Inlet Covers TE05C TE05C L.S. Inlet Cover With Compensator .

2y ago
27 Views
2 Downloads
1.21 MB
15 Pages
Last View : 6d ago
Last Download : 3m ago
Upload by : Melina Bettis
Transcription

1.06TIIT1PTL ON-OFF drain valveLS116 4.5713MAX 68 2.6848 1.894PLSLS1P127 1.0654 2.13TLLT1P398SBW078EN01 - 23-07-2019T11

TE05C Type of unloading valve on LS lineG With unloading valveLS154.3 6.08106.3 4.19P48 1.89LSLS1P127 1.0654 2.13TGGT1PTWith choices A - B - G - H, it is necessary to insert a drain valve on the LS line in the outlet cover to ensurethe correct operation of the distributor.12398SBW078EN01 - 23-07-2019

TE05CEmergency unloading valve on LS lineO Standard terminalS Manual override with screw154.3 6.08106.3 4.19185.2 7.29MAX 137.2 5.448 1.8948 1.89Electrical characteristics of the unloading valve coilVoltage1224V ( 10%)Resistanceat 20 C7,732Ω ( 7%)Rated current1,550,75APower18,618W398SBW078EN01 - 23-07-201913

TE05C 1Instructions for ordering23456789101112131415 16TE05C1Thread typeF Female2Thread port PA 3/8'' GAS ISO 1179B 1/2'' GAS ISO 1179C M18x1.5 ISO 9974N M22x1.5 ISO 9974W M18x1.5 ISO 6149J M22x1.5 ISO 6149E 3/4'' - 16 SAE ISO 11926R 7/8'' - 14 SAE ISO 119263Thread port TA 3/8'' GAS ISO 1179B 1/2'' GAS ISO 1179C M18x1.5 ISO 9974N M22x1.5 ISO 9974W M18x1.5 ISO 6149J M22x1.5 ISO 6149E 3/4'' - 16 SAE ISO 11926R 7/8'' - 14 SAE ISO 119264Thread port LSL 1/4'' GAS ISO 11793K M14x1.5 ISO 6149P 9/16'' - 18 SAE ISO 119265Options on ports P - T - LSA P-T-LS openB P-T open, LS pluggedE P-LS plugged, T open6Options on P-T-LS linesS StandardA P-T-LS throughB With TE05P7Main Compensator optionN NoneR Regulation with grub screwV Regulation with handwheelBracket heightH2 StandardH3 High10Thread port MPN NoneQ 1/8'' GAS ISO 117911Thread port MTN NoneQ 1/8'' GAS ISO 117912Options on ports MP - MTN NoneA MP open, MT Not machinedplugged, MT notB MPmachinedE MP and MT open13Type of unloading valve on LS lineI Drain valveA 12V DIN 43650L ON-OFF drain valveB 24V DIN 436508149M14x1.5 ISO 9974NN NoneF MP and MT pluggedG 12V DEUTSCH DT04-2PH 24V DEUTSCH DT04-2P398SBW078EN01 - 23-07-2019

TE05CInstructions for ordering1714Emergency unloading valve on LS lineN NoneO Standard terminalS Manual override with screw15 16Type of pressure relief valve00 Replacement cap VMP05 50 bar06 60 bar07 70 bar08 80 bar09 90 bar101112131415161718192021External treatmentN NoneZ Zinc plating17100 bar110 bar120 bar130 bar140 bar150 bar160 bar170 bar180 bar190 bar22232425220 bar230 bar240 bar250 bar200 bar210 bar398SBW078EN01 - 23-07-201915

4 398SBW078EN01 - 23-07-2019 TE05C Thread ports Thread port P Code Type Tightening 10% Nm A 3/8'' GAS ISO 1179 45 B 1/2'' GAS ISO 1179 70 C M18x1.5 ISO 9974 45 N M22x1.5 ISO 9974 70 W M18x1.5 ISO 6149 45 J M22x1.5 ISO 6149 70 E 3/4'' - 16 SAE ISO 11926 45 R 7/8'' - 14 SAE ISO 11926 70 Thread port T Code Type Tightening 10% Nm A 3/8'' GAS ISO 1179 45

Related Documents:

D-44 Standard Double WR Inlet D-45 Standard WRM Inlet D-46 Standard Single WR Inlet D-47 “S” Grate Details D-48 Standard WR Inlet Frame & Grate D-49 Standard WR Inlet Frame & Grate D-50 Yard Type Inlet D-51 Inlet Depression Detail D-52 Typical Infiltration Structure D-52A Typical Infiltration Structure (From Roof Leaders of Building)

August 2013 Urban Drainage and Flood Control District IP-1 Urban Storm Drainage Criteria Manual Volume 3 Photograph IP-1. Inlet protection for a curb opening inlet. Description . Inlet protection consists of permeable barriers installed around an inlet to filter runoff and remove sediment prior to entering a storm drain inlet. Inlet

media volume. Regulator shall have one piece diaphragm subassembly, and trim that can be replaced inline without dome/spring chamber disassembly. outlet inlet outlet gage inlet gage * Gage ports are 1/4" FNPT. Consult factory for Tri-clamp, VCR or other alternatives, or porting options. A B D E outlet inlet outlet inlet outlet inlet inlet gage .

From St. Augustine Inlet to Ponce de Leon Inlet the coast continues straight, broken only by Matanzas Inlet. The 5 -fathom curve is within 0.5 mile of the shore except off St. Augustine Inlet and Matanzas Inlet. Numerous marked and u nmarked fish havens are as much as 18 miles offshore.

It is inferred that, the inlet manifold with buttress threads gives better performance and yields less exhaust emissions compared to inlet manifolds with acme and knuckle threads. This is because inlet manifold with buttress threads achieved a higher swirl coefficient and swirl ratio compared with inlet manifolds having acme and knuckle threads.

Unimaster Dust Collectors. Unimaster Offers: . URE AT COLLECTOR INLET "w g S TATIC PRE SS URE AT COLLECTOR INLET "w g S TATIC PRE SS URE AT COLLECTOR INLET "w g S TATIC PRE SS URE AT COLLECTOR INLET "w g S TATIC PRE SS URE AT COLLECTOR INLET "w g 2 HP 7.5 HP 10 HP 15 HP 20 HP 30 HP

The first model used a cylindrical basin with a tangential inlet channel; in turn, the second model was based on a cylindrical basin with a wrap- around inlet channel; the third model used a conical basin with a tangential inlet channel; and, finally, the latter one used a conical basin with a wrap-around inlet channel.

Literary Studies. London: Longman, 1993. INTRODUCTION While most of you have already had experience of essay writing, it is important to realise that essay writing at University level may be different from the practices you have so far encountered. The aim of this tutorial is to discuss what is required of an English Literature essay at University level, including: 1. information on the .