Agilent 4395A Network/Spectrum/Impedance Analyzer 500

2y ago
36 Views
3 Downloads
895.77 KB
16 Pages
Last View : 6d ago
Last Download : 3m ago
Upload by : Warren Adams
Transcription

Agilent4395A Network/Spectrum/Impedance Analyzer500 MHz4396B Network/Spectrum/Impedance Analyzer1.8 GHzTechnical OverviewNew Approach toElectronic Componentand Circuit EvaluationA new concept in testing that combinesthe power of a vector network analyzer,a spectrum analyzer, and an optionalimpedance analyzer.Take an innovative approach toevaluating electronic componentsand circuits. The Agilent Technologiescombination analyzers family combinesthree analyzer functions in onepowerful instrument: a vector networkanalyzer, a spectrum analyzer, andan optional impedance analyzer.Now you can use one analyzer formultiple testing needs.Because many electronic componentssuch as amplifiers require both vectornetwork and spectrum parameters, youneed a combination analyzer to meetnew testing requirements such as: Measuring intermodulationdistortion and phase performanceof components used in digitalcommunication systems. Characterizing monolithic IC’s orcircuit blocks.Compared with using separateanalyzers, you save equipmentcost and bench space with theAgilent 4395A/96B, and avoidtime-consuming and messy signalcabling to multiple instruments.

Introducing the Agilent 4395AAn integrated solution deliveringexceptional performance andhigh value to 500 MHzColor TFT (thin film transistor) LCD withdual display Split-screen viewing for twoindependent channels VGA output for external monitorTwo independent channels provideflexibility Test both parameters in yourselected analyzer mode (vectornetwork, spectrum, or optionalimpedance) Get real-time data throughfast alternate sweepsPowerful calibration/ compensationThree analyzer functionsgive you maximumflexibility. Jump fromone type of measurement to another withthe push of a button.Vector networkand high sensitivespectrum inputports offer: R, A, B portsfor transmissionand reflectionmeasurements R, A, B ports forhigh sensitivityspectrummeasurements 75 Ω impedanceconversion(Option 4395A-1D7)Fast sweepimprovementsthroughoutDC source(Option 4395A-001)1.44 MB floppy disk drivelets you save and recall ineither LIF or MS-DOS format: Test setups Calibration data Measurement data IBASIC programs Graphic (TIFF) filesTest sets and accessories give youmeasurement options in 50 Ω or 75 Ω Agilent 87511A/B S parametertest set2Markers highlight key data points quickly: Up to eight markers per channel Delta marker Marker zoom Peak search, peak all, markeranalysis functions and moreSynthesized source for network/impedanceanalysis provides: 1 mHz and 0.1 dB resolution 2- to 801-point sweep High-stability frequency reference(Option 4395A-1D5)Optional impedance analysis: Option 4395A-010 adds impedancemeasurement function Agilent 43961A RF impedancetest kitAgilent IBASIC adds these capabilities: Test automation External instrument controlthrough GPIB or digital I/O port Programming from an externalkeyboard Keystroke recording Customizing test setups foradjacent channel power andoccupied bandwidth measurements Data analysis IBASIC program one keyexecution function

Introducing the Agilent 4396BAn integrated solution deliveringexceptional performance andhigh value to 1.8 GHzColor TFT (thin film transistor) LCD withdual display Split-screen viewing for twoindependent channels VGA output for external monitorTwo independent channels provideflexibility Test parameters in either vectornetwork, spectrum, or optionalimpedance Get real-time data through fastalternate sweepsMarkers highlight key data points quickly: Up to eight markers per channel Delta marker Marker zoom Peak search, peak all, and moreThree analyzerfunctions give youmaximum flexibility.Select the type ofmeasurement withthe push of a button.Powerful calibration/compensationFast sweep increasesthroughputVector network andhigh sensitive spectruminput ports offer: R, A, B portsfor transmissionand reflectionmeasurements Spectrummonitoringon any network port1.44 MB floppy disk drivelets you save and recall ineither LIF or MS-DOS format: Test setups Calibration data Measurement data IBASIC programs Graphic (TIFF) filesTest sets and accessories give youmeasurement options in 50 Ω or 75 Ω: Agilent 85046A/B S parametertest setSpectrum analysis input port High Sensitivity 75 Ω impedance conversion(Option 4396B-1D7)Synthesized source for network/impedanceanalysis provides: 1 mHz and 0.1 dB resolution 2- to 801-point sweep High-stability frequency reference(Option 4396B-1D5)IBASIC adds these capabilities: Test automation External instrument controlthrough GPIB or digital I/O port Programming from an externalkeyboard Keystroke recording Customizing test setups foradjacent channel power andoccupied bandwidth measurements Data analysisOptional impedance analysis: Option 4396B-010 adds impedancemeasurement function Agilent 43961A RF impedancetest kit3

Exceptional Performance for Design and ManufacturingIn the lab, evaluate your designscompletely and accurately with oneinstrument. The Agilent 4395A andthe Agilent 4396B reduce learningand testing time so you get precisionmeasurements with improvedefficiency.On the production line, increase yourthroughput with the combinationanalyzer. A combination analyzermakes it faster and easier to switchbetween different types of tests.You can optimize production testingwith these capabilities: High test speed for vector networkanalysis Fast narrow-band spectrumanalysis with stepped FFT List sweep Limit lines Test automation with built-in IBASICThe analyzer’s small footprintsaves valuable bench space in anyenvironment.The Agilent combination analyzersfamily, a full-capability combinationanalyzer, makes no trade-offs amongvector network, spectrum, and impedance performance. The spectrumanalyzer function is based on digitalsignal processing (DSP) technology tospeed measurement computation. Itis a breakthrough in test instruments,giving you outstanding performanceat an attractive price.1. With IBASIC2. With Option 439xx-010 and Agilent 43961A4Make all of the following measurements with the Agilent 4395A/96B:Vector networkanalysisSpectrum analysisImpedance analysis2AttenuationAdjacent channel power1Impedance ( Z )BandwidthCarrier-to-noiseAdmittance ( Y )Center frequencyFlatnessPhase (θ)Complex impedanceFrequencyResistance (R)Cross talk/isolationHarmonic distortionReactance (X)DirectivityIntermodulation distortionConductance (Γ)FlatnessLinearitySusceptance (B)Frequency responseNoiseCapacitance (C)Inductance (L)Gain/lossOccupied bandwidthGain compressionOn/off ratioDissipation factor (D)Group delayPhase noiseQuality factor (Q)Insertion lossPowerReflection coefficient (Γ)LinearitySensitivityPhaseSpuriousReflection coefficientSidebandsReturn lossRippleRolloffVSWROptional: Burst-signal analysis (Option 439xx-1D6)1

Major SpecificationsAgilent 4395ANetwork analyzer specificationSpectrum analyzer specificationImpedance analyzer specification2Frequency range10 Hz to 500 MHz1Frequency range10 Hz to 500 MHzFrequency range100 kHz to 500 MHzFrequency resolution1 mHzNoise sidebands –104 dBc/Hztypical at 10 kHzoffsetMeas. parameter Z , θz, R, X, Y ,θy, G, B, Cs, Cp, Ls,Lp, Rp, Rs, X, D, Q,IΓI, Γx ,ΓyOutput power range–50 to15 dBmResolution bandwidth1 Hz to 1 MHz in1-3-10 stepsZ accuracy 3% (typical,basic accuracy)Dynamic range115 dB @ 10 Hz IFBW Dynamic range 100 dB third-order Source levelfree dynamic range–56 dBm to 9 dBm (at DUT)Dynamic accuracy 0.05 dB/0.3 deg.Level accuracy 0.8 dB @ 50 MHz 40 V (20 mA (max))CalibrationFull two-portSensitivity–145 dBm/Hz@ freq. 10 MHzDC bias(Option 4395A-001DC source or externalDC source is required.)CompensationOPEN/SHORT/LOADport extensionStandard features: Instrument BASIC, GPIB port, 3.5" floppy disk drive, direct print, RAM disk, VGA monitor output.Optional features: Impedance measurement (Option 4395A-010), time-gated spectrum analysis (Option 4395A-1D6), high-stability frequencyreference (Option 4395A-1D5), 50 Ω to 75 Ω spectrum input impedance conversion (Option 4395A-1D7), DC source( 40 V, 100 mA (ALC)) (Option 4395A-001).1. 100 kHz to 500 MHz if using the Agilent 87511A/B S-parameter test set.2. With Option 4395A-010 and the Agilent 43961A RF impedance test kitAgilent 4396BNetwork analyzer specificationSpectrum analyzer specificationImpedance analyzer specification2Frequency range100 kHz to 1.8 GHz1Frequency range2 Hz to 1.8 GHzFrequency range100 kHz to 1.8 GHzFrequency resolution1 mHzNoise sidebands –113 dBc/Hztypical at 10 kHzoffsetMeas. parameter Z , θz, R, X, Y ,θy, G, B, Cs, Cp,Ls, Lp, Rp, Rs, X,D, Q, IΓ I, Γx,ΓyOutput power range–60 to 20 dBmResolution bandwidth1 Hz to 3 MHz in1-3-10 stepsMeas. range2 Ω to 5 kΩDynamic range 120 dB @ 10 HzIFBWDynamic range 100 dB third-order Z accuracydynamic range 3% (typical,basic accuracy)Dynamic accuracyCalibration 0.05 dB/0.3 deg.Full two-portOverall level accuracySensitivity 1.0 dB –147 dBm/Hz@ freq. 1 GHz–66 dBm to 14 dBm (at DUT) 40 V (20 mA (max))Source levelDC bias(External DC biassource is required.)CompensationOPEN/SHORT/LOADport extensionStandard features: Instrument BASIC, GPIB port, 3.5" floppy disk drive, direct print, RAM disk, VGA monitor output.Optional features: Impedance measurement (Option 4396B-010), time-gated spectrum analysis (Option 4396B-1D6), high-stability frequencyreference (Option 4396B-1D5), 50 Ω to 75 Ω spectrum input impedance conversion (Option 4396B-1D7).1. 300 kHz to 1.8 GHz if using the Agilent 85046A/B S-parameter test set.2. With Option 4396B-010 and the Agilent 43961A RF impedance test kit.5

Component Analysis for Today and the FutureModern digital communicationsystems require high linearity ofsignal transmission. To meet thisnew requirement, electronic components must have well-characterizedphase and magnitude performance.Spectrum measurements, such asintermodulation distortion, are keyto achieving high system quality.Also impedance measurements arevery important to develop the highquality design.The Agilent 4395A/96B keeps up withyour new demands by offering thecapabilities you need in an easy-to-useinstrument. Eliminate the extra workand cost associated with using multipleinstruments. Follow these simple stepsto test your components: Easily alternate between vector network and spectrum measurements. See two measurement parameterson the dual-display color TFT LCD. Use powerful marker functions andup to eight markers per channelfor data searching. Save and recall calibration data,measurement data, and testprograms with either internalRAM disk or floppy disk. Easily dump data directly from theanalyzer to the centronics printer.6AmplifiersMixersMake both linear and non-linearmeasurements with the Agilentcombination analyzer. You get widedynamic range for accurate intermodulation distortion measurement.Measure mixer output easily withpeak all and market list. Measureconversion signals for distortionand harmonics.OscillatorsPredict oscillator stability by measuringthe reflection coefficient in the vectornetwork mode. Turn to the spectrummode to see oscillation frequency,harmonics, and noise. Use markerzoom for measuring output level.

FiltersCharacterize passband, stopband, groupdelay, and phase: Wide dynamic range. 0.05 dB/ 0.3 deg. gain/phasedynamic accuracy. Real-time tuning. High-stability frequency reference(Option 439xx-1D5) for narrowband and high Q devices.Agilent 4396B network/spectrumsimultaneous measurementTwo independent channelsWith the Agilent 4395A, you determinethe analyzer type (network, spectrum,or impedance) first, and then you candefine each channel’s parameters underyour selected analyzer type. Using the4396B, you can define analyzer typefor each channel independently. So ifyou see any unusual frequency responsewhile making a network measurementon the Agilent 4396B, you can quicklyswitch to spectrum monitoring (sourcewill be turned off) to identify spurioussignals without changing DUT connection on the color LCD with dualdisplay as shown in figure.7

Precision Spectrum Analysis with Improved Speed and AccuracyAccurate signal monitoring is criticalfor designing quality products. Intoday’s competitive environment, youneed better spectrum measurementcapabilities to stay ahead of thecompetition. The Agilent 4395A/96B,designed with new digital techniques,outperforms traditional analogspectrum analyzers. Improve testing speed up to 100times for narrow RBW sweep. Theanalyzer’s stepped FFT technique(4395A: all RBWs, 4396B: RBW 3 kHz) breaks the speed barrierto give you lower noise floorwithout sacrificing speed. Fully synthesized source. 1 Hz RBW with 3:1 shape factorfor close-in signals.List sweep function can be used in notonly network and impedance analysis,but also in spectrum analysis. Listsweep separates the sweep frequencyrange into segments, and each segmentcan have an independent frequencyrange, number of sweep points, RBW,and power level settings. By using listsweep function, separate frequencybands can be measured in one sweep,or different RBW can be set for harmonics, IMD, and wide dynamic range measurements can be done in a shorter time. See close-in signals using the1 Hz RBW with a 3:1 shape factor.Monitor close-in low level signals suchas the 60-Hz power line sidebandripple shown here. You get excellentspectral resolution from digital RBWfilters (4395A: all RBWs, 4396B:RBW 3 kHz) with a shape factoras steep as 3:1.IMD measurement using list sweep functionSweep time comparison at100 kHz span and 100 Hz RBWAnalog RBW SA30 sAgilent 4396B with stepped FFT1.2 sAgilent 4395A with stepped FFT0.3 sGet dramatic speed improvement, with noloss of accuracy, for narrow RBW sweeps.In addition, low phase noise provides improvedsignal resolution.8Measure noise precisely. The analyzer’s lownoise floor provides the sensitivity required fordetecting low-level signals.

Perform accurate burst signal analysiswith time-gating (Option 439xx-1D6).Digital video bandwidth smoothsnoise faster than analog spectrumanalyzers.Use these powerful spectrum analysiscapabilities, combined with vectornetwork analysis, for design and testin these applications: CATVGPSGSMHDTVVSATVCROptical disk drivesMobile radioCellular communicationsFrequency spectrum of a signalmeasured without time gating.Time gating (Option 439xx-1D6) lets you makemeasurements within the burst envelope.You can use time gating to accuratelycharacterize burst-modulated signalsused in data storage, television, andvideo equipment. Narrow gating(4395A: 6 ms min. 4396B: 2 ms min.)is ideal for testing disk drives.View the amplitude and modulationcharacteristics of a repetitive signal in ZeroSpan. The analyzer functions as a tunablereceiver.9

Accurate Direct Impedance MeasurementThe Agilent 4395A/96B can performdirect impedance measurements withthe addition of Option 439xx-010 andthe Agilent 43961A RF impedancetest kit. Covering from 100 kHz,impedance parameters Z , θ, C, L,Q, D and more are measured anddisplayed directly on the color TFTLCD display. For the Agilent 4395A,the Option 4395A-001 DC source isavailable to apply to the device, upto 40 V maximum.Agilent 4395A/96BRRF outBARAAgilent 43961AOutputN-N cableRF inTest fixtureDC sourceinputConnecting the Agilent 43961A to the Agilent 4395A/96BDirect display of impedance dataTwo independentmeasurementchannels andflexibility toimpedanceanalysisThe impedance measurementcapability provides powerful displaychoices, allowing direct parameterversus frequency display. Measureand display capacitance, inductance,and impedance magnitude and phase,and more, as functions of frequency.In addition, a lumped equivalentcircuit function aids componentmodeling and simulation.Many applicable fixtures andpowerful error compensationEquivalent component analysis(resonator)10Many 7-mm connector type testfixtures can be used for theAgilent combination analyzer withOption 439xx-010 and the 43961Aimpedance test kit because the43961A employs the 7-mm connectoras the measurement port. So, you canselect an appropriate fixture amongthem. The combination analyzer withOption 439xx-010 has the powerfulOPEN/SHORT/LOAD compensation,and port extension compensation,which eliminate any errors introducedby the test fixture and allow accuratedirect impedance measurements.

Easy Test Automation and System IntegrationMaximize your throughput with theAgilent combination analyzer family.The analyzer is designed for highvolume testing:Limit functionsThe built-in limit lines allow you toscreen parts automatically and quickly. Fast vector network measurementspeed List sweep for fast testing atselected frequencies Built-in IBASIC for test automation. Limit lines for pass/fail test RAM disk with fast data access Digital I/O port for controllinghandlers or non-GPIB testequipment VGA monitor output for an evenlarger display, improving productivity and reducing viewing fatigueWhat is IBASIC?IBASIC is a subset of the HT BASICprogramming language. It is includedin the standard Agilent 4395A/96B.IBASIC is extremely powerful, yeteasy to use. You can automate testing,make customized programs, performdata analysis, and control externalequipment with IBASIC. It supports anexternal keyboard for your convenience,and for effortless programming, itprovides keystroke recording, whichlogs test code sequences as you pushthe buttons on the front panel.You can control additional equipmentwithout an external computer. Byadding some external signal sourcesand RF switches, you can construct acost-effective, high-speed test systemfor production.The 4396B system (example shownin the block diagram) provides highthroughput, automated testing ofgain, phase, and intermodulationdistortion for components.Integrate different instruments into a test system example with the Agilent 4396BIBASIC program one key execution(Agilent 4395A only)The Agilent 4395A has a unique onekey execution function. It allows youto select your desired IBASIC programin RAM disk or floppy disk, and torun it by simply pressing the softkey.It’s beneficial to undertake your firstfunction in the Agilent 4395A.11

Ordering InformationAgilent 4395ANetwork/spectrum/impedanceanalyzerFurnished accessoryPower cable and CD-ROM (manual)Note: Test fixtures, a keyboard, and aprinted manual are not furnished asstandard.Configuration guideChoose the option from the groups A , B , and C depending on yourrequirement. Then, choose the appropriate options from the option groups D , E , F , and G . Choose ONE and ONLY one(Options are mutually exclusive) Choose any combination A For DC bias source 4395A-700 no DC bias source 4395A-001 DC bias sourceAgilent 4396BNetwork/spectrum/impedanceanalyzer E For accessories 4395A-1D7 50 Ω - 75 Ω minimumloss pad 4395A-810 keyboard 4395A-1CM rackmount kit 4395A-1CN front handle kit 4395A-1CP handle/rack mount kitFurnished accessoryPower cable and CD-ROM (manual)Note: Test fixtures, a keyboard, and aprinted manual are not furnished asstandard. F For calibration certificate 4395A-1A7 ISO 17025 compliantcalibrationChoose the option from the groups A and B depending on yourrequirement. Then, choose the appropriate options from the option groups C , D , E , and F . G For manual1 4395A-ABA U.S. - Englishlocalization 4395A-ABJ Japan - Japaneselocalization 4395A-ABF France – Frenchlocalization 4395A-0BW Service documentation,assembly level B For frequency reference function 4395A-800 standard frequencyreference 4395A-1D5 high stability frequencyreference4395A D For impedance measurement function 4395A-010 impedance measurementfunction A For frequency reference function 4396B-800 standard frequencyreference 4396B-1D5 high stability frequencyreference C For impedance measurement function 4396B-010 impedance measurementfunction D For accessories 4396B-1D7 50 Ω - 75 Ω minimumloss pad 4396B-810 keyboard 4396B-1CM rackmount kit 4396B-1CN front handle kit 4396B-1CP handle/rack mount kit4396B12 Choose ONE and ONLY one(Options are mutually exclusive) Choose any combination B For time-gated spectrum analysis 4396B-706 no time-gated spectrumanalysis 4396B-1D6 time-gated spectrumanalysis C For time-gated spectrum analysis 4395A-706 no time-gated spectrumanalysis 4395A-1D6 time-gated spectrumanalysis1. Printed manual is not furnished as standard.Configuration guide E For calibration certificate 4396B-1A7 ISO 17025 compliantcalibration F For manual1 4396B-ABA U.S. - Englishlocalization 4396B-ABJ Japan - Japaneselocalization 4396B-0BW service documentation,assembly level

Test sets, splitters,and directional bridgesS-parameter test sets allow both forward and reverse measurements witha single connection of your DUT.Transmission/reflection (T/R) test kitsallow measurements in one directiononly. Includes test set, short, load, andDUT return cable.Agilent 85046A50 Ω, 7-mm50 Ω, type-N50 Ω, 3.5-mm75 Ω, type-N5. Accessory kitsAgilent 87511B – 75 Ω S-parameter(100 kHz to 500 MHz), type-N test portAgilent 85046B – 75 Ω S-parameter(300 kHz to 2 GHz), type-N test portA complete line of kits make calibrating your analyzer fast and easy.Agilent 85031BAgilent 85032BAgilent 85033DAgilent 85036BAgilent 87511A – 50 Ω S-parameter(100 kHz to 500 MHz), 7-mm test port(Option 87511A-800) or type-N testport (Option 87511A-001)Agilent 85046A – 50 Ω S-parameter(300 kHz to 3 GHz), 7-mm test port14. Calibration kitsThese kits furnish RF componentsgenerally required for use with testsets and splitters.Agilent 87512AAgilent 87512A 50 Ω (dc-2 GHz)type-N connectorsAgilent 87512B 75 Ω (dc-2 GHz)type-N connectorsAgilent 11853A 50 Ω, type-N shortcircuits and adaptersAgilent 11854A 50 Ω, type-N toBNC adaptersAgilent 11855A 75 Ω, type-Nterminations and adaptersThese type-N power splitters allowtransmission measurements only ina single direction.Agilent 11856A 75 Ω, type-N toBNC adaptersAgilent 11850C 50 Ω 3-way powersplitter (dc-3 GHz)6. Cable kitsAgilent 11850D 75 Ω 3-way powersplitter (dc-2 GHz)Agilent 11667A 50 Ω 2-way powersplitter (dc-18 GHz)These high-directivity RF bridgesare designed for accurate reflectionmeasurements and signal-levelingapplications.For reliable connections between thetest set and the DUT.Agilent 11851B 50 Ω type-N RF cable kit(for type-N splitters or T/R test sets)Agilent 11857B 75 Ω type-N test portreturn cablesAgilent 11857D 50 Ω 7-mm test portreturn cablesAgilent 86205A 50 Ω RF bridge(300 kHz to 6 GHz)Agilent 86207A 75 Ω RF bridge(300 kHz to 3 GHz)1. To convert test port to type-N, use Agilent11524A 7-mm to type-N(f) adapter.13

7. Probes8. Impedance test kitExtend the capabilities of the analyzerdirectly to your circuit.The Agilent 4395A/96B can performdirect impedance measurements withthe addition of Option 439xx-010 andthe Agilent 43961A RF impedance testkit. The Agilent 43961A includes atest adapter, an N(m)-N(m) cable,OPEN/SHORT/LOAD calibrationstandard, and carrying case.Agilent 41800A 5 Hz to 500 MHz activeprobeAgilent 41802A 5 Hz to 100 MHz1 MΩ input adapterAgilent 54701A 2.5 GHz high-impedanceprobe (requires Agilent 1743A probeoffset and power control module)16197A bottom electrode SMD testfixture (DC to 3 GHz)16092A spring clip test fixture(DC to 500 MHz)16093A Binding post test fixture(DC to 250 MHz)16093B Binding post test fixture(DC to 125 MHz)Agilent 85024A 300 MHz to 3 GHzhigh frequency probeTest fixtures and DUT sizesAgilent 1141A dc to 200 MHzdifferential probeAgilent 43961A RF impedance test kitAgilent 11940A 9 kHz to 30 MHzclose-field probe set9. Test fixtures for impedancemeasurementAgilent 11941A 30 MHz to 1 GHzclose-field probe set16191A bottom electrodeSMD test fixture (DC to 2 GHz)Agilent 11945A 9 kHz to 1 GHzclose-field probe set16192A parallel electrodeSMD test fixture (DC to 2 GHz)16194A high temperature componenttest fixture (DC to 2 GHz)16196A 1608 (mm)/0603 (inch) parallelelectrode SMD test fixture(DC to 3 GHz)16196B 1005 (mm)/0402 (inch) parallelelectrode SMD test fixture(DC to 3 GHz)16196C 0603 (mm)/0201 (inch) parallelelectrode SMD test fixture(DC to 3 GHz)14

General CharacteristicsAgilent 4395ARemote programming interface: GPIBinterface operates according to IEEE488.1-1987 and IEEE 488.2-1987 andIEC 625 standards.I/O port: 8 bit I/O, 24 bit I/OPrinter: Centronics parallel I/O port(Agilent PCL3)Temperature: Operatingl, 0 C to 40 C;storage, –20 C to 60 CHumidity: Operating1 15% RH 95%Power: 100/120/220/240 V 10%,47 Hz to 63 Hz, 300 VA max.Connectors: 50 Ω type-N(f)Probe power: 15 V @ 300 mA, –12.6 V@ 160 mA, GNDDisplay: 8.4 inch color TFT LCDWeight: 21 kg (46 lb.) typicalDimensions:235 mm H x 425 mm W x 553 mm D(9.25 in. x 16.75 in. x 21.72 in.)Agilent 4396BRemote programming interface: GPIBinterface operates according to IEEE488.1-1987 and IEEE 488.2-1987 andIEC 625 standards.I/O port: 8 bit I/OPrinter: Centronics parallel I/O port(Agilent PCL3)Temperature: Operating 1, 0 C to 40 C;storage, –20 C to 60 CHumidity: Operating1 15% RH 95%Power: 100/120/220/240 V 10%,47 Hz to 63 Hz, 300 VA max.Connectors: 50 Ω type-N(f)Probe power: 15 V @ 300 mA, –12.6 V@ 160 mA, GND.Display: 8.4 inch color TFT LCDWeight: 21.5 kg (47 lb.) typicalDimensions:235 mm H x 425 mm W x 553 mm D(9.25 in. x 16.75 in. x 21.72 in.)1. Disk drive operating region: 10 C to 40 C and15% to 80% RH.Agilent 4395A accessories selection guide1. 100 kHz to 500 MHz2. 7-mm test port (Option 87511A-800) or type-N test port (Option 87511A-001)3. 300 kHz to 3 GHz 7-mm test port. To convert to type-N, use Agilent 11524A 7-mm to type-N (f) adapter4. 300 kHz to 4 GHzAgilent 4396B accessories selection guide1. 7-mm test port. To convert to type-N, use Agilent 11524A 7-mm to type-N (f) adapterAdditional literatureFor detailed specifications, refer tothe Agilent 4395A Data Sheet(literature number 5965-9340E), orAgilent 4396B Data Sheet(literature number 5965-6311E).MS-DOS is a registered trademark of MicrosoftCorporation.15

Agilent Technologies’ Test and Measurement Support,Services, and AssistanceAgilent Technologies aims to maximize the value youreceive, while minimizing your risk and problems. Westrive to ensure that you get the test and measurementcapabilities you paid for and obtain the support you need.Our extensive support resources and services can helpyou choose the right Agilent products for your applicationsand apply them successfully. Every instrument and systemwe sell has a global warranty. Support is available for atleast five years beyond the production life of the product.Two concepts underlie Agilent’s overall support policy:“Our Promise” and “Your Advantage.”Our PromiseOur Promise means your Agilent test and measurementequipment will meet its advertised performance andfunctionality. When you are choosing new equipment, wewill help you with product information, including realisticperformance specifications and practical recommendationsfrom experienced test engineers. When you use Agilentequipment, we can verify that it works properly, helpwith product operation, and provide basic measurementassistance for the use of specified capabilities, at no extracost upon request. Many self-help tools are available.Agilent 4395A rear panelYour AdvantageYour Advantage means that Agilent offers a wide rangeof additional expert test and measurement services,which you can purchase according to your unique technicaland business needs. Solve problems efficiently and gain acompetitive edge by contracting with us for calibration,extra-cost upgrades, out-of-warranty repairs, and onsiteeducation and training, as well as design, system integration,project management, and other professional engineeringservices. Experienced Agilent engineers and techniciansworldwide can help you maximize your productivity, optimizethe return on investment of your Agilent instruments andsystems, and obtain dependable measurement accuracyfor the life of those products.Agilent T&M Software and ConnectivityAgilent’s Test and Measurement software and connectivityproducts, solutions and developer network allows you totake time out of connecting your instruments to yourcomputer with tools based on PC standards, so you canfocus on your tasks, not on your connections. Visitwww.agilent.com/find/connectivityfor more information.Agilent 4396B rear panelBy internet, phone, or fax, get assistance with all yourtest & measurement needsAgilent Email Updateswww.agilent.com/find/emailupdatesGet the latest information on the productsand applications you select.Phone or FaxUnited States:(tel) 800 829 4444Canada:(tel) 877 894 4414(fax) 905 282 6495China:(tel) 800 810 0189(fax) 800 820 2816Europe:(tel) (31 20) 547 2323(fax) (31 20) 547 2390Japan:(tel) (81) 426 56 7832(fax) (81) 426 56 7840Korea:(tel) (82 2) 2004 5004(fax) (82 2) 2004 5115Latin America:(tel) (305) 269 7500(fax) (305) 269 7599Taiwan:(tel) 0800 047 866(fax) 0800 286 331Other Asia Pacific Countries:(tel) (65) 6375 8100(fax) (65) 6836 0252Email:tm asia@agilent.comOnline Assistance:www.agilent.com/find/assistProduct specifications and descriptions in this documentsubject to change without notice. Agilent Technologies, Inc. 2000, 2003, 2004Printed in USA, April 2, 20045965-9374E

a spectrum analyzer, and an optional impedance analyzer. Take an innovative approach to evaluating electronic components and circuits. The Agilent Technologies combination analyzers family combines three analyzer functions in one powerful instrument: a vector network analyzer, a spectrum analyzer

Related Documents:

Agilent 1290 Infinity Agilent G1888A X X Agilent 7673A Agilent 7683A Agilent HS7694 X X Agilent 7695A X Agilent 79855(A) X Agilent 5880 Agilent 5890 Agilent 6850 (27 Pos. Einlegeschale) . Autosampler-Kompatibilitätstabelle 2. H eadline as disp

Agilent 1290 Infinity X Agilent G1888A Agilent 7673A X Agilent 7683A X Agilent HS7694 Agilent 7695A Agilent 79855(A) X Agilent 5880 X Agilent 5890 X . Autosampler Compatibility Chart Crimp Neck ND8 1 1. Snap Ring ND11 Screw Neck ND13 Shell Vials Shell Vials Shell Vials Shell Vials Headspa

Agilent 1290 Infinity X X Agilent G1888A Agilent 7673A X X X Agilent 7683A X X X X Agilent HS7694 Agilent 7695A Agilent 79855(A) X X Agilent 5880 X X Agilent 5890 X X . Autosampler Compatibility Chart 2. H eadline as disp

erful instrument: a vector network analyzer, a spectrum analyzer, and an optional impedance analyzer. Now you can use one analyzer for multiple testing needs. Because many electronic components such as amplifiers require both vector network and spectrum parameters, you need a combination an

Tip 1: How to use Agilent 82357B USB/GPIB converter in NI’s MAX or LabVIEW? Figure 2. Typical setup for Agilent IO Libraries Suite. 1 Agilent I/O Libraries Each Agilent IO product is bundled with the Agilent I/O libraries. There are four I/O libraries included in Agilent IO libraries Suite: Agilent

Digital Multi Meter No Substitute Agilent 3458A, Agilent 34401A, Agilent 34410A and Agilent 34411A 1 Dynamic Accuracy Test Kit No Substitute Agilent Z5623A Opt H01 1 Power Sensor No Substitute Agilent E9304A with Opt H18 Agilent 8482A 1 1 Calibration Kit No Substitute Agilent 85032F 1 Fixed

Agilent 7890 GC Agilent 8860 GC Agilent 8890 GC Agilent Intuvo 9000 GC Agilent 5977 Series MSD Agilent 7000 Series GC/TQ OpenLab Note: The My Order portal, along with your Agilent field service engineer, may have specific site preparation information for your configuration. Train y

ACCOUNTING 0452/22 Paper 2 October/November 2018 1 hour 45 minutes Candidates answer on the Question Paper. No Additional Materials are required. READ THESE INSTRUCTIONS FIRST Write your Centre number, candidate number and name on all the work you hand in. Write in dark blue or black pen. You may use an HB pencil for any diagrams or graphs. Do not use staples, paper clips, glue or correction .