundle quantities conform to NEMA Standard RN-2. All Western Tube conduit is UL Listed.

Rigid MetalConduit (RMC)Rigid AluminumConduit (RAC)Manufactured as the heaviest-gauge tubing available,RMC stands up to the most challenging physicalenvironments. Our RMC is hot-dip galvanized and thencoated in layers of chromate conversion and organicpolymer for extra protection. This makes it especiallystrong and resistant to environmental and mechanicalcorrosion. A number of rigorous quality verificationsmust be passed — including bend and thread testing —before any RMC is approved to leave our facility.RAC is designed to provide decades of reliable service fordry, wet, exposed, concealed and hazardous locations.Made of a marine-grade alloy, RAC naturally resistscorrosion. Each piece is threaded on both ends, with acoupling on one end and color-coded thread protectoron the other. RAC is easy to cut and bend as needed.Our RMC conforms to: UL-6 CSA C22.2 No. 45.1 ANSI C80.1 NEC Article 344 WW-C-581Trade Size½¾11 ¼1 ½22 ½33 21802200206021001840Feet inSub-BundleQty. inMasterBundleFeet inMasterBundleNom. Wt.per MasterBundleEnd BlueBlueRigid Metal Conduit Weights and Specifications (20' Lengths)Trade Size½¾11 ¼1 ½22 ½33 ½456MetricDesignatorNominalODNominalIDNominal WallThicknessQty. inFeet inMaster Bundle Master BundleNom. Wt.per 9601840Master bundle quantities conform to NEMA Standard RN-2. All Western Tube conduit is UL Listed. CSA 22.2 No. 45.2 ANSI C80.5 NEC Article 344 WW-C-54-cEnd BlueBlueNominalWt. perFoot withCouplingFeet inSubBundleQty. inMasterBundleFeet inMasterBundleNom. Wt.per .1070.374100-2500935RedTrade SizeMaster bundle quantities conform to NEMA Standard RN-2. All Western Tube conduit is UL Listed.NominalWt. per Footwith Coupling UL-6ARigid Aluminum Conduit Weights and Specifications (10' Lengths)Rigid Metal Conduit Weights and Specifications (10' Lengths)NominalWt. per Footwith CouplingOur RAC conforms to:End CapColor1271.3151.0630.1260.545100-20001090Blue1 ¼351.6601.3940.1330.716-1001000716Red1 0830.1461.185-45450533Blue2 00.2052.463-20200493Blue3 r bundle quantities conform to NEMA Standard RN-2. All Western Tube conduit is UL Listed.

Time-savingElectrical ProductsAttaching couplings to EMT and conduit might not seem to waste much time, but you’dbe amazed at how quickly the seconds add up. To help contractors install racewaysfaster, Western Tube offers a full line of products with pre-installed fittings, as well ascolor-coded and extra-long conduit. They all work together to save time on every job.Rigid MetalConduit (RMC)Manufactured as the heaviest-gauge tubing available,RMC stands up to the most challenging physicalenvironments. Our RMC is hot-dip galvanized and thencoated in layers of chromate conversion and organicpolymer for extra protection. This makes it especiallystrong and resistant to environmental and mechanicalcorrosion. A number of rigorous quality verificationsmust be passed — including bend and thread testing —before any RMC is approved to leave our facility.Trade Size½¾11 ¼1 ½22 ½33 Wt. per Footwith Coupling UL-6 CSA C22.2 No. 45.1SmartCompression EMT ANSI C80.1 NEC Article 344 WW-C-581Feet inSub-BundleQty. inMasterBundleFeet inMasterBundleNom. Wt.per 07021802200206021001840End CapColorWestern Tube’s SmartCompression EMT with pre-installedcompression coupling saves time on every job wherecompression couplings are specified or preferred. No needto fumble with loose couplings that have to be tightenedindividually. With SmartCompression EMT, just connect andtighten! Plus, the smooth ID coating allows for faster wire pulling.Rigid Metal Conduit Weights and Specifications (20' Lengths)½¾11 ¼1 ½22 ½33 ½456MetricDesignatorNominalODNominalIDNominal WallThicknessNominalWt. per Footwith 840Master bundle quantities conform to NEMA Standard RN-2. All Western Tube conduit is UL Listed.Qty. inFeet inMaster Bundle Master BundleNom. Wt.per MasterBundle20' EMT and ConduitUsing 20' conduit requires special delivery and handling,but it’s well worth the savings! You’ll reduce couplingcosts and installation time by at least 50%, compared totraditional 10' BlueBlueMaster bundle quantities conform to NEMA Standard RN-2. All Western Tube conduit is UL Listed.Trade SizeWestern Tube’s SpeedCouple pre-installed swivel couplingconnects conduit much faster and cuts material costs by asmuch as 50%, compared with three-piece couplings. Just turnSpeedCouple, not the conduit. SpeedCouple is available on rigidmetal conduit (RMC) and intermediate metal conduit (IMC).Our RMC conforms to:Rigid Metal Conduit Weights and Specifications (10' Lengths)MetricDesignatorSpeedCoupleEnd BlueBlueSmartSet EMTWestern Tube’s SmartSet EMT features an engineeredsteel set screw coupling on one end so you can worksmarter — saving you time and money on every job. No needto purchase, inventory and install separate couplings!Color EMTWhen you have multiple raceways, it can be difficult totell which circuit is which. Color conduit makes it easy todifferentiate between emergency circuits, data transmissioncircuits, computer power circuits and more. We offer eightvibrantly colored, rust-resistant coatings that won’t crack,flake or fade. The EMT itself is the same as our standardgalvanized, UL Listed conduit; we just add dye to theouter organic coating to achieve the desired hue.

Time-savingElectrical ProductsAttaching couplings to EMT and conduit might not seem to waste much time, but you’dbe amazed at how quickly the seconds add up. To help contractors install racewaysfaster, Western Tube offers a full line of products with pre-installed fittings, as well ascolor-coded and extra-long conduit. They all work together to save time on every job.Rigid MetalConduit (RMC)Manufactured as the heaviest-gauge tubing available,RMC stands up to the most challenging physicalenvironments. Our RMC is hot-dip galvanized and thencoated in layers of chromate conversion and organicpolymer for extra protection. This makes it especiallystrong and resistant to environmental and mechanicalcorrosion. A number of rigorous quality verificationsmust be passed — including bend and thread testing —before any RMC is approved to leave our facility.Trade Size½¾11 ¼1 ½22 ½33 Wt. per Footwith Coupling UL-6 CSA C22.2 No. 45.1SmartCompression EMT ANSI C80.1 NEC Article 344 WW-C-581Feet inSub-BundleQty. inMasterBundleFeet inMasterBundleNom. Wt.per 07021802200206021001840End CapColorWestern Tube’s SmartCompression EMT with pre-installedcompression coupling saves time on every job wherecompression couplings are specified or preferred. No needto fumble with loose couplings that have to be tightenedindividually. With SmartCompression EMT, just connect andtighten! Plus, the smooth ID coating allows for faster wire pulling.Rigid Metal Conduit Weights and Specifications (20' Lengths)½¾11 ¼1 ½22 ½33 ½456MetricDesignatorNominalODNominalIDNominal WallThicknessNominalWt. per Footwith 840Master bundle quantities conform to NEMA Standard RN-2. All Western Tube conduit is UL Listed.Qty. inFeet inMaster Bundle Master BundleNom. Wt.per MasterBundle20' EMT and ConduitUsing 20' conduit requires special delivery and handling,but it’s well worth the savings! You’ll reduce couplingcosts and installation time by at least 50%, compared totraditional 10' BlueBlueMaster bundle quantities conform to NEMA Standard RN-2. All Western Tube conduit is UL Listed.Trade SizeWestern Tube’s SpeedCouple pre-installed swivel couplingconnects conduit much faster and cuts material costs by asmuch as 50%, compared with three-piece couplings. Just turnSpeedCouple, not the conduit. SpeedCouple is available on rigidmetal conduit (RMC) and intermediate metal conduit (IMC).Our RMC conforms to:Rigid Metal Conduit Weights and Specifications (10' Lengths)MetricDesignatorSpeedCoupleEnd BlueBlueSmartSet EMTWestern Tube’s SmartSet EMT features an engineeredsteel set screw coupling on one end so you can worksmarter — saving you time and money on every job. No needto purchase, inventory and install separate couplings!Color EMTWhen you have multiple raceways, it can be difficult totell which circuit is which. Color conduit makes it easy todifferentiate between emergency circuits, data transmissioncircuits, computer power circuits and more. We offer eightvibrantly colored, rust-resistant coatings that won’t crack,flake or fade. The EMT itself is the same as our standardgalvanized, UL Listed conduit; we just add dye to theouter organic coating to achieve the desired hue.

Service, Quality and Friendship Since 1964Western Tube & Conduit Corporation is the West Coast’s leading manufacturerof electrical conduit. All of our products are certified to ISO 9001:2015and conform to the appropriate industry specifications. The success of ourcustomers is at the heart of our mission, which is why we pride ourselveson consistently producing high-quality products and delivering top-notchcustomer service. We will always work to be the best at what we do, so you canprovide the best possible experience for your customers, too.Trade association affiliates:2001 East Dominguez StreetLong Beach, CA 90810800.310.8823westerntube.comCorporate Office227 West Monroe StreetSuite 2600Chicago, IL 020720

CSA C22.2 No. 83.1 ANSI C80.3 NEC Article 358 WW-C-563 Trade Size Metric Designator Nominal OD Nominal ID Nominal Wall Thickness Nominal Wt. per Foot Feet in Sub-Bundle Qty. in Master Bundle Feet in Master Bundle Nom. Wt. per Master Bundle Banding Tape Color mm in. in. i

Related Documents:

2) Braced tube 3) Bundled tube 4) Tube-in-tube 5) Tubed mega frames A.Tube in Tube Structures The term "tube in tube" is largely self-explanatory in that second ring of columns, the ring surrounding the central service core of the building, are used as an ineer framed or braced tbe. The purpose of the second tube is to increase

PVC Rigid Conduit & Fittings 4 PVC Rigid Conduit Sch40 5 PVC Rigid Conduit Sch80 6 PVC Conduit Utility Duct DB-60, DB-100 & DB-120 7 PVC Conduit Utility Duct EB-20 & EB-35 8 elephone Duct - Type CT 8 PVC Pipe Chart Loading Chart 9 Standard Radius PVC Elbows 10 - 13 Special Radius PVC

(UL), CSA, ASTM, ANSI, NEMA, and other agencies. UL listings include: Ferrous electrical conduit File # DYIX.E226472 Electrical metallic tubing File # FJMX.E315441 Non-Ferrous electrical conduit (aluminum & stainless) File # DYWV.E230584 Stub ups L-shaped conduit (90 bend) Back-to-back bends Conduit that turns two corners in a 180 bend .

4. Always use the proper size conduit bender for the conduit size being bent. The conduit will not bend properly and/or will be damaged if a mismatch of bender and conduit size is used. Place the bender onto the tubing with the hook pointed towards the free end to be bent upwards. Make sure the conduit is r

Part No. Description Conduit Size MXC2001XX 2" 1-Cell MaxCell 1-1/2" up to 2" Conduit MXC3456XX 3" 3-Cell MaxCell 3" or Larger Conduit MXC2003XX 2" 3-Cell MaxCell 2" Conduit MXC2002XX 2" 2-Cell MaxCell 1-1/2" or 2" Conduit MXC4003XX 4" 3-Cell MaxCell 3" or Larger Conduit Max Cell www.ptsupply.com marketing@ptsupply.com 800-238-7514

conduit stub, Fig. 6-19-134H, Fig. 6-19-134I, and Fig. 6-19-134J. B. The customer may install gray schedule 40 PVC conduit (UL approved). Couplings are preferred to bell ends. All joints must be glued with appropriate PVC conduit cement. The conduit must be the same diameter as the service lateral conduit. All conduit bends must have a minimum .

frame tube, braced tube, bundled tube, tube in tube, and tube mega frame structures. The tube in tube structures and tube mega frame structures are the innovative and fresh concept in . These tubes are interconnected by system of floor slabs and grid beams.as the columns of outer and inner core tubes are placed so closely; it is not seen as a .

system between Tube in Tube system and Bundled tube system. The ETABS models of Tube in Tube and Bundled tube system which is G 20 Terrace storey, are considered for analysis. The modeling and analysis of the building has been done by using structure analysis tool ETABS2018.both the building models are subjected to gravity as well as seismic