Air Conditioning Network Service System PCNGO1214C

2y ago
13 Views
2 Downloads
4.14 MB
8 Pages
Last View : 22d ago
Last Download : 2m ago
Upload by : Hayden Brunner
Transcription

PCNGO1214CAir Conditioning Network Service SystemPreventive MaintenanceThe intelligent Touch Manager can be connected to Daikin’ s own Air Conditioning Network Service Systemfor remote monitoring and verification of operation status for VRV system. By its ability to predictmalfunctions, this service provides customers with additional peace of mind.Enhanced convenience with link to the Air Conditioning Network Service SystemThe intelligent Touch Manager connects seamlessly to Daikin’s 24-hour Air Conditioning Network Service System.ACC centrePersonnel at the centre monitor theoccurrence of malfunctions and tracktheir cause via the Internet.Advance malfunction warnings helpprevent the sudden occurrence ofproblems later.TroubleEven malfunctions difficult to identifycan be monitored remotely.Allows dispatching ofservice engineers withouta call from customers.Air Conditioning Network Service System*RepairEnable prompt repairs as service engineersknow the cause of the problem beforehand.*Because of restrictionsin applicable areas andrelease times, please consulta Daikin representativeseparately for details.One touch selection to total air comfortDaikin Offers a Variety of Control SystemsConvenient controllers that offer more freedom to administratorsEase of use and expanded control functionsThe user-friendly controller features colours, multilingual function, and icons in the display for ease ofunderstanding. A wide variety of control methods can be accommodated, permitting administrators tomonitor and operate the system even when they are away from the controller.DCS601C51Connect VRV system to your BMS via BACnet or LONWORKS Compatible with BACnet andLONWORKS , the two leading opennetwork comunication protocols, Daikinoffers interfaces that provide a seamlessconnection between VRV system andyour BMS.Dedicated interfaces makeDaikin air conditioners freelycompatible with open networks BACnet LonWORKS Seamless connectionbetween VRV systemand BACnet opennetwork protocol.Facilitating the networkintegration ofVRV systemand LONWORKS DMS502B51(Interface for use in BACnet )DMS504B51(Interface for use in LONWORKS )Notes: 1.BACnet is a registered trademark of American Society of Heating , Refrigerating andAir-Conditioning Engineers(ASHRAE).2.LONWORKS is a trademark of Echelon Corporation registered in the United States and other countries.Using intelligent Touch Manager1. A Daikin-trained engineer must perform installation of the intelligent Touch Manager.2. The clock of the intelligent Touch Manager should be adjusted once a month.3. Daikin’s unique PPD system calculates the energy consumption of each indoor unit based on its operation data output. Note that PPD is not a “meter”adapted to the methods of measuring electrical power consumption in each country. Tenant billing systems differ by country according to each country’srespective legal system. Data obtained by PPD is for reference use only and should not be used for official financial transactions.06/16 ADSpecifications, designs and other content appearing in this brochure are current as of June 2016 but subject to change without notice.ALL IN ONESystem solution for management of building air conditioning

One touch selection enables flexible control of equipment in a building.Various types of equipment in a buildingcan be controlled by a single controller.Individual air-conditioning controlEnergy controlThe flexible control achieved by the VRV system precisely meetsdifferent air conditioning needs in each room (e.g. offices,conference rooms, hotel rooms).The status of energy consumption in a building (e.g. electricity,gas) can be checked and analyzed. The data can then beeffectively utilized to ensure energy-efficient operation.Environmental monitoringThe indoor environment (e.g. temperature, humidity, illuminance)can be monitored via various sensors. This feature is effective forcontrolling and maintaining comfort.Smart phone operationLighting controlDALI-compatibleDALI-compatibleAir conditioners can be operated by smart phones via Wi-Fi.This feature is effective as a value-added service for tenants etc.DALI-compatible LED lighting systems can be controlled andmonitored. Lighting control is enhanced through an interlockfunction with air conditioners and other functions.Smart phoneYou can control VRV system fromanywhere through Wi-FiAir-conditioning control for large spacesAir handling units can also be controlled. Large spaces, such asentrance halls and shopping malls, can be easily controlled toensure comfort.Energy-efficient control of airconditioning and lighting is the keyto cutting energy costs.Electricity consumption ratio in typical office buildingsOther12%Officedevice16%Building equipment controlHVAC48%Lighting24%Various types of equipment other than air conditioners, includingventilators, fans, and pumps, can also be controlled.HVAC and lightingaccount for 72%.Source: Agency for Natural Resources and Energy, Government of JapanPump1Fan2

By controlling the VRV system using the intelligent Touch Manager,energy saving can be promoted while maintaining comfortAir-conditioning power consumption can be reduced by20 to 30%, using energy-efficient controlCase Study at actual buildingComfort with minimum energyCASE 1: OfficeIn office buildings, approx.30-50% of total electricityconsumption is occupied by airconditioning.intelligent Touch Manager provides ahuge potential of cost saving.The air-conditioning power consumption was cut by32%.(kWh)*A/C( C )18,000FY12 power consumptionSpace heatingFY13 power consumption16,00030.0FY12 OA tempFY13 OA temp14,000Space cooling25.012,00020.010,000VentilationProject detail8,000Floor area: 1,400m2VRV ODU: 100HP6,00015.010.0* Verification target is only for 8th floor of the building.Schedule the operation time for each application.Define the setpoint range that users can change. All control was done by users with localremote controllers. No centralized controller was installedWith Remote controllerI’m dying in hot.Pi !Office:8:00-18:005.02,0000Very cold.16 CAdmin:8:30–17:00 Our centralized controller has been installed. The following three control logics havebeen newly added.AugSepOctNovNew controlWith Control unContentSetpoint restriction24-32 C(Cooling)16-20 C(Heating)Setpoint reset every morning26 C(Cooling)18 C(Heating)Turn OFF by schedule17:30 and 21:00Set point range 22 C - 28 CWh y ?Common area:9:00–17:00Meeting room:No scheduleJulWhat’s NewRecepion:9:00–17:00Machine room:24 hours4,000BackgroundIt can notbe setbelow thisOh! Cool.Case Study at actual buildingCASE 2: UniversityThe total power consumption in the building was cut by2013Before(kWh)*Bldg.22 Power consumptionOA temperature305,000Turn the unit OFF if a user didn’t.Reset setpoint regularly.254,00020Project detail3,000Floor area: 8,100m215*900m2 / floor VRV ODU: 796HPChange toStopWorking hours(Scheduled)Turn ON again by remote controller,forgot to turn OFF, and left.2,00020 CBackgroundStart24ºCSaved power consumptionby control system20ºC17:00Turn offas scheduled318:30Automatically tum OFFto cut wasteful operation101,000* Less than 20 C on uneJulyWhat’s NewSaved power consumptionby control system8:00 All control was done by users withlocal remote controllers. No centralized controller was installed. Setpoints were not controlled.8:008:0010:00Set at 24 C18:008:00 Our centralized controller has been installed. The following three control logics havebeen newly added.New controlContentSetpoint restriction22-32 C(Cooling)Setpoint reset everyday24 C(Cooling)Turn OFF by schedule19:00 and 21:00Reset to 24 C4

For Energ y Saving & Comfortintelligent Touch Manager maximises the advantages of VRV featuresintelligent Touch Manager is an advanced multi-zone controller that provides the most cost-effective way tocontrol and monitor the Daikin VRV system.In addition to switching lights on and off, advanced lighting control,such as illuminance adjustment, can be achievedLighting control (Option)The 10.4" LCD touch screen is easy to use with three different screen views to include the floor plan layoutConnection to DALI - compatible lighting control systemview, icon view and list view and menus for system configurations.It is also easy to use with standardized remote Web Access from your PC.It can manage a total of 650 management points consisting of up to 512 Daikin indoor unit groups ( up to1024 indoor units ) along with building equipment control / monitoring with Digital Inputs / Output ( Di/Dio ) ,Simple wiring (daisy chain) enables management of LED lighting by theintelligent Touch Manager.Various air conditioning and lighting control is enabled through the interlockwith occupancy sensors and illuminance sensors.DALI-compatibleDALI-compatiblePlease contact your local sales office for details.Analog Inputs / Output ( Ai/Ao ) and Pulse input ( Pi ) optional devices.Air conditioning and lighting for which power consumption is high can beefficiently controlled to promote energy conservation and cost reduction!Lighting control achieved bythe intelligent Touch ManagerOnly When and Where NecessaryFlexible control can be achieved to meet air conditioning needs in each roomSaving energy by preventing wasteful operation in unoccupied periodsTenant 1Working day: Mon - FriWorking hours: 9:00 - 17:30Setpoint: 24 C[ Operation ] Switch-on/switch-off operation Illuminance (1–100%) control Various illuminance patterns can beregistered Registered pattern can be selected fromintelligent Touch ManagerSystemDCM009A51(BACnet Client option)LANWAGO I / O system[ Monitoring ] Switch-on/switch-off status monitoring Lighting abnormality monitoring Illuminance monitoring DALI occupancy sensor monitoring DALI illuminance sensor monitoringBACnetcontroller750-831DALI module753-647DALI BUSDALI LED driverLED lightSensor(occupancy /illuminance)Tenant 1[ Overview of control ]Tenant 2 Up to 5 DALI modules can be connected to asingle BACnet controller.Tenant 3Tenant 4Tenant 2 Up to 64 DALI LED drivers (64 addresses) canbe connected to a single DALI module. 64 DALI addresses can be freely assigned to upto 16 groups using a single DALI module.(Each group corresponds to a managementpoint of the intelligent Touch Manager.) Up to 16 scenes can be set to a single DALImodule.Working day: Mon - FriWorking hours: 8:00 - 17:00Setpoint: 22 C Up to 12 sensors (occupancy, illuminance) canbe connected to a single DALI module. DALI BAS simplifies wiring and setting work bydaisy chain wiring and automatic addresssetting.Easy maintenance and energy saving by lighting controlCase1Tenant 3Working day: Mon - SatWorking hours: 8:00 - 19:00Setpoint: 25 CSwitch-on / switch-off andilluminance are controlled based on aschedule to cut wasteful powerconsumption. Failing to switchoff lights is prevented.Case2Case3Occupancy sensors are used toeliminate both wasteful lighting and airconditioning.When a room is unoccupied,the air conditioning stops and thelighting is switched off.OFFRequirements for air conditioning system depend on theapplication of buildings.In this example, each floor of the office building is occupiedby different tenants, and they have their own preferencesdue to their working days and hours.intelligent Touch Manager has the flexible scheduleprogramme which can set specific operation days, time,and setpoint for each tenant or even each indoor unit.Therefore the air conditioning system can operate onlywhen and where necessary irrespective of the motivationfor energy saving of the tenants.5Lighting abnormalities(e.g. burned-out bulbs) can bechecked onthe intelligent Touch Manager screen.Lighting maintenance becomes easier andquicker.OFFTenant 4Working day: Mon - SunWorking hours: 7:00 - 23:00Setpoint: 20 C Optimal illuminance reduces energy.The layout screen enables quickidentification of specific locations.6

Not Only VRV System, but Also Other Building EquipmentRemote monitoringIntegrated control for air conditioning in large spaces can be achieved by a single controllerMultiple buildings can be managed from one siteA wide variety of equipment can be connectedintelligent Touch Manager covers not only the VRV systembut also other air conditioning systems (e.g. air handling units)and building equipment (e.g. sensors).Remote monitoring controlThe Web function enables management for the Daikin VRV system with other building equipment integrated intointelligent Touch Manager that can be accessed from your PC*.All operations and system configurations which you can do on the intelligent Touch Manager touch screen can bedone through Web access.VRV systemE-mail alert enables prompt response by service engineers based timely and precise knowledgeof what happened in the system at the remote site.Property Manager /EngineeringBACnet / IPRS485Network / InternetOne D -NET systemMax. 64 indoor unit groups (128 indoor units)Di / PiFire alarm,Electricity monitoringFire alarmUnified Monitoring andControlOutdoor‐air processingkWh meterAll views and menus can be accessed via WebAir handling unitChiller*Flash player is required.WAGO I/O up to 30 nodesE-mail alerts for reporting malfunctionsBuilding equipmentLighting, pump, fan, keycard switch,window contact switch, sensors( temperature, humidity, CO2, lux, occupancy. )PumpFanKeycard switchSensorE-mail alerts are sent immediately to informconcerned parties of malfunctions involvingequipment connected to the intelligent TouchManager. Conveying equipment models and errorcodes, these e-mail alerts enable recipients totake prompt action and can be set for specificequipment.E-mail alerts aresent tosmartphones andPCs.Up to 10 e-mail addressescan be registered.EffectiveA wideservicevarietyfunctionsof equipmentofferedcanto tenantsbe conSmart phone will be a remote controller of VRV system (Option)Users can operate andcheck the status ofVRV system from their smartphones via Wi-Fi.It is not necessary to movewhere a remote controller islocated with this feature.VRV system in other roomscan be operated, and theirstatus can be checked. It isalso possible to check if airconditioners in other roomsremain switched on etc.,helping achieve energysaving.7For buildingsVRV Smart Phone Remote ControllerTo be released in August 2016VRV Indoor unitUp to 512 indoor units can be controlled.Just add SVMPC2 tothis systemSVMPC2For houseVRV Smart Phone Control SystemVRV Indoor unitUp to 64 indoor units can be controlled.Just add SVMPR2 tothis systemSVMPR2VRVOutdoor unitVRVOutdoor unitLAN cableLAN cableWi-Fi routerSmart phoneYou can controlVRV system fromanywhere through Wi-FiWi-Fi routerSmart phoneYou can controlVRV system fromanywhere in your housethrough Wi-FiMonitorControl8

Energy Management ( Energy Navigator Option )Tenant Management ( PPD * Option )Motivating for further energy savingReporting the power consumption of VRV system for each tenantEnergy saving assisted by Energy Navigator (Option)kWh meterPowerSupplykWh meterLightingiTM plus adaptor(Up to 7)Tenant BLOWTenant CMEDIUMkWh meterEnergy consumption data is presented on a daily and monthly basis. Also, energy targets andprojected energy consumption data as well as comparison data with the previous year’s actualresults are presented in a user-friendly format to help ensure energy-saving control.Daily energy consumptionOperation durationRoom temperatureExpansion valveopening rationalm froet merHourly energy consumption ismeasured and the intelligent TouchManager records data sent from theelectrical meter.Daikin’ s PPD keeps track of powerdistribution for each indoor unit. Itperforms air conditioning billingcalculations quickly and automatically.HIGHAutomatic calculation oftotal power consumption ofindividual indoor unitshkWh meterTenant AkWOperational information of individualindoor units are monitored, based ondistribution of power consumption ofoutdoor units.Operational informationof individual indoor unitsPulth se seigThe energy consumption isproportionally calculated for each indoorunit. The data can be used for energymanagement and calculation of airconditioning usage fees for respectivetenants.Energy consumption trends of all the equipment(including air conditioning units) can be easilyunderstood by using the Energy Navigatorfeature.Here users can identify air conditioning units thatare suspected of overcooling or kept running inunoccupied rooms.The Energy Navigator feature will also providesupport in formulation and verification ofenergy-saving measures to help ensureadvanced energy management.Accumulated data appearsin an easy-to-understand graph.With the PPD function, power consumption can be calculated for each indoor unit (Option)Tenant BTenant AIt is easy to output PPD data.PPD data is output in CSV format toa PC or USB memory device andcan be freely processed andmanaged.kWh meterTenant CTotal power consumption*PPD (Power Proportional Distribution) is Daikin’s proprietary calculation method.Comparison from the previous yearMonthly energy consumptionAir conditioning bills can be issued by one clickElectricity bills can be easily calculated for each tenant (Option)Warning indicationActual daily energyconsumptionCumulate lineCurrent month’s targetPrediction lineDaily average to achievemonth’s targetInformation concerning energymanagement of the system can beviewed on the user’s own PC via LAN.Warning indicationActual monthly energy consumptionMonthly target energy consumptionCumulate lineCurrent year’s targetPrediction lineMonthly target to achieveyear’s targetCurrent year’senergy useCurrent year’scumulate linePrevious year’scumulate linePrevious year’senergy useThe power consumption of VRV controlledby the intelligent Touch Manager can beeasily managed for each tenant using aPC. The electricity bill settings facilitatebilling work through easy calculation andissuance of VRV electricity bills.Internet / EthernetHUBSVMPS1User’s PCUser’s PCLANInvoiceThe degree of ruledeviation increasestoward the upper rightarea of the graph.Energy consumption is automaticallyevaluated for each room.Based on the accumulated data, theintelligent Touch Manager automaticallyidentifies rooms and air conditioning unitsthat substantially deviate from operationrules established by the user for operationtime and predetermined temperaturesettings. A benchmark showing ways tofurther reduce energy consumption canbe displayed to alert users to even greaterenergy and cost savings.InvoiceInvoice[ Main functions ] Register tenants Set the electricity unit price for 5 time zonesPlot areaNumber of hours of rule deviationNumber of days of rule deviationRoom nameNumber of hours and days of rule deviationExtra energy consumption Calculate power consumptionand electricity charge for each tenant Show aggregation results in the specifiedperiod for each tenant Output the results (Printout and CSV file)9Tenant registration screenSetup screenVRV electricitybill screen10

S p e ci fica ti o nsS y st em st r u c t u r eintelligent Touch Manager functionFunctionCategoryBasic functionsMaximum number of adaptors: 7Management pointsMaximum number of management points: 650(Number of D connection management points: 512)AreasMaximum number of areas: 650Maximum area hierarchies: 10Up to 512 groups(1024 indoor units)Up to 650management pointsAir ConditioningNetwork Service SystemEnglish, French, German, Italian, Spanish, Portuguese, Dutch, Chinese, and JapaneseSupported languagesIcon viewIcons show the operation status of equipment.List viewDetailed information of each management point is displayed.Layout viewUp to 60 screens can be created. (Engineering option)HistoryOne D -NET systemMax. 64 indoor unit groups (128 indoor units)Up to 500,000 events are recorded in history including malfunctions, operations,automatic control, and system information.Operation origin is also recorded.ScheduleWeekly schedule7 days of the week 5 special days can be set.Yearly calendarSpecial days can be specified by date or month/week/day of the week.Special day settings can be reused every year.Seasonal scheduleMax. 64 indoor unit groupsUSB 2.0Flash driveDi/Pi portWeb Accessvia InternetMax. 64 indoor unit groupsNumber of programmes: 500Interlock is possible for on/off, malfunction, analogue value,and operation mode switching.Number of programmes: 31Automatic changeoverNumber of changeover groups: 512Temperature limitNumber of temperature limit groups: 8Upper limit range: 32-50 CLower limit range: 2-16 CSliding temperatureNumber of sliding temperature groups: 8Outdoor temperature range: 18-34 CSetpoint range: 16-32 CKRP928BB2SWeb Accessvia LANUp to 7 AdaptorsFire alarmOperation stop is selectable from 30, 60, 90, 120, 150, and 180 minutes.SetbackSetback setpoint can be set for 2 patterns.Temperature range: 1-7 C , 1- 7 C (setpoint shift amount)Power Proportional DistributionHourly Power Proportional Distribution results up to 13 months are recorded.The system supports data output in CSV format.Energy NavigatorActual results of daily/monthly energy consumption are shown in graphs.Comparisons can be made with predetermined values/actual results of the previousyear.Inefficient operation of VRV indoor units is automatically identified, and energywaste is calculated.Web accessWeb browsers can display the same type of screen as the intelligent Touch Manager.Up to 4 administrators and 60 general users can be registered.Screens and operation accessible to general users can be restricted.SystemAir ConditioningNetwork Service11Residential A/CWAGO I / O up to 30 nodesBACnet / IPAir Handling UnitUp to 10 e-mail addresses can be set.Addresses for sending malfunction alerts can be set by range of management points.The SMTP server authentication method is selectable from no authentication,POP before SMTP, and SMTP-AUTH.Indoor units connected to D -NET are automatically detected,and icons for respective models are automatically registered.SecurityScreen lock functions are available.Access restrictions can be set for each general user.Screen saversScreen savers are selectable from 3 patterns.Setting of contact informationContact information for servicing can be registered.Air Conditioning Network Service SystemA service agreement needs to be concluded.Energy Saving Air Conditioning NetworkService SystemA service agreement needs to be concluded.3rd partyBACnet controllerPumpFanSensor Keycard switchWAGO I / O systemBACnet controller750-831DALI module753-647DALI BUSOperation froma smart phoneDALI LED driverRemote accessAutomatic registrationkWh meterUnneeded heating is prevented.Timer extensionE-mail alertsMax. 64 indoor unit groupsDi / Pi LineProgrammes for respective seasons can be switched by date.Emergency stopHeating Mode Optimisation (HMO)iTM Plus Adaptor100MbpsEthernetNumber of programmes: 100Up to 20 actions/day can be set.InterlockData controlRemarksiTM plus adaptor (DCM601A52)Monitoring screensAutomatic controlintelligent Touch Manager System OverviewSensor(occupancy / illuminance)LED lightSmart phoneWi-Fi routerSVMPC2:for controlling 512 unitsSVMPR2:for controlling 64 unitsDALI BUSDALI LED driverorSensor(occupancy / illuminance)LED lightTenant controlDALI BUSDALI LED driverWeb Accessvia LANSVMPS1LED lightSensor(occupancy / illuminance)12

M ai n s p ec i f i c a t i on sS p e ci fica ti o n sintelligent Touch ManagerTypes of management points and target equipment / interfaceSupported equipmentManagement pointNumber of management pointsD -compatible indoor unitsPortMaximum: 512 *1Interface adaptor for SkyAir (DTA102A52 , DTA112BA51)UseD1chD -NET (Up to 64 groups)LAN1chWeb Access (100BASE-TX )RS4851chExternal I/O module (Di,Dio,Ai,Ao,Pi)Di(Pi)4chEmergency stop input (Di1)Pulse input,contact signal inputplus ADP IF1chiTM plus adaptor (Up to 7 adaptors)internalmodem (option)1chAir Conditioning NetworkService SystemAHU kit (EKEQFCB,EKEQDCB,EKEQMCB)IndoorNumberInterface adaptor for residential indoor unit (KRP928BB2S)Central control adaptor kit for package A/C (DTA107A55)OutdoorVRV outdoor unitsMaximum: 80VentilatorHeat Reclaim VentilatorMaximum: 512 *1D3 ChillerD -compatible air-cooled chillers (UWA/Y) / water-cooled chillers (ZUW)Maximum: 320 *2Di port of intelligent Touch ManagerDiMaximum: 32 *3Di port of iTM plus adaptorD3 DiD Di Unit (DEC101A51)Maximum: 512 *1External DiWAGO DiMaximum: 512 *4D Dio Unit (DEC102A51)Maximum: 512 *1D3 DioGeneral-purpose adaptor (DTA103A51)External DioMaximum: 512 *4WAGO Di, DoPi port of intelligent Touch ManagerPiMaximum: 32 *3Pi port of iTM plus adaptorInternal PiEnergy consumption of VRV outdoor unitsExternal PiWAGO Pi (Not available for PPD function)External AoWAGO AoExternal AiWAGO AiInternal AiOutdoor temp of Outdoor unitRoom temperature, setpoint of indoor unitsD3 Chiller outleta/inlet water temperaturesBACnet DiBACnet object BI/BO/BV can be linkedBACnet DioBACnet object BI/BO/BV can be linkedBACnet AiBACnet object AI/AO/AV can be linkedBACnet AoBACnet obejct AO/AV can be linkedAHU *6BACnet connectable AHU using MicroTechPOWER SUPPLY : DCM601A51 AC100-240V( 10%)(50/60Hz)INPUT : 23WMASS : 2.4kgFUSE AMP : 3.15AOperating temperature limit : -0 - 40Operating humidity limit : MAX.15 - 85Storage temperature range : -15 - 60Installation direction : Vertical direction onlyMaximum: 80Maximum: 512 *4Maximum: 512 *4Maximum: 512 *5Maximum: 20*1: Total of D connection equipment (Indoor, Ventilator, D3 Chiller, D3 Di, D3 Dio) *2: Maximum number of management points for D3 Chiller only*3: Total of Di/Pi management points *4: Total of External Di, External Dio, External Ai, External Ao, External Pi and Internal Ai *5: Total of BACnet points (include AHU*6)*6: AHU count as 20 BACnet pointsDAIKIN supplied equipment & Software optionItemModelDCM601A51intelligent Touch ManagerDCM601A52iTM plus adaptor (Option)DCM002A51iTM power proportional distribution software (Option)DCM007A51HTTP interface software (Option)DCM008A51iTM energy navigator software (Option)DCM009A51BACnet client software (Option)WAGO I/O systemDi module (DC24V/4.5mA) : 750-400,750-432Di module (DC24V/2.8mA) : 750-430Do module (AC230V/DC30V 2A) : 750-513/000-001Do module (DC24V 0.5A) : 750-504Ai module (4 20mA 12bit) : 750-454,750-455Ai module (-10 10V 13bit) : 750-479Ai module (0 10V 12bit) : 750-459Ao module (4 20mA 12bit) : 750-554,750-555Ao module (0 10V 10bit) : 750-560Ao module (0 10V 12bit) : 750-559Thermistor module (NTC20K) : 750-461/020-000Thermistor module (Pt 100/RTD) : 750-461/750-460Locally supplied equipmentItem13SpecificationiTM plus adaptor (DCM601A52) Input / Output portPortThermistor module (Pt 1000/RTD) : 750-461/000-003,750-460/000-003Thermistor module (Ni 100/RTD) : 750-461/000-004Thermistor module (Ni 1000 TK6180/RTD) : 750-461/000-005,750-460/000-005Pi module : 750-638DC24V Power supply unit : 787-712Modbus Communication unit : 750-315/000-002/K190-6442 (DAIKIN custom)Terminator module : 750-600Power module : 750-613Connector : 750-960BACnet DALI moduleWAGO BACnet controller module : 750-831WAGO DALI master module : 753-647WAGO DALI DC power supply module : 753-620NumberUseplus ADP IF1chiTM plus adaptor (Up to 7 adaptors)D1chD -NET (Up to 64 groups)Di(Pi)4chPulse input,contact signal inputPOWER SUPPLY : DCM601A52 AC100V-240V( 10%)(50/60Hz)INPUT : 6WMASS : 0.5kgFUSE AMP : 3.15AOperating temperature limit : -10 - 50Operating humidity limit : MAX.15 - 85Storage temperature range : -15 - 60Installation direction : Vertical direction onlySVM Series ModelModelCommentUSB memoryUSB 2.0Up to 32GB memory can useSVMPR2VRV Smart Phone Control System for residenceWeb browser : Internet Explorer 11 Firefox 26.0Chrome 32.0Flash Player Ver11.9.900.170SVMPC2VRV Smart Phone Remote Controller for buildingPC for Web accessSVMPS1Tenant Billing System with PPD14

1. A Daikin-trained engineer must perform installation of the intelligent Touch Manager. 2. The clock of the intelligent Touch Manager should be adjusted once a month. 3. Daikin’s unique PPD system calculates the energy

Related Documents:

Evacuate and Charge the Air Conditioning System (A7-E-4) 30 Chapter 15 - A/C System Diagnosis and Service Air Conditioning System Performance Test (A7-A-1, A7-A-3) 31 Air Conditioning Noise Diagnosis (A7-A-4) 32 Refrigerant Identification/Read Pressures (A7-A-5) 33 Leak Test the Air Conditioning System (A7-A-6) 34

The winter air conditioning uses a heat pump (refrigeration system operated in the reverse direction) and a humidifier. Depending upon the comfort of the human beings and the control of environment for the industrial products and processes, air conditioning can also be classified as comfort air conditioning and industrial air conditioning. .

Differences Between Classical and Operant Conditioning (see table 5.5, page 228) Classical Conditioning Operant Conditioning In classical conditioning, the organism learns an association between two stimuli—the CS and UCS (eg. food and tone)—that occurs before the behavior (eg. salivation). In operant conditioning, the organism learns an

design an air conditioning system for a shopping mall with proper distribution of air and also separate energy consumption system for different vendors. Keywords:HVAC, Air-Conditioning,Refrigeration, HACR. I. INTRODUCTION HVAC (heating, ventilating, and air conditioning; also heating, ventilation, and air conditioning) is the technology

Classical Conditioning & Operant Conditioning. What is Classical Conditioning? HowDoWeLearn? ClassicalConditioning § § § Pavlov’sExperiments ExtendingPavlov’sUnderstanding Pavlov’sLegacy 2 Learning Objective: Students will be able to describe the difference between Classical and Operant Conditioning.

February 2 EQ- How does operant Agenda: conditioning work? SSPBC1 1.Daily Sheet 2.Review Classical Conditioning (Ex. From real life) 3.Operant Conditioning (notes, video, lab) 4. Practice Table of Contents: 93. Classical Conditioning Elements 94. Operant Conditioning Notes 95. OC Worksheet HW- Programmed Unit Assignment Consciousness HW Folders .

2. USE OF PROPER COMPRESSOR OIL Compressor oil used in conventional CFC12 air conditioning systems cannot be used in HFC134a air conditioning sys-tems. Always use genuine Toyota R134a air conditioning oil ND– OIL 8, made expressly for use with HFC134a. NOTICE: Compressor oil

Air conditioning and cooling as a unit Although air conditioning and engine cooling are two separate systems, they do affect each other. When the air conditioning is in use, there is a heavier load on the engine cooling system and the coolant temperature rises. The additives in the coolant not only protect against frost, but