2015 WINSTED CORPORATIONEMAIL: info@winsted.com WEB: winsted.com TEL: 800.447.2257 or 952.944.9050 FAX: 800.421.3839 or 952.944.154610901 Hampshire Ave. So. Minneapolis, Minnesota 55438-2385 U.S.AMODEL: ENVISION COMMAND CONSOLES1) GENERAL DESCRIPTION1.1 EnVision Command Consoles see Appendix “A,B,Cand D” for typical styles and measurements.1.2 The contractor shall supply a system capable ofsupporting specified electronics.1.3 The system shall be comprised of vertical supportlegs with horizontal slat-wall and work surfacesupport tray.1.4 The system shall have a minimum 1-1/8” (29mm)thick industrial grade 45 lb. particle board corework surface with a protective rubber SafeguardT-edge. The work surface shall be 22-3/4” (578mm)deep overall and finished with a high pressurelaminate on top and warp resistant backer on thebottom.2) STANDARDSmodel numbers.4.3 Free from alterations to the design either prior to orfollowing installation, will be accomplished withoutthe need for either welding or carpentry work.4.4 Constructed of a steel super-structure frameworkconsisting of vertical support legs with horizontalslat-wall and work surface support tray.5) SELF SUPPORTING SKELETON FRAMEWORKThe self supporting skeleton framework shall:5.1 Be installed at the site in advance of any externalfinishing panels. finishing panels. The frameworkshall be fully capable of supporting all specifiedelectronics without the need for attachment of anyexternal panels.5.2 Be capable of being supplied to site in knockdown2.1 Optional rack mount turret shall comply withElectronic Industry Association (E.I.A.) specificationsfor rack mounting ANSI/E standard RS-310.2.2 All monitor mounts used with the integratedVersa-Trak mounting system are compliant with theMounting Interface Standard established by theVideo Electronics Standards Association (VESA).3) DRAWINGS(flat packed) form and be capable of assemblywithout welding or carpentry work.5.3 Include vertical support legs constructed of 16gauge* (.060”) formed sheet metal. Horizontalslat-wall sections and work surface support traywill connect and span support legs to form acomplete structure.6) COMPONENTS6.1 VERTICAL SUPPORT LEGS3.1 The contractor shall supply five sets of scaleddrawings for each console assembly showing thelocation of all the specified electronics in isometricview in addition to a plan (top) and front views.3.2 The specification of sizes and dimensions shown int he drawings shall have a tolerance of not morethan /- 0.062” (1.6mm).4) MODULAR PRE-ENGINEERED CONSTRUCTIONAll components within the system shall be:4.1 Of a pre-engineered modular construction, ie:constructed from a series of independent sectionalcompartments.Section: A84.2 Available from a pre-defined set of manufacturers16 gauge (.060”) vertical support legs shall be aminimum of 5” (127mm) in width and capable ofsupporting fully loaded console. Support legs shallfeature a front and rear anti-tip extension, grommetholes, 2-1/2” (64mm) diameter glides and removablerear access panels for cable management.6.2 WORK SURFACE SUPPORT TRAY14 gauge (.074”) metal horizontal support tray shallbe 1-1/4” (32mm) high and available in 20-1/4”(514mm), 38-1/4” (972mm), and 62-1/4” (1581mm)widths.6.3 CORNERSCorner angles will not be predefined by standardcorner sections. Corner angles will be definedby the work surface and can be custom configuredas needed to fit the application.WINSTED CORPORATION GENERAL A&E SPECIFICATIONSPage: 1

ARCHITECT AND ENGINEER SPECIFICATIONS6) COMPONENTS (CONT.)9) MOUNTING HARDWARE6.4 LIFT-OFF CABLE TRAY9.1 Mounting hardware for the specified electronics18 gauge (.048”) 4” deep horizontal cable tray shallattach to the rear of the slat-wall, no tools requiredto mount. Cable tray shall feature integrated lacingloops for large cable bundles.6.5 SLAT-WALL MOUNTING SYSTEMFully integrated clear anodized aluminum slat-wallcapable of supporting a wide variety of monitormounts and standard slat-wall accessories. Theslat-wall shall be constructed of extruded 6105-T5aluminum with a double-walled vertical columnand mounting channels on the front and backof the wall. The slat wall shall consist of one or two7-1/2” (191mm) high panels for an overall heightof 7-1/2” (191mm) or 15” (381mm) and an overalldepth of 1-3/16” (30mm). The channel openings shall be 1-1/2” (38mm) on center, 3/4” (19mm) wide,7/16” (11mm) deep on the front and 1/4” (6mm)deep on the back. Slat-wall mounting bracketsallow for vertical and horizontal adjustment.7) FINISH AND COLOR7.1 All exterior and frame steel components shall beclear anodized or zinc oxide wash primer with ablack powder coat textured finish.8) OPTIONAL ACCESSORIESshall be available upon request. All hardwareneeded for assembly will be provided.10) INSTRUCTIONS10.1 Fully detailed assembly instructions in the Englishlanguage shall be supplied with both written andpictorial descriptions for each item/modelnumbered component.11) PACKAGING11.1 Each component part number shall be independentlymarked and packed into double or triple plycorrugated outer cartons and shall be suitable forstorage and shipping to site without damage.12) WARRANTY12.1 A LIFETIME WARRANTY on all fixed steelstructure frame components. A 10 year warranty on adjustable, sliding orhinged components and laminated surfaces. A 5 year warranty on Endurance Plus andTruForm surfaces. A 2 year warranty on all electrical componentsand chairs.8.1 A full range of optional accessories shall beavailable such as phone trays, electrical outlets,CPU mounts, rack mount turrets, monitor mounts,and LED task lighting.*American Standard Wire Gauge (ASWG).Section: A8WINSTED CORPORATION GENERAL A&E SPECIFICATIONSPage: 2

ARCHITECT AND ENGINEER SPECIFICATIONSMODEL: ENVISION COMMAND CONSOLES (CONT.)Ref: 6.3CornersRef: 6.5Slat-WallMountingSystemRef: 1.422-3/4” DeepLaminate WorkSurfaceRef: 6.2Work SurfaceSupport TrayRef: 6.1Vertical Support LegsWith Anti-Tip ExtensionsRef: 8.1AdjustableMonitor MountsRef: 2.1Optional RackMount TurretRef: 8.1OptionalTask LightRef: 7.1Finish AndColorRef: 6.4Lift-offCable TrayRef: 6.1Anti-TipExtensionsAPPENDIX ASection: A8WINSTED CORPORATION GENERAL A&E SPECIFICATIONSPage: 3

ARCHITECT AND ENGINEER SPECIFICATIONSMODEL: ENVISION COMMAND CONSOLES (CONT.)42” CHASE m)60” CHASE )43.71”(1110mm)22.75”(578mm)84” CHASE m)22.75”(578mm)APPENDIX BSection: A8WINSTED CORPORATION GENERAL A&E SPECIFICATIONSPage: 4

ARCHITECT AND ENGINEER SPECIFICATIONSMODEL: ENVISION COMMAND CONSOLES (CONT.)ERGONOMIC DETAIL43-11/16”(1110mm)Monitor MountOptionalSecond TierSlatwall(15”H Slat-Wall Shown)LaminatedWork SurfaceWith SafeGuard Edge22-3/4”(577mm)CableRaceway34 Cable TrayCableAccess ”(903mm)APPENDIX CSection: A8WINSTED CORPORATION GENERAL A&E SPECIFICATIONSPage: 5

ARCHITECT AND ENGINEER SPECIFICATIONSMODEL: ENVISION COMMAND CONSOLES (CONT.)ERGONOMIC DETAILUpper Visual Limit50 25 Optional 2nd TierEasy Eye Rotation4’(1219mm)TypicalEye Height35 Monitors Are LoweredTo Maximize mm)HeightKnee SpaceMin. Rec. 25”43-5/8”(1109mm)Min. KneeSpace 18”APPENDIX DSection: A8WINSTED CORPORATION GENERAL A&E SPECIFICATIONSPage: 6

1.1 EnVision Command Consoles see Appendix “A,B,C and D” for typical styles and measurements. 1.2 The contractor shall supply a system capable of supporting specified electronics. 1.3 The system shall be comprised of vertical support legs with horizontal slat-wall and work surface support tray. 1.4 The system shall have a minimum 1-1/8 .

Related Documents:

Fallen Leaves 7231-58 New Leaves 7335-58 Carrara Envision 7494-58 Pebble Envision 7495-58 Saltillo Envision 7497-58 Folkstone American Granite 658-90 Omega Granite 3177-58 Jasper Envision 7499-58 Lapis Envision 7498-58 Noir Envision 7500-58 Lime Stone 7264-58 Sand

Command Library - String Operation Command Command Library - XML Command Command Library - Terminal Emulator Command (Per Customer Interest) Command Library - PDF Integration Command Command Library - FTP Command (Per Customer Interest) Command Library - PGP Command Command Library - Object Cloning

Envision credits and laying the foundation for Envision v3. The work of the technical committees was then carried forward by ISI staff and the Envision Review Board, a group of industry-leading professionals accountable to the ISI Board of Directors for maintaining the integrity of the Envision framework.

4 enVision 2.0 5-4 Use Partial Quotients to Divide ENV TE p. 257 5 enVision 2.0 5-5 Divide by Multiples of 10 ENV TE p. 263 6 enVision 2.0 5-6 Use Estimation to Place the First Digit of the Quotient ENV TE p. 269 7 enVision 2.0 5-7 Divide by 2-Digit Divisors ENV TE p. 275 8 Georgia Are These All 364/15 Unit p. 9 9

For model(s): enVision 375, enVision 750 & Odyssey Brand: Gerber Degree: 30 General Description: 30 degree blade used for 1-4 mil vinyl and thinner materials. Package Quantity: 2. P63680B For model(s): enVision 375, enVision 750 & Odyssey Brand: Gerber Degree: 60

If upgrading the functionality of dispatch consoles is your priority, start by replacing some or all of your existing circuit-switched consoles. Begin by: Deploying an ASTRO 25 core system Deploying one or more Motorola MCC 7500 and/or MCC 7100 Consoles Integrating the new consoles into your existing network infrastructure

Gerber Emboss Track24 Emboss Track36 Emboss Track48 FasTrack 550 FasTrack 650 FasTrack 750 FasTrack 1000 FasTrack 1300 GS 15 Plus HP/GL . Envision 750-HPGL Envision 375-HPGL Envision 750 Envision 375 Esprit 850 Esprit 1400 P2C 600 P2C 1200 P2C 1600 Tempo-600 GerCutter-Laser Manufacturer Model CT-630 CT-900

MOUNT ASPIRING COLLEGE DEPARTMENT OF ENGLISH - FEMINIST LITERARY CRITICISM - PAGE !3 OF !7. WHAT MARXIST CRITICS DO TAKEN FROM BEGINNING THEORY, BY P. BARRY2: 1. They make a division between the ‘overt’ (manifest or surface) and ‘covert’ (latent or hidden) content of a literary work (much as psychoanalytic critics do) and then relate the covert subject matter of the literary work to .