ATEC Breast Biopsy And Excision System

2y ago
13 Views
2 Downloads
1.60 MB
20 Pages
Last View : 1d ago
Last Download : 2m ago
Upload by : Helen France
Transcription

ATEC Breast Biopsyand Excision System A Compassionate Solution for All Patients

Patient Focused, Physician InspiredATECVacuum-AssistedBreast Biopsy SystemFastSafeSimple Tissue acquisition occurs every4.5 seconds, typically lastingless than 30 seconds total.* F ully closed system reducescontamination risk. One user-friendly console forevery modality. Fully disposable device andtubing minimizes staff and patientexposure to biohazard. No software to program oroperate console. Easily delivers local anestheticwithout interruption. Combination of saline lavageand constant aspiration helpsensure a core with every cycle.*Data on file with Hologic. Multiple needle options fordiagnostic tissue sampling toaddress a wide spectrum ofpatients. Simple one minute set-upand clean-up.

I n t e r v e n t i o n a lB r e a s tS o l u t i o n s

Stereotactic-GuidedBreast BiopsyATEC on MultiCare Platinum stereotacticbreast biopsy guidance system Hologic’s ATEC breast biopsy devicecoupled with our best-in-class prone andupright stereotactic X-ray systems offerscustomers a quick, compassionate procedurewith accurate clinical results. We deliver a complete breast biopsy solutionfor use under stereotactic X-ray guidanceto our customers. To address a broad spectrumof patients, we offer a vacuum-assisted breastbiopsy system with a wide variety of needlechoices with integrated pain management,and our biopsy site markers provide accuratedelivery to the biopsy site. Using the completeHologic solution, total tissue acquisition timetypically lasts less than 30 seconds.*ATEC on Affirm breast biopsyguidance system ATEC on Selenia with Digital StereoLoc IIupright breast biopsy system *Data on file with Hologic.

STEREOTA C T I C - G U I D E DB REASTB I O P S YProne Stereotactic X-ray Breast Biopsy Guidance System CompatibilityHologic MultiCare Platinum stereotactic breast biopsy guidance system Hologic Devices0912-201212-200912-12*AdapterATEC STX-1ATEC STX-2Ancillary ProductsATEC NG09ATEC NG12ATEC RTFASiemens & Fischer MammoTestHologic Devices0909-201209-200909-12*AdapterATEC STX-FischerATEC STX-2FAncillary ProductsATEC NG09FATEC NG12FATEC RTFASiemens & Fischer MammoTest Lateral Arm ApproachHologic Devices0914-20AdapterATEC STX-2Ancillary ProductsATEC NG09FATEC RTFAUpright Stereotactic X-ray Breast Biopsy Guidance System CompatibilityGE Senographe DS and GE SenographeEssential Vertical Approach Hologic StereoLoc II breast biopsy guidance system Hologic Devices0912-201212-200912-12*AdapterATEC STX-2Ancillary ProductsATEC NG09ATEC NG12ATEC RTFAHologic Devices0912-201212-200912-12* AdapterAncillary ProductsATEC NG09FATEC NG12FATEC RTFAGE Senographe DS and GE SenographeEssential Lateral Arm Approach Hologic Affirm breast biopsy guidance system Hologic 0912-12*AdapterATEC STX-2Ancillary ProductsATEC NG09ATEC NG12ATEC RTFAAdapterATEC STX-2Ancillary ProductsATEC NG09FATEC RTFASiemens Opdima Instrumentarium Delta 32 Hologic Devices0914-20Hologic Devices0914-20 AdapterATEC STX-2Key to Ordering ATECStereotactic DevicesDevice TypeAncillary ProductsATEC NG09FATEC RTFAATEC 0912-20ATEC 09 12Hologic Devices0909-200912-201212-200912-12*AdapterATEC STX-2Aperture Size (mm) (core length)12: 12 mm aperture, 20: 20 mm apertureSuffix (if any)MR: MR dedicated handpieceAncillary ProductsATEC NG09FATEC RTFA* ATEC petite needle options designed for thin breasts work with aminimum compression of 22mm.Outer Cannula (incision size)Needle Gauge (g) 09: 9g, 12: 12gNeedle Length (cm)09: 9 cm long, 12: 12 cm long, 14: 14 cm longAncillary ProductsATEC NG09FATEC NG12FATEC RTFAGiotto Biopsy Digit (S, SL, AM Models)Hologic Devices0909-200912-200909-12*0912-12*20AdapterATEC STX-2Note: Availability may vary by country.

Stereotactic Breast BiopsySite MarkersHologic’s stereotactic X-ray biopsy site marking solutions provide physicians definition and distinction.Hologic provides a wide array of biopsy site marking options with a total of seven clearly distinct shapes.SecurMark for ATECTriMark for ATEC SecurMark biopsy site markers are comprised of: T riMark biopsy site markers are comprisedof bio-compatible permanent titanium. - A bio-absorbable suture-like netting,designed to minimize movement withinthe biopsy cavity, that surrounds abio-compatible permanent marker. T wo shapes available. F eatures a rigid side deploymentdelivery system.- Two titanium and three stainless steelshapes available. Features side deployment delivery systemwith a flexible cannula.Note: Product availability may vary by country.SecurMark stainless steel shape one under mammographySecurMark stainless steel shape two under mammographyNote: Secondary images are side viewsTitaniumStainless steelSecurMark Biopsy Site MarkersNote: Shapes appear larger than actual size.TriMark Biopsy Site Markers

S t e r e o t a c t ic - G U I D E DB REASTB I O P S YBiopsy Site Marker Compatibilityfor Stereotactic-Guided Breast BiopsyHologic Biopsy DevicesATEC 0909-20ATEC -36-09-ss1ATEC 0912-20ATEC 0912-1244444444444444Biopsy Site Marker OptionsSMark-ATEC-36-12ATEC 1209-204ATEC 1212-20ATEC 31244TriMarkTD-2S-131244

Ultrasound-GuidedBreast BiopsyHologic’s breast biopsy solutions continue to lead the way in offeringphysicians a clinically effective and more compassionate alternative toopen surgical biopsy.The ATEC vacuum-assisted breast biopsy system hasThe ATEC system provides the option for additionalbeen designed for radiologists and surgeons who findpatient compassion with FDA clearance for partialcompassionate patient care, confident clinical results, andand complete removal of benign breast tissue. economic value essential elements in minimally-invasivebreast biopsy.ATEC with the Aixplorer Ultrasound system

ULTRASOUN D - G U I D E DAperture open under ultrasound guidanceand ready for tissue acquisitionAll Ultrasound SystemsHologic Devices1212-201209-200912-200909-20Ancillary ProductsATEC RTFANote: Availability may vary by countryKey to Ordering ATECUltrasound DevicesDevice TypeOuter Cannula (incision size)Needle Gauge (g) 09: 9g, 12: 12gNeedle Length (cm)09: 9 cm long, 12: 12 cm long, 14: 14 cm longAperture Size (mm) (core length)12: 12 mm aperture, 20: 20 mm apertureSuffix (if any)MR: MR dedicated handpieceATEC 1212-20ATEC 12 1220B REASTB I O P S Y

Ultrasound Breast BiopsySite MarkersHologic’s biopsy site marking solutions for use under ultrasound guidance provide physicians thevisual assurance they deserve.Hologic provides a wide array of biopsy site marking options with a total of seven clearly distinct shapes.SecurMark for ATECTriMark for ATEC SecurMark biopsy site markers are comprised of: TriMark biopsy site markers are comprisedof bio-compatible permanent titanium. - Ultrasound visible bio-absorbable suture-likenetting, designed to minimize movementwithin the biopsy cavity that surrounds abio-compatible permanent marker. Two shapes available. Features a rigid side deploymentdelivery system.- Two titanium and three stainless steelshapes available. Features side deployment delivery system witha flexible cannula.Note: Product availability may vary by country.SecurMark under UltrasoundTitaniumStainless steelSecurMark Biopsy Site MarkersNote: Shapes appear larger than actual size.TriMark Biopsy Site Markers

ULTRASOUN D - G U I D E DB REASTB I O P S YBiopsy Site Marker Compatibilityfor Ultrasound-Guided Breast BiopsyHologic Biopsy DevicesBiopsy Site Marker OptionsATEC 0909-20ATEC 1209-20ATEC k-A-13-09-ss144SMark-A-13-09-ss244ATEC 1244No Lines. No Waiting.Hologic iStore is Now Open!Providing you a fast andeasy way to order ATEC ,Eviva and Celero breastbiopsy devices, biopsydrapes, and MammoPad supplies online.To learn more, please contact http://signup.hologic.com

Hologic offers two Introducer LocalizationSets (ILS), exclusively for use with ourMRI devices, that aid in the targeting andMRI-GuidedBreast Biopsybiopsy process.Hologic’s SureSight obturator simplifies targeting under MRI guidance allowingfor the ability to easily identify your areaHologic, the pioneer in MRI breast biopsy, hasmore than 900 facilities worldwide performing MRIbreast biopsy with the ATEC device, and is themarket leader in breast MRI biopsy procedures.With Hologic, physicians have reduced thetypical procedure time to under 40 minutes,greatly improving patient comfort and optimizingcostly magnet time. The teaming of Hologicand Sentinelle now allows physicians animproved solution in early breast cancerdetection and accurate intervention.of interest by providing outstanding visualconfirmation.1ATEC MRI Biopsy Device withSentinelle MRI CoilATEC MRI is not only Fast, Safe and Simple, but also: Clinically proven accurate under MRI guidance .1 Supports both Grid and Pillar/Post Targeting Methods. 3T magnet compatible. MRI access needle allows for the ability to treat thin breasted women.Standard obturator under MRI GuidanceSureSight obturator under MRI Guidance NOTE: Availability may vary by country.1S chrading S, Simon B, Braun M, Wardelmann E, Schild H, Kuhl C. MRI-Guided BreastBiopsy: Influence of Choice of Vacuum Biopsy System on the Mode of Biopsy of MRIOnly Suspicious Breast Lesions. AJR 2010; 194: 1650-1657.

M R I - G U I D E DB REASTMRI System CompatibilitySentinelle Breast MRI CoilHologic Devices0914-20MR0914-12MRAncillary ProductsILS 0914-20ILS 0914-20OBILS 0914-12ILS 0914-12OBATEC RTFAAurora MRI SystemHologic Devices0914-20MR0914-12MRAncillary ProductsATEC NG09A1ATEC NG09A2ILS 0914-20ILS 0914-20OBILS 0914-12ILS 0914-12OBATEC RTFAConfirma Access 4-Channel Breast Coil Hologic Devices0914-20MR0914-12MRAncillary ProductsILS 0914-20ILS 0914-20OBILS 0914-12ILS 0914-12OBATEC RTFAInvivo 4-Channel Open Breast Array Coil (OBC)Hologic Devices0914-20MR0914-12MRAncillary ProductsILS 0914-20ILS 0914-20OBILS 0914-12ILS 0914-12OBATEC RTFAInvivo 7-Channel Breast Biopsy Array Coil (BBC)Hologic Devices0914-20MR0914-12MRAncillary ProductsILS 0914-20ILS 0914-20OBILS 0914-12ILS 0914-12OBATEC RTFAKey to Ordering ATECMRI DevicesDevice TypeOuter Cannula (incision size)Needle Gauge (g) 09: 9g, 12: 12gNeedle Length (cm)09: 9 cm long, 12: 12 cm long, 14: 14 cm longAperture Size (mm) (core length)12: 12 mm aperture, 20: 20 mm apertureSuffix (if any)MR: MR dedicated handpieceInvivo 7-Channel Luminescence Breast CoilHologic Devices0914-20MR0914-12MRAncillary ProductsILS 0914-20ILS 0914-20OBILS 0914-12ILS 0914-12OBATEC RTFANoras 4-Channel Open Breast Array Coil (OBC)Hologic Devices0914-20MR0914-12MRAncillary ProductsILS 0914-20ILS 0914-20OBILS 0914-12ILS 0914-12OBATEC RTFAUSAI Liberty 5000 4-Channel Breast CoilHologic Devices0914-20MR0914-12MRAncillary ProductsILS 0914-20ILS 0914-20OBILS 0914-12ILS 0914-12OBATEC RTFAUSAI Liberty 9000 4-Channel Breast CoilHologic Devices0914-20MR0914-12MRAncillary ProductsILS 0914-20ILS 0914-20OBILS 0914-12ILS 0914-12OBATEC RTFAUSAI Liberty 9000 8-Channel Breast CoilHologic Devices0914-20MR0914-12MRATEC 0914-20MRATEC 09 14 20Ancillary ProductsILS 0914-20ILS 0914-20OBILS 0914-12ILS 0914-12OBATEC RTFAMRB I O P S Y

MRI Biopsy Site MarkersHologic’s MRI biopsy site marking solutions provide physicians the visualization they need.Hologic understands physician needs may vary. That is why we offer both titanium and stainless steel MRIbiopsy site marker options, to provide optimal MRI artifact for all.SecurMark for ATECTriMark for ATEC SecurMark biopsy site markers are comprised of: TriMark biopsy site markers are comprisedof bio-compatible permanent titanium. - A bio-absorbable suture-like netting,designed to minimize movement withinthe biopsy cavity that surrounds abio-compatible permanent marker. Two shapes available. Features a rigid-end-deploy delivery device foran integrated MRI solution.- Two titanium and three stainless steelshapes available.- Stainless steel options offer increasedMRI artifact. Features a rigid-end-deploy device for an integratedMRI solution.Note: Product availability may vary by country.TitaniumStainless steelSecurMark Biopsy Site MarkersNote: Shapes appear larger than reality.TriMark Biopsy Site Markers

M R I - G U I D E DB REASTB I O P S YBiopsy Site Marker Compatibilityfor MRI-Guided Breast BiopsySecurMark Stainless Steelunder MRITriMark Titaniumunder MRIBiopsy Site Marker OptionsHologic Biopsy DevicesATEC 0914-20MRATEC iMarkTD-13MR44TriMarkTD-2S-13MR44Note: Availability may vary by country.

Emerging Imaging Technologiesand the ATEC Breast Biopsy DeviceHologic created a solution for high-risk patients with the development ofATEC MRI breast biopsy for use under MRI guidance, and now continues theirinnovation through compatibility with other emerging imaging technologies. Hologic partnered with Naviscan in 2008 to perform the first breast biopsy procedures utilizingATEC and the Stereo Navigator.Naviscan Stereo Navigator Hologic Devices0914-20MRAncillary ProductsILS 0914-20ATEC RTFANote: Availability may vary by country.

E M ER G I N GHologic partnered with Dilon in 2009 to perform the first breast biopsyprocedures utilizing ATEC and the Gammaloc System.Dilon 6800 Gamma Camera with Dilon GammoLoc System Hologic Devices0914-20MR Ancillary ProductsILS 0914-20ATEC RTFANote: Availability may vary by country.Key to OrderingATEC DevicesDevice TypeOuter Cannula (incision size)Needle Gauge (g) 09: 9g, 12: 12gNeedle Length (cm)09: 9 cm long, 12: 12 cm long, 14: 14 cm longAperture Size (mm) (core length)12: 12 mm aperture, 20: 20 mm apertureSuffix (if any)MR: MR dedicated handpieceATEC 0914-20MRATEC 09 14 20MRTE C H NOLO G I ES

Redefining Industry StandardsVision. Innovation. Results.Hologic is dedicated to advances in medical technologies that contribute to longer,healthier lives for women. We were the first company to bring imaging and interventiontogether, delivering continuum of care options for screening, diagnosis and treatment.In the field of breast biopsy, we continue to work with physicians to discover and delivermore compassionate and effective solutions for women.2002ATEC SystemFirst compassionate,minimally-invasivebreast biopsyoption utilizinga closed system 2003200420052006ATEC MRIFirst MRI guidedbreast biopsy systemATEC MRI AccessFirst MRI biopsy needlewith hemisphericaltip to increasepatient spectrumTriMarkBiopsy Site Markers TriMarkSecond ShapeBiopsy Site MarkersATEC SapphireFirst multimodalitybreast biopsy systemfor ultrasound, MRI,stereotacticFirst everpetite needleSpecially designedfor use on womenwith thin breasts20082009SecurMarkA complete familyof biopsy sitemarkers providingsuperior visualization ATEC with NaviscanPEM imagingFirst proceduresperformed inMarch 2008 2010ATEC with theDilon BSGI systemFirst proceduresperformed inDecember 2009 Hologic Acquires SurosSurgical SystemsSecurMarkDistinct ShapesStainless Steel BiopsySite Markers

I n t e r v e n t i o n a lB r e a s tS o l u t i o n sInvesting in a Healthier Futurefor Women Around the WorldHologic is a growing global company and a leadingprovider of healthcare systems for women around theworld. We’re proud of the difference we’ve made inwomen’s lives for 25 years and we recognize theresponsibility that our leadership position brings.At Hologic, we’re doing more than hoping for ahealthier future for women. We’re investing the timeand money to develop breakthrough technologiesand imaging systems that contribute to earlierdetection, more accurate diagnoses, and betteroverall patient care.Hologic goes beyond delivering advanced detection,intervention, and treatment technologies; we standbehind our systems with strong service and supportin healthcare.We deliver everything from highly trained clinicalproduct support team specialists and technicalproduct support to service dispatch to keep Hologicproducts up and running. Plus, we support medicalprofessionals with a full curriculum of online andonsite applications training to help them take advantageof the latest technologies, streamline workflow, boostproductivity, and improve patient care.

Hologic is defining the standard of care in women’s health.Our technologies help doctors see better, know sooner, reachfurther and touch more lives. At Hologic, we turn passion intoaction, and action into change.Breast IMAGING SOLUTIONS interventional Breast Solutions Bone Healthprenatal health gynecologic health molecular diagnosticswww.hologic.com info@hologic.com North America / Latin America35 Crosby DriveBedford, MA 01730-1401USA 1.781.999.7300EuropeEverest (Cross Point)Leuvensesteenweg 250A1800 VilvoordeBelgiumAsia Pacific7th Floor, Biotech Centre 2No. 11 Science Park West AvenueHong Kong Science ParkShatin, New TerritoriesHong KongAustraliaSuite 402, Level 42 Lyon Park RoadMacquarie Park NSW 2113AustraliaPB-00170 US/INTL (7/12). Hologic 2012. Printed in USA. All rights reserved. Specifications are subject to change without prior notice. Hologic, Affirm, Aixplorer, ATEC, Celero, Eviva, MammoPad,MultiCare Platinum, SecurMark, Selenia, Dimensions, StereoLoc II, SureSight, and TriMark are trademarks or registered trademarks of Hologic and/or Hologic subsidiaries in the United States and/orother countries. All other trademarks, registered trademarks, and product names are the property of their respective owners.

1 Schrading S, Simon B, Braun M, Wardelmann E, Schild H, Kuhl C. MRI-Guided Breast Biopsy: Influence of Choice of Vacuum Biopsy System on the Mode of Biopsy of MRI-

Related Documents:

EnCor Enspire and EnCor Ultra Breast Biopsy Systems are indicated to provide breast tissue samples for diagnostic sampling of breast abnormalities. CONTRAINDICATIONS: The EnCor Enspire and EnCor Ultra Breast Biopsy Systems are contraindicated for those patients where there is an increased risk of complication

1 ENCOR ENSPIRETM Breast Biopsy System Instructions for Use Caution: Federal (U.S.A.) law restricts this device to sale by or on the order of a physician. A. DEVICE DESCRIPTION The ENCOR ENSPIRETM Breast Biopsy System provides control operations for specialized biopsy instruments intended to

4 Breast cancer Breast cancer: A summary of key information Introduction to breast cancer Breast cancer arises from cells in the breast that have grown abnormally and multiplied to form a lump or tumour. The earliest stage of breast cancer is non-invasive disease (Stage 0), which is contained within the ducts or lobules of the breast and has not spread into the healthy breast tissue .

Excision – full thickness (through the dermis) removal of a lesion, including margins and simple repair These codes are notused for: A biopsy, a shaving of a lesion, or destruction of a benign, pre-malignant, or malignant lesion Excision of a pilonidal cyst Excision of a pressure ulcer 8

11750 Excision nail matrix permanent removal 11755 Biopsy nail unit separate procedure 11760 Repair nail bed 11770 Excision pilonidal cyst/sinus simple 11772 Excision pilonidal cyst/sinus complicated 12031 Repair intermediate s/a/t/e 2.5 cm/ 12032 Repair intermediate s/a/t/e

B. Order a biopsy to screen for breast cancer C. Prescribe chemotherapy D. Perform imaging studies to visualize tumors Imaging studies followed by biopsy analysis found a primary tumor of 3.5 cm in diameter and a 1.2 cm lesion in the axillary lymph node Diagnosed with grade 2 stage II breast cancer Breast cancer subtype: Triple .

Breast cancer development In the United States, breast cancer is the most common cancer diagnosed in women (excluding skin cancer). Men may also develop breast cancer, but less than 1% of all people with breast cancer are men. Breast cancer begins when healthy cells in the breast change and grow uncontrollably, forming a mass called a tumor.

Woodland Park School District Reading Curriculum English Language Arts Curriculum Writers: Elisabetta Macchiavello, Nancy Munro, Lisa Healey-Wilk, Samantha Krasnomowitz, Monica Voinov, Michele Skrbic, Krystal Capo, Nicole Webb, Veronica Seavy, Pamela Yesenosky, Steve Sans, Rosemary Ficcara, Laura Masefield, Meghan Glenn 2016-2017 Carmela Triglia Director of Curriculum and Instruction. 1 .