Linear Acoustic ARC(Automatic Realtime Control)Next Generation Television Loudness ProcessorOVERVIEWThe Linear Acoustic ARC is a budget-friendly, easy-to-use, 2-channel television processor specificallydesigned for regions and applications that do not require support for multi-channel, coded audio, butwhere no-compromise audio quality is valued.

TelosAlliance.com/Linear/ARCARC Next Generation Television Loudness ProcessorFEATURES Audio processing using the Linear Acoustic APTO loudness adaptation algorithm Compliance for any loudness recommendation or regulation including EBU R 128 andATSC A/85 (CALM) Processing for two PCM stereo or mono program streams Ability to specify target loudness and True Peak values 3Gb/s HD/SD-SDI and AES-3 I/O AES67 I/O supports SMPTE ST 2110-30 workflows Rolling 6-hour loudness logging for each program Separate loudness event log to easily identify loudness issues plus system event log System event log SNMP Dual internal redundant auto-ranging power supplies Browser-based remote controlIN DEPTHThe Right Features at the Right PriceUntil now, broadcasters looking for a straightforward, stereo, television processor had to make somedifficult compromises.Less costly solutions were budget-friendly, but the savings came at the expense of audio quality.Products that delivered excellent audio performance also included features such as support for multichannel, coded audio and audience measurement watermarking that simply aren’t required in manyregions – and with a price tag that put them out of reach to smaller broadcasters.Linear Acoustic ARC eliminates that compromise by offering a 1RU DTV audio processor for twoindependent PCM stereo or mono program sources that delivers the viewer-pleasing audio upon whichLinear Acoustic has built its reputation.

TelosAlliance.com/Linear/ARCARC Next Generation Television Loudness ProcessorAPTO ProcessingARC features the Linear Acoustic APTO loudness adaptation algorithm which carefully controls levels ina way that preserves transients, sonic image, and the artistic intent of the original audio source whilestill ensuring full compliance with any loudness recommendation or regulation including EBU R 128 andATSC A/85 (CALM).Simple, Straightforward SetupSetting up ARC couldn’t be simpler: Select a suitable adaptation profile for your programming fromthe ample list of factory presets, adjust a single control to determine the amount of overall processingdesired, set the desired loudness target, and walk away with confidence.A front panel navigation cluster is used for initial setup, while a web-based, browser- and OS-agnosticremote user interface makes more detailed setup and monitoring easy and convenient on any computeror mobile device. A front panel color LCD display clearly shows audio levels and loudness information.Ready for Today, Ready for the FutureI/O includes AES-3, 3Gb/s HD/SD-SDI, and AES67, making ARC suitable for use in today’s typicalbroadcast facilities, but also compliant with SMPTE ST 2110-30.SPECIFICATIONSProcessing Linear Acoustic APTO Loudness Adaptation algorithm; processing for two stereo or mono programsLogging Rolling 6-hour loudness logging for each program Separate loudness event log to easily identify loudness issues System event logAES-3 I/O One 2-channel input and one 2-channel output via 75 Ohm BNC female connectors, internallyterminated; signal levels per SMPTE 276M/AES-3ID-2001SDI I/O One auto-sensing 3Gb/s HD/SD-SDI (SMPTE ST425/292M/259M) input and one output via 75 OhmBNC female connectors, internally terminated; video formats up to 1080p/60/59.94/50Hz

TelosAlliance.com/Linear/ARCARC Next Generation Television Loudness ProcessorAES67 I/O 16-channels of bi-directional AES67 I/O in support of SMPTE ST 2110-30 workflowsReference 48kHz reference via SDI, PTP, AES-3, or internal clockSample Rate/Resolution/Frequency Response 48kHz, 24-bit, 20Hz – 20kHzEthernet Two Gigabit RJ-45 connections – one for AES67, one for networked remote controlParallel GPI/O Control Port 15-pin female D connector, 0-5V TTL levels, 5 GPI/O inputs, 5 GPI/O outputSNMP Traps include loudness above/below target, loudness within target window, change in reference, andpower supply statusFront Panel Controls and Indicators 5-key navigation cluster; graphical color LCD display; LED status indicators for each power supply,system status, and referencePower Dual internal redundant auto-ranging power supplies, each rated at 100-264VAC, 50/60Hz, 40 WattsmaximumDimensions and Weight 19” W x 9” D x 1.75” H (approximately 48.2 x 22.9 x4.5 cm ) Net weight: Approximately 9.0 lbs (4.08 kg) Shipping weight: Approximately 12.0 lbs (5.44 kg)

TelosAlliance.com/Linear/ARCARC Next Generation Television Loudness ProcessorEnvironmental Operating: 0 to 50 degrees C Non-Operating: -20 to 70 degrees CIntended Location Telecommunications center or dedicated computer/machine roomRegulatory North America – FCC and CE tested and compliant with UL-approved power supplies Europe – Complies with European Union Directive 2002/95/EC on the restriction of use of certainhazardous substances in electrical and electronic equipment (RoHS), as amended by CommissionDecisions 2005/618/EC, 2005/717/EC, 2005/747/EC (RoHS directive), and WEEEWarranty Standard Telos Alliance 2-year limited parts and laborTHE TELOS ALLIANCE 1241 SUPERIOR AVENUE CLEVELAND, OH 44114 USAMAIN: 1.216.241.7225 24/7 SUPPORT: 1.216.622.0247 TELOSALLIANCE.COM 2020 TLS CORP. ALL RIGHTS RESERVED. L20/2/18180

Linear Acoustic ARC (Automatic Realtime Control) Next Generation Television Loudness Processor OVERVIEW The Linear Acoustic ARC is a budget-friendly, easy-to-use, 2-channel television processor specifically designed for regions and applications that d

Related Documents:

For Reference Only ARC 8D ARC 10D ARC 12D ARC 15D Dimensions And Specs 1 Recommended Enclosures ARC 8D 2 ARC 10D 2 ARC 12D 3 ARC 15D 3 . .65 cu.ft. .75 cu.ft. .85 cu.ft. Minimum SPL SQ ARC 10D2 ARC 10D4. 3 TOP NOTE: These woo

High Current Level Arc "Parallel Arc" An Arc Fault That Occurs at 75Amps and higher An Arc Fault That Occurs Line-Line or Line-Neutral Types Of Arcing Faults Low Current Level Arc "Series Arc" An arc fault at low levels down to 5 Amps An arc fault at a break or gap in a single conductor in series with a connected load

Arc Flash Facts Arc Flash Fact Sheet Brady Arc Flash Training Aids Promote awareness of the dangers associated with arc flash accidents and make sure your workers know how to protect themselves! Poster Highlights the common causes of arc flash and provides safe work practices and personal protection equipment requirements

HMP presents a wide range of AR -200 or MMA-200 of 200 AMP single phase inverter welding machine. These ARC Welding machines are available in various model ranges. HMP have a wide range of 200A ARC inverter welding machine with all standard accessories. HMP have 200A models of Welding as ARC-200N, ARC-200G, ARC-200MOS, ARC-200L, ARC-

Apr 30, 2008 · Carbon Arc Cutting/PACCarbon Arc Cutting/PAC 16 16 Hardfacing 10 Wee d g ( ot de ed & ed)lding (not defined & mixed) 21 . GTAW Gas-Tungsten Arc Welding (TIG) GMAW Gas-Metal Arc Welding (MIG) SMAW Shielded Metal Arc Welding (Stick or Manual Arc Welding) FCAW Flux Core Arc Welding. Step 2: Filler Metal/Base Metal .

130.5 Arc Flash Risk Assessment. An arc flash risk assessment shall be performed and shall: (1) Determine if an arc flash hazard exists. If an arc flash hazard exists, the risk assessment shall determine: a) Appropriate safety-related work practices b) The arc flash boundary c) The PPE to be used within the arc flash boundary

130.7(C)(15)(b) specify arc flash PPE category 1 or 2b Arc Flash Suit A total clothing system consisting of arc-rated shirt and pants and/or arc-rated coveralls and/or arc flash coat and pants (clothing system minimum arc rating of 40) Situations where a risk assessment indicates that PPE is required and where Table 130.7(C)(15)(a) and table .