showsall its sensor typesULTIMA X3 monitor operates as slavedevice on the networkOptional remote sensor installationallows for a maximum distance of 15 mfor each sensorInternal relays can be configured for3 different common alarms or oneindividual alarm for each sensor[ ModBUS Network Example ]ModBUSmasterunit 18unit 2unit 31

[ 3 Sensor Technologies x 31 Monitors 93 Gas Sensors ]9

[ Accessories ]CalibratorControllerThe easy to use 3 button ULTIMACalibrator, with IR interface, offersthe industry’s simplest methodof calibration. The intrinsicallysafe Calibrator can also be usedto change the address of anULTIMA X3 gas monitor.The ULTIMA Controller has an IRinterface and provides completeaccess to all features through itsfull function keypad.Push Button [external]Flow through AdaptorThe push button allows for quickbrowsing through key functionswithout the calibrator:For toxic and catalytic sensorswith connection for option toapply calibration gas remotely[for ULTIMA XE].nnnnnAcknowledge AlarmsZero CalibrationSPAN CalibrationInitial Calibration [iCAL]Abort CalibrationFeatures include:n Intrinsically safen Set/display alarm levelsn Set/display SPAN gas valuen Display minimum, maximumand average gas readingsn Calibration menuRemote Sensor OptionsFlow CapUsed when there is a requirementto pump a sample through thesensing module [for ULTIMA XIand XIR].10The optional explosion-proof[NPT] or increased safety [metric]enclosure includes a terminalstrip for easy wiring of power andsignal.

[ Technical Specifications ]Gas TypesCombustibles, toxics and oxygenTemperature Range--40 C to 60 C [--40 F to 140 F][typical, range for some gases maydiffer]DriftZero DriftSpan Drift 5% per year, typical 10% per year, typicalAccuracyRepeatability 1% Full Scale or 2 ppm, typicalLinearity 2% Full Scale or 2 ppm[O2, CO], typical 3% Full Scale [ 50% LEL combustibles] 5% Full Scale [ 50% LEL combustibles] 10% Full Scale or 2 ppm[non-CO toxics], typicalResponse Timesτ 20 oxygen and toxicsτ 50 oxygen and toxicsτ 50 combustiblesτ 90 combustiblesτ 90 XIR 12 seconds [typically 6 seconds] 30 seconds [typically 12 seconds] 8 seconds 20 seconds 5 seconds [without sensor guard]Humidity15% – 95% RH, non-condensingSensor LifeOxygen and toxicsCombustibles2 years typical3 years typicalPower Input24 VDC [oxygen]24 VDC @ 450 mA maximum[combustibles]24 VDC @ 750 mA maximum [XIR]Wiring RequirementsCombustibles [incl. XIR] 3-wireOxygen and toxics2-wire; no LEDs or relaysOxygen and toxics3-wire; LEDs and/or relaysSignal OutputULTIMA XERelay ContactsRatingAlarmFault4 – 20 mA 2-wire current sink4 – 20 mA 3-wire current source5 A @ 220 VAC; 5 A @ 30 VDCnormally energised/de-energised,SPDT, upscale/downscale,latching/nonlatchingnormally energised, SPDT,non-latchingCable EntriesFour, 3/4 inch NPT or 25 mmPhysicalWeightDimensionsMaterial4.7 kg261 x 160 x 99 mm [H x W x D]316 Stainless SteelApprovalsULTIMA XE/XIR/X3ULTIMA XE/XIR/X3and Remote SensorULTIMA XE/XIR/X3CE Low Voltage Directive: 73/23/EECCE ATEX Directive: 94/9/ECCE EMC Directive: 89/336/EECII 2G EEx d IIC T5 [main enclosure]II 2G EEx d IIC T4[sensor excluding IR]II 2G EEx d IIC T5 [IR sensor]II 2G EEx ia IIC T4[sensor with safety barrier]--40 C Ta 60 CEC-Type Examination CertificateDMT 02 ATEX E 202 XULTIMA XE/XIRPerformance approvalEN 60079-29-1:2007EN 50104:2002 [PFG-No. 41301103P]EN 50271:2002ULTIMA CalibratorII 2G EEx ib IIC T3/T4/T5ULTIMA ControllerII 2G EEx ib IIC T4Warranty24 months on all components includingIR sensor [does not include catalytic orelectrochemical sensor modules]11

[ Sensor & System Options ]nnn Infrared Sensorsfor monitoring group3 or 4 combustibles[ List of Combustible Gases, Catalytic Sensor ]Compoundnnn Electrochemical Sensorsfor monitoring varioustoxics and oxygennnn Catalytic Sensorfor monitoring group 1and 2 combustiblesnnn ULTIMA X3for up to 3 sensors with1 monitor includingremote sensors12AcetaldehydeAcetic AcidAcetoneAcetyleneAcrylnitrileAmyl -1Butene-2Butyl AcetateButyl AcrylateButeneButyraldehydeCyclohexaneDiethyl EtherDimethoxyethaneDimethyl EtherDioxane-1,4EthaneEthanolEthyl AcetateEthyl AcrylateEthyl BenzeneEthyleneEthylene thaneMethanolMethyl AcetateMethyl Ethyl KetoneMethyl Isobutyl KetoneMethyl MethacrylateMethyl Propane-2Methyl t-Butyl oPropanol-nPropyl AcetatePropylenePropylene 2222121111222122222[ List of Combustible Gases, IR Sensor ]CompoundGroupAcetone3Allyl hexane4Cyclopentane4Diethyl Ether4Difluoroethane-1,1[R 152a]4Dimethylamine4Dimethyl Ether4Epichlorohydrin4Ethane3Ethanol4Ethyl Acetate4Ethylene3Ethylene anol4CompoundGroupIsopropyl Acetate4MEK4Methane3Methanol4Methyl Chloride4Methylene ionaldehyde4Propyl Acetate4Propylene3Propylene ane-1,1,1 4Triethylamine4Trimethylamine4Vinyl Acetate4Xylenes [O-Xylene]4

[ Ordering Information ]Cable Gland Thread Type3/4 NPT25 mm metricEnclosure TypeEnclosure without terminal stripsEnclosure with terminal stripsGas TypeInfrared SensorsIR Sensor for Combustible Gases, Group 3*: 0 – 100% LELIR Sensor for Combustible Gases, Group 4*: 0 – 100% LELCatalytic SensorsCatalytic Sensor for Combustible Gases, Group 1*: 0 – 100% LELCatalytic Sensor for Combustible Gases, Group 2*: 0 – 100% LELElectrochemical SensorsAmmonia0 – 50 ppmAmmonia0 – 100 ppmArsine0 – 2 ppmBromine0 – 5 ppmCarbon Monoxide0 – 100 ppmCarbon Monoxide0 – 500 ppmChlorine0 – 5 ppmChlorine Dioxide0 – 3 ppmDiborane0 – 50 ppmEthylene Oxide0 – 10 ppmFluorine0 – 10 ppmGermane0 – 3 ppmHydrogen0 – 1000 ppmHydrogen Chloride0 – 50 ppmHydrogen Cyanide0 – 50 ppmHydrogen Sulphide0 – 10 ppmHydrogen Sulphide0 – 50 ppmHydrogen Sulphide0 – 100 ppmNitric Oxide0 – 100 ppmNitrogen Dioxide0 – 10 ppmOxygen0 – 10%Oxygen0 – 25%Phosphine0 – 2 ppmSilane0 – 25 ppmLED/Relay/Output OptionsULTIMA XE/XIRULTIMA XE/XIRULTIMA XE/XIRULTIMA XE/XIRULTIMA XE/XIRULTIMA X3 ModBUS-PCBULTIMA X3 ModBUS-PCBULTIMA X3 ModBUS-PCBULTIMA X3 1004452310044436100444381004445110044453no LEDs and no relays, 2-wire output[only for toxics, not for combustibles]no LEDs and no relays, 3-wire outputLEDs and no relays, 3-wire outputRelays and no LEDs, 3-wire outputLEDs and relays, 3-wire outputno LEDs and no relaysLEDs and no relaysRelays and no LEDsLEDs and 2613100626141006261510062616Installation OptionsInstrument mounting bracketHousing for remote sensor installation, 3/4" NPTHousing for remote sensor installation, 25 mm metricReducer M25/M20 EEx deCable Gland M20 EEx esULTIMA ControllerULTIMA CalibratorReset push button [external]ULTIMA XE Calibration capULTIMA XE Flow adapterULTIMA XE SensorGardULTIMA XIR Calibration capULTIMA XIR Flow capULTIMA XIR 10028904100415331004260010041265*Please see specifications. More gas types, options and accessories available on request.Please choose fromthe options to createyour ULTIMA X13

Your direct contactSubject to change without notice. ID 07-703.2 GB/03

ULTIMA X3 Technology [Digital Data Transfer and up to 3 Sensors per Monitor] The ULTIMA X3 has all the benefits of the ULTIMA X series and is also capable of digital communication. A maximum of 31 ULTIMA X3 transmitters can be connected to the same line via ModBUS RTU. Since ULTIMA X3

Related Documents:

ULTIMA X3 Technology [Digital Data Transfer and up to 3 Sensors per Monitor] The ULTIMA X3 has all the benefits of the ULTIMA X series and is also capable of digital communication. A maximum of 31 ULTIMA X3 transmitters can be connected to the same line via ModBUS RTU. Since ULTIMA X3

ULTIMA Repair Kit P80KV8 (Viton Seals) T o pr o te c t y our W a r a n t y l U s e o nlyEn e r p a c O i See on last page. T o pr o te c t y our W a r a n t y l U s e o nlyEn e r p a c O i See on last page. 4 Item included in: ULTIMA Repair Kit P80K8 (Standard Seals) ULTIMA Repair Kit P80KV8 (Viton Seals) ULTIMA Release Valve Kit P39RVK

Ultima X3 Technology (X to the Power of 3) Ultima X3 Technology for Ultima X Series Gas Monitors features: Multi-sensing Up to 31 monitors with up to 3 sensors inputted per monitor for 93-sensor total Combination of electrochem

MSA Safety Regulations ULTIMA X GB Series 15 1 Safety Regulations 1.1 Correct Use The ULTIMA X Series Gas Monitors are fixed Gas Monitors for measuring toxic and combustible gases as well as oxygen. They are suitable for outdoor and indoor applications without lim ita

FOR INDUSTRIAL HEATING OF AIR AND GAS UP TO 800 C (1470 F) Traditional heating cassettes are commonly equipped with tubular heating elements as the heating source. The design of these elements limits the maximum reachable air/gas temperature to about 600 C (1110 F). With the state of art heating element design used in our Kanthal heating .

ULTIMA #53-644 Programmable Digital Ignition System DESCRIPTION The Ultima Digital Ignition is designed to provide the correct curves and total timing for Ultima enginesand other larger cubic inch or high performance engines. These units will also replace the OEM HD factory ignition module and sensor used on 1983 and later Harley-Davidson EVO motors.

District heating often involves a heating substation installed in the basement of a building. It receives the heating carrier from a heat generating station and via a heat exchanger makes it available for the building heating system. An individual heating system in many cases consists of a boiler heating water up to required temperature for

ISO 14001:2015 EMS Manual Insert your company’s name or logo, and address. This EMS manual is the property of Your Company. It must not be reproduced in whole or in part or otherwise disclosed without prior written consent. The official controlled copy of this EMS manual is the digitally signed PDF document held within network server and visible to all authorised users. All printed copies .